• Title/Summary/Keyword: blood velocity

Search Result 393, Processing Time 0.035 seconds

Angiotensinogen gene M235T polymorphism as a predictor of cardiovascular risk in hypertensive adolescents (고혈압 청소년의 심혈관계 위험요소로서 Angiotensinogen M235T 유전자 다형)

  • Gil, Joo Hyun;Lee, Jung Ah;Park, Eun Young;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.1
    • /
    • pp.36-43
    • /
    • 2009
  • urpose : The renin-angiotensin system (RAS) has been demonstrated to play a major role in regulating blood pressure. Therefore, components of the RAS are likely candidate genes that may predispose an individual to essential hypertension and cardiovascular complications. Among them, the M235T polymorphism of the angiotensinogen gene has been speculated to be associated with elevated circulating angiotensinogen concentrations and essential hypertension. This study aimed to analyze the angiotensinogen M235T polymorphism in hypertensive adolescents and investigate its relationship with cardiovascular risks. Methods : Forty Korean hypertensive adolescents (aged 16-17, systolic $BP{\geq}140 mmHg$ and/or diastolic $BP{\geq}90 mmHg$) and fifty seven normal adolescents were included. Obesity index (OI), body mass index (BMI) were calculated. BP was measured by oscillometric methods in resting state. Polymerase chain reaction (PCR) technique was performed on DNA from the hypertensives subjects to analyze the M235T polymorphism. Serum homocysteine, insulin, renin, aldosterone and angiotensin converting enzyme (ACE) were tested according to each genotype. The carotid intima-media thickness (IMT) and carotid artery diameter, Pulse wave velocity (PWV) and ankle-brachial index (ABI) were measured according to each genotype. Results : Genotype frequencies of T/T, M/T and M/M were 62.5%, 35.0%, 2.5%, respectively in hypertensive adolescents. The results were not significantly different compared to control group. Serum insulin, renin levels, BMI and OI were significantly higher in thoses with the M/M genotype as compared to those with the T/T of M/T genotype. Conclusion : This study showed that the M235T polymorphism was not associated with essential hypertension or any cardiovascular risks. Further clinical research is required to ascertain the relationship between this polymorphism and cardiovascular complications in Korean hypertensive adolescents.

Diastolic Function in Patients with Hypertrophic Cardiomyopathy: Evaluation Using the Phase-contrast MRI Measurement of Mitral Valve and Pulmonary Vein Flow Velocities (비대성심근증 환자의 이완기능평가: 승모판과 폐정맥 유속을 측정한 위상차 MRI의 이용)

  • Kim, Eun Young;Choe, Yeon Hyeon;Kim, Sung Mok;Lee, Sang-Chol;Chang, Sung-A;Oh, Jae K.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.314-322
    • /
    • 2014
  • Purpose: Diastolic dysfunction is a common problem in patients with hypertrophic cardiomyopathy (HCM). The purpose of this study was to assess the role of MRI in the assessment of diastolic function using mitral valve and pulmonary vein flow velocities in HCM patients. Methods and Results: Phase-contrast MRI (mitral valve and pulmonary vein) and transthoracic echocardiography was successfully performed for 59 HCM patients (44 men and 15 women; mean age, 51 years). Forty-nine patients had a diastolic dysfunction; grade 1 (n = 20), grade 2 (n = 27), and grade 3 (n = 2) using echocardiography, and ten patients had normal diastolic function. The transmitral inflow parameters (E, A, and E/A ratios) obtained by MRI showed positive correlation with the same parameters measured by echocardiography (Pearson's r values were 0.47, 0.60, and 0.75 for E, A, E/A, respectively, all P < 0.001). With the flow information of the pulmonary vein from cardiac MRI, pseudo-normalized pattern (n = 8) could be distinguished from true normal filling pattern (n = 17), and the diastolic function grades by cardiac MRI showed moderate agreement with those of echocardiography (kappa value = 0.45, P < 0.001). Conclusions: Assessment of left ventricle diastolic function is feasible using phase-contrast MRI in HCM patients. Analysis of pulmonary vein flow velocity on MRI is useful for differentiating pseudo-normal from normal diastolic function in HCM patients.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Studies on the Morphological Characteristics and Life History of the Chili Fish, Cultriculus eigenmanni (Jordan et Metz) (1) On the Egg Development and the Fry in the Larval Stage (치리(Cultriculus eigenmanni)의 형태 및 생활사에 관한 연구 I. 난발생과 부화자어에 대하여)

  • KIM Eul-Bae;KIM Young-Gill
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.2
    • /
    • pp.151-156
    • /
    • 1984
  • The Chili fish, one of the most common species of the freshwater fishes, is distributed in the river basins of the western coast of Korea. However, any studies on this fish, especially its development or life history, have not been made so far. The authors, therefore, carried out an experiment to reveal some characteristics of egg develoment and fry in this fish. For accomplshing this study, we caught some adult Chili fish by means of a casting net at raceway in the vicinity of Kunsan in June and July, 1983; then, we injected 0. 1 cc Gonadotrophic hormone 1,000 unit solution (Puberogen) in order to induce the spawning on the abdominal cavity of male and female respectively, Approximately 12 hours after injection, the artificially fertilized eggs by using of the dry method and the naturally fertilized eggs were observed simultaneously in the aquarium ($30{\times}50{\times}70cm$). The fertilized eggs, in spherical shape, were sperative, demersel, adhesive nature and $1.38{\sim}1.59\;mm$ in diameter. The light yellow yolk was opaque and $1.17{\sim}l.27\;mm$ in diameter. The hatching of eggs took place at 29.5 hours after fertilization under the condition of $23.5{\sim}25.0^{\circ}C$ water temperature. Basically there were not found so many different aspects in comparison with the common species of Cyprinidae in the development process of eggs : however, there were a few noticable characteristics, that is, pigment cells, eye balls and blood circulation are invisible, or the velocity of egg development is rapid, seemed similar to the Loach's egg. Newly hatched larvae with the yolk sac (2.39 mm in size) were $3.87{\sim}3.99\;mm$ in total length and their myotome number was expressed as 28+15=43. About 20 hours after hatching, a caudal and a pectoral fin as well as an anus began to orgin. In addition, a few malanophore showed on the upper regin of the yolk sac of the larvae whose size was 4.73 mm in total length. The larvae developed about 5.02 mm in total length, and the median fin fold in the abdomen extended forward to two thirds or beyond of the yolk sac at 50 hours after hatching. Simultaneously, the eye balls and mouth also appeared. After 3 days, the yolk sac nearly disappeared, and the larvae (5.4 mm in total length) with perfect eye balls began to swim for themselves for the first time. Also, the specialization between the gill arches and the ailmentary canal, the development of each fins except dorsal fin as well as the blood circulation obviously distinguished in this stage. The larvae whose total length was 5.68 mm was very brisk: also, the development of the dorsal fin rudiment, nearly perfect formation of each organs and the function of the upper and lower jaws were noticeably observed 5 days after hatching.

  • PDF

An Association of Changed Levels of Inflammatory Markers with Hematological Factors during One-time Aerobic Exercise in Twenty-aged Young Men (20대 젊은이들에 있어 1회성 유산소운동 시 염증 표지자와 혈액변인들 간의 상관관계)

  • Hyun, Kyung-Yae
    • Journal of Life Science
    • /
    • v.19 no.11
    • /
    • pp.1658-1665
    • /
    • 2009
  • This study was carried out on thirty men to define the association of inflammatory markers with physiological factors on one-time aerobic exercise (for 15 min. Post-exercise interleukin-6 (IL-6), mean corpuscular hemoglobin concentration (MCHC), heart rate (HR), systolic blood pressure (SBP), and pulsatility and resistance index of middle cerebral artery (PI and RI, respectively) levels were elevated compared to those measured pre-exercise. Total leukocyte and platelet counts, high-sensitivity C-reactive protein (hs-CRP), free radical (FR), and low density lipoprotein cholesterol (LDL) levels tended to decrease after exercise. Pre-exercise IL-6 levels were positively correlated with pre-exercise SBP levels, while post-exercise IL-6 level was positively correlated with post-exercise PI and RI levels. Post-exercise, hs-CRP levels were negatively related to SBP and HR. Pre-exercise, FR levels were positively associated to SBP, DBP, and HR. Post-exercise FR levels were negatively related to the post-exercise blood flow velocity in middle cerebral artery. Pre-exercise erythrocyte indices (RBC, MCV, MCH, and MCHC levels) were in inverse proportion to pre-exercise IL-6 levels. Post-exercise FR levels were inversely related to post-exercise total leukocyte, lymphocyte, monocyte, and MCH levels. Pre-exercise $Mg^{++}$ levels were in inverse proportion to pre-exercise IL-6, hs-CRP, or FR levels. These findings suggest that one-time aerobic exercise offers a significant relationship between inflammatory markers and some biochemical markers or electrolytes. Further studies need to be carried out for investigation of differences between genders or age groups following one-time or regular aerobic exercise.

The Research to Correct Overestimation in TOF-MRA for Severity of Cerebrovascular Stenosis (3D-SPACE T2 기법에 의한 TOF-MRA검사 시 발생하는 혈관 내 협착 정도의 측정 오류 개선에 관한 연구)

  • Han, Yong Su;Kim, Ho Chul;Lee, Dong Young;Lee, Su Cheol;Ha, Seung Han;Kim, Min Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.180-188
    • /
    • 2014
  • It is very important accurate diagnosis and quick treatment in cerebrovascular disease, i.e. stenosis or occlusion that could be caused by risk factors such as poor dietary habits, insufficient exercise, and obesity. Time-of-flight magnetic resonance angiography (TOF-MRA), it is well known as diagnostic method without using contrast agent for cerebrovascular disease, is the most representative and reliable technique. Nevertheless, it still has measurement errors (also known as overestimation) for length of stenosis and area of occlusion in celebral infarction that is built by accumulation and rupture of plaques generated by hemodynamic turbulence. The purpose of this study is to show clinical trial feasibility for 3D-SPACE T2, which is improved by using signal attenuation effects of fluid velocity, in diagnosis of cerebrovascular disease. To model angiostenosis, strictures of different proportions (40%, 50%, 60%, and 70%) and virtual blood stream (normal saline) of different velocities (0.19 ml/sec, 1.5 ml/sec, 2.1 ml/sec, and 2.6 ml/sec) by using dialysis were made. Cross-examinations were performed for 3D-SPACE T2 and TOF-MRA (16 times each). The accuracy of measurement for length of stenosis was compared in all experimental conditions. 3D-SPACE 2T has superiority in terms of accuracy for measurements of the length of stenosis, compared with TOF-MRA. Also, it is robust in fast blood stream and large stenosis than TOF-MRA. 3D-SPACE 2T will be promising technique to increase diagnosis accuracy in narrow complex lesions as like two cerebral small vessels with stenosis, created by hemodynamic turbulence.

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

The Effects of Hypercapnia and High Flow on Cerebral Metabolism During Cardiopulmonary Bypass (심폐바이패스 시 고탄산분압과 고관류법이 뇌대사에 미치는 영향)

  • 강도균;최석철;윤영철;최국렬;정신현;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.472-482
    • /
    • 2003
  • Recent studies have demonstrated that cerebral desaturation during rewarming period of CPB was associated with postoperative neurologic dysfunction. The prevention of cerebral desaturation during CPB may reduce the incidences of neurologic and neuropsychological complications. The present study was prospectively undertaken to compare the clinical effects between two strategies (hypercapnic CPB and high flow CPB) to prevent cerebral desaturation for establishing a proper CPB technique. Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized into either hypercapnic (Pa$CO_2$ 45~50mmHg, n=18) or high flow group (flow rate 2.75 L/ $m^2$/min and Pa$CO_2$ 35~40mmHg, n=18) during rewarming period of CPB. In each patient, middle cerebral artery blood flow velocity ( $V_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v) $O_2$), modified cerebral metabolic rate for oxygen (MCMR $O_2$), cerebral oxygen transport rate ( $T_{E}$ $O_2$), incidence of cerebral desaturation (internal jugular bulb blood oxygen saturation $\leq$ 50%), increased rate of S-100 $\beta$ concentration, and arterial and internal jugular bulb blood gas were measured during the five phases of the operation; Pre-CPB, CPB-10 min (steady-state CPB, nasopharyngeal temperature 29~3$0^{\circ}C$), Rewarm-1 (rewarming phase, nasopharyngeal temperature 33$^{\circ}C$), Rewarm-2 (nasopharyngeal temperature 37$^{\circ}C$), and CPB-off. Incidence of postoperative delirium and duration were assessed in all patients. All variables were compared between the two groups. Result: $V_{MCA}$ (157.88$\pm$10.87 vs 120.00$\pm$6.18%, p=0.006), internal jugular bulb $O_2$ saturation (68.01$\pm$2.75 vs 61.28$\pm$2.87%, p=0.03) and $O_2$ tension (41.01$\pm$2.25 vs 32.02$\pm$ 1,67 mmHg, p=0.03), and $T_{E}$ $O_2$(110.84$\pm$7.41 vs 81.15$\pm$8.11%, p=0.003) at rewarming periods were higher in the hypercapnic group than in the high flow group. C(a-v) $O_2$ (4.0$\pm$0.30 vs 4.84$\pm$0.38 mg/dL, p=0.04), COE (0.36$\pm$0.03 vs 0.42$\pm$0.03, p=0.04), increased rate of S- 100$\beta$ (391.67$\pm$23.40 vs 940.0$\pm$17.02%, p=0.003), and incidence of cerebral desaturation (2 vs 4 patients, p=0.04) at rewarming periods, and duration of postoperative delirium (18 vs 34 hr, p=0.02) were low in the hypercapnic group compared to the high flow group. Conclusion: These results indicate that hypercapnic CPB may provide relatively diminished cerebral injury and beneficial effects for cerebral metabolism relatively compared to high flow CPB.low CPB.

Effects of Early Parenteral Nutrition for Extremely Low Birth Weight Infants (초극소 저출생 체중아(${\leq}$1,000 g)에서 조기에 시작하는 정맥 영양공급의 효과)

  • Ahn, So-Yoon;Shin, Ji-Hun;Shin, Jung-Hee;Sung, Se-In;Jung, Ji-Mi;Kim, Jin-Kyu;Chang, Yun-Sil;Jang, Yun-Sil;Park, Won-Soon
    • Neonatal Medicine
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2011
  • Purpose: The object of this study was to evaluate the efficacy of early total parenteral nutrition with early amino acid in extremely low birth weight infant (ELBWI). Methods: We retrospectively analyzed the medical records of all ELBWIs who were born and admitted to Samsung Medical Center from January 2003 to December 2003 and January 2009 to December 2009 and alive at the time of discharge. Data for nutritional status and morbidities were compared between period 1 (2003, n=22), in which parenteral nutritional support was started gradually over several days and period 2 (2009, n=38), in which parenteral nutrition with amino acid was started as soon as possible after birth. Results: Compared to period 1, birth weight and Apgar score were lower in period 2. The intake amount of glucose, amino acid and total calorie was higher and the level of blood urea nitrogen was increased more from 7th day to 14th day after birth in period 2 when compared than period 1. The weight gain velocity was faster at 7th and 14th postnatal day in period 2. There were no differences in the incidence of necrotizing enterocolitis, moderate to severe bronchopulmonary dysplasia, and severe intraventricular hemorrhage (${\geq}$ Gr III) between two periods but, the incidence of periventricular leukomalacia(PVL) was significantly lower in period 2. Conclusion: Early initiation of total parenteral nutrition with early amino acid in ELBWIs was beneficial at weight gain with lowering catabolism and increasing anabolism. And it could be related with reducing the incidence of PVL.

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF