• Title/Summary/Keyword: blood flow velocity

Search Result 288, Processing Time 0.032 seconds

Change of Cerebrovascular Reactivity by Prandial State in Women with Migraine without Aura: Transcranial Doppler Ultrasonography (TCD) with Breath-Holding Method (두개경유도플러초음파를 이용한 성인 여성 무조짐편두통 환자의 식사 상태에 따른 뇌혈관반응성 변화)

  • Park, Jeong-Ho;Park, Sun-Ah;Lee, Tae-Kyeong;Sung, Ki-Bum
    • Annals of Clinical Neurophysiology
    • /
    • v.14 no.1
    • /
    • pp.20-24
    • /
    • 2012
  • Background: Migraine patients can be sensitive to external or internal stimuli, such as light, noise, or hormonal changes. Using transcranial Doppler ultrasonography (TCD) with breath-holding method, we evaluated the changes of cerebrovascular reactivity (CVR) to hypercapnia in women with migraine without aura between fasting and postprandial period. Methods: Twelve women with migraine without aura and the same number of age and sex-matched healthy controls with no significant history of headache participated in this study. Using TCD examinations, we studied mean flow velocity in middle cerebral artery with better temporal window. Each subject was examined consecutively before and after a standard meal, together with serum glucose level and blood pressure. CVR was evaluated with breath-holding index (BHI). Results: Postprandial-BHI (mean+SD) was significantly higher than fasting-BHI (mean+SD) in patients group but not in controls (in patient group; postprandial-BHI=1.38, fasting-BHI=1.08, in control group; postprandial-BHI=1.25, fasting-BHI=1.18, P=0.021 and 0.239, respectively). After meal, serum glucose level was significantly enhanced but blood pressure was not in both groups. Serum glucose level of patients showed a tendency of mild positive correlation with BHIs (${\gamma}$=0.448, P=0.032). Conclusions: Although exact mechanisms are unclear, cerebrovascular reactivity of some women with migraine without aura may be influenced by prandial state.

Changes in Cerebral Hemodynamics and Hematological Aspects Following Scuba Diving at 5 Meters of Seawater

  • Park, Mi-Ri-Nae;Hyun, Kyung-Yae;Moon, Seong-Min;Kim, Yun-Tae;Kim, Dae-Sik;Kang, Shin-Beum;Choi, Seok-Cheol
    • Biomedical Science Letters
    • /
    • v.14 no.4
    • /
    • pp.219-223
    • /
    • 2008
  • The present study was designed to clarify whether scuba diving at 5 meters of seawater influences cerebral hemodynamics, hematological and biochemical variables. Twenty healthy young men well trained scuba diving participated in this study. The blood flow velocity in the right and left middle cerebral arteries (L-MCAV and R-MCAV), blood pressure (BP), heart rate (HR), CBC and differential count, prothrombin time (PT), activated partial thromboplastin time (aPTT), biochemical variables, D-dimer and interleukin-8 (IL-8) levels were determined before, immediately after scuba diving for 30 min, and after 30 min of rest (Pre-scuba, Scuba and R-30m, respectively). L-MCAV and R-MCAV tended to increase, but the only significant increase was in L-MCAV in Scuba. SBP and HR significantly declined in R-30m compared with those of Pre-scuba and the Scuba. IL-8 levels were elevated in Scuba and R-30m compared with that of Pre-scuba. In Scuba and R-30m, hematological variables except PT and biochemical parameters excluding glucose and lactic acid did not significantly changed in comparison with those of Pre-scuba. PT level at Scuba and glucose level at R-30m significantly declined in Scuba, while lactate level at R-30m increased compared with each in Pre-scuba. However, PT level at Scuba was within a normal range. These results suggest that scuba diving at 5 m of seawater for 30 min has no adverse effects, is safe and useful for improving health. However, further study must be performed to clarify the mechanism of elevated IL-8 level following scuba diving.

  • PDF

Development and Feasibility Study for Phase Contrast MR Angiography at Low Tesla Open-MRI System (저자장 자기공명영상 시스템에서의 위상대조도 혈관조영기법의 개발과 그 유용성에 대한 연구)

  • Lee, Dong-Hoon;Hong, Cheol-Pyo;Lee, Man-Woo;Han, Bong-Soo
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.177-187
    • /
    • 2012
  • Magnetic resonance angiography (MRA) techniques are widely used in diagnosis of vascular disorders such as hemadostenosis and aneurism. Especially, phase contrast (PC) MRA technique, which is a typical non contrast-enhanced MRA technique, provides not only the anatomy of blood vessels but also flow velocity. In this study, we developed the 2- and 3-dimensional PC MRA pulse sequences for a low magnetic field MRI system. Vessel images were acquired using 2D and 3D PC MRA and the velocities of the blood flow were measured in the superior sagittal sinus, straight sinus and the confluence of the two. The 2D PC MRA provided the good quality of vascular images for large vessels but the poor quality for small ones. Although 3D PC MRA gave more improved visualization of small vessels than 2D PC MRA, the image quality was not enough to be used for diagnosis of the small vessels due to the low SNR and field homogeneity of the low field MRI system. The measured blood velocities were $25.46{\pm}0.73cm/sec$, $24.02{\pm}0.34cm/sec$ and $26.15{\pm}1.50cm/sec$ in the superior sagittal sinus, straight sinus and the confluence of the two, respectively, which showed good agreement with the previous experimental values. Thus, the developed PC MRA technique for low field MRI system is expected to provide the useful velocity information to diagnose the large brain vessels.

Noninvasive assessment of pressure gradients across prosthetic heart valve by doppler ultrasound -A comparative studyof the duromedics bileaflet valves in mitral position and normal mitral valves- (도플러 초음파를 이용한 인공판막 상하의 압력차 측정에 관한 연구 -승모판막 치환에 사용한 Duromedics 인공판막과 정사인의 승모판막과의 비교연구-)

  • Jin, Seong-Hun;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.223-229
    • /
    • 1987
  • Doppler echocardiography provides valuable information regarding prosthetic heart valve function rather than structure. There are three methods of expressing the severity of mitral valve obstruction: the transvalvular pressure gradient, effective valve area, and pressure half-time. Of these, the transvalvular pressure gradient [~p] can be determined by the measurement of maximum transvalvular blood flow velocity [V] according to the modified Bernoulli`s equation [gp=4V*]. Eleven patients, who underwent mitral valve replacement with Duromedics mechanical prostheses, and 17 normal persons were investigated. There were significantly higher calculated pressure gradients in prosthetic than normal mitral valves [9.*10*2.22mmHg-vs-3.26*0.99mmHg:p<0,01], and there was a inverse relationship between pressure gradient and prosthetic valve size [11.17*0.%mmHg in size 27mm and 29mm -v- 7.38*1.12mmHg in size 31mm and 33mm; r=0.85, p<0.01] The noninvasive Doppler technique should be useful in the diagnosis of prosthetic valve obstruction.

  • PDF

Microfluidic Device for Ultrasound Image Analysis based on 3D Printing (초음파 영상 분석을 위한 3D 프린팅 기반 미세유체소자)

  • Kang, Dongkuk;Hong, Hyeonji;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.1
    • /
    • pp.15-20
    • /
    • 2018
  • For the measurement of biophysical properties related with cardiovascular diseases (CVD), various microfluidic devices were proposed. However, many devices were monitored by optical equipment. Ultrasound measurement to quantify the biophysical properties can provide new insights to understand the cardiovascular diseases. This study aims to check feasibility of microfluidic device for ultrasound image analysis based on 3D printer. To facilitate acoustic transmission, agarose solution is poured around 3D mold connected with holes of the acrylic box. By applying speckle image velocimetry(SIV) technique, flow information in the bifurcated channel was estimated. Considering that ultrasound signal amplitude is determined by red blood cell (RBC) aggregation, RBC aggregation in the bifurcated channel can be estimated through the analysis of ultrasound signal. As examples of microfluidic device which mimic the CVD model, velocity fields in microfluidic devices with stenosis and aneurysm were introduced.

A Study on A New Two-Dimensional Pulsed Doppler System Using Second-Order Sampling Method. (2차 샘플링을 이용한 새로운 초음파 2차원 펄스 도플러 시스템에 관한 연구)

  • Park, Se-Hyeon;Im, Chun-Seong;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.33-42
    • /
    • 1989
  • The doppler effect is used for measuring the velocity of the blood flow in artery. Because of the range information, the pulsed doppler system is most commonly used. In this paper, we propose a new two-dimensional(2-D) pulsed Doppler system. Which uses second-order sampling method and serial processing. The proposed system using second-order sampling method eliminates in-phase, quadrature-phase balancing problem at demodulator of quadrature detection method. In addition, the new pulsed 2-D doppler system eliminates balancing problem of channels of 2-D doppler system because of serial processing.

  • PDF

Ultrasonic Targeting of NK Cell in Vessel Bifurcation for Immunotherapy: Simulation and Experimental Validation

  • Saqib Sharif;Hyeong-Woo Song;Daewon Jung;Hiep Xuan Cao;Jong-Oh Park;Byungjeon Kang;Eunpyo Choi
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.418-424
    • /
    • 2023
  • Natural killer (NK) cells play a crucial role in combating infections and tumors. However, their therapeutic application in solid tumors is hindered by challenges, such as limited lifespan, tumor penetration, and delivery precision. Our research introduces a novel ultrasonic actuation technique to navigate NK cells more effectively in the vascular system, particularly at vessel bifurcations where targeted delivery is most problematic. We use a hemispherical ultrasonic transducer array that generates phase-modulated traveling waves, focusing on an ultrasound beam to steer NK cells using blood-flow dynamics and a focused acoustic field. This method enables the precise obstruction of non-target vessels and efficiently directs NK cells toward the tumor site. The simulation results offer insights into the behavior of NK cells under various conditions of cell size, radiation pressure, and fluid velocity, which inform the optimization of their trajectories and increase targeting efficiency. The experimental results demonstrate the feasibility of this ultrasonic approach for enhancing NK cell targeting, suggesting a potential leap forward in solid tumor immunotherapy. This study represents a significant step in NK cell therapeutic strategies, offering a viable solution to the existing limitations and promising enhancement of the efficacy of cancer treatments.

How to Treat Peripheral Arteriovenous Malformations

  • Ran Kim;Young Soo Do;Kwang Bo Park
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.568-576
    • /
    • 2021
  • Arteriovenous malformations (AVMs) are direct communications between primitive reticular networks of dysplastic vessels that have failed to mature into capillary vessels. Based on angiographic findings, peripheral AVMs can be classified into six types: type I, type IIa, type IIb, type IIc, type IIIa, and type IIIb. Treatment strategies vary with the types. Type I is treated by embolizing the fistula between the artery and the vein with coils. Type II (IIa, IIb, and IIc) AVM is treated as follows: first, reduce the blood flow velocity in the venous segment of the AVM with coils; second, perform ethanol embolotherapy of the residual shunts. Type IIIa is treated by transarterial catheterization of the feeding arteries and injection of diluted ethanol. Type IIIb is treated by transarterial or direct puncture approaches. A high concentration of ethanol is injected through the transarterial catheter or direct puncture needle. When the fistula is large, coil insertion is required to reduce the amount of ethanol. Type I and type II AVMs showed the best clinical results; type IIIb showed a satisfactory response rate. However, type IIIa showed the poorest response rate, either alone or in combination with other types. Clinical success can be achieved by using different treatment strategies for different angiographic AVM types.

Effects of Sahyangsohap-won on Cerebral Hemodynamics in Healthy Subjects (사향소합원(麝香蘇合元)이 정상인의 뇌혈류역학에 미치는 영향)

  • Koo, Bon-Soo;Kim, Sung-Hwan;Moon, Sang-Kwan;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup;Ryu, Soon-Hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.199-205
    • /
    • 2001
  • Background and Purpose : Transcranial doppler ultrasonography(TCD) is a noninvasive and nonradioactive technique for evaluation of the hemodynamics in large cerebral vessels. Sahyangsohap-won(SS) has been considered to be effective for the treatment of various disease, especially cerebrovascular, cardiovascular, and psychosomatoform disorders. But, there is no study about the effect of SS on the cerebral hemodynamics in humans. The aim of this study was to assess the effect of SS on the changes in cerebral hemodynamics and the dose-dependant effect by using TCD. Subjects and Methods : 30 healthy subjects were randomly divided into three group: group 1 took no drug, group 2 took SS one pill, and group 3 took SS 2 pills. Changes in the mean blood flow velocity(MBFV) and pulsatility index(PI) in the middle cerebral artery were evaluated by means of TCD. We obtained hypercapnia with breath-holding and evaluated cerebrovascular reactivity with the breath-holding index(BHI). Systolic blood pressure(SBP), diastolic blood pressure(DBP), and heart rate(HR) were measured by means of ambulatory blood pressure monitoring. In group 2 and group 3, the evaluations were performed during the baseline and were repeated at 20, 40, and 60 minutes after SS administration. In group 1, the evaluation was performed at corresponding time intervals. Results : In mean values of MSFV, PI, SSP, DBP, and HR, no stastically significant differences were found between the 3 groups. However, BHI values were significantly lower in groups 2 and 3 than in group 1 at 40 minutes after SS administration(P<0.05, group 1 vs group 2, group 1 vs group 3 by post-hoc analysis: Scheffe's test) but in dose-dependant effect, there was no difference between group 2 and group 3. Conclusion : These results suggest that SS can decrease vascular resistance in cerebral small arteries or arterioles and enhance their distensibility. Further studies on larger numbers of subjects are needed to confirm these effects and the dose-dependant effects.

  • PDF

Changes in Total Cerebral Blood Flow with Aging, Parenchymal Volume Changes, and Vascular Abnormalities: a Two-dimensional Phase-Contrast MRI Study (나이와 뇌실질부피 변화 및 혈관이상에 따른 총뇌혈류량 변화: 이차원 위상대조 자기공명영상을 이용한 연구)

  • Liu Haiying;Shin Tae-Beom;Youn Seong-Kuk;Oh Jong-Yong;Lee Young-Il;Choi Sun-Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.17-23
    • /
    • 2004
  • Purpose : To evaluate changes in total cerebral blood flow (tCBF) with aging, parenchymal volume changes and vascular abnormalities, using 2 dimensional (D) phase-contrast magnetic resonance imaging (PC MRI). Materials and Methods : Routine brain MRI including T2 weighted image, time-of-flight (TOF) MR Angiography (MRA) and 2D PC MRI were performed in 73 individuals, including 12 volunteers. Normal subjects (12 volunteers, and 21 individuals with normal MRI and normal MRA) were classified into groups according to age (18-29, 30-49 and 50-66 years). For the group with abnormalities in brain MRIs, cerebral parenchymal volume changes were scored according to the T2 weighted images, and atherosclerotic changes were scored according to the MRA findings. Abnormal groups were classified into 4 groups: (i) mild reduction in volume, (ii) marked reduction in volume by parenchymal volume and atherosclerotic changes, and (iii) increased volume and (iv) Moya-moya disease. Volumetric flow was measured at the internal carotid artery (ICA) and vertebral artery bilaterally using the velocity-flow diagrams from PC MRI, and combined 4 vessel flows and tCBF were compared among all the groups. Results : The age-specific distribution of tCBFs in normal subjects were as follows: $12.0{\pm}2.1ml/sec$ in 18-29 years group, $11.8{\pm}1.9ml/sec$ in 30-49 years group, $10.9{\pm}2.2ml/sec$ in 50-66 years group. The distribution of tCBFs in the different subsets of the abnormal population were as follows: $9.5{\pm}2.5ml/sec$ in the group with mild reduction in volume, $7.6{\pm}2.0ml/sec$ in the group with marked reduction in volume, and $7.3{\pm}1.2ml/sec$ and $7.0{\pm}1.1ml/sec$ in the increased parenchymal volume and Moya-moya disease groups respectively. Conclusion : Total cerebral blood flow decreases with increasing age with a concomitant reduction in parenchymal volumes and increasing atherosclerotic changes. It is also reduced in the presence of increased parenchymal volume and Moya-moya disease.2D PC MRI can be used as a tool to evaluate tCBF with aging and in the presence of various conditions that can affect parenchymal volume and cerebral vasculature.

  • PDF