Browse > Article
http://dx.doi.org/10.1007/s13296-018-0051-9

Evaluation of Three Support Shapes on Behavior of New Bolted Connection BBCC in Modularized Prefabricated Steel Structures  

Naserabad, Alifazl Azizi (Department of Civil Engineering, University of Sistan and Baluchestan)
Ghasemi, Mohammad Reza (Department of Civil Engineering, University of Sistan and Baluchestan)
Shabakhty, Naser (Department of Civil Engineering, Iran University of Science and Technology)
Arab, Hammed Ghohani (Department of Civil Engineering, University of Sistan and Baluchestan)
Publication Information
International journal of steel structures / v.18, no.5, 2018 , pp. 1639-1653 More about this Journal
Abstract
Bolted connections are suitable due to high quality prefabrication in the factory and erection in the workplace. Prefabrication and modularization cause high speed of erection and fabrication, high quality and quick return of investment. Their technical hitches transportation can be removed by prefabrication of joints and small fabrication of components. Box-columns are suitable members for bolted structures such as welded steel structures with moment frames in two directions etc., but their continual fabrication in multi-story buildings and performing the internal continuity plate in them will cause some practical dilemmas. The details of the proposal technique introduced here, is to remove such problems from the box columns. Besides, some other advantages include new prefabricated bolted beam-to-column connections referred to BBCC. This connection is a set of plates joined to columns, beams, support, and bolts. For a better understanding of its fabrication and erection techniques, two connection and one structural maquettes are made. The present work aims to study the cyclic behavior of connection numerically. To verify the accuracy of model, a similar tested connection was modelled. Its verification was then made through comparison with test results. The behavior of connection was evaluated for an exterior connection using three different support shapes. The effects of support shapes on rigidity, ductility, rotation capacity, maximum strength, four rad rotation strength were compared to those of the AISC seismic provision requirements. It was found that single beams support has all the AISC seismic provision requirements for special moment frames with and without a continuity plate, and box with continuity plate is the best support in the BBCC connection.
Keywords
Bolted connection; Modular prefabricated; Finite element analysis; Cyclic load; Box column;
Citations & Related Records
연도 인용수 순위
  • Reference
1 ABAQUS. (2017). User's manual version 2017. Pawtucket, RI: Hibbitt, Karlsson & Sorensen Inc.
2 Abidelah, A., Bouchair, A., & Kerdal, D. E. (2012). Experimental and analytical behavior of bolted end-plate connections with or without stiffeners. Journal of Constructional Steel Research, 76, 13-27.   DOI
3 AISC, ANSI 341. (2010). Seismic provisions for structural steel buildings. Chicago, IL: American Institute of Steel Construction Inc.
4 AISC, ANSI360. (2010). Specification for structural steel buildings. Chicago, IL: American Institute of Steel Construction Inc.
5 Azizi Naserabad, A., Ghasemi, M. R., Shabakhty, N., & Ghohani Arab, H. (2015). Patent "prefabricated BBCC connection for using in bolted steel structures". Patent Office, Tehran, Iran, Patent Record Number 86310.
6 Chen, C. C., Lin, C. C., & Tsai, C. L. (2004). Evaluation of reinforced connections between steel beams and box columns. Engineering Structures, 26, 1889-1904.   DOI
7 Dubina, D., & Stratan, A. (2002). Behavior of welded connections of moment resisting frames beam-to-column joints. Engineering Structures, 24, 1431-1440.   DOI
8 Fang, C., Yam, M. C. H., Lam, A. C. C., & Xie, L. (2014). Cyclic performance of extended end-plate connections equipped with shape memory alloy bolts. Journal of Constructional Steel Research, 94, 122-136.   DOI
9 Gerami, M., Saberi, H., Saberi, V., & Saedi Daryan, A. (2011). Cyclic behavior of bolted connections with different arrangement of bolts. Journal of Constructional Steel Research, 67, 690-705.   DOI
10 Gholami, M., Deylami, A., & Tehranizadeh, M. (2013). Seismic performance of flange plate connections between steel beams and box columns. Journal of Constructional Steel Research, 84, 36-48.   DOI
11 Liu, X. C., Xu, A. X., Zhang, A. L., Ni, Z., Wang, H. X., & Wu, L. (2015b). Static and seismic experiment for welded joints in modularized prefabricated steel structure. Journal of Constructional Steel Research, 112, 183-195.   DOI
12 Grimsmo, E. L., Clausen, A. H., Langseth, M., & Aalberg, A. (2015). An experimental study of static and dynamic behaviour of bolted end-plate joints of steel. International Journal of Impact Engineering, 85, 132-145.   DOI
13 Liu, X. C., Pu, S. H., Zhang, A. L., Xu, A. X., Ni, Z., Sun, Y., et al. (2015a). Static and seismic experiment for bolted-welded joint in modularized prefabricated steel structure. Journal of Constructional Steel Research, 115, 417-433.   DOI
14 Liu, X. C., Pu, S. H., Zhang, A. L., & Zhan, X. X. (2017). Performance analysis and design of bolted connections in modularized prefabricated steel structures. Journal of Constructional Steel Research, 115, 360-373.
15 Maggi, Y. I., Goncalves, R. M., Leon, R. T., & Ribeiro, L. F. L. (2005). Parametric analysis of steel bolted end plate connections using finite element modeling. Journal of Constructional Steel Research, 61, 689-708.   DOI
16 Mirghaderi, S. R., Torabian, S., & Keshavarzi, F. (2010). I-beam to box-column connection by a vertical plate passing through the column. Engineering Structures, 32, 2034-2048.   DOI
17 Mirghaderil, S. R., & Dehghani Renani, M. (2008). The rigid seismic connection of continuous beams to column. Journal of Constructional Steel Research, 64, 1516-1529.   DOI
18 Prinz, G. S., Nussbaumer, A., Borges, L., & Khadka, S. (2014). Experimental testing and simulation of bolted beam-column connections having thick extended endplates and multiple bolts per row. Engineering Structures, 59, 434-447.   DOI
19 Simoes-da-Silva, L., Lima, L., Vellasco, P., Dendrade, S., & DeCastro, R. A. (2008). Nonlinear dynamic analysis of steel portal frames with semi-rigid connections. Engineering Structures, 30, 2566-2579.   DOI
20 Rezaeian, A., Jamal-Omidi, M., & Shahidi, F. (2014). Seismic behavior of ConXL rigid connection in box-columns not filled with concrete. Journal of Constructional Steel Research, 97, 79-104.   DOI
21 Tagawa, H., & Liu, Y. (2014). Stiffening of bolted end-plate connections with steel member assemblies. Journal of Constructional Steel Research, 103, 190-199.   DOI
22 Torabian, S., Mirghaderi, S. R., & Keshavarzi, F. (2012). Momentconnection between I-beam and built-up square column by a diagonal through plate. Journal of Constructional Steel Research, 70, 385-401.   DOI
23 Wang, J., & Guo, S. (2012). Structural performance of blind bolted end plate joints to concrete-filled thin-walled steel tubular columns. Thin-Walled Structures, 60, 54-68.   DOI