• Title/Summary/Keyword: body image

Search Result 2,310, Processing Time 0.036 seconds

A study on the status of dietary behavior and nutrient intakes according to the gender and the level of physical activity of adolescents: using the 7th (2017-2018) Korea National Health and Nutrition Examination Survey (청소년의 성별과 신체활동 수준에 따른 식행동 및 영양섭취실태: 제7기 2,3차년도 (2017-2018년) 국민건강영양조사 자료 이용)

  • Seo Yeon Kim;Sun A Choi;Jeong Ok Rho
    • Journal of Nutrition and Health
    • /
    • v.56 no.6
    • /
    • pp.683-701
    • /
    • 2023
  • Purpose: The purpose of the study was to analyze the status of dietary behavior and nutrition intakes according to the gender and the level of physical activity of adolescents. Methods: Data from 659 adolescents aged 13 to 18 years who participated in the Korea National Health and Nutrition Examination Survey (2017-2018) were analyzed. Collected data were analyzed using complex sampling data analysis with SPSS v. 27.0. Results: The adolescents were categorized into three groups based on their physical activity as follows: The first group with high physical activity (8.9%), a second group with normal physical activity (29.7%), and a third group without physical activity (61.4%). Boys showed significantly higher physical activity than the girls. Adolescents with high physical activity had a significantly lower body mass index than adolescents without physical activity, but their meal regularity, subjective health status, and recognition of body image were significantly higher. In terms of biochemical factors, adolescents with high physical activity had lower triglycerides and cholesterol than adolescents without physical activity, while hemoglobin and hematocrit were significantly higher. In addition, the intakes of energy, carbohydrates, proteins, fat, vitamin B1, niacin, calcium, phosphorus, sodium, potassium, iron increased significantly as adolescents' physical activity increased. Conclusion: The physical activity of adolescents had a positive effect on dietary behavior, lifestyle, and nutritional factors. Therefore, it is necessary to increase participation in physical classes in schools and develop various programs considering the level of physical activity among adolescents.

Contrast Media in Abdominal Computed Tomography: Optimization of Delivery Methods

  • Joon Koo Han;Byung Ihn Choi;Ah Young Kim;Soo Jung Kim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2001
  • Objective: To provide a systematic overview of the effects of various parameters on contrast enhancement within the same population, an animal experiment as well as a computer-aided simulation study was performed. Materials and Methods: In an animal experiment, single-level dynamic CT through the liver was performed at 5-second intervals just after the injection of contrast medium for 3 minutes. Combinations of three different amounts (1, 2, 3 mL/kg), concentrations (150, 200, 300 mgI/mL), and injection rates (0.5, 1, 2 mL/sec) were used. The CT number of the aorta (A), portal vein (P) and liver (L) was measured in each image, and time-attenuation curves for A, P and L were thus obtained. The degree of maximum enhancement (Imax) and time to reach peak enhancement (Tmax) of A, P and L were determined, and times to equilibrium (Teq) were analyzed. In the computed-aided simulation model, a program based on the amount, flow, and diffusion coefficient of body fluid in various compartments of the human body was designed. The input variables were the concentrations, volumes and injection rates of the contrast media used. The program generated the time-attenuation curves of A, P and L, as well as liver-to-hepatocellular carcinoma (HCC) contrast curves. On each curve, we calculated and plotted the optimal temporal window (time period above the lower threshold, which in this experiment was 10 Hounsfield units), the total area under the curve above the lower threshold, and the area within the optimal range. Results: A. Animal Experiment: At a given concentration and injection rate, an increased volume of contrast medium led to increases in Imax A, P and L. In addition, Tmax A, P, L and Teq were prolonged in parallel with increases in injection time The time-attenuation curve shifted upward and to the right. For a given volume and injection rate, an increased concentration of contrast medium increased the degree of aortic, portal and hepatic enhancement, though Tmax A, P and L remained the same. The time-attenuation curve shifted upward. For a given volume and concentration of contrast medium, changes in the injection rate had a prominent effect on aortic enhancement, and that of the portal vein and hepatic parenchyma also showed some increase, though the effect was less prominent. A increased in the rate of contrast injection led to shifting of the time enhancement curve to the left and upward. B. Computer Simulation: At a faster injection rate, there was minimal change in the degree of hepatic attenuation, though the duration of the optimal temporal window decreased. The area between 10 and 30 HU was greatest when contrast media was delivered at a rate of 2 3 mL/sec. Although the total area under the curve increased in proportion to the injection rate, most of this increase was above the upper threshould and thus the temporal window was narrow and the optimal area decreased. Conclusion: Increases in volume, concentration and injection rate all resulted in improved arterial enhancement. If cost was disregarded, increasing the injection volume was the most reliable way of obtaining good quality enhancement. The optimal way of delivering a given amount of contrast medium can be calculated using a computer-based mathematical model.

  • PDF

A Study on the Influence of Consumer Type on the Choice of Next-Generation Eco-Friendly Vehicle and Consumer Purchase Intention - Comparative Study on Japan and Korea - (소비자 유형이 차세대 친환경자동차선택속성과 소비자 구매의도에 미치는 영향에 관한 연구 - 한국 일본 비교연구 -)

  • Yim, Ki-Heung;Chong, Min-Young
    • Journal of Digital Convergence
    • /
    • v.15 no.11
    • /
    • pp.133-146
    • /
    • 2017
  • In recent years, the development and market participation of major makers of next-generation eco-green vehicles has been accelerating. Consumer interest has also increased. Consumer characteristics, consumption type, characteristics of next-generation eco-friendly vehicles, and government policies on next eco-green vehicles. The results of this study are as follows. In Korea, there was no significant difference by gender, age, monthly average income, and consumer type. However, there was no significant difference in purchase intention by gender, age, and monthly income, Respectively. In the case of Japan, there was no significant difference by gender, age, monthly income, and consumer type. In Korea, on the other hand, images such as brand, color, and design have positive effects on eco-friendly vehicles. In the case of Japan, image and stability have a positive effect on consumers' purchasing behavior. Therefore, it is important for Japanese consumers to consider not only the image of purchasing an eco-friendly vehicles, but also the safety of the vehicles body, appear. In the case of Korea, the socio-environmental value-seeking type has a significant relationship with the purchasing intention. In the case of socio-environmental value-seeking type, the government's support policy such as carbon dioxide tax, direct support from the national or local governments, gasoline tax, Carbon tax and fuel related tax relief showed positive effects. In the case of Japan, the price-seeking type and the socio-environmental value-seeking type were found to have a significant relationship with the purchasing intention. Both the price-seeking type and the socio-environmental value-seeking type showed that the carbon dioxide tax, Direct support, gasoline tax, gasoline tax, and carbon tax, etc. have positive effects.

Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols (전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가)

  • Nam, So-Ra;Son, Hye-Kyung;Lee, Sang-Hoon;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation dose for clinical PET/CT protocols in clinical environments using Alderson phantom and TLDs. Radiation doses were evaluated for both Philips GEMINI 16 slice PET/CT system and GE DSTe 16 slice PET/CT system. Specific organ doses with $^{137}Cs$ transmission scan, high quality CT scan and topogram in philips GEMINI PET/CT system were measured. Specific organ doses with CT scan for attenuation map, CT scan for diagnosis and topogram in GE DSTe PET/CT system were also measured. The organs were selected based on ICRP60 recommendation. The TLDs used for measurements were selected for within an accuracy of ${\pm}5%$ and calibrated in 10 MV X-ray radiation field. The effective doses for $^{137}Cs$ transmission scan, high qualify scan, and topogram in Philips GEMINI PET/CT system were $0.14{\pm}0.950,\;29.49{\pm}1.508\;and\;0.72{\pm}0.032mSv$ respectively. The effective doses for CT scan to make attenuation map, CT scan to diagnose and topogram in GE DSTe PET/CT system were $20.06{\pm}1.003,\;24.83{\pm}0.805\;and\;0.27{\pm}0.008mSv$ respectively. We evaluated the total effective dose by adding effective dose for PET Image. The total PET/CT doses for Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan+PET, Topogram+high qualify CT+PET) and GE DSTe PET/CT (Topogram +CT for attenuation map+ PET, Topogram+diagnostic CT+ PET) are $7.65{\pm}0.951,\;37.00{\pm}1.508,\;27.12{\pm}1.003\;and\;31.89{\pm}0.805mSv$ respectively. Further study may be needed to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with good image qualify.

  • PDF

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF

A Study on the Ambivalent Characteristic Displayed in Niki de Saint Phalle's Assemblages and Shooting Paintings by Looking Into Her Trauma (니키 드 생 팔의 트라우마를 통해 살펴본 아상블라주와 사격회화의 양면적 특성)

  • Yoo, Ka-Eun
    • The Journal of Art Theory & Practice
    • /
    • no.6
    • /
    • pp.77-99
    • /
    • 2008
  • The purpose of this study is to show that the reason behind the ambivalent characteristic displayed in Niki de Saint Phalle's works is in her trauma and how such characteristic can be extracted from her works. During her creative years, Saint Phalle worked on various materials from different genres such as assemblages, shooting paintings, a series on Bride and Monster, 'Nana', 'Tarot Garden'and public sculptures. One commonality found among her various works is the ambivalent characteristic that contains contrasting elements simultaneously. Saint Phalle suffered a terrible psychological damage inflicted by her parents during her childhood. Specifically, she was sexually assaulted by her father and emotionally neglected by her mother, the trauma that affected her for the rest of her life. As a result, she came to develop extreme love- hate relationships with her parents and this became the main reason for the ambivalent characteristic displayed in her works. The love-hate relationship Saint Phalle developed can be identified through various researches done on the subject of the affect of sexual assault. It is common for incest victims to develop ambivalent feelings towards the perpetrator and Saint Phalle was no exception. Dissociation disorder and a snake well explain the trauma from her father. It is a generally accepted belief in the field of psychology that dissociation disorder commonly occurs to children who experience incest. And dissociation disorder is similar to the characteristic of ambivalence in the sense that a single entity contains more than two contrasting elements at the same time. In addition, the amputated doll objects used in her assemblages coincide with the expression of body detachment of people with dissociation disorder. These facts clearly indicate that the trauma from her father is showing through in her works. A snake is a subject matter that reflects the ambivalent tendency of Saint Phalle that resulted from her trauma. She remembers her father's rape as an image of a snake which is related to a phallic symbol in mythology or art reflecting her trauma. Moreover, she displays a similar pattern of ambivalent emotion like love and hate or fear towards a snake and her father. This is also confirmed by her portrayal of a snake as a monster or reversely as a creature with fundamental vitality in her works. The lack of affection from her mother can be explained by her mother's maternal deprivation. It appears that Saint Phalle's mother possessed all the causes for maternal deprivation such as maternal separation, personality disorder and inappropriate attitude towards child rearing. Especially, a study that shows mother's negative attitude towards child breeding tends to increase dissociation experience of children is another important evidence that supports Saint Phalle's dissociation tendency. These traces of Saint Phalle's trauma are clearly revealed in her assemblages and shooting paintings. The violent objects in her assemblages such as a hammer, razor, nail represent the rage and defensiveness towards her father. The objects such as fragments of broken plates of feminine patterns, pots and mirrors that her mother used symbolize the affection towards her mother. On the other hand, the destructed objects can be interpreted as her hate and resentment towards her mother. Shooting paintings contain her extreme fury and hate. Things such as acts of shooting and the image associated with blood after shooting are blunt expressions of her bursts of emotions. I have tried to define and classify the ambivalent characteristics shown in her assemblages and shooting paintings as hate, rage, violence, calm, love and pleasure according to the frame of Thanatos and Eros. Out of the six, hate, rage, violence and clam are associated with Thanatos while love and pleasure are associated with Eros and they correspondingly form an ambivalent structure. These ambivalent characteristics can be found in her assemblages and shooting paintings. The objects in her assemblages such as a razor, saw, hammer imply hate, rage, violence and the silence felt throughout her works represent calmness. And, as mentioned, the feminine objects can be seen as symbolizing love. In shooting paintings, hate, rage, violence can be found in the use of force and in the traces of watercolor after shooting, and a sense of pleasure in her feelings of catharsis after her shooting. Moreover, a shielded calmness can be found on the plywood all covered with plaster before the shooting. This study looked into the ambivalent characteristic of Saint Phalle's works by examining her trauma to find its correlation, and a meaning of this study can be found from the fact that it refocused the origin of Saint Phalle who is generally known as a feminist artist. Additionally, a meaning of the study can be found also from the fact that it examined the ambivalent characteristics of her works through a frame of Thanatos and Eros.

  • PDF

A Convergence Study for the Academic Systematization of Cartoon-animation (만화영상학의 학문적 체계화를 위한 융합적 연구)

  • Lim, Jae-Hwan
    • Cartoon and Animation Studies
    • /
    • s.43
    • /
    • pp.285-320
    • /
    • 2016
  • Cartoons and Animation are convergent arts created with a composite application of language arts described in the form of literary texts and sounds, plastic arts visualized in the form of artistic paintings, and film arts produced in the form of moving pictures. An academic university major in cartoons and animation studies established in late 20th century however, did not satisfactorily meet the needs in academic research and development and the free expression of artistic creation was limited. In order to systematize the major in cartoons and animation studies, an convergent approach to establish and clarify following are in demand : the terms and definitions, the historical developments, the research areas and methods, the major education and related jobs and start-ups. New culture and arts industries including cartoons, animation, moving images, and games contents are not yet listed in the industries listing service jointly provided online by the portal site Naver.com and Hyung-Seol publishing company. Above all, cartoons and animation are inseparably related to each other that even if one uses the term separately and independently, the meaning may not be complete. So a new combined term "Animatoon" can be established for the major in cartoons and animation studies and also used for its degree with concentrations of cartoons, animation, moving images, games, and etc. In the Introduction, a new combined term Animatoon is defined and explained the use of this term as the name of the major and degree in cartoons and animation studies. In the body, first, the Historical Developments classified Animatoon in the ancient times, the medieval times, and the modern times and they are analyzed with the help of esthetics and arts using examples of mural frescos, animal painting, religion cartoons, caricatures, cartoons, satire cartoons, comics, animation, 2 or 3 dimensional webtoons, and K-toons. Second, the Research Areas of Animatoon reviewed the theories, genres, artworks, and artists and the Research Methods of Animatoon presented the curriculum that integrated the courses in humanities, science technologies, culture and arts, and etc. Third, the Major Education considered Animatoon education in children, young adults, students of the major and the Related Jobs and Start-Ups explored various jobs relating to personal creation of artwork and collective production of business-oriented artwork. In the Conclusion, the current challenges of Animatoon considered personalization of the artists, specialization of the contents, diversification of the types, and liberalization of the art creation. And the direction of improvement advocated Animatoon to be an academic field of study, to be an art, to be a culture, and to be an industry. The importance of cartoons and animation along with videos and games rose in the 21st century. In order for cartoons and animation to take a leading role, make efforts in studying Animatoon academically and also in developing Animatoon as good contents in the cultural industries.

The Discriminating Nature of Dopamine Transporter Image in Parkinsonism: The Competency of Dopaminergic Transporter Imaging in Differential Diagnosis of Parkinsonism: $^{123}I-FP-CIT$ SPECT Study (도파민운반체 영상의 파킨슨증 감별진단 성능: $^{123}I-FP-CIT$ SPECT 연구)

  • Kim, Bom-Sahn;Jang, Sung-June;Eo, Jae-Seon;Park, Eun-Kyung;Kim, Yu-Kyeong;Kim, Jong-Min;Lee, Won-Woo;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.272-279
    • /
    • 2007
  • Purpose: The aim of this study was to evaluate the discriminating nature of $^{123}I-FP-CIT$ SPECT in patients with parkinsonism. Methods: $^{123}I-FP-CIT$ SPECT images acquired from the 18 normal controls; NC ($60.4{\pm}10.0$ yr) and 237 patients with parkinsonism ($65.9{\pm}9.2$ yr) were analyzed. From spatialIy normalized images, regional counts of the caudate, putamen, and occipital lobe were obtained using region of interest method. Binding potential (BP) was calculated with the ratio of specific to nonspecific binding activity at equilibrium. Additionally, the BP ratio of putamen to caudate (PCR) and asymmetric Index (ASI) were measured. Results: BPs of NC $3.37{\pm}0.57,\; 3.10{\pm}0.41,\; 3.23{\pm}0.48$ for caudate, putamen, whole striatum, respectively) had no significant difference with those of essential tremor; ET ($3.31{\pm}0.64,\; 3.06{\pm}0.61,\; 3.14{\pm}0.63$) and Alzheimer's disease; AD (3.33 $\pm$0.60, 3.29$\pm$0.79, 3.31$\pm$0.70), but were higher than those of Parkinson's disease; PD (1.92$\pm$0.74, 1.39$\pm$0.68, 1.64$\pm$0.68), multiple system atrophy; MSA (2.36$\pm$1.07, 2.16$\pm$0.91, 2.26$\pm$0.96), and dementia with Lewy body; DLB (1.95$\pm$0.72, 1.64$\pm$0.65, 1.79$\pm$0.66)(p<0.005). PD had statisticalIy lower values of PER and higher values of ASI than those of NC (p<0.005). And PD had significantIy lower value of PCR, higher ASI and lower BP in the putamen and whole striatum than MSA (p<0.05). Conclusion: Dopamine transporter image of $^{123}I-FP-CIT$ SPECT was a good value in differential diagnosis of parkinsonism.

Treatment Margin Assessment using Mega-Voltage Computed Tomography of a Tomotherapy Unit in the Radiotherapy of a Liver Tumor (간종양 방사선치료 시 토모테라피 메가볼트 CT를 이용한 치료 여백 평가)

  • You, Sei-Hwan;Seong, Jin-Sil;Lee, Ik-Jae;Koom, Woong-Sub;Jeon, Byeong-Chul
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.280-288
    • /
    • 2008
  • Purpose: To identify the inter-fractional shift pattern and to assess an adequate treatment margin in the radiotherapy of a liver tumor using mega-voltage computed tomography (MVCT) of a tomotherapy unit. Materials and Methods: Twenty-six patients were treated for liver tumors by tomotherapy from April 2006 to August 2007. The MVCT images of each patient were analyzed from the $1^{st}$ to the $10^{th}$ fraction for the assessment of the daily liver shift by four groups based on Couinard's proposal. Daily setup errors were corrected by bony landmarks as a prerequisite. Subsequently, the anterior-, posterior-, right-, and left shifts of the liver edges were measured by maximum linear discrepancies between the kilo-voltage computed tomography (KVCT) image and MVCT image. All data were set in the 2-dimensional right angle coordinate system of the transverse section of each patient's body. Results: The liver boundary shift had different patterns for each group. In group II (segment 2, 3, and 4), the anterior mean shift was $2.80{\pm}1.73\;mm$ outwards, while the left mean shift was $2.23{\pm}1.37\;mm$ inwards. In group IV (segment 7 and 8), the anterior-, posterior-, right-, and left mean shifts were $0.15{\pm}3.93\;mm$ inwards, $3.15{\pm}6.58\;mm$ inwards, $0.60{\pm}3.58\;mm$ inwards, and $4.50{\pm}5.35\;mm$ inwards, respectively. The reduced volume in group II after MVCT reassessment might be a consequence of stomach toxicity. Conclusion: Inter-fractional liver shifts of each group based on Couinard's proposal were somewhat systematic despite certain variations observed in each patient. The geometrical deformation of the liver by respiratory movement can cause shrinkage in the left margins of liver. We recommend a more sophisticated approach in free-breathing mode when irradiating the left lobe of liver in order to avoid stomach toxicity.