• Title/Summary/Keyword: boiler efficiency

Search Result 279, Processing Time 0.024 seconds

The Experimental Study on the Heat Transfer Characteristics (가스보일러 코일형 열교환기의 열전달 특성에 관한 실험적 연구)

  • Hong, S.H.;Kim, Y.K.;Kim, I.G.;Kim, D.C.;Lee, C.E.;Yim, C.S.
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.57-66
    • /
    • 1997
  • The performance of gas-fired boilers were experimentally investigated. The heat exchanger used for the experiments consisted of circular tube with longitudinal fins for the gas side and a spiral coil for the water side. The burner was located at the top of the heat exchanger, and the burned gas flowed down to the exit. The experiments carried out for different water flow rates, the heat capacities of the boiler and the number of baffle. The thermal efficiency of the upward flow was higher than that of the downward flow of the water in the heat exchanger. As the boiler capacity increased, the thermal efficiency decreased. As the number of the baffles increase, the thermal efficiency increased and the increasing rate of the efficiency decreased. The gas-side overall heat transfer coefficient was independent of the flow rate of the water. The effect of the number of the baffles on the heat transfer coefficient was greater than that of the boiler capacity.

  • PDF

Pellet Made of Agricultural By-product and Agricultural Pellet Boiler System (농림부산물 원료 펠릿 및 농업용 펠릿 난방기)

  • Kang, Y.K.;Ryou, Y.S.;Kcang, G.C.;Kim, J.G.;Kim, Y.H.;Jang, J.K.;Lee, H.M.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.252.2-252.2
    • /
    • 2010
  • Biomass is considered to be a major potential fuel and renewable resource for the future. In fact, there is high potential to produce the large amount of energy from biomass around the world. In this study, to obtain basic data for practical application of wood pellet and wood pellet boiler system as heating system in agriculture, agricultural biomass resources were surveyed, pellet was made of agricultural by-product such as stem of rape, oat and rice, ricehusk and sawdust and wood pellet boiler system with capacity of 116 kW was manufactured and installed in greenhouse of $38.5m{\times}32m$. High heating value, bulk density and ash content of pellet made of agricultural by-product and efficiency and heating performance of this system was estimated. Rice straw was the largest agricultural biomass in 2005 and the total amount of rice straw converted into energy of $131.71{\times}10^{11}$ kJ. And in 2005, total amount of forest' by-product converted into energy of $29,277.05{\times}10^{11}$ kJ. High heating values of pellets made of agricultural by-products of stem and seed of rape, stem of oat, rice straw and rice husk were 16,034, 16,026, 16,089, 15,650, 15,044 kJ/kg respectively. High heating values of pellets made of agricultural by-products were 83.6% compared to that of wood pellet. Average bulk density of pellets made of agricultural by-products of stem and seed of rape, stem of oat, rice straw and rice husk was 1,400 $kg/m^3$. Ash contents of the pellets were 6.6, 7.0, 6.2, 5.5, 33% respectively. Ash content of rice husk pellet was the largest compared to other kind of pellets. To increase efficiency of agricultural pellet boiler, the boiler adopted secondary heat exchanger. The agricultural pellet boiler designed and manufactured in this study had high efficiency of 84.2% compared to the conventional agricultural pellet boiler, when water flow rate, exhaust gas temperature and average combustion furnace temperature were 39L/min, $180^{\circ}C$, $680^{\circ}C$ respectively. And pellet supplying and pausing time were 13, 43 seconds respectively. In March of 2010, prices of wood pellet, agricultural tax free diesel, diesel, kerosene were 350 won/kg, 811 won/L, 1,422 won/L, 976 Won/L respectively. Also in terms of energy, prices per same heating value were 77.8, 90.1, 158, 108.4 Won/Mcal. Energy saving rate of wood pellet was 16, 50, 39% compared to agricultural tax free diesel, diesel and kerosene respectively.

  • PDF

A Study on Efficient Operations of Industrial Boilers in Korea (우리나라 산업용 보일러의 효율적 운용에 관한 연구)

  • 조흥곤
    • Journal of the Korean Professional Engineers Association
    • /
    • v.35 no.4
    • /
    • pp.68-73
    • /
    • 2002
  • Almost every industrial plant or building has their own boiler systems, so boilers are often called "kinds of social infrastructures"In Korea, We have many indistinct problems on efficient operations of industrial boiler systems. In this paper, to elevate thermal operation efficiency and to diminish air pollutions of the boilers, especially in urban area, at present, "The muliple installation systems of small type once through boiler(gas fired)" are suggested.

  • PDF

Boiler Performance Characteristics Change by UC Contents Increase for Coal Fired Power Plant (석탄연소 화력발전소에서 미연탄소분 농도 증가가 보일러 성능에 미치는 영향에 관한 연구)

  • Kim, Taehyung;Park, Byungchul
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.99-102
    • /
    • 2015
  • To operate coal fired power plant efficiently is considered unburned carbon as important factor. But, unburned carbon contents change does not have an impact on Boiler performance simultaneously. we evaluated that unburned carbon contents change had an little influence on unburned carbon loss change for performance side at a real power plant.

  • PDF

A Basic Study on Developing an Electrocharged Scrubber (전기하전식 세정집진장치 개발에 관한 기초 연구)

  • 김종호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.33-39
    • /
    • 1999
  • This study has been performed to develop an efficient electrocharged scrubber. To improve collection efficiency of the scrubber, electric-charger was installed at the forefront of the packed crossflow scrubbers, and an experiment of changing discharge electrode shape and fluctuating electric field strength was undertaken. After using a light-oil boiler for generation of particles in the about 80% weight of submicron size particles was exhausted. Collection characteristics of the electrocharged scrubber were similar to those of two-stage electrostatic precipitator. In this study the collection efficiency of submicron size particles has been much improved, compared with the previous ones. In an experiment of changing discharge electrode and electric field strength, a needle-spike shape wire electrode showed a higher collection efficiency than round shape wire. The collection efficiency becomes increased with an increase of electric field strength.

  • PDF

Adjustment of the Excess Air Ratio for Stabilizing the Draft System in a Large Capacity Coal Fired Power Plant (대형 석탄화력 발전소에서 통풍계통 안정화를 위한 과잉공기비 조정)

  • Park, Kun Woo;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.14 no.2
    • /
    • pp.39-44
    • /
    • 2018
  • In this study, I analyzed the effects on stabilizing the draft system, boiler efficiency when changing excess air ratio under 870 MW load limit operation condition in a large capacity coal fired power plant and decided optimum excess air ratio. It is positively necessary to choose adequate excess air ratio for stabilizing draft system because air pre-heater pressure drop and induced draft fan first stall margin are changing when adjusting excess air ratio. This study therefore, measured air pre-heater pressure drop, induced draft fan first stall margin, boiler efficiency, loss and has chosen adequate excess air ratio adjusting excess air ratio from 1.153 to 1.127. So it is recommended that the operation point needs to be changed to 1.127 that is not only to decrease air pre-heater pressure drop and to stabilize draft system and to secure stall margin but also to maintain boiler efficiency to equivalent level.

  • PDF

A Study on the Thermal and Pollution Performances of the Heating Boilers with NG-H2 Mixture Ratio (난방용 보일러에서 NG-H2 혼소율에 따른 열 및 공해 성능의 검토)

  • SEO, JUNSUN;KIM, YOUNG-JIC;PARK, JUNKYU;LEE, CHANG-EON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.573-584
    • /
    • 2021
  • Hydrogen is evaluated as one of the new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is CO2-free, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. However, use of electric grids is an unrealistic strategy for decarbonization for residential and commercial heating. Instead, use of H2 that utilizes city gas grid is suggested as a reasonable alternative in terms of compatibility with existing systems, economic feasibility, and accessibility. In this study, the thermal efficiency and NOx performance of the boiler according to the H2 mixture ratio and vapor humidified ratio are reviewed for a humidified NG-H2 boiler that vapor humidity to combustion air. Mixed fuel with H2 (20%) is almost similar to NG in terms of efficiency, flame temperature, and pollution performance. Thus, it is expected to be directly compatible with the existing NG system. If the exhaust temperature of the H2 boiler is lowered to around 60℃ at a humidified ratio of 15-20%, the NOx emission concentration can be suppressed to about 5-10 ppm. The level of efficiency reaches 87% of the rated load efficiency, which is equivalent to the highest grade achievable.

Assessment for the effect of heating systems on the energy consumption and environment (개별난방과 지역난방방식의 에너지절감 및 환경개선효과 분석)

  • Im, Yong-Hoon;Kim, Hyouck-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.466-473
    • /
    • 2007
  • The comparison for the performance of heating systems, district heating and separate heating and power, is carried out in terms of energy consumption and environment on the basis of real operating data. The efficiency of boiler and the heat loss within the housing are assumed with reasonable manner due to the lack of reliable data regarding those quantities. The assessment for the established criteria of previous studies is performed and the new criteria for the analysis is proposed. It is shown that the district heating system is superior to the separate heating and power system from the point of view of reduction of energy use and environment improvement. The sensitivity study for those quantities with uncertainty such as the boiler efficiency and heat loss within the housing is carried out also and the reasons for the analysis results are discussed in detail.

  • PDF

A Comparative Study on the Energy Efficiency due to the Capacity of Gas Boiler (가스온수가열기의 용량에 따른 에너지효율성 비교 연구)

  • Kim, Seong Jung;Woo, In sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.229-234
    • /
    • 2015
  • Depending on the living styles, the types of energy consumed by households have changed, and the consumption has increased rapidly. Consequently, those have led to environmental issues, such as exhaustion of energy and the climate changes. As one of solutions to such issues, energy efficiency can be approached. Therefore, in this study, the gas water heater(115S type Rheem products) that made in Germany and obtain hot water using gas as a heat source is selected. a $1.0m^3$ water tank with a 6kW electronic heater is installed and a water temperature and pressure is maintain constantly also thermometer is injected. Two of gas meter, one of pressure regulator and three of time measurement devices are installed in a combustion facility and fuelling facility with a magnet valve so it can observe and record combustion reactions. Quantity of hot water that heated by boiler is recorded using a quantity measurement tank, and have been heated by the boiler have been to record and measure the amount and utilized the data acquired through measurement of all factors that are applied to acquire hot water in order to calculate the use rate of final energy. In conclusion, this researcher drew the economic strong points of the hot water generated by gas.