• Title/Summary/Keyword: body acceleration

Search Result 422, Processing Time 0.031 seconds

A Safety Assessment on Light Weight Wheelchair Occupant in Frontal Crash (경량 휠체어 탑승자의 차량 전방충돌시 안전성 평가)

  • 김성민;김성재;강태건
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.15-21
    • /
    • 2003
  • In this study, for a safetv assessment of light weight wheelchair occupant in frontal crash, we tested a dynamic sled impact test. we carried out total 6 times test and impact speed was 20g/48 km/h. By using Hybrid III 50%ile male dummy, head injury criteria(HIC), neck flexion moment, neck axial tension force, neck shear force. chest acceleration, head, wheelchair and knee excursion were measured, we evaluated light weight wheelchair occupant safety by motion criteria(MC) which proposed in SAE J2249 and combined injury criteria(CIC) which is a voluntary standard(GM-IARV) of General Motors Co.. when we assumed that the maximum injury value in frontal crash was 100%, the result of motion criteria(MC) of wheelchair occupant was 52%, occupant upper body injury index(CIC) was 60.1%.

The Application Technology of Korean-style R&D in Verification for deploying the Neo-Korean Style Public Building - Focused on the positivistic case R&D Technologies in Neo-Korean Style Public building

  • Kim, Young-Hoon;Peck, Yoo-Jung;Park, Joon-Young
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: This study, by comprehensively the characteristics of new Hanok application techniques with the proposed site application technology in the course of the design changes that have been accumulated through Hanok technology development the second stage business, by analyzing the range of reflection, new Considering the direction reflects the efficiency of the new Hanok application techniques. Method: new Hanok application technology, it was been established through research and development of large 1 new Hanok technology it has been proposed through the "site-specific application techniques" and 2 builders and designers "space-time proposed technique" Analysis of the case, at the center of the design changes, the land the body of laws and regulations, the requirements of the public buildings, compared to the construction method and the like for the reduction of construction costs, new Hanok applied technology in the process of change by it There was analyzed whether acceleration on the range and step which is reflected in the design Result: The result of new Hanok applied technology was built through the demonstration build business case, process another major technology, foundation, woodwork, walls, roof, has been reflected in the ceiling construction, the inclusion of items in the proposed technique of construction , it was applied to the main steps in general, except for other construction work landscaping. Application techniques and construction proposal technology research team has presented, show the difference between the scope and method. With significance effort to improve the unreasonable traditional methods of these core processes that can be reflected in the field repeated the construction proposed technique as a result of the utility that can be applied for substantial construction.

A Study on Wearable Emergency Medical Alarm System (착용형 응급의료 경보시스템 구현에 관한 연구)

  • Kim, Dong-Wan;Beack, Seung-Hwa
    • Journal of IKEEE
    • /
    • v.10 no.1 s.18
    • /
    • pp.55-61
    • /
    • 2006
  • In modern society, development of medical technology has extended the human life span. However, it has also caused some side-effects. Mostly old people who live alone are not available the medical service quickly when they are in emergency situations. Moreover heart related diseases as well are rapidly increasing with aging. This study proposes the emergency medical alarm system. This system measures the physiological signals such as ECG(electrocardiogram), temperature, and motion data, analyzes those data automatically, and sends the urgent message to the Emergency Medical Center and to their family. There are two main parts in the system. In the first part, physiological data acquisition part, the troublesome addition and deletion of body signals on existing proposed systems have been supplemented, which led to the modulized production by means of ECG sensor module, temperature sensor module, acceleration sensor module. The other part is mobile unit, which includes signal processing and transmission functions. And bluetooth allows two parts to communicate with each other. Data that are processed in the mobile unit are stored in the PC database through the WLAN using TCP/IP protocol.

  • PDF

A Study Concerning Analysis of Arousal State of locomotive Engineering During Operating Train (열차 운행 중인 기관사의 각성상태 분석에 관한 연구)

  • Yang, Heui-Kyung;Lee, Jeong-Whan;Lee, Young-Jae;Lee, Jae-Ho;Lim, Min-Gyu;Baek, Jong-Hyen;Song, Yong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.891-898
    • /
    • 2012
  • The study for the passenger's comfortableness of vehicles and the arousal of car drivers has been done widely. On the other hand, there are few studies for the locomotive engineers. Human error means that the mistakes made by human, recently it receives attention in the field of safety engineering and human engineering. Comparing the operating condition of train with car, because of the simplification of the visual stimulus, the arousal level on the train goes down easily. The arousal level down makes judgement down, the accident risk from human error is getting bigger. In this study, we measured bio-signals(ECG, EDA, PPG, respiration and EEG) from 6 locomotive engineers to evaluate their arousal state while they operated the train. Also we recorded the 3 axes acceleration signal showing the vibration state of train. Also, the existence of tunnels were simultaneously measured. At the station section where the train speed goes down, the size of vector's sum decreases because of reduced vibration. Beta component in EEG tends to increase at the entering point of each station and tunnel. It is due to the arousal reaction and tension growth. The mean SCR(skin conductance response) was more increased in neutral section. As the button control movement (body movement) increases in the neutral section, it is appeared that SCR increase. RR interval tends to gradually increase during train operation for 1 hour 40 minutes. However, It tends to sharply decrease at the stop station because strong concentration needed to stop train on the exact point. The engineer's arousal reaction can be checked through analysing the bio-signal change during train operation. Therefore, if this analysing result is adopted to the sleepiness prevention caution system, it will be useful for the safety train operation.

Effects of Green Tea Catechin on Cytochrome $P_{450}$, Xanthine Oxidase Activities in Liver and Liver Damage in Streptozotocin induced Diabetic Rats (Streptozotocin 유발 당뇨쥐에서의 Cytochrome P_{450}, Xanthine Oxidase 활성과 간조직의 손상에 미치는 녹차 Catechin의 영향)

  • 박규영;이순재;임정교
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.5
    • /
    • pp.901-907
    • /
    • 1997
  • The purpose of this study was to investigate the effects of green tea catechin o n free radical generation system and peroxidative damage in the liver of streptozotocin(STZ)-induced diabetic rats. Spragu-Dawley male rats weighing 150$\pm$10gm were randomly assigned to one normal and three STZ-induced diabetic groups; diabetic groups were classified to catechin free diet(DM-oC group), 0.5% catechin diet(DM-0.5C group) and 1% catechin diet(DM-1C group) according to the levels of dietary catechin supplementation. Diabetes was experimentally induced by intravenous injection of 55mg/kg of body wt of STZ in citrate buffer(pH 4.3) after feeding of three experimental diet for 4 weeks. Animals were sacrificed at the 6th day of diabetic states. Activities of serum glutamic oxaloacetic transaminase(GPT) in DM-oC groups were higher than those of the normal group, and those in catechin supplementation group were similar to those of the normal group. Liver lipid peroxide values increased by 153%, 49%, and 27% in Dm-oC, DM-0.5C and DM-0C and Dm-1C but was not significantly different in catechin supplementation groups compared with the normal group, and liver cytochrome $P_{450}$ contents was similar to result of XOD activity. In electron microscopic examination of liver, lysosome was relatively scattered in Dm-oC and Dm-0.5C group and preserved normal shapes in DM-1C group. The present results indicate that STZ-induced diabetic rats are more sensitive to oxidative stress, leading to the acceleration of lipid peroxidation process, but this was reduced by anti-oxidative effect of high level of dietary catechin. It is concluded that dietary catechin serves as powerful antioxidant against lipid peroxidation in diabetic rats.

  • PDF

Real-time Activity and Posture Recognition with Combined Acceleration Sensor Data from Smartphone and Wearable Device (스마트폰과 웨어러블 가속도 센서를 혼합 처리한 실시간 행위 및 자세인지 기법)

  • Lee, Hosung;Lee, Sungyoung
    • Journal of KIISE:Software and Applications
    • /
    • v.41 no.8
    • /
    • pp.586-597
    • /
    • 2014
  • The next generation mobile computing technology is recently attracting attention that smartphone and wearable device imbedded with various sensors are being deployed in the world. Existing activity and posture recognition research can be divided into two different ways considering feature of one's movement. While activity recognition focuses on catching distinct pattern according to continuous movement, posture recognition focuses on sudden change of posture and body orientation. There is a lack of research constructing a system mixing two separate patterns which could be applied in real world. In this paper, we propose a method to use both smartphone and wearable device to recognize activity and posture in the same time. To use smartphone and wearable sensor data together, we designed a pre-processing method and constructed recognition model mixing signal vector magnitude and orientation pattern features of vertical and horizontal. We considered cycling, fast/slow walking and running activities, and postures such as standing, sitting, and laying down. We confirmed the performance and validity by experiment, and proved the feasibility in real world.

Head Thrust Test (두부충동 검사)

  • Choi, Kwang-Dong;Oh, Sun-Young;Kim, Ji Soo
    • Annals of Clinical Neurophysiology
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • The head thrust maneuver is a simple bedside test of the higher frequency vestibulo-ocular reflex, which is based on Ewald's second law. It is performed by grasping the patient's head and applying a brief, small-amplitude, high-acceleration head turn, first to one side and then to the other. The patient fixates on the examiner's nose and the examiner watches for corrective rapid eye movements (saccades), which are a sign of decreased vestibular response. The "catch-up" saccades after a head thrust in one direction indicate a peripheral vestibular lesion on that side (in the labyrinth or the $8^{th}$ nerve including the root's entry zone in the brain stem). An individual pair of vertical semicircular canals can also be stimulated by turning the head to the right or left by $45^{\circ}$ and then by rotating the head in the pitch plane relative to the body. Recent studies have suggested that assessment of individual semicircular canal function by head thrust test may provide useful information for anatomical and functional details of a variety of peripheral vestibulopathies and for predicting the prognosis of vestibular neuritis. In central vestibulopathy, the head thrust test may also be valuable sign to determine dysfunction of the central pathways from individual semicircular canals and its role for the development of diverse central nystagmus.

  • PDF

Research Trends for Performance, Safety, and Comfort Evaluation of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Ryu, Myong-Jin;Chung, Sun-Ok;Kim, Yong-Joo;Choi, Chang-Hyun;Hong, Soon-Jung;Sung, Je-Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.1
    • /
    • pp.21-33
    • /
    • 2014
  • Background: Significant technological development and changes happened in the tractor industries. Contrariwise, the test procedures of the major standard development organizations (SDO's) remained unchanged or with a little modification over the years, demanding new tractor test standards or improvement of existing ones for tractor performance, safety, and comfort. Purpose: This study focuses on reviewing the research trends regarding performance, safety and comfort evaluation of agricultural tractors. Based on this review, few recommendations were proposed to revise or improve the current test standards. Review: Tractor power take-off power test using the DC electric dynamometer reduced human error in the testing process and increased the accuracy of the test results. GPS signals were used to determine acceleration and converted into torque. High capacity double extended octagonal ring dynamometer has been designed to measure drawbar forces. Numerical optimization methodology has been used to design three-point hitch. Numerous technologies, driving strategies, and transmission characteristics are being considered for reducing emissions of gaseous and particulate pollutants. Engine emission control technology standards need to be revised to meet the exhaust regulations for agricultural tractors. Finite Element Analysis (FEA) program has been used to design Roll-Over Protective Structures (ROPS). Program and methodology has been presented for testing tractor brake systems. Whole-body vibration emission levels have been found to be very dependent upon the nature of field operation performed, and the test track techniques required development/adaptation to improve their suitability during standardized assessment. Emphasizes should be given to improve visibility and thermal environment inside the cab for tractor operator. Tractors need to be evaluated under electromagnetic compatibility test conditions due to large growing of electronic devices. Research trends reviewed in this paper can be considered for possible revision or improvement of tractor performance, safety, and comfort test standards.

Study of Ride Comfort on Train through Physiological Parameter (생체 신호를 이용한 열차 승차감 평가 시스템 연구)

  • Song, Yong-Soo;Oh, Suk-Moon;Lee, Jae-Ho;Kim, Yong-Kyu
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.237-250
    • /
    • 2011
  • The train transportation has a lot of advantages-energy efficiency is high, it is eco-friendly, safety is better than normal roads and it is possible for people to arrive on time. In these days, the valuation of ride comfort, which is only limited to road transportation, is newly recognized in order to having competitiveness from other transportation. Especially, in the development of the Korean high-speed railroad business, the ride comfort enhancement of train is very important problem to be solved. Currently, there are international standards of ride comfort such as UIC13, ISO2631. In Korea case, although it has own standard like KS R9216, it mainly depends on the physical parameter such as vibration and noise. So recently, in the valuation of ride comfort, the movements of living parameter technique introduction are increasing on the base of Japan and many developed countries of Europe techniques. Presently, the method of train ride comfort is mainly based of vibration, that is, mechanical parameter adding selection of variable acceleration and noise. This paper would like to show biological parameter; heart rate and blood pressure variation. This method is more direct, based on human body response, than mechanical parameter method. In this experiment, the variability of heart rate and blood pressure of passengers according to tilting angle change of Train, the Korean tilting train, we are supposed to know that the extent of tilting on the simulation has influence on variability of heart rate and blood pressure, which are living parameter of heart's blood.

Ride Quality Investigation of Passenger Cars on Different Road Conditions

  • Park, Se Jin;Subramaniyam, Murali
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.389-396
    • /
    • 2013
  • Objective: The ride qualities of the six passenger cars were evaluated in 4 subjects on the highway and uneven road. The relation between vibration with driving velocity and driving posture were also investigated separately. Background: Ride comfort plays an important role in the vehicle design. Vibration is the one of the principal components associated with ride comfort. Method: The acceleration of the foot, hip and back were measured using B&K accelerometers in this study. The velocity of the passenger cars was maintained at a constant speed of 80km/h on the highway and 40km/h on the uneven road. For evaluating the effects of driving velocity and driving posture on vehicle's vibration level, separate experiments were performed on the highway with 5 different vehicle speeds and 5 different backrest angles, respectively. Results: The overall ride value of the luxury car showed the best result while the smaller car showed the worst value on the highway. On the uneven road the overall ride value level was increased 75~98%. All the vehicles had the SEAT value less than 1. Faster the velocity lowers the SEAT value. The ride quality in terms of vibration gets worst when the backrest angle increased. Conclusion: The smaller car had a first mode at the higher frequency and showed higher vibration level. SEAT value was mostly affected by the seat property not by vehicle. We ranked the luxury car seat had a best vibration reduction quality than others based on SEAT values. When the driving velocity increased, the overall ride values were increased proportionally and the SEAT values were somewhat decreased. Application: Evaluation of whole-body vibration in the passenger car.