• Title/Summary/Keyword: blue-green laser

Search Result 38, Processing Time 0.027 seconds

Study on the Luminescence of Si Nanocrystallites on Si Substrate Fabricated by Changing the Wavelength of Pulsed laser deposition (펄스레이저 증착법의 레이저 파장변환에 의한 실리콘 나노결정의 발광특성 연구)

  • Kim, Jong-Hoon;Bae, Sang-Hyuck;Lee, Sang-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.411-412
    • /
    • 2000
  • Si nanocrstallites on p-tyre (100) Si substrate have been fabricated by pulsed laser deposition technique using a Nd:YAG laser with the wavelength of 355, 532 and 1064 nm. The base vacuum in the chamber was down to $10^{-5}$ Torr and the pressure of the gas during deposition was varied from 1 to 3 Torr. After deposition, Si nanocrystallites have been annealed at $N_2$ gas. Nitrogen have been used as ambient gases. Strong blue and green luminescence from Si nanocrystallites has been observed in room temperature by photoluminescence and its peak energies shift to green when the wavelength is increased from 355-1064 nm

  • PDF

Enhancement of blue-green dye energy laser using an energy converter dye (에너지 전환을 이용한 청록색소레이저의 출력 증가)

  • 최영수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.66-68
    • /
    • 1991
  • 색소레이저의 효율과 출력 증가를 위한 연구에서 보다 강력한 펌핑 광원의 개발에 주로 많은 관심을 기울이고 있다. 그러나 본 연구에서는 펌핑광의 스펙트럼 전환을 이용하여 청록색레이저의 효율과 출력에너지를 증가 시켰다. 레이저 색소 Coumarin 503을 전환색소 BBQ와 혼합하므로 160% 이상의 청록색레이저의 출력에너지 증가와 61%의 구배 효율 증가를 얻었다.

  • PDF

Crystal Growth of Nd;YCOB and Fabrication of RGB Laser Device (Nd:YCOB 단결정 성장과 RGB 레이저 소자 제조)

  • 김충렬;석상일;장원권;김도진;유영문
    • Korean Journal of Crystallography
    • /
    • v.12 no.1
    • /
    • pp.5-9
    • /
    • 2001
  • Nd/sub 0.05/Y/sub 0.95/Ca₄O(BO₃)₃(Nd:YCOB) single crystals were grown by the Czochralski method using a iridium crucible under N₂ atmosphere. Optimum growth parameters to get high quality of single crystals were 1.5∼2 mm/hr of growth rate and 10∼20 rpm of rotation rate. The grown crystals were transparent with light purple color and well-developed in cleavage planes. The crystal structure of Nd;YCOB were identified to monoclinic by XRD method. Crystal defects acting as light scattering centers, such as micro-pores, secondary phases, inclusions and cracks were not observed under the He-Ne laser illuminations. Three red, green, blue laser devices for the RGB laser oscillations were designed and then fabricated from the grown Nd:YCOB crystals according to the phase-matching angles of negative type-I which were φ=16.40°, 33.95° and θ=22.59° with the flatness of λ/6 at least, respectively.

  • PDF

A Study of f-${\theta}$ Lens Design for Axisymmetric Spherical Surface for RGB Laser Display and its applications (RGB 레이저 가시화를 위한 축대칭 구면 f-${\theta}$ 렌즈 설계 및 프로젝션응용)

  • Lee, Y.M.;Choi, H.W.
    • Laser Solutions
    • /
    • v.14 no.2
    • /
    • pp.24-29
    • /
    • 2011
  • The design of a telecentric f-${\theta}$ lens with a field of view (FOV) $30^{\circ}$ and an effective focal length of 1000mm is presented. The optical stop is placed at the front plane and the design is based on a geometric ray tracing technique, and the designed system consists of a series of convex and concave lenses. The designed f-${\theta}$ lens showed a considerable reduction in weight with a simplified structure and resulted in a good performance in the designated FOV. Detail analysis of rays is also presented. 653nm (red laser), 586nm (green laser), and 468nm (blue laser) were simulated as a light source and image illuminating source. The developed optical design requires 7 pieces of lenses made of SF1, N-FK56, N-LAK33, and BK7 glass materials. With optimal parametric design, the effective focal length was calculated to be 974.839mm which is very close to the initial design target. For the manufacturing purpose, the dimensions of lens curvature and thickness were truncated with error ranging 0.1% to 3.2%. As a result, the overall error was calculated to be 3.2% which can be still tolerable for display, laser material, and machining processing.

  • PDF

Quantitative analysis for evaluating the laser therapy effects of the skin pigmented lesions (피부 색소 질환의 치료 효과 판정을 위한 정량적 분석)

  • Kim, S.C.;Rah, D.K.;Kim, D.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.309-310
    • /
    • 1998
  • Visual observation and subjective assessments lack the objective evaluation of laser therapy effects of the epidermal pigmented lesions. In this study, we proposed the two methods; One is CIE(Commission International d'Eclairage) $L^*,\;a^*,\;b^*$ coordinate system($L^*$ : brightness, $a^*$ : red(+) $\sim$green(-) content, $b^*$ : yellow(+) $\sim$blue(-) content), and the other is the relative color difference measurement. And we applied these two methods for quantitative evaluation of the laser therapy effects.

  • PDF

All-fiber RGB Laser Light Source of Head-up Display System for Automobile Application

  • Lee, Jonggwan;Kim, Kyungwon;Son, Seong-Jin;Kim, Bok Hyeon;Yu, Nan Ei
    • Current Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.221-228
    • /
    • 2020
  • We developed an all-fiber RGB laser light source module for application in an automobile head-up display. It is based on laser diodes and an optical fiber combiner that substantially enhances the flexibility of configuration and stability against harsh working conditions for automobiles. We coupled 13 laser diodes with optical fibers and merged them into a single output with a beam combiner device. Red (R), green (G), and blue (B) laser sources were employed to produce primary colors that were mixed into a white light output. An optical output power of approximately 1.5 W was achieved, and the color balance of the output lights was assessed based on the CIE 1931 color space. The optical output power was shown to be stable for over 160 h within an optical fluctuation of less than 0.27%.

Linked Color Imaging and Blue Laser Imaging for Upper Gastrointestinal Screening

  • Osawa, Hiroyuki;Miura, Yoshimasa;Takezawa, Takahito;Ino, Yuji;Khurelbaatar, Tsevelnorov;Sagara, Yuichi;Lefor, Alan Kawarai;Yamamoto, Hironori
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.513-526
    • /
    • 2018
  • White light imaging (WLI) may not reveal early upper gastrointestinal cancers. Linked color imaging (LCI) produces bright images in the distant view and is performed for the same screening indications as WLI. LCI and blue laser imaging (BLI) provide excellent visibility of gastric cancers in high color contrast with respect to the surrounding tissue. The characteristic purple and green color of metaplasias on LCI and BLI, respectively, serve to increase the contrast while visualizing gastric cancers regardless of a history of Helicobacter pylori eradication. LCI facilitates color-based recognition of early gastric cancers of all morphological types, including flat lesions or those in an H. pylori-negative normal background mucosa as well as the diagnosis of inflamed mucosae including erosions. LCI reveals changes in mucosal color before the appearance of morphological changes in various gastric lesions. BLI is superior to LCI in the detection of early esophageal cancers and abnormal findings of microstructure and microvasculature in close-up views of upper gastrointestinal cancers. Excellent images can also be obtained with transnasal endoscopy. Using a combination of these modalities allows one to obtain images useful for establishing a diagnosis. It is important to observe esophageal cancers (brown) using BLI and gastric cancers (orange) surrounded by intestinal metaplasia (purple) and duodenal cancers (orange) by LCI.

Advanced Color Filter for TFT-LCD

  • Kwon, Jang-Hyuk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.159-160
    • /
    • 2000
  • A new manufacturing method using laser transfer technology was developed for a color filter of TFT-LCD. This method can make red, green and blue color layer at the same time without several baking processes. Simple process, no residue, good edge profile, and so on are merits of this process. The same performances (such as color characteristics, reliability, hardness and so on) of current color filter were achieved with this process.

  • PDF

Properties of Y3Al5O12:Ce3+,Pr3+ Single Crystal for White Laser Lightings (백색 레이저 조명용 Y3Al5O12:Ce3+,Pr3+ 단결정 특성)

  • Kang, Taewook;Lim, Seokgyu;Kim, Jongsu;Lee, Bong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.4
    • /
    • pp.37-41
    • /
    • 2018
  • $Y_3A_{l5}O_{12}:Ce^{3+},Pr^{3+}$ single crystal phosphor was prepared by floating zone method. single crystal was confirmed to have a Ia-3d (230) space group of cubic structure and showed regular morphology. The optical properties, single crystal exhibited a emission band from green, yellow wide wavelength and 610nm, 640nm red wavelength vicinity. The luminance maintenance rate was decreased by phonon with increasing temperature, but high luminance is maintained more than powder phosphor. In addition, $Y_3A_{l5}O_{12}:Ce^{3+},Pr^{3+}$ single crystal phosphor was applied to a high power blue laser diode, we implemented high power white laser lightings. and it was confirmed that thermal properties over time, due to the effective heat transfer of complete crystal structure. We confirmed that excellent radiant heat properties than powder phosphor was applied to a high power white laser diode.

Appropriate Color Enhancement Settings for Blue Laser Imaging Facilitates the Diagnosis of Early Gastric Cancer with High Color Contrast

  • Hiraoka, Yuji;Miura, Yoshimasa;Osawa, Hiroyuki;Nomoto, Yoshie;Takahashi, Haruo;Tsunoda, Masato;Nagayama, Manabu;Ueno, Takashi;Lefor, Alan Kawarai;Yamamoto, Hironori
    • Journal of Gastric Cancer
    • /
    • v.21 no.2
    • /
    • pp.142-154
    • /
    • 2021
  • Purpose: Screening image-enhanced endoscopy for gastrointestinal malignant lesions has progressed. However, the influence of the color enhancement settings for the laser endoscopic system on the visibility of lesions with higher color contrast than their surrounding mucosa has not been established. Materials and Methods: Forty early gastric cancers were retrospectively evaluated using color enhancement settings C1 and C2 for laser endoscopic systems with blue laser imaging (BLI), BLI-bright, and linked color imaging (LCI). The visibilities of the malignant lesions in the stomach with the C1 and C2 color enhancements were scored by expert and non-expert endoscopists and compared, and the color differences between the malignant lesions and the surrounding mucosa were assessed. Results: Early gastric cancers mainly appeared orange-red on LCI and brown on BLI-bright or BLI. The surrounding mucosae were purple on LCI regardless of the color enhancement but brown or pale green with C1 enhancement and dark green with C2 enhancement on BLI-bright or BLI. The mean visibility scores for BLI-bright, BLI, and LCI with C2 enhancement were significantly higher than those with C1 enhancement. The superiority of the C2 enhancement was not demonstrated in the assessments by non-experts, but it was significant for experts using all modes. The C2 color enhancement produced a significantly greater color difference between the malignant lesions and the surrounding mucosa, especially with the use of BLI-bright (P=0.033) and BLI (P<0.001). C2 enhancement tended to be superior regardless of the morphological type, Helicobacter pylori status, or the extension of intestinal metaplasia around the cancer. Conclusions: Appropriate color enhancement settings improve the visibility of malignant lesions in the stomach and color contrast between the malignant lesions and the surrounding mucosa.