• Title/Summary/Keyword: bite registration

Search Result 32, Processing Time 0.022 seconds

A simple technique for impression taking of teeth and functionally generated paths

  • Yamamoto, Takatsugu;Sato, Yohei;Watanabe, Hidehiko;Punj, Amit;Abe, Minoru;Momoi, Yasuko;Ohkubo, Chikahiro
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.9.1-9.6
    • /
    • 2018
  • The objective of this case report is to introduce a simple technique for simultaneously taking a closed-mouth impression and functionally generated path (FGP) for a full coverage crown restoration. A monolithic zirconia crown was the restoration of choice. An alginate impression of the abutment tooth was taken to fabricate a custom-made closed-mouth impression tray covering the abutment tooth and the adjacent teeth. The tray had an FGP table and an abutment tray in cameo and intaglio surfaces, respectively. The impression was taken with silicone impression material after adjusting the abutment tray and inscribing the FGP using self-curing acrylic resins. Plaster casts were made from the impression, and a zirconia crown was fabricated. The crown was cemented to the abutment tooth with minimal adjustments. This simple technique resulted in a well-fitting crown that accounted for mandibular movements. Using the custom closed-mouth impression tray incorporating an FGP table simultaneously aids in fabricating an accurately fitting restoration that incorporates harmonious mandibular movements using a single impression capture.

THE EFFECT OF SCREW HOLE SEALING METHOD ON ABUTMENT SCREW LOOSENING IN DENIAL IMPLANT (임플랜트 보철물의 나사구멍 봉쇄방법이 지대나사 풀림에 미치는 영향에 관한 연구)

  • Lim, Jae-Bin;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.767-780
    • /
    • 1997
  • One of the most common problems of implant prosthesis is the screw loosening of abutment screws. This brings on discomfort in mastication, inflammation in the peri-implant tissue due to poor oral hygiene and fracture of prosthesis or loss of osseointegration. To prevent screw loosening, appropriate implantation to direct the occlusal force to the long axis of the implant, accurate design of the superstructure, decrease of the occlusal table, and adequate torque on the abutment screw are necessary. In this study the screw loosening torque was evaluated in implants with dimples or flutes in the internal surface of abutment screw holes. The abutments were fastened with slot type and hexagonal type abutment screws and were sealed with vinyl poly siloxane impression and bite registration material respectively. The screw loosening torque was evaluated after 1,800 and 12,600 times loading under a loading machine. The results were as follows. 1. The flute form group showed significantly higher loosening torque compared to the dimple form group and the group with no inner surface treatment (p<0.05). 2. There was no statistical difference in loosening torque according to the sealing materials. 3. The loosening torque according to the types of abutment screw showed no significant difference. 4. The loosening torque was significantly higher after 1800 times loading compared to 12600 times loading(p<0.05). From the above results. it is thought that formation of a flute in the internal surface of the screw hole decreases the chance of screw loosening, but the sealing materials and types of abutment screw did not show significant difference in prevention of screw loosening.

  • PDF

Current status of dental hygiene curriculum related to clinical practice for dental hygienists in some universities (일부 대학 치위생학과의 치과임상실무 관련 교육과정 운영현황)

  • Lee, Hyo-Jin;Shin, Bo-Mi;Shin, Sun-Jung;Bae, Soo-Myoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.21 no.6
    • /
    • pp.793-803
    • /
    • 2021
  • Objectives: The purpose of this study was to investigate the current status of dental hygiene curricula related to clinical practice in Korea. Methods: Clinical work included the categories 'history taking, infection control, oral prophylaxis, preventive treatment, education/counseling, radiography/reading, assisting/cooperation, impression/bite registration, anesthesia, etc.', and 66 works were finally selected based on the frequent tasks of dental hygienists. The subjects were made to answer nine questionnaires. Results: It was found that the theory and practice of the main works operated quite differently in lectures and practice in each school. All types of practice were applied to all schools in the case of 'scaling'. The evaluation of clinical practice was also found to be very different from school to school. Conclusions: For dental hygienists to establish expertise in clinical practice and promote quality improvement, it is necessary to develop a core curriculum focusing on clinical practice. The standardized curriculum should be improved to an efficient and competency-centered one defining clearly the role of dental hygienists considering the needs and importance of clinical practice.

Complete mouth rehabilitation, using jaw motion tracking and double scan technique in a patient with osteoarthrosis: a case report (골관절증 환자에서 하악 운동 추적 장치와 이중 스캔 기법을 활용한 완전 구강 회복 증례)

  • Seo-Kyung Jeong;Jai-Young Koak;Seong-Joo Heo;Seong-Kyun Kim;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.82-94
    • /
    • 2024
  • This is a case report of complete mouth rehabilitation in a patient with generalized attrition and loss of posterior support. After analyzing the condition of the temporomandibular joint, multiple implants were placed to restore collapsed occlusion. Fixture/abutment level intraoral scanning was done instead of using conventional impression materials which entail multiple bite registration for cross-mounting. A 'jaw motion tracking'device, 'digital face-bow transfer', and 'double scan technique' which enables duplicating temporary restoration to definitive restoration were used to fabricate definitive prostheses. By using various digital techniques, complete mouth rehabilitation was done with minimal chair time in a patient with unstable occlusion.

The treatment of an edentulous patient with DENTCA$^{TM}$ CAD/CAM Denture (CAD/CAM Denture를 이용한 완전 무치악 환자 수복 증례)

  • Park, Joon-Ho;Cho, In-Ho;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease chair time and the number of visits, thus decreasing total fabrication time, expenses and errors caused during fabrication processes. One of the systems using CAD/CAM, DENTCA$^{TM}$ CAD/CAM denture (DENTCA Inc. Los Angeles, USA) scans edentulous impressions, designs dentures digitally, fabricates try-in dentures by 3D printing and converts them into final dentures. Patients can wear final dentures after only 2 - 3 visits with satisfying adaptation. This case report introduces a 71-year-old male patient who visited to consult remaking of existing old dentures. Residual teeth with bad prognosis and root remnants were extracted and the patient used reformed existing mandibular denture for 2 months. And then DENTCA system started. One-step border molding was done using conventional tray of adequate size provided by DENTCA system and wash impression was taken. Gothic arch tracing was completed based on the vertical dimension of existing dentures. Both maxillary and mandibular trays were placed to the resultant centric relation and bite registration was taken. Then DENTCA scanned the bite registration, arranged the teeth, completed the festooning and fabricated the try-in dentures by 3D printing. The try-in dentures were positioned, occlusal plane and occlusal relations were evaluated. The try-in dentures were converted to final dentures. To create bilateral balanced occlusion, occlusal adjustment was done after clinical remounting using facebow transfer. The result was satisfactory and it was confirmed by patient and operator.

RELATIONSHIP BETWEEN CO-CR DISCREPANCY AND FACIAL SKELETAL TYPE (안면골격 형태와 중심교합위-중심위 변위간의 상관성에 관한 연구)

  • Cho, Jin-Young;Lee, Young-Jun;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.839-853
    • /
    • 1998
  • The present study was performed to prove the relationship between CO-CR discrepancy and facial skeletal type. In this study, 242 subjects were randomly selected and devided into 9 groups(devided into class I, II, III by ANB and each one devided into dolicho-, brachy-, mesofacial skeleton by Ricketts' vertical index). Lateral cephalometric radiographs with the mandible in centric occlusion were taken and measured and CO and CR bites were registered on all subjects. Diagnostic casts were mounted on Panadent articulator using an estimated face-bow and centric relation bite registration. The amount and direction of CO-CR discrepancy present was recorded using a Condylar Position Indicator(CPI) and a centric occlusion wax bite registration. CPI measurements and cephalometric measurements were statistically analyzed. The finding of this study can be summerized as follows : 1. There is little correlation between right and left sides for magnitude or direction of CO-CR discrepancies. The correlation between the magnitude of CO-CR discrepancy of left A-P and right A-P is higher than that of left S-I and right S-I. 2. Correlation of Class II malocclusion group was higher than that of the other groups between the magnitude of CO-CR discrepancy of left CPI and right CPI. 3. There is no difference between the pattern of CO-CR discrepancy of 9 malocclusion groups. 4. There is very little, if any, correlation between Skeletofacial measurements and CO-CR discrepancy. 5. In Class II brachyfacial skeleton and Class III mesofacial skeleton there was Lateral cephalometric measurements by that we predict CPI measurements was detected. That was overbite, overjet, upper genial angle, lower genial angle, saddle angle, articular angle, convexity of point A, ANS-Me/Na-Me, PCBL/RH, Posterior FH/anterior FH.

  • PDF

A STUDY OF THE NORMAL & ABNORMAL OCCULSAL PATERNS IN ADULTS USING THE SUPERIMPOSED RUBBER PATTERN METHOD (Superimposed Rubber Pattern법에 의한 성인 정상 및 비정상 교합자의 교합 양상에 관한 연구)

  • Choi, Dae-Gyun;Lee, Sung-Bok;Kwon, Young-Hyuk;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.467-491
    • /
    • 1995
  • In order to analyze the occlusin of intercuspation with maximun bite force, fifteen healthy adult subjects with the ages 23 to 27 were studied(Group1 ; 5-normal occlusion with Angle's Class1, Group2 ; 5-Angle's Class2 malocclusion, Group3 ; 5-Angle’s Class3 malocclusion). Head Position was fixed with occlusal plane paralleling to horizontal line and occlusal registration r cord was made with polyether rubber impression material(Ramitec, ESPECo. West Germany). After all subject were trained for maximum intercuspation at least 5 times, occlusal registration procedure was repeated for this study. Lower posterior rubber occlusal registration records were sliced with 1mm thickness using precision metal sliding channel(Hitachi Ind. Co., Japan). Gross sectional drawings were traced from occluding view of upper and lower posterior teeth on the rubber slices using digitizer, and superimposed for the determination of each drawing distance(Superimposed Rubber Pattern Method). Based on superimposed rubber pattern drawings, total area of occlusal view, sum of each area of the 5 divided occlusal contact provinces and its ratio, total area and number of occlusal contact area were determined to elucidate occlusal stability in the normal and abnormal occlusion groups. The data were analysed by t-test(p=0.05) to determine statistical significance. The obtained results were as follows : 1. Group1 showed the largest standard area with occlusal view of the lower posterior teeth and Group3 showed the smallest area. There was a significant difference between Group2 and Group3(p=0.025), and Gropu1 was not statistically different for both Group2 and Group3. 2. Means and ratio of the under 2.0mm area(D) and ratio showed $197.49mm^2$, 59.76% in Group1, $188,69mm^2$, 56.10% in Group2, and $174.23mm^2$, 55.76% in Group3. The results that Group1 has the most area/ratio and Group3 has the least area/ratio can be considered Group1 is the most advantageous for masticatory effective area, and Group3 is the least adnantageous. 3. Means and ratio of the under 1.0mm area(C) were $198.96mm^2$, 42.65% in Group1, 123.06$mm^2$, 46.58% in Group2, and $92.24mm^2$, 29.52% in Group3. These data means that Group1 is the most advantageous in terms of masticatory effective area and Group3 is the least. 4. Means and ratio of the under 0.5mm area(B) were $86.68mm^2$, 26.68% in Group1, $62.98mm^2$, 18.71% in Group2, and $36.44mm^2$, 11.66% in Group3. These can also be considered Group1 is the most advantageous for masticatory effective area and occlusal stability. 5. Means and ratio of the under 0.05mm area(A) were $30.92mm^2$, 9.21% in Group1, $14.31mm^2$, 4.25% in Group2, and $7.59mm^2$, 2.43% in Group3. The area ratio of the each subject group was(4.1) : (1.9) : (1)and the data of the under 0.05mm area has the intimate relationship with inter-group and intra-group data/ratio. 6. First molar showed the most occlusal contact points in all subject group and Group1 showed somewhat uniformly distributed occlusal contact point except first premolar. In Group2, all contact point in posterior teeth showed significantly reduced distribution except first molar. Group3 showed evenly distributed contace points in first and second molars.

  • PDF

A STUDY ON MASTICATORY PERFORMANCE AND MUSCLE ACTIVITY IN REMOVABLE PARTIAL DENTURE WEARERS (자연치열자와 가철성 국소의치 장착자의 저작효율과 근활성도에 관한 비교 연구)

  • Paik, Jin;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.81-103
    • /
    • 1998
  • The purpose of this study was to compare and evaluate the differences in masticatory performance, muscle activity, and patterns of occlusal contact between persons with natural dentition and removable partial denture wearers. Twenty healthy adult subjects with more than 28 teeth and thirteen removable partial denture wearers that classified Kennedy classification I was selected. The degree of pulverized rice and peanut was measured and analyzed by means of sieving method to compare the masticatory performance. For the muscle activity, EMG was recorded in selected muscles(Temporalis and masseter muscle) during mastication and resting state. The occlusal record in maximal intercuspation was taken with a silicone occlusal bite registration material for analysis of the patterns of occlusal contact. The obtained results were as follows: 1. When chewed peanuts, masticatory performance ratio at 10-sieve size was 81.31% in natural dentition group. In removable partial denture wearer, 27.01% without RPD and 69.09% with RPD. When chewed rice, 42.04%, 11.87%, and 21.58%, respectively. The differences of masticatory performance ratio between groups were statistically significant at the 0.05 level. 2. The mean EMG value in resting state was $1.06{\mu}V$ on temporal muscle, $0.98{\mu}V$ on masseter muscle in natural dentition group. In removable partial denture wearers, $1.13{\mu}V$ on temporal muscle, $1.05{\mu}V$ on masseter muscle without RPD and $1.11{\mu}V$ on temporal muscle, $1.04{\mu}V$ on masseter muscle with RPD. 3. The mean EMG value during mastication was $45.64{\mu}V$ in natural dentition group, and in removable partial denture wearers, $22.06{\mu}V$ without RPD and $31.01{\mu}V$ with RPD when chewed peanuts. When chewed rice, $45.24{\mu}V,\;25.53{\mu}V\;and\;32.14{\mu}V$, respectively. The differences of mean masticatory EMG value between groups were statistically significant at the 0.05 level. 4. The number of posterior occlusal contact point was 20.15 in natural dentition group and 11.92 in removable partial denture wearers. The area of perforated surface was $16.50mm^2$ in natural dentition group and $6.06mm^2$ in removable partial denture wearers. The area of contact surface was $78.93mm^2,\;51.52mm^2$, respectively. 5. The area of contact surface was effective to masticatory performance ratio in natural dentition group and removable partial denture wearers (p<0.05). From these results, it is concluded that in partially edentulous patient, masticatory efficiency can be improved by removable partial denture wearing, and for efficient mastication, tight occlusal contact surface shoud be maintained by maximum support that is provided from mucosa.

  • PDF

A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY (개별 치아 트레이의 재료와 형태에 따른 인상체의 정밀성에 관한 연구)

  • Ryu, Duck-Woo;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.242-254
    • /
    • 2000
  • Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin. $Futar^{(R)}$ occlusion. $Blu-mousse^{(R)}$) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by $X-PLAN360d^{(R)}$ to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows: 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm-marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less marginal discrepancy than groups with 0.5mm-marginal-vent-space (p<0.05). In summary these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.

  • PDF

Computer-guided implant surgery and immediate provisionalization by chair-side CAD-CAM: A case report (진료실 CAD-CAM에 의한 컴퓨터 가이드 임플란트 수술과 즉시 임시보철치료: 증례보고)

  • Hyun, Sang Woo;Lee, sungbok Richard;Lee, Suk Won;Cho, Young Eun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.478-486
    • /
    • 2021
  • This report demonstrates a method of generating a chair-side and computer-aided template for implant surgery based on the Top-Down and restoration-driven concept. Compared to the traditional CAD-CAM process which requires multiple steps to be taken between dental clinic and laboratory, this alternative procedure, VARO guide system (VARO Guide, CAD, Pre-Guide, VARO-mill, NeoBiotech, Seoul, South Korea) enables accurate and patient-friendly implant surgery as well as immediate provisional restoration in a single visit. First, bite-registration at centric jaw relation and CBCT were taken using the Pre-Guide. The CBCT data was then reorganized directly through the chair-side CAD, and we could determine the most appropriate 3-dimensional position of implant. The STL file was extracted and put into the chair-side CAM (VARO-mill) to fabricate a VARO. This surgical guide allowed the implants to be accurately positioned into the planned sites within an hour.