• Title/Summary/Keyword: body screen

Search Result 169, Processing Time 0.028 seconds

A Simplified Dvnamic Model for a Tilting Train Simulator (틸팅 차량 모의장치개발을 위한 단순화된 철도차량 모델링)

  • Kim, Jung-Seok;Song, Young-Soo;Han, Seong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.751-755
    • /
    • 2004
  • This paper presents a simplified dynamics of railway vehicle for a tilting train simulator. The tilting train simulator has 6 electric-driven actuators and a visualization system with 1600mm-diameter dome screen. The each system shares the data by ethernet. In order to analyze the dynamics of railway vehicle and transfer the results of the analysis to the other system of the tilting train simulator in realtime base, We assumed the tilting train as a simplified rigid body model with primary and secondary suspensions. The simplified vehicle model has a 17-DOF. Through the running analysis on the tight curve with various radius, we verified the simplified vehicle model.

  • PDF

A Study On The Control Techniques Of Electra-Static Discharges Using Semiconductor Circuits (반도체 회로를 이용한 정전기제거에 관한 연구)

  • Oh, H.J.;Park, K.J.;Kim, B.I.;Kim, N.O.;kim, H.G.;Kim, D.T.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.19-24
    • /
    • 2002
  • Static electricity is an everyday phenomenon. There can be few of us who have not experienced a static shock after sliding across a car seat. Other static nuisance effects include the cling of some fabrics to the body, the sticking of a plastic document cover, or the attraction of dust to a TV or computer screen. However, static electricity has been a serious industrial problem. The age of electronics brought with it new problems associated with static electricity and electrostatic discharge. And, as electronic devices became faster and smaller, their sensitivity to ESD increased. In this work, We are study on the control technique of electo-static discharges using semiconductor circuits. Our circuits are prevented well to electrostatic shock or damages from triboelectric charging in cars everyday life.

  • PDF

Paraneoplastic demyelination in the brain presenting as a clinically occult non-Hodgkin's lymphoma

  • Son, Hyoshin;Choi, Jongsuk;Kim, Sung Un;Park, Kyung Seok
    • Annals of Clinical Neurophysiology
    • /
    • v.21 no.2
    • /
    • pp.108-112
    • /
    • 2019
  • Non-Hodgkin's lymphoma (NHL) may initially present with atypical neurological manifestations, including paraneoplastic neurological syndromes. Herein, we report the case showing an initial manifestation of systemic NHL with paraneoplastic demyelination in the brain that initially mimicked the symptoms of stroke, seizure, and brain tumor. A high index of suspicion and timely diagnostic workup is required to prevent diagnostic delay and commence proper management of the condition. In this situation, a whole-body FDG PET/CT could be useful to screen for occult malignancy.

Comparing Validity of Body Mass Index, Waist to Hip Ratio, and Waist Circumference to Cardiovascular Disease Risk Factors in Korean Elderly (한국노인에서 심장혈관계 질환 위험인자에 대한 비만지표인 체질량지수, 허리-엉덩이둘레비, 및 허리둘레의 타당도 비교)

  • Moon Hyun-Kyung;Kim Eu-Gene
    • Journal of Nutrition and Health
    • /
    • v.38 no.6
    • /
    • pp.445-454
    • /
    • 2005
  • The purpose of this study was to compare the validity of obese index among body mass index (BMI), waist to hip ratio (WHR), and waist circumference (WC) and to determine which is the best in relation to cardiovascular disease (CVD) risk in Korean elderly more than 65 ages. Data from the 1998 Korean Health and Nutrition Survey were used (n=1017). Anthropometric indices and CVD risk factors were measured, and chi-square test, analysis of variance following duncan's multiple range test, partial correlation analysis, and Receiver Operator Characteristic (ROC) curves were used in the analysis. Anthropometric values were decreased in both male and female when ages were goes up. In female elderly, it specially showed the characteristics of upper body fat and systolic blood pressure risk (p<0.05). Among life style factors the current smokers were prevalent in obese male (p<0.05), but not prevalent in female having obese or upper body fat. Also, person with upper body obesity have more exercise than that of normal group (p<0.01). Mean BMI values of the current smoker was lower than that of normal group in both sexes (p<0.01). Mean BMI value of person with other risk factors were higher than that of normal groups (p<0.05). Among 7 CVD risk factors in partial correlation analysis, WC had the highest correlation coefficient in 5 in male, whereas BMI in 4 in female. In ROC analyses of 12 risk factors and health conditions, the largest area under curve of obese indices for risk factors were WC>WHR>BMI in male and BMI>WHR>WC in female. The optimal cutoff values of each index (BMI : WHR : WC) for one or more risk factors were 19.02 : 0.84 : 71.3 in male and 19.04 : 0.88 : 85.6 in female. In conclusion, Most Korean elderly showed non-obese and abdominal obesity likewise other Asians. Also CVD risk factors were prevalent in Korean elderly within normal limits of obese indices. Therefore the upper body fat indices reflected in the aged whose muscle mass is replaced by fat must be used as an indicator of CVD risk together with BMI. Although WHR was the worst index based on partial correlation analysis and so located between BMI and WC in ROC curve analysis in both sexes, it need to be use with WC to screen the cardiovascular risk group.

The Implementation of Visualization Tool for Snowboard Using Kinect Sensor Data (키넥트 센서 데이터를 이용한 스노보드 동작 시각화 도구의 구현)

  • Park, Young-Nam;Seo, Se-Mi;Park, Myeong-Chul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.5
    • /
    • pp.53-60
    • /
    • 2013
  • This paper proposed visualization tool for motion of snowboarding using Skeleton data obtained by the Microsoft's Kinect sensor. The BBP(Balanced Body Position) posture is a most basic motion in the Snowboarding. This posture is the primary technology for stable turns. The implementation of visualization tool to analyse the BBP posture of snowboard. comparative analysis with standard postures to the ankles, knees, hips and spine angle of joints and body tracking using coordinate information obtained by the Kinect Sensor. Analysis of the final results of the screen through the OpenGL library. This research result could be used to analysis for turn postures of snowboarding.

A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography (복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구)

  • Kim, Jung-Min;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

Development and Evaluation of the V-Catch Vision System

  • Kim, Dong Keun;Cho, Yongjoo;Park, Kyoung Shin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.3
    • /
    • pp.45-52
    • /
    • 2022
  • A tangible sports game is an exercise game that uses sensors or cameras to track the user's body movements and to feel a sense of reality. Recently, VR indoor sports room systems installed to utilize tangible sports game for physical activity in schools. However, these systems primarily use screen-touch user interaction. In this research, we developed a V-Catch Vision system that uses AI image recognition technology to enable tracking of user movements in three-dimensional space rather than two-dimensional wall touch interaction. We also conducted a usability evaluation experiment to investigate the exercise effects of this system. We tried to evaluate quantitative exercise effects by measuring blood oxygen saturation level, the real-time ECG heart rate variability, and user body movement and angle change of Kinect skeleton. The experiment result showed that there was a statistically significant increase in heart rate and an increase in the amount of body movement when using the V-Catch Vision system. In the subjective evaluation, most subjects found the exercise using this system fun and satisfactory.

The Modern Perspective in Fashion Illustration (패션일러스트레이션에 나타난 현대적 원근법)

  • 박선희;유영선
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.7
    • /
    • pp.57-68
    • /
    • 2003
  • The purpose of this study is to develop a creative perspective technique in fashion illustration through analyzing perspective in visual art experienced a great variety. This study was analyzed by examining the general theories based on the discovery of perspective and investigating the modern perspective in fashion illustration related to the method of spatial expression in visual art. A complex perspective of existing perspective gives the effect of reapperance of actual space and three-dimentional form in a plane. Because of being used as not only one perspective technique but also some perspectives technique, its expression can be more realistic. An amplified perspective gives the effect of visual illusion just like being suck in space inside and come out from screen outside by distorting the human body. A confused perspective of space gives the visual illusional effect of collapsing actual space and misunderstanding three-dimensional form by distorting the form of the space and changing the nature as an object of fashion. A reiterated or duplicated perspective gives effect of interpreting invisible space as imaginary space by overlapping and eliminating the object of fashion. An irrational perspective of spatial illusion gives the effect of disorganization experienced thinking by strange shapes and new recognition of irrational space by extraordinary visual connection. It has a tendency to surrealism. In conclusion, the modern perspective in fashion illustration has made the best use of not only new perspective since 1980, but general perspective before 1980. By the modern perspective expression. the viewer has made a chance to experience imaginary spaces indirectly, and the author has been able to express emotions by his or her new attempt in the screen.

Effect of the Underwater Ai-Chi Exercise Program on Hip Joint Mobility, Body Balance and Posture Change Based on Amount of the Physical Activity of College Students (수중 Ai-Chi 운동프로그램이 신체 활동량에 따른 대상자의 엉덩관절 가동성과 자세 및 균형에 미치는 영향 )

  • Ki-Won Nam;Se-Hun Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.4
    • /
    • pp.89-96
    • /
    • 2023
  • PURPOSE: To investigate the effects of the underwater Ai-Chi exercise on the joint range of motion, balance and posture. METHODS: Thirty-six college students (30 men, 6 women) were divided into a 'low physical activity' groups (Group I). and an 'appropriate physical activity' groups (Group II). The Ai-Chi underwater exercise was conducted three times a week for two weeks for both groups. A goniometer was used to measure the range of motion of the hip joint, and Y-Balance and the posture screen mobile were used to measure the stability of the lower extremities. RESULTS: An evaluation of the range of motion of the hip joint before and after the Ai-Chi exercise showed significant results in the low physical activity group. However, the flexural range showed a significant increase after exercise, but not significant result. In the comparison of the mean increase between groups, only the right hip joint showed a significant difference in both groups. Also, in the comparison of the Y balance test and posture screen test before and after exercise, both groups showed significant. CONCLUSION: The Ai-Chi underwater exercise helped improve the range of motion of the hip joint and the ability to balance. Also It helped improve posture alignment. In addition, although the increase in all physical activity groups lower than the appropriate physical activity groups was greater in all figures, the increase in the number of samples, the extension of the experimental period, and various variables could be obtained.

Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer (피부암치료를 위한 전자선 전신피부 치료방법과 선량분포 측정)

  • Chu, Sung-Sil;Loh, John-Jk;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.107-113
    • /
    • 1992
  • Increasing frequency of skin cancer, mycosis fungoides, Kaposi's sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a $0.5\;cm\times90\;cm{\times}180\;cm$ acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around the body. One treatment session delivered 400 cGy to the entire skin surface and patients were treated twice a week for eight consecutive weeks, which is equivalent to TDF value 57. instrumentation and techniques developed in determining the depth dose, dose distribution and bremsstrahlung dose are discussed.

  • PDF