DOI QR코드

DOI QR Code

A numerical investigation of the tensile behavior of the thread-fixed one-side bolted T-stubs at high temperature

  • You, Yang (School of Transportation and Civil Engineering, Shandong Jiaotong University) ;
  • Liu, Le (School of Civil Engineering, Shandong University) ;
  • Jin, Xiao (School of Civil Engineering, Shandong University) ;
  • Wang, Peijun (School of Civil Engineering, Shandong University) ;
  • Liu, Fangzhou (School of Civil Engineering, Shandong University)
  • Received : 2020.12.08
  • Accepted : 2022.11.15
  • Published : 2022.11.25

Abstract

The tensile behavior of the Thread-fixed One-side Bolt (TOB) at high temperatures was studied using the Finite Element Modeling (FEM) to explore the structural responses that could not be measured in tests. The accuracy of the FEM was verified using the test results from the failure mode, load-displacement curve as well as yielding load. Three typical failure modes of TOB connected T-stubs were observed, which were the Flange Yielding (FY), the Bolt Failure (BF) and the Coupling Failure mode (CF). The influence of the flange thickness tb and the temperature θ on the tensile behavior of the T-stub were discussed. The initial stiffness and the yielding load decreased with the increase of the temperature. The T-stubs almost lost their resistance when the temperature exceeded 700℃. The failure modes of T-stubs were mainly decided by the flange thickness, which relates to the anchorage of the hole threads and the bending resistance of flange. The failure mode could also be changed by the high temperature. Design equations in EN 1993-1-8 were modified and verified by the FEM results. The results showed that these equations could predict the failure mode and the yielding load at different temperatures with satisfactory accuracy.

Keywords

Acknowledgement

The authors wish to acknowledge supports from the National Natural Science Foundation of China (51578322).

References

  1. Agheshlui, H., Goldsworthy, H., Gad, E. and Mirza, O. (2017), "Anchored blind bolted composite connection to a concrete filled steel tubular column", Steel Compos. Struct., 23(1), 115-130. https://doi.org/10.12989/scs.2017.23.1.115.
  2. Beena, K., Naveen, K. and Shruti, S. (2017), "Behaviour of bolted connections in concrete-filled steel tubular beamcolumn joints", Steel Compos. Struct., 25(4), 443-456. https://doi.org/10.12989/scs.2017.25.4.443.
  3. Eurocode 3 (2005), Design of steel structures, Part 1-8:Design of joints, European Committee for Standardization (CEN), Brussels Belgium.
  4. Li, S., Li, Q., Jiang, H., Zhang, H., Yan, L. and Jiang, W. (2018), "Experimental study on a new type of assembly bolted endplate connection", Steel Compos. Struct., 26(4), 463-471. https://doi.org/10.12989/scs.2018.26.4.463.
  5. Vatansever, C. and Kutsal, K. (2018), "Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior", Steel Compos. Struct., 28(6), 767-778. https://doi.org/10.12989/scs.2018.28.6.767.
  6. ANSI/AISC 341-16 (2016), Seismic Provisions for Structural Steel Buildings, Chicago, USA.
  7. Godrich, L., Wald, F., Kabelac, J. and Kurikova, M. (2019), "Design finite element model of a bolted T-stub connection component", J. Constr. Steel Res., 157(1), 198-206. https://doi.org/10.1016/j.jcsr.2019.02.031.
  8. Piluso, V., Faella, C. and Rizzano, G. (2001), " Ultimate behavior of bolted T-stubs. I: Theoretical Model", J. Struct. Eng., 127(6), 686-693. https://doi.org/10.1061/(ASCE)0733-9445(2001)127:6(686).
  9. Barnett, T.C., Tizani, W. and Nethercot, D.A. (2001), "The practice of blind bolting connections to structural hollow sections: A review", Steel Compos. Struct., 1(1), 1-16. https://doi.org/10.12989/SCS.2001.1.1.001.
  10. Slowinski, K. and Wuwer, W. (2016), " Blind-bolted shear connections for axially compressed RHS columns strengthened with open sections", J. Constr. Steel Res., 127(1), 15-27. https://doi.org/10.1016/j.jcsr.2016.07.023.
  11. Tizani, W., Al-Mughairi, A., Owen, J.S. and Pitrakkos, T. (2012), "Rotational stiffness of a blind-bolt connection to concretefilled tubes using modified Hollo-bolt", J. Constr. Steel Res., 80(1), 317-331. https://doi.org/10.1016/j.jcsr.2012.09.024.
  12. Lee, J., Goldsworthy, H.M. and Gad, E.F. (2010), "Blind bolted Tstub connections to unfilled hollow section columns in low rise structures", J. Constr. Steel Res., 66(8-9), 981-992. https://doi.org/10.1016/j.jcsr.2010.03.016.
  13. Lee, J., Goldsworthy, H.M. and Gad, E.F. (2011), "Blind bolted moment connection to unfilled hollow section columns using extended T-stub with back face support", Eng. Struct., 33(5), 1710-1722. https://doi.org/10.1016/j.engstruct.2011.02.008.
  14. The Steel Construction Institute and The British Constructional Steelwork Association (2014), Joints in steel construction: Simple joints to Eurocode 3, Publication P358.
  15. Rumman, W., Brian, U., Wang, J. and Thai, T. (2019), "In-plane structural analysis of blind-bolted composite frames with semirigid joints", Steel Compos. Struct., 31(4), 373-385. https://doi.org/10.12989/scs.2019.31.4.373.
  16. Mirza, O. and Kaewunruen, S. (2018), "Influence of shear bolt connections on modular precast steel-concrete composites for track support structures", Steel Compos. Struct., 27(5), 647-659. https://doi.org/10.12989/scs.2018.27.5.647.
  17. France, J.E., Davison, J.B. and Kirby, P.A. (1999), "Momentcapacity and rotational stiffness of endplate connections to concrete-filled tubular columns with flowdrilled connectors", J Constr Steel Res., 50(1), 35-48. https://doi.org/10.1016/S0143-974X(98)00237-5.
  18. Liu, M., Zhu, X., Wang, P., Tuoya, W. and Hu, S. (2017), "Tension strength and design method for thread-fixed one-side bolted Tstub", Eng. Struct., 150(1), 918-33. https://doi.org/10.1016/j.engstruct.2017.07.093.
  19. Wang, P., Wulan, T., Liu, M., Qu, H. and You, Y. (2019), "Shear behavior of lap connection using one-side bolts", Eng. Struct., 186(1), 64-85. https://doi.org/10.1016/j.engstruct.2019.02.012.
  20. Song, T.Y., Tao, Z. and Razzazzadeh, A. (2017), "Fire performance of blind bolted composite beam to column joint", J. Constr. Steel Res., 132(1), 29-42. https://doi.org/10.1016/j.jcsr.2017.01.011.
  21. Schaumann, P. and Kirsch, T. (2013), "Simulation of a flush endplate connection at elevated temperatures including fracture simulation", J. Struct. Fire Eng., 4(2), 103-112. https://doi.org/10.1260/2040-2317.4.2.103.
  22. Slowikowska, A. and Polus, L. (2019), "An analysis of the resistance of an extended end-plate beam-to-beam connection subjected to tension in fire conditions", Bud. Archit., 18(1), 81-88. https://doi.org/10.24358/Bud-Arch_19_181_08.
  23. Cirpici, B.K., Orhan, S.N. and Kotan, T. (2020), "Finite element study on composite slab-beam systems under various fire exposures", Steel Compos. Struct., 37(5), 589-603. https://doi.org/10.12989/scs.2020.37.5.589.
  24. Malendowski, M., Burgess, I. and Glema, A. (2017), "Robustness in fire of a new type of beam-to-column connection", In: Ce/Papers. Eurosteel 2017, 13-15 Sep 2017, Copenhagen, Denmark. Ernst & Sohn Verlag, 550-559. https://doi.org/10.1002/cepa.92.
  25. Wang, M. and Wang, P. (2013), "Strategies to increase the robustness of endplate beam-column connections in fire" , J. Constr. Steel Res., 80(1), 109-120. https://doi.org/10.1016/j.jcsr.2012.09.017.
  26. Maslak, M., Pazdanowski, M. and Snela, M. (2020), "Ambiguity in determining the critical temperature of a steel sway frame with semi-rigid joints", Arch. Civ. Eng., 66(4), 611-632. https://doi.org/10.24425/ace.2020.135240.
  27. Cai, Y. and Young, B. (2018), "Bearing resistance design of stainless steel bolted connections at ambient and elevated temperatures", Steel Compos. Struct., 29(2), 273-286. https://doi.org/10.12989/scs.2018.29.2.273.
  28. Cai, Y. and Young, B. (2018), "Structural behavior of cold-formed stainless steel bolted connections at post-fire condition", J. Constr. Steel Res., 152(1), 312-321. https://doi.org/10.1016/j.jcsr.2018.03.024.
  29. Pascual, A.M., Romero, M.L. and Tizani, W. (2015), "Thermal behaviour of blind-bolted connections to hollow and concretefilled steel tubular columns", J. Constr. Steel Res., 107(1), 137- 149. https://doi.org/10.1016/j.jcsr.2015.01.014.
  30. Pascual, A.M., Romero, M.L. and Tizani W. (2015), " Fire performance of blind-bolted connections to concrete filled tubular columns in tension", Eng. Struct., 96(1), 111-125. https://doi.org/10.1016/j.engstruct.2015.03.067.
  31. You, Y., Liu, M., Liu, Y., Wang, P., Zhou, S. and Chen, J. (2020), "Experimental studies on thread-fixed one-side bolted Tstubs in tension at elevated temperatures", J. Constr. Steel Res., 171(1), 106139. https://doi.org/10.1016/j.jcsr.2020.106139.
  32. GB 196-2003 (2003), National Standard of People's Republic of China, General propose metric screw threads-Basic dimensions, General Administration of Quality Supervision, Beijing, China.
  33. Hu, Y., Shen, L., Nie, S., Yang, B. and Sha, W. (2016), "FE simulation and experimental tests of high-strength structural bolts under tension", J. Constr. Steel Res., 126(1), 174-186. https://doi.org/10.1016/j.jcsr.2016.07.021.
  34. Eurocode 3 (2005), Design of Steel Structures, Part 1-2:General Rules - Structural Fire Design. European Committee for Standardisation (CEN), Brussels Belgium
  35. Pang, X.P., Hu, Y., Tang, S.L., Xiang, Z., Wu, G., Xu, T. and Wang, X.-Q. (2019), "Physical properties of highstrength bolt materials at elevated temperatures", Results Phys., 13(1), 102156. https://doi.org/10.1016/j.rinp.2019.102156.