• 제목/요약/키워드: body protection

검색결과 754건 처리시간 0.032초

허리보호 코르셋 디자인을 위한 제품 분석 및 착용 평가 (Product Characteristics Assessment and Wearing Evaluation of Waist-protection Corset Design)

  • 김소영;이희란
    • 한국의류산업학회지
    • /
    • 제23권6호
    • /
    • pp.781-789
    • /
    • 2021
  • To enhance the design and comfort of waist-protection corsets, this study analyzed the product characteristics of five types of posture-correction corsets that are available commercially. Additionally, subjective evaluation of the corsets was conducted on women aged 20 to 60 years, in terms of design, material preference, fit, comfort, degree of correction, freedom of movement, tightness, and convenience of front fastening. Following product analysis, the five corset types were divided into: two soft, one semi-hard, and two hard types in terms of the degree of elongation. As a result of pattern analysis, the soft type was designed to improve fit by reflecting the body curvature, whereas the semi-hard and hard types were relatively flat. Through the wearing sensation assessment, the hard type manufactured by company S was the best in terms of design, material, fit, comfort, correction degree, and freedom of movement. The soft type was average in design, material, and fit while relatively poor in the correction degree and tightness. The results indicated that soft materials, flexible bones with appropriate tension, patterns designed to snugly fit the body with large curvature at the top and bottom for better inflection, and adjustable support belts that can be double-fixed are crucial elements in improving the corset design to boost the comfort of wearing. These study results are helpful in the development of waist-protection corsets with excellent wearing comfort and design appreciated by customers.

Personal Dosimeters Worn by Radiation Workers in Korea: Actual Condition and Consideration of Their Proper Application for Radiation Protection

  • Eunbi Noh;Dalnim Lee;Sunhoo Park;Songwon Seo
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.162-166
    • /
    • 2023
  • Background: Assessment of the radiation doses to which workers are exposed can differ depending on the placement of dosimeters on the body. In addition, it is affected by whether the placement is under or over a shielding apron. This study aimed to evaluate the actual positioning of personal dosimeters on the body, with or without shielding aprons, among radiation workers in Korea. Materials and Methods: We analyzed the survey data, which included demographic characteristics, such as sex, age, occupation, work history, and placement of the personal dosimeter being worn, from a cohort study of Korean radiation workers. We assessed the use of personal dosimeters among workers, stratified by sex, age, working period, starting year of work, and occupation. Results and Discussion: Overall, high compliance (89.1% to 99.0%) with the wearing of dosimeters on the chest was observed regardless of workers' characteristics, such as age, sex, occupation, and work history. However, the placement of dosimeters, either under or over the shielding aprons, was inconsistent. Overall, 40.1% of workers wore dosimeters under their aprons, while the others wore dosimeters over their aprons. This inconsistency indicates that radiation doses are possibly measured differently under the same exposure conditions solely owing to variations in the placement of worn dosimeters. Conclusion: Although a lack of uniformity in dosimeter placement when wearing a shielding apron may not cause serious harm in radiation dose management for workers, the development of detailed guidelines for dosimeter placement may improve the accuracy of dose assessment.

직물의 자외선 방어율에 따른 인체의 Vit. $D_3$ 합성과 온열생리적인 반응

  • 송명견;안령미;신정화
    • 한국의류학회지
    • /
    • 제23권7호
    • /
    • pp.980-986
    • /
    • 1999
  • This study was done to ivestigate the fabrics thatminimized harmfulness of UVB(ultraviolet B) and that might product Vit. {{{{ {D }`_{3 } ^{ } }} by UVB. Twelve female subjects wearing in three different types i.e fabric A(UVB 100% protection) fabric B(UVB 50% protection) and bikinii were exposed to outdoor environment (Air Temp : 25℃, 42% R,H Air velocity : 0.13m/s UV does :6KJ/m2) Blood samples were taken 24 hours before the after the experiment in order to examine concentration of vit.{{{{ {D }`_{3 } ^{ } }} in the blood. During the experiment axillary temperature skin temperature of 7 areas(forehead Chest Upper arm, Hand Thigh Lower leg, Foot) were measured. The more irradiated areas by UVB were the more the concentration of serum 25(OH){{{{ {D }`_{3 } ^{ } }} were significantly. Mean skin temperature was significantly low levekl in wearing the fabric of UVB 50% protection (p<0.001) Axillary temperature was significantly high level in wearing the fabric of UVB 50% protection (p<0.001). Therefore the fabric of UVB 50% protection intercepts the radiation and has advantage to give off body heat over other fabrics

  • PDF

Synergistic effect of ribavirin and vaccine for protection during early infection stage of foot-and-mouth disease

  • Choi, Joo-Hyung;Jeong, Kwiwan;Kim, Su-Mi;Ko, Mi-Kyeong;You, Su-Hwa;Lyoo, Young S.;Kim, Byounghan;Ku, Jin-Mo;Park, Jong-Hyeon
    • Journal of Veterinary Science
    • /
    • 제19권6호
    • /
    • pp.788-797
    • /
    • 2018
  • In many countries, vaccines are used for the prevention of foot-and-mouth disease (FMD). However, because there is no protection against FMD immediately after vaccination, research and development on antiviral agents is being conducted to induce protection until immunological competence is produced. This study tested whether well-known chemicals used as RNA virus treatment agents had inhibitory effects on FMD viruses (FMDVs) and demonstrated that ribavirin showed antiviral effects against FMDV in vitro/in vivo. In addition, it was observed that combining the administration of the antiviral agents orally and complementary therapy with vaccines synergistically enhanced antiviral activity and preserved the survival rate and body weight in the experimental animals. Antiviral agents mixed with an adjuvant were inoculated intramuscularly along with the vaccines, thereby inhibiting virus replication after injection and verifying that it was possible to induce early protection against viral infection prior to immunity being achieved through the vaccine. Finally, pigs treated with antiviral agents and vaccines showed no clinical signs and had low virus excretion. Based on these results, it is expected that this combined approach could be a therapeutic and preventive treatment for early protection against FMD.

인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석 (The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current)

  • 김재현;임용배;이상익;김동우
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • 제14권4호
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.

Reference Electrode for Monitoring Cathodic Protection Potential

  • Panossian, Z.;Abud, S.E.
    • Corrosion Science and Technology
    • /
    • 제16권5호
    • /
    • pp.227-234
    • /
    • 2017
  • Reference electrodes are generally implemented for the purpose of monitoring the cathodic protection potentials of buried or immersed metallic structures. In the market, many types of reference electrodes are available for this purpose, such as saturated calomel, silver/silver chloride and copper/copper sulfate. These electrodes contain a porous ceramic junction plate situated in the cylindrical body bottom to permit ionic flux between the internal electrolyte (of the reference electrode) and the external electrolyte. In this work, the copper/copper sulfate reference electrode was modified by replacing the porous ceramic junction plate for a metallic platinum wire. The main purpose of this modification was to avoid the ion copper transport from coming from the inner reference electrode solution into the surrounding electrolyte, and to mitigate the copper plating on the coupon surfaces. Lab tests were performed in order to compare the performance of the two mentioned reference electrodes. We verified that the experimental errors associated with the measurements conducted with developed reference electrode would be negligible, as the platinum surface area exposed to the surrounding electrolyte and/or to the reference electrolyte are maintained as small as possible.

개에서 자해방지를 위해 사용되는 목칼라들에 관한 비교연구 (Comparative Study on the Neck Collars Used for the Protection of Self-mutilation in Dogs)

  • 홍성혁;이기창;권오경;남치주
    • 한국임상수의학회지
    • /
    • 제9권2호
    • /
    • pp.367-372
    • /
    • 1992
  • To investigate the effect of neck collars for the protection of self-mutilation, attainable sites of the body in dogs with collars and durability of collars were examined for 7 days. The collars used in the present experiment were hand made plastic basket collar, IASIS$\^$R/ ( heat moldable plastics), commerical plastic and cardboard collars The hand made plastic basket collar was made of basket which could buy at any supermarkets. The dogs with hand made plastic basket collar and IASIS$\^$R/ which was cast from the neck to the scapular region could lick only on digits of the forelimb. However, the dogs with commercial plastic and cardboard collars could lick not only the digits of forelimb but femur and digits of the hindlimb. It was suggested that hand made plastic basket collar was superior to the other collars in easiness of putting, durability, protection of self mutilation and economy.

  • PDF

직교배열표를 이용한 승객보호장구의 설계 (Design Recommendations of the Occupant Protection Systems Using Orthogonal Arrays)

  • 임재문;박경진
    • 한국자동차공학회논문집
    • /
    • 제7권8호
    • /
    • pp.208-215
    • /
    • 1999
  • Using the orthogonal arrays and the occupant analysis software based on the multi-body dynamics , two interactive design algorithms are proposed to improve the initial design of the occupant protection systems. Algorithm 1 sequentially moves the narrow design space within the upper and the lower design limit. Algorithm 2 sequentially reduces the relatively wide design space. Each design algorithm is composed of two levels . The first level is to improve the characteristics of the crash performance considering the noise factors. In order to obtain the robust design, the second level reduces the variations the noise factors. In order to obtain the robust design, the second level reduces the variations due to the tolerance of the design variable. To utilize the algorithm 1, HIC(Head Injury Criterion) , 3 msec criterion value of the chest acceleration and the femur load decreased by 27.4%, 10.4% and 55.8%, respectively. To utilizer the algorithm 2 , the results decreased by 38.0%, 10.5% and 3.0% , respectively.

  • PDF

이동식 천막형 일광차단장비의 개발 (Development of Movable Sunshade Tent)

  • 김경수;최정화
    • 대한가정학회지
    • /
    • 제42권1호
    • /
    • pp.99-113
    • /
    • 2004
  • To protect farmers from solar radiation and UV, the movable sunshade tent was designed and its protection efficiency was measured in the artificial chamber and outdoors. Sunshade tent and the existing farmer's hat were examined. The results were as followes; Heart rate, total body weight loss and temperature of clothing microclimate on the chest and the back were lower in using sunshade tent than those in wearing existing hat in two experiments. In subjective sensation, subjects answered to feel significantly hotter and more uncomfortable in wearing existing hat in two experiments. Rectal temperature was significantly lower using the sunshade hat in experiment at outdoors(p<0.001).