• 제목/요약/키워드: body pressure detection

검색결과 42건 처리시간 0.024초

고안전 에어백의 승객 분류를 위한 체압감지 센서를 위한 알고리즘 개발 (Algorithm development of a body pressure detection sensor for the occupant classification system)

  • 윤득선;오성록;송정훈;김병수;부광석
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.385-392
    • /
    • 2009
  • This paper describes the algorithm development of a new body pressure detection sensor for occupant classification system. U.S. Government has required that advanced airbag system should be installed to every automobiles after 2006 according to FMVSS 208 regulation. Therefore, Occupant Classification System should be provided the passenger with safety in order to protect the infants or children that sit in the front passenger seat. When an occupant sits on the chair of the vehicle, deployment of the airbag depends on passenger's weigh distribution and postures. Authors have been developed a new pattern recognition of passenger and weight distribution at the same time by Force Sensing Resistor for the safety.

Design of Improved Detection Instrumentation for the Annulus Gas System for Wolsong 2

  • Kim, Seog-Nam;Koo, Jun-Mo;Chang, Ik-Ho;Jung, Ho-Chang;Han, Sang-Joon
    • Nuclear Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.423-430
    • /
    • 1996
  • The improved and advanced Annulus Gas System(AGS) has been developed for Wolsong 2 to satisfy the requirements of the regulatory body. The Atomic Energy Control Board(AECB) required a shorter detection time following a small leak from a pressure tube and/or calandria tube. This paper describes licensing requirements, functional requirements and detail design description for the AGS. The Wolsong unit No. 1 AGS was designed to operate as a stagnant system normally requiring only pressure regulation and having provisions for purging. no improved AGS involves the adoption of gas recirculation in AGS, duplication of dew point indicators with additional instrumentation and sampling provisions to prompt operator action. The improved system operates in the recirculation mode with continuous dew point measurement for leak detection. An AGS with improved detection instrumentation is provided.

  • PDF

Force Sensing Resistor를 이용한 인체압력중심 변화 분석 (Center of Pressure of a Human Body using Force Sensing Resistor)

  • 박철;박신석;김충현
    • 전기학회논문지
    • /
    • 제63권12호
    • /
    • pp.1722-1725
    • /
    • 2014
  • An experimental investigation of COP(center of pressure) was performed using FSR(force sensing resistor) and force plate. The FSR sensor system is used as effective device to detect the movement of human body in activities of daily living. It has been shown that the FSR provides the trajectories of COP with repeatability and reliability.

기울기 센서와 압력 센서를 이용한 전동 킥보드용 다인승 감지 방안 (Multiuser Detection of Electric Scooter Using Tilt and Pressure Sensors)

  • 안문정;김지아;이지훈
    • 반도체디스플레이기술학회지
    • /
    • 제23권2호
    • /
    • pp.28-32
    • /
    • 2024
  • The personal mobility Sharing service is currently active. Especially, electric scooters are widely utilized because they can move comfortably at a high speed over a short distance with a simple driving method. Its driving method is easy, but there is no protection device to protect the bare body. So, there is a greater accident than other means of transportation, and if two people are on board, there is higher accident probability. However, since there is no specific ways to prevent multi-person boarding yet, we propose a multi-person boarding detection model using tilt and pressure sensor. The proposed method measures the tilt degree and direction by using a tilt sensor installed in the center of the board plate and detects multi-people riding.

  • PDF

혈압에 따른 골밀도와 체질량 지수와의 상관관계 연구 (A Study on Correlation between the Blood Pressure and Bone Mineral Density or Body Mass Index)

  • 주정용;송범용;육태한
    • Journal of Acupuncture Research
    • /
    • 제26권5호
    • /
    • pp.1-10
    • /
    • 2009
  • Objectives : This study was conducted to investigate how Bone Mineral Density(BMD) and bone mass index(BMI) differ according to classification of blood pressure which JNC 7(The seventh report of the joint national committee on prevention, detection, evaluation and treatment of high blood pressure) indicated. Methods : We measured BMD and BMI of lumbar spine($L_2-L_4$) and femoral neck of 9816 people, and then we analyzed them according to classification of blood pressure. Results : The number of prehypertension group was the most, and Stage 2 hypertension group was the least. As the hypertension was increasing, BMD of lumbar and femoral neck were decreasing, and BMI was increasing. In men, as the blood pressure was increasing, BMI was increasing. But the BMD was irrelevant. In women, the distribution was similar to the total. Conclusions : As the hypertension was increasing, BMI was increasing and BMD was decreasing. And it was more remarkable in women.

  • PDF

압박 궤양 수술 후 발생된 페색전증 치험례 (Clinical Experience of Pulmonary Embolism after Coverage of Pressure Sore)

  • 서상우;이원재;탁관철
    • Archives of Plastic Surgery
    • /
    • 제32권4호
    • /
    • pp.543-546
    • /
    • 2005
  • Pulmonary embolism is a one of the major cause of postoperative death. Surgery predisposes patients to pulmonary embolism, even as late as one month after the operation. The accurate detection of pulmonary embolism remains difficult, and the differential diagnosis is extensive. The prevention of pulmonary embolism is thus of paramount importance. We report a case of pulmonary embolism after coverage of pressure sore on the left ischium on the 8th day after operation. The patient was 60 years old, a severe smoker, in the high quantity of body mass index and had hypertension. The risk factors are 60 years of age or older who were in the highest quantity of body mass index. Heavy cigarette smoking and high blood pressure are also identified as risk factors. Plastic surgeons should keep the probability of pulmonary embolism development after operation in mind. When taking history, the risk factors should be checked certainly. The immobilization may explain the probability of pulmonary embolism development. Therefore absolute bed rest or positional maintenance should be avoided. Until recently, low molecular weight heparin has been used for preoperative prophylaxis. Plastic surgeons should be concerned in low molecular weight heparin for prophylaxis of the pulmonary embolism and study the indications and effectiveness in liposuction or abdominoplasty.

40, 50대 여성 비만도와 연령 별 대사증후군 위험인자 비교 (Comparison of the Metabolic Syndrome Risk Factor Prevalence Forty and Fifty Something Women)

  • 김희승;오정아
    • 대한간호학회지
    • /
    • 제37권4호
    • /
    • pp.453-458
    • /
    • 2007
  • Purpose: The purpose of this study was to compare metabolic syndrome (MS) risk factor prevalence by obesity and age in middle-aged women. Method: Two hundred and fifty-one subjects were recruited from the health promotion center of a tertiary care hospital in an urban city. MS was defined by the third report of the national cholesterol education program (NCEP) expert panel on detection, evaluation, and treatment of high blood cholesterol in adults(Adult Treatment Panel III)(ATP III), and obesity was determined by body mass $index(BMI){\geq}25kg/m^2$. Results: The mean blood pressure, fasting glucose, total cholesterol, and triglyceride were significantly higher in the obese group than in the non-obese group. The prevalence of MS, hypertension, and impaired fasting glucose were significantly higher in the obese group than in the non-obese group. In the forties, blood pressure was significantly higher in the obese group than in the non-obese group. In the fifties, body fat, systolic blood pressure, fasting glucose, total cholesterol, and triglyceride were significantly higher in the obese group than in the non-obese group. Conclusions: These results show that the nurse should focus on the obese fifty year old female patients for improvement of the MS risk factors.

Suction Detection in Left Ventricular Assist System: Data Fusion Approach

  • Park, Seongjin
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권3호
    • /
    • pp.368-375
    • /
    • 2003
  • Data fusion approach is investigated to avoid suction in the left ventricular assist system (LVAS) using a nonpulsatile pump. LVAS requires careful control of pump speed to support the heart while preventing suction in the left ventricle and providing proper cardiac output at adequate perfusion pressure to the body. Since the implanted sensors are usually unreliable for long-term use, a sensorless approach is adopted to detect suction. The pump model is developed to provide the load coefficient as a necessary signal to the data fusion system without the implanted sensors. The load coefficient of the pump mimics the pulsatility property of the actual pump flow and provides more comparable information than the pump flow after suction occurs. Four signals are generated from the load coefficient as inputs to the data fusion system for suction detection and a neural fuzzy method is implemented to construct the data fusion system. The data fusion approach has a good ability to classify suction status and it can also be used to design a controller for LVAS.

갈륨 미세입자 탄성 복합체 기반 고민감도와 광대역폭을 갖는 가변 강성 압력센서 (Adaptive Pressure Sensor with High Sensitivity and Large Bandwidth Based on Gallium Microdroplet-elastomer Composite)

  • 이시목;변상혁;스티브박;심주용;정재웅
    • 센서학회지
    • /
    • 제31권6호
    • /
    • pp.423-427
    • /
    • 2022
  • A pressure sensor that mimics the sensing ability of human skin has emerged as high-profile technology because it shows remarkable applications in numerous fields such as robotics, human health monitoring, and artificial prosthetics. Whereas recent pressure sensors have achieved high sensitivity similar to that of human skin, they still show limited detection bandwidth. Moreover, once these e-skin are fabricated, their sensitivity and stiffness are fixed; therefore, they can be used for only limited applications. Our study proposes a new adaptive pressure sensor built with uniform gallium microdroplet-elastomer composite. Based on the phase transition of gallium microdroplets, the proposed sensor undergoes mode transformation, enabling it to have a higher sensitivity and wider detection bandwidth compared with those of human skin. In addition, we succeeded in extending a single adaptive pressure sensor to sensor arrays based on its high uniformity, reproducibility, and large-scale manufacturability. Finally, we designed an adaptive e-skin with the sensor array and demonstrated its applications on health monitoring tasks including blood pulse and body weight measurements.

인체 삽입용 LC 공진형 혈압 센서 디자인 및 제작 (Design and Fabrication of Implantable LC Resonant Blood Pressure Sensor)

  • 김진태;김성일;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제26권3호
    • /
    • pp.171-176
    • /
    • 2013
  • In this paper, we present a MEMS (micro-electro-mechanical system) implantable blood pressure sensor which has designed and fabricated with consideration of size, design flexibility, and wireless detection. Mechanical and electrical characterizations of the sensor were obtained by mathematical analysis and computer aided simulation. The sensor is composed of two coils and a air gap capacitor formed by separation of the coils. Therefore, the sensor produces its resonant frequency which is changed by external pressure variation. This frequency movement is detected by inductive coupling between the sensor and an external antenna coil. Theoretically analyzed resonant frequency of the sensor under 760 mmHg was calculated to 269.556 MHz. Fused silica was selected as sensor material with consideration of chemical and electrical reaction of human body to the material. $2mm{\times}5mm{\times}0.5mm$ pressure sensors fitted to radial artery were fabricated on the substrates by consecutive microfabrication processes: sputtering, etching, photolithography, direct bonding and laser welding. Resonant frequencies of the fabricated sensors were in the range of 269~284 MHz under 760 mmHg pressure.