• 제목/요약/키워드: bolt-load curve

검색결과 17건 처리시간 0.021초

Static and fatigue behavior of through-bolt shear connectors with prefabricated HFRC slabs

  • He, Yuliang;Zhuang, Jie;Hu, Lipu;Li, Fuyou;Yang, Ying;Xiang, Yi-qiang
    • Structural Engineering and Mechanics
    • /
    • 제83권1호
    • /
    • pp.109-121
    • /
    • 2022
  • Twelve push-out test specimens were conducted with various parameters to study the static and fatigue performance of a new through-bolt shear connector transferring the shear forces of interface between prefabricated hybrid fiber reinforced concrete (HFRC) slabs and steel girders. It was found that the fibers could improve the fatigue life, capacity and initial stiffness of through-bolt shear connector. While the bolt-hole clearance reduced, the initial stiffness, capacity and slippage of through-bolt shear connector increased. After the steel-concrete interface properties were improved, the initial stiffness increased, and the capacity and slippage reduced. Base on the test results, the equation of the load-slip curve and capacity of through-bolt shear connector with prefabricated HFRC slab were obtained by the regression of test results, and the allowable range of shear force under fatigue load was recommended, which could provide the reference in the design of through-bolt shear connector with prefabricated HFRC slabs.

풍력터빈 지지구조물 L형 플랜지 볼트 접합부의 거동 특성에 관한 연구 (Study on Behavior Characteristics of L-Type Flange Bolt Connection for Supporting Structures of Wind Turbines)

  • 정대진;홍관영;최익창
    • 한국전산구조공학회논문집
    • /
    • 제34권5호
    • /
    • pp.279-286
    • /
    • 2021
  • 본 논문에서는 풍력터빈과 하부구조물을 연결하는 L형 플랜지 볼트 접합부의 거동 특성에 대한 연구를 수행하였다. L형 플랜지 볼트 접합부는 링(Ring) 형태의 L형 단면 플랜지가 볼트에 의해 상하 체결되는 방식으로서 국내 풍력터빈에서 주로 적용되고 있는 연결방식이다. 특히 풍력타워 구조물은 이들 연결부의 손상이 전체 구조시스템의 붕괴로 이어질 수 있으므로 중요한 구조 요소 중 하나이다. 따라서 L형 플랜지 볼트 접합부에 대한 정확한 거동 특성의 이해가 필요하다. 본 연구에서는 FE 해석을 통하여 L형 플랜지에 작용하는 외력과 볼트장력의 관계, 그리고 L형 플랜지의 응력분포 변화를 외력 작용 단계별로 분석하였다. 여기서 FE 해석모델은 실제 링 형태의 L형 플랜지를 단일볼트의 L형 플랜지로 이상화하였다. 또한 볼트장력과 작용외력의 관계를 이론적으로 제안한 Petersen, Schmidt와 Neuper 그리고 VDI 2230의 볼트-외력 곡선모델에서 언급되는 접합부의 거동 불연속점과 FE 해석결과를 비교함으로써 FE 해석조건의 적절성을 검증하고, 각 볼트-외력 곡선모델의 특징과 L형 플랜지 볼트 접합부 거동 특성을 분석하였다. 그리고 L형 플랜지 단면 제원을 일부 변화시켜 볼트-외력 곡선의 변화를 분석하였다.

Experimental and numerical study of large high strength bolt shear connector embedded in HFRC

  • Yuliang He;Zhengxin Wang;Weiming Wu;Ying Yang;Yiqiang Xiang
    • Steel and Composite Structures
    • /
    • 제49권2호
    • /
    • pp.197-213
    • /
    • 2023
  • To investigate the static properties of large high strength bolt shear connector in hybrid fiber-reinforced concrete (HFRC) and normal concrete (NC), eight push-out test specimens with single/double nut and HFRC/NC slabs were designed and push-out tests were conducted. A fine 3D nonlinear finite element (FE) model including HFRC constitutive model was established by using ANSYS 18.0, and the test results were used to verify FE models of the push-out test specimens. Then a total of 13 FE models were analyzed with various parameters including fiber volume fractions of HFRC, bolt diameter and thickness of steel flange. Finally, the empirical equations considering the contribution of polypropylene fiber (PF) and steel fiber (SF) obtained from the regression of the test results and FE analysis were recommended to evaluate the load-slip curve and ultimate capacity of the large high strength bolt shear connector embedded in HFRC/NC.

A numerical investigation of the tensile behavior of the thread-fixed one-side bolted T-stubs at high temperature

  • You, Yang;Liu, Le;Jin, Xiao;Wang, Peijun;Liu, Fangzhou
    • Steel and Composite Structures
    • /
    • 제45권4호
    • /
    • pp.605-619
    • /
    • 2022
  • The tensile behavior of the Thread-fixed One-side Bolt (TOB) at high temperatures was studied using the Finite Element Modeling (FEM) to explore the structural responses that could not be measured in tests. The accuracy of the FEM was verified using the test results from the failure mode, load-displacement curve as well as yielding load. Three typical failure modes of TOB connected T-stubs were observed, which were the Flange Yielding (FY), the Bolt Failure (BF) and the Coupling Failure mode (CF). The influence of the flange thickness tb and the temperature θ on the tensile behavior of the T-stub were discussed. The initial stiffness and the yielding load decreased with the increase of the temperature. The T-stubs almost lost their resistance when the temperature exceeded 700℃. The failure modes of T-stubs were mainly decided by the flange thickness, which relates to the anchorage of the hole threads and the bending resistance of flange. The failure mode could also be changed by the high temperature. Design equations in EN 1993-1-8 were modified and verified by the FEM results. The results showed that these equations could predict the failure mode and the yielding load at different temperatures with satisfactory accuracy.

Numerical analysis on tensile properties of composite hybrid bonded/bolted joints with flanging

  • Cheng, Xiaoquan;Zhang, Jie;Zhang, Jikui;Liu, Peng;Cheng, Yujia;Xu, Yahong
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.265-272
    • /
    • 2018
  • A detailed study was carried out on the tensile properties of the single-lap joint of a steel panel bolted/bonded to a composite laminate with a flanging. Finite element model (FEM) was established to predict the strength and to analyze the damage propagation of the hybrid joints by ABAQUS/Standard, which especially adopted cohesive elements to simulate the interface between the laminate and adhesive. The strength and failure mode predicted by FEM were in good agreement with the experimental results. In addition, three influence factors including adhesive thickness, bolt preload and bolt-hole clearance were studied. The results show that the three parameters have effect on the first drop load of the load-displacement curve, but the effect of bolt-hole clearance is the largest. The bolt-hole clearance should be avoided for hybrid joints.

Experimental investigation on bolted rock mass under static-dynamic coupled loading

  • Qiu, Pengqi;Wang, Jun;Ning, Jianguo;Shi, Xinshuai;Hu, Shanchao
    • Geomechanics and Engineering
    • /
    • 제29권2호
    • /
    • pp.99-111
    • /
    • 2022
  • Instability of bolted rock mass has been a major hazard in the underground coal mining industry for decades. Developing effective support guidelines requires understanding of complex bolted rock mass failure mechanisms. In this study, the dynamic failure behavior, mechanical behavior, and energy evolution of a laboratory-scale bolted specimens is studied by conducting laboratory static-dynamic coupled loading tests. The results showed that: (1) Under static-dynamic coupled loading, the stress-strain curve of the bolted rock mass has a significant impact velocity (strain rate) correlation, and the stress-strain curve shows rebound characteristics after the peak; (2) There is a critical strain rate in a rock mass under static-dynamic coupled loading, and it decreases exponentially with increasing pre-static load level. Bolting can significantly improve the critical strain rate of a rock mass; (3) Compared with a no-bolt rock mass, the dissipation energy ratio of the bolted rock mass decreases exponentially with increasing pre-static load level, the ultimate dynamic impact energy and dissipation energy of the bolted rock mass increase significantly, and the increasing index of the ratio of dissipation energy increases linearly with the pre-static load; (4) Based on laboratory testing and on-site microseismic and stress monitoring, a design method is proposed for a roadway bolt support against dynamic load disturbance, which provides guidance for the design of deep underground roadway anchorage supports. The research results provide new ideas for explaining the failure behavior of anchorage supports and adopting reasonable design and construction practices.

고온다습 조건($82.2^{\circ}C$)에서 2열 볼트 체결 복합재 조인트의 강도에 관한 실험적 연구 (An Experimental Study on the Strength of Two Serial Bolt-Fastened Composite Joints under Elevated Temperature and Humid Condition)

  • 김효진
    • Composites Research
    • /
    • 제22권5호
    • /
    • pp.30-36
    • /
    • 2009
  • 복합재 부품의 전형적인 조인트 형태를 평가하기 위해서, 2열 볼트 체결 탄소섬유강화 복합재의 파손강도와 파손 모드에 대하여 연구를 수행하였다. 연구는 상온과 고온다습 조건에서 적층과 형상을 변수로 실험적으로 수행되었다. 실험결과를 바탕으로 다음과 같은 결론을 얻었다. 하중-변위 선도는 두 가지 형태로 관찰되었으며, 각 파손 모드는 하중-변위 선도로 특징지어진다. 고온다습 조건의 파손형태는 베어링 파손 모드이며, 베어링 파손 모드에서 파손 강도는 유효강성의 영향이 크지 않다고 분석된다. 고온다습 조건의 파손강도 감소는 침투한 수분에 의해 섬유와 모재의 층간 결합부의 물성 저하에 기인한다.

경충돌안전장치 설계를 위한 기초연구 (The basic study on the design of the Light Collision Safety Device)

  • 최원목;정현승;유원희;구정서;권태수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.238-244
    • /
    • 2006
  • The Light Collision Safety Device is used to protect the important part of trains and passengers at the low velocity accidents. The Light Collision Safety Device comprises mainly tension bolts, shear bolts and an energy absorber. The work mechanism of this device is that first, the tension bolts break at designed collapse load and second, the energy absorber absorb rest collision energy. In this paper, the tension bolt characteristics were validated by the simple tension test using the FEM(Finite Element Method) and the characteristic of the two types of energy absorber were compared by using the load-displacement curves and absorbed energy. Last, in order to determine integrated load-displacement curve of tension bolts and the energy absorber, the unified analysis was conducted by using the FEM.

  • PDF

전단력을 받는 더블 앵글 접합부의 비선형 거동에 관한 해석적 연구 (An Analytical Study on the Nonlinear Behavior of Double Angle Connections Subjected to Shear)

  • 이수권;홍갑표
    • 한국강구조학회 논문집
    • /
    • 제12권1호통권44호
    • /
    • pp.65-73
    • /
    • 2000
  • 상용 유한요소해석 프로그램인 ABAQUS(ver5.8)를 이용하여 전단력을 받는 더블앵글 접합부의 3D 해석을 수행하여 접합부의 모멘트-회전 관계곡선을 구하고 앵글과 볼트의 응력분포를 관찰한다. 해석시 주요 매개변수로는 볼트수, 게이지거리, 앵글의 두께로 하였으며 유한요소해석 결과로 구한 모멘트-회전곡선을 Richard가 제시한 예측식에 적용한 후 회귀분석을 통하여 접합부 거동을 예측하는 데 필요한 매개변수인 초기강성, 소성강성, 참조모멘트, 곡선형태변수를 구한다. 또한 매개변수들이 게이지거리, 앵글의 두께 및 볼트 수 변화에 따른 그래프를 작성하고 또한 이 그래프를 이용하여 접합부의 모멘트 및 LRFD의 접합부 분류에 따른 소성모멘트에 대한 접합부 모멘트의 비를 계산한다.

  • PDF

지지대 및 제결볼트를 이용한 프리캐스트 콘크리트 골조구조의 보 하단 철근 정착공법 개발 (Mechanical Bar Anchorage of the PC Beam in Beam-Column Joint Using Plates and Bolts)

  • 유영찬;최근도;김긍환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.539-544
    • /
    • 2000
  • The purpose of this study is to develop the mechanical anchorage, namely MAB-BOP (Mechanical Anchorage of 90$^{\circ}$ Hooked Bars with BOlt nad Plate) of the beam-column joint in precast concrete framed structures. Six specimens simulating typical interior beam-column joints were tested to investigate the mechanical characteristics of MAB-BOP. Of primary interest was the measurement of the slip of the anchored bar. Th load-slip curve obtained from this test were used to compare the mechanical performances of the different anchoring methods. Based on the test results, it was found that MAB-BOP showed sufficient anchoring strength capacity compared to 90$^{\circ}$ hooked bar method. So, MAB-BOP can be used as the anchoring methods of the reinforcing bars in PC beam-column joint.

  • PDF