• Title/Summary/Keyword: body profile

Search Result 753, Processing Time 0.025 seconds

Design of a Planar Antenna with Monopole-like Radiation Pattern for On-Body Communications (수직 모노폴 방사패턴을 갖는 인체표면 통신용 평면형 안테나 설계)

  • Kwon, Jaekwang;Woo, Seungmin;Tak, Jinpil;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.4
    • /
    • pp.365-373
    • /
    • 2015
  • In this paper, a planar antenna with monopole-like radiation pattern for on-body communications is proposed. The proposed antenna consists of three split-rings(SR) to generate a monopole-like radiation characteristic. To account for the on-body application, the proposed antenna is designed to have a low-profile. The antenna has an overall dimensions of $0.29{\lambda}_0{\times}0.29{\lambda}_0{\times}0.008{\lambda}_0$ at 5.8 GHz industrial, scientific, and medical(ISM) band(5.725~5.875 GHz). To verify the body effect, a two-thirds muscle equivalent semi solid phantom is fabricated and used to measure the antenna performance. The 10-dB return loss bandwidth is 280 MHz(5.68~5.96 GHz) and the measured peak gain is 1.91 dBi.

Changes in the Nutrition Status of Elderly Females in Health Promotion Programs of Health Centers in Chungbuk Province (충북 일부지역 보건소 건강증진프로그램에 참여한 여자 노인의 영양상태 변화)

  • Kim, Myoung-Sook
    • The Korean Journal of Community Living Science
    • /
    • v.26 no.2
    • /
    • pp.225-236
    • /
    • 2015
  • Materials for nutrition education to promote nutrition intake and prevent diseases in elderly individuals were developed, nutrition education was provided to 46 elderly females for 12 weeks, and its effects on the body composition, blood profile, and nutritional quality of subjects were qualitatively analyzed. After the education program, the weight of subjects decreased from 56.7 kg to 56.0 kg (p<0.001), their body fat dropped from 20.8 kg to 19.6 kg (p<0.01), their body mass index (BMI) declined from $25.2kg/m^2$ to $24.9kg/m^2$ (p<0.01), and their percentage of body fat decreased significantly (p<0.05). On the other hand, blood sugar showed a significant increase from 131.6 mg/dl to 141.8 mg/dl (p<0.05). Overall, the percentage of nutrition intake rose. In particular, the estimated energy requirement increased from 89.3% to 99.5% (p<0.05). Further, the contrast ratio of recommended intake showed significant increases in protein (p<0.01), phosphorus (p<0.05), vitamin $B_2$ (p<0.05), vitamin $B_6$ (p<0.05), and niacin(p<0.001), and that of adequate intake showed a significant increase in sodium (p<0.05). The nutrient adequacy ratio (NAR) showed a significant increase only in niacin (p<0.05), and the index of nutritional quality (INQ) showed significant increases in protein (p<0.05) and niacin (p<0.001). After the nutrition education program, a qualitative analysis of nutrients consumed by subjects was conducted. The results show improvements across the board except for the deficient intake of calcium and folic acid, suggesting that the nutrition status of subjects changed in a positive direction through the program. The implementation of this program for elderly individuals in a continuous and repetitive manner is expected to facilitate their nutrition management.

The Associations of Percent Body Fat with Dietary Intake, Plasma Lipids, Lipoprotein(a), and PAI-1 in Middle Aged Korean Adults

  • Kim Rim, Jean-Chinock;Kang, Soon-Ah;Hiojung Wee
    • Korean Journal of Community Nutrition
    • /
    • v.3 no.5
    • /
    • pp.695-706
    • /
    • 1998
  • This study was designed to investigate the associations of the percent body fat dietary intake, plasma lipoprotein profile, lipoprotein(a), and plasminogen activator inhibitor-1(PAI-1) concentrations of 1982 Korean subjects(men : 1000 and women : 982) between the ages of 40 and 59 years. The dietary assessment consisted of twenty-four hour dietary records and food frequency questionnaires. The subjects were identified into one of the five rating groups of % body fat : lean, underweight, normal, overweight and obese groups. The biochemical assessment included measurements of plasma total cholesterol(TC), HDL-cholesterol(HDL-C), LDL-cholesterol(LDL-C), triglyceride(TG), lipoprotein(a)(Lp(a)), and PAI-1. With respect to the ratio of percent energy intake of carbohydrate : protein : fat of the normal group of the women was 62% : 17% : 20%, respectively. Women apparently had a higher intake of carbohydrates than men(52% : 17 : 20%) did. There was a linear relationship between energy intake and % body fat in both mean and women(with the exception of the underweight group of women). The relationship of % body fat of men to the protein and fat intake was higher than that of the carbohydrate intake. Of the men in the study, intakes of energy, protein and alcohol were positively correlated to % body fat. In women, energy, carbohydrate and protein intake were positively correlated to % body fat, however, the fat, cholesterol and alcohol intake did not show any correlation to the % body fat in women. This study showed that % body fat was positively correlated with plasma TC, LDL-C, PAI-1 levels, and TG, but the % body fat was negatively correlated with plasma HDL-C level in both men and women. These results indicated that the high energy intake of obese or overweight subjects might contribute to several of the biochemical indices fo coronary heart disease(CHD) risk. In conclusion, increased energy intake is associated with overweight or obesity in middle aged Korean people. There was no relationship between % energy intake of fat and % body fat in the study, in middle-aged Korean men and women. The plasma lipid profile and PAI-1 level thought to be the risk factors of CHD were positively associated with percent body fat in middle aged Korean people.

  • PDF

Application and Analysis of Field Test and Geophysical Exploration for Dynamic Material Properties of Rockfill Dam (사력댐 동적물성 추정을 위한 현장조사기법 적용 및 분석)

  • Lee, Jong-Wook;Kim, Ki-Young;Jeon, Je-Sung;Cho, Sung-Eun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.352-359
    • /
    • 2005
  • In this study, seismic refraction survey and MASW at dam crest and down-hole test and cross hole test in the boring holes located in dam crest through the core are performed to fin out dynamic material properties, are needed to evaluate dynamic safety of rockfill dam using dynamic analysis method. From the field test and geophysical exploration, applied such as above, p-wave and s-wave velocity profile of each layer of dam body. Dynamic material properties, such as elastic modulus, shear modulus, poissong's ration, are obtained from p-wave and s-wave velocity profile and density profile from formation density logging test.

  • PDF

Gene Expression Analysis of Acetaminophen-induced Liver Toxicity in Rat (아세트아미노펜에 의해 간손상이 유발된 랫드의 유전자 발현 분석)

  • Chung, Hee-Kyoung
    • Toxicological Research
    • /
    • v.22 no.4
    • /
    • pp.323-328
    • /
    • 2006
  • Global gene expression profile was analyzed by microarray analysis of rat liver RNA after acute acetaminophen (APAP) administration. A single dose of 1g/kg body weight of APAP was given orally, and the liver samples were obtained after 24, 48 h, and 2 weeks. Histopathologic and biochemical studies enabled the classification of the APAP effect into injury (24 and 48 h) and regeneration (2 weeks) stages. The expression levels of 4900 clones on a custom rat gene microarray were analyzed and 484 clones were differentially expressed with more than a 1.625-fold difference(which equals 0.7 in log2 scale) at one or more time points. Two hundred ninety seven clones were classified as injury-specific clones, while 149 clones as regeneration-specific ones. Characteristic gene expression profiles could be associated with APAP-induced gene expression changes in lipid metabolism, stress response, and protein metabolism. We established a global gene expression profile utilizing microarray analysis in rat liver upon acute APAP administration with a full chronological profile that not only covers injury stage but also later point of regeneration stage.

u-Healthcare Monitoring System Design using by Smartphone based on Bluetooth Health Device Profile (Bluetooth Health Device Profile기반 스마트폰을 이용한 u-Healthcare 모니터링 시스템 설계)

  • Cho, Kyoung-Lae;Kim, Sang-Yoon;Kim, Jung-Han;Oh, Am-Suk;Kim, Gwan-Hyung;Jean, Jae-Hwan;Kang, Sung-In
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.6
    • /
    • pp.1365-1369
    • /
    • 2013
  • Recently, the Personal Health Device(PHD) that measures various biometric data easily are highlighted for ensuring portability, scalability and interoperability among the device as well as needs for a standardization of managing information measured by. In this paper, we'd like to propose u-healthcare monitoring system that measure biometric data(Oxygen saturation, Body weight, ECG and Blood pressure) by PHD featured with transferring data into devices such as smartphone using Bluetooth Health Device Profile(HDP) based on the ISO/IEEE 11073.

Flatness Control System of the Hot Strip by Using Tension Profile between Stands (스탠드간 장력프로파일을 이용한 열연판 평탄도 제어시스템)

  • 홍완기;이준정
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.27-36
    • /
    • 1999
  • To have high flatness quality of hot rolled strip in the hot strip finishing mill train, a new inter-stand tension profile measuring device of segmented looper roll type(coined as Flatness Sensing Inter-stand Looper, FlatSIL) and a new flatness control system have been developed in this study. The device measures the strip tension profile across the strip width and informs the strip wave pattern to new flatness control system where work roll bending mode to relieve the strip wave is determined. The existing automatic shape control system which uses laser type shape-meter installed at the outlet of the last finishing mill stand strip tension between down coiler and last finishig mill since the latent wave concealed by the strip tension between down coiler and last finishing mill stand cannot be measured by the laser distance-meter. Thus the existing shape control system is not able to control the flatness through the full strip length. The new flatness control system, however, works for full strip length during strip rolling as far as the tension profile measuring device and work roll bender are on. With the new flatness control system, work roll bender is automatically controller to minimize the latent wave of the running strip and the flatness quality as well as strip travelling stability has been noticeably improved from strip head through body to tail.

  • PDF

Effects of Feeding Charcoal Powder and Vitamin A on Growth Performance, Serum Profile and Carcass Characteristics of Fattening Hanwoo Steers (활성탄과 비타민 A의 급여가 거세 한우의 성장, 혈액성상 및 도체 특성에 미치는 영향)

  • Kim, B.K.;Kim, Y.J.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.2
    • /
    • pp.233-242
    • /
    • 2005
  • Effects of supplemental charcoal powder and vitamin A on growth performance, serum profile and carcass characteristics with 24 Hanwoo steers were inves$\ell$ated. The Hanwoo steers were randomly assigned to one of the three dietary treatments: 1) Control(commercial feed), 2) Tl(commercial feed supplemented with 2% charcoal powder and 0.2 % vitamin A), 3) T2(commercial feed with 2 % charcoal powder). In the age 26 month, body weight of control Tl and T2 were 633.8 kg, 621.0 kg, 619.4 kg, respectively, with not significantly different(P> 0.05). The daily weight gain of control was the highest followed by Tl and T2. The contents of vitamin A(retinol) and total cholesterol in the blood of Tl was higher Tl(56.32 $\ell$ / dt, 163.83 mg/ dz) than the other treatment groups(P < 0.05). The average of WBC value in the blood was 6.86-" 9.83 k / ${\mu}\ell$, RBC value was 7.98 - 11.26 k / ${\mu}\ell$ and blood platelet was 236.7 - 287.0 k / ${\mu}\ell$. But The serum profile in blood was not significantly different between control and treatment groups. The carcass grade and characteristics of all treatments in Hanwoo steers were not significantly different except the texture.

Clinical Feasibility of Wearable Robot Orthosis on Gait and Balance Ability for Stroke Rehabilitation: A Case Study

  • Shin, Young-Il;Yang, Seong-Hwa;Kim, Jin-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.2
    • /
    • pp.124-127
    • /
    • 2015
  • Purpose: The emphasis on gait rehabilitation after stroke depends on training support through the lower limbs, balance of body mass over the changing base of support. However, muscle weakness, lack of control of lower limb, and poor balance can interfere with training after stroke. For this case study report, a wearable robot orthosis was applied to stroke patients in order to verify its actual applicability on balance and gait ability in the clinical field. Methods: Two stroke patients participated in the training using the wearable robot orthosis. Wearable robot orthosis provides patient-initiated active assistance contraction during training. Training includes weight shift training, standing up and sitting down, ground walking, and stair up and down Training was applied a total of 20 times, five times a week for 4 weeks, for 30 minutes a day. Gait ability was determined by Stance phase symmetry profile, Swing phase symmetry profile, and velocity using the GAITRite system. Balance ability was measured using the Biodex balance system. Results: Subjects 1, 2 showed improved gait and balance ability with mean individual improvement of 72.4% for velocity, 19.4% for stance phase symmetry profile, 9.6% for swing phase symmetry profile, and 13.6% for balance ability. Conclusion: Training utilizing a wearable robot orthosis can be useful for improvement of the gait and balance ability of stroke patients.

Design Consideration of Body-Tied FinFETs (${\Omega}$ MOSFETs) Implemented on Bulk Si Wafers

  • Han, Kyoung-Rok;Choi, Byung-Gil;Lee, Jong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.1
    • /
    • pp.12-17
    • /
    • 2004
  • The body-tied FinFETs (bulk FinFETs) implemented on bulk Si substrate were characterized through 3-dimensional device simulation. By controlling the doping profile along the vertical fin body, the bulk FinFETs can be scaled down to sub-30 nm. Device characteristics with the body shape were also shown. At a contact resistivity of $1{\times}10^{-7}\;{\Omega}\;cm^2$, the device with side metal contact of fin source/drain showed higher drain current by about two. The C-V results were also shown for the first time.