• Title/Summary/Keyword: biosensor-based methods

Search Result 43, Processing Time 0.03 seconds

Evaluation of Antibody Immobilization Methods for Detection of Salmonella using Impedimetric Biosensor (살모넬라균 검출을 위한 임피던스 바이오센서의 항체 고정화 방법 평가)

  • Kim, Gi-Young;Moon, Ji-Hea;Om, Ae-Son;Yang, Gil-Mo;Moh, Chang-Yeon;Kang, Suk-Won;Cho, Han-Keun
    • Journal of Biosystems Engineering
    • /
    • v.34 no.4
    • /
    • pp.254-259
    • /
    • 2009
  • Conventional methods for pathogen detection and identification are labor-intensive and take several days to complete. Recently developed biosensors have shown potential for the rapid detection of foodborne pathogens. In this study, an impedimetric biosensor was developed for rapid detection of Salmonella typhimurium. To develop the biosensor, an interdigitated microelectrode (IME) was fabricated by using semiconductor fabrication process. Anti-Salmonella antibodies were immobilized based on either avidin-biotin binding or self assembled monolayer (SAM) on the surface of the IME to form an active sensing layer. To evaluate effect of antibody immobilization methods on sensitivity of the sensor, detection limit of the biosensor was analyzed with Salmonella samples innoculated in phosphate buffered saline (PBS) or food extract. The impedimetric biosensor based on SAM immobilization method produced better detection limit. The biosensor could detect 107 CFU/mL of Salmonella in pork meat extract. This method may provide a simple, rapid, and sensitive method to detect foodborne pathogens.

Development of a Fiber-Optic Biosensor for the Detection of Listeria monocytogenes (리스테리아 식중독균 검출을 위한 광학식 바이오센서 개발)

  • Kim G.;Choi K.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.2 s.115
    • /
    • pp.128-134
    • /
    • 2006
  • Frequent outbreaks of foodborne illness demand the need for rapid and sensitive methods for detection of these pathogens. Recent development of biosensor technology has a great potential to meet the need for rapid and sensitive pathogens detection from foods. An antibody-based fiber-optic biosensor and an automated reagents supply system to detect Listeria monocytogenes were developed. The biosensor for detection of Listeria monocytogenes in PBS and bacteria spiked food samples was evaluated. The automated reagents supply system eliminated cumbersome sample and detection antibody injection procedures that had been done manually. The biosensor could detect $10^4$ cfu/ml of Listeria monocytogenes in PBS. By using the fiber-optic biosensor, $2x10^8$ cfu/ml of Listeria monocytogenes in the food samples were detectable.

Online Multi-Task Learning and Wearable Biosensor-based Detection of Multiple Seniors' Stress in Daily Interaction with the Urban Environment

  • Lee, Gaang;Jebelli, Houtan;Lee, SangHyun
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.387-396
    • /
    • 2020
  • Wearable biosensors have the potential to non-invasively and continuously monitor seniors' stress in their daily interaction with the urban environment, thereby enabling to address the stress and ultimately advance their outdoor mobility. However, current wearable biosensor-based stress detection methods have several drawbacks in field application due to their dependence on batch-learning algorithms. First, these methods train a single classifier, which might not account for multiple subjects' different physiological reactivity to stress. Second, they require a great deal of computational power to store and reuse all previous data for updating the signle classifier. To address this issue, we tested the feasibility of online multi-task learning (OMTL) algorithms to identify multiple seniors' stress from electrodermal activity (EDA) collected by a wristband-type biosensor in a daily trip setting. As a result, OMTL algorithms showed the higher test accuracy (75.7%, 76.2%, and 71.2%) than a batch-learning algorithm (64.8%). This finding demonstrates that the OMTL algorithms can strengthen the field applicability of the wearable biosensor-based stress detection, thereby contributing to better understanding the seniors' stress in the urban environment and ultimately advancing their mobility.

  • PDF

The Eukaryote Alternative: Advantages of Using Yeasts in Place of Bacteria in Microbial Biosensor Development

  • Walmsley, Richard M.;Keenan, Patrick
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.6
    • /
    • pp.387-394
    • /
    • 2000
  • The relationship between Man and yeast has been a successful and enduring one. The characteristics of yeast have made it an ideal tool in scientific research and as such, it has been used extensively. In this review some of the advantages, methods and applications of yeasts in the biosensor field are outlined. In doing so, we propose a eukaryotic alternative to the current battery of bacteria-based microbial biosensors.

  • PDF

Novel Approach of a Phage-Based Magnetoelastic Biosensor for the Detection of Salmonella enterica serovar Typhimurium in Soil

  • Park, Mi-Kyung;Chin, Bryan A.
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.12
    • /
    • pp.2051-2059
    • /
    • 2016
  • To date, there has been no employment of a magnetoelastic (ME) biosensor method to detect Salmonella enterica serovar Typhimurium in soil. The ME biosensor method needs to be investigated and modified for its successful performance. The filtration method, cation-exchange resin method, and combinations of both methods were employed for the extraction of S. Typhimurium from soil. The number of S. Typhimurium and the resonant frequency shift of the ME sensor were then compared using a brilliant green sulfa agar plate and an HP 8751A network analyzer. A blocking study was performed using bovine serum albumin (BSA), polyethylene glycol (PEG), and casein powder suspension. Finally, the modified ME biosensor method was performed to detect S. Typhimurium in soil. The number of S. Typhimurium was significantly decreased from 7.10 log CFU/soil to 4.45-4.72 log CFU/soil after introduction of the cation-exchange resin method. The greatest resonant frequency shift of the measurement sensor was found when employing centrifugation and filtration procedures. The resonant frequency shift of the PEG-blocked measurement sensor was $3,219{\pm}755Hz$, which was significantly greater than those of the BSA- and casein-blocked ME sensor. The optimum concentration of PEG was determined to be 1.0 mg/ml after considering the resonant shift and economic issue. Finally, the modified ME biosensor method was able to detect S. Typhimurium in soil in a dose-response manner. Although these modifications of the ME biosensor method sacrificed some advantages, such as cost, time effectiveness, and operator friendliness, this study demonstrated a novel approach of the ME biosensor method to detect S. Typhimurium in soil.

Genetically Encoded Biosensor Engineering for Application in Directed Evolution

  • Yin Mao;Chao Huang;Xuan Zhou;Runhua Han;Yu Deng;Shenghu Zhou
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.10
    • /
    • pp.1257-1267
    • /
    • 2023
  • Although rational genetic engineering is nowadays the favored method for microbial strain improvement, building up mutant libraries based on directed evolution for improvement is still in many cases the better option. In this regard, the demand for precise and efficient screening methods for mutants with high performance has stimulated the development of biosensor-based high-throughput screening strategies. Genetically encoded biosensors provide powerful tools to couple the desired phenotype to a detectable signal, such as fluorescence and growth rate. Herein, we review recent advances in engineering several classes of biosensors and their applications in directed evolution. Furthermore, we compare and discuss the screening advantages and limitations of two-component biosensors, transcription-factor-based biosensors, and RNA-based biosensors. Engineering these biosensors has focused mainly on modifying the expression level or structure of the biosensor components to optimize the dynamic range, specificity, and detection range. Finally, the applications of biosensors in the evolution of proteins, metabolic pathways, and genome-scale metabolic networks are described. This review provides potential guidance in the design of biosensors and their applications in improving the bioproduction of microbial cell factories through directed evolution.

Advances in Rapid Detection Methods for Foodborne Pathogens

  • Zhao, Xihong;Lin, Chii-Wann;Wang, Jun;Oh, Deog Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.3
    • /
    • pp.297-312
    • /
    • 2014
  • Food safety is increasingly becoming an important public health issue, as foodborne diseases present a widespread and growing public health problem in both developed and developing countries. The rapid and precise monitoring and detection of foodborne pathogens are some of the most effective ways to control and prevent human foodborne infections. Traditional microbiological detection and identification methods for foodborne pathogens are well known to be time consuming and laborious as they are increasingly being perceived as insufficient to meet the demands of rapid food testing. Recently, various kinds of rapid detection, identification, and monitoring methods have been developed for foodborne pathogens, including nucleic-acid-based methods, immunological methods, and biosensor-based methods, etc. This article reviews the principles, characteristics, and applications of recent rapid detection methods for foodborne pathogens.

Rapid Detection of Salmonella enteritidis in Pork Samples with Impedimetric Biosensor: Effect of Electrode Spacing on Sensitivity

  • Kim, Gi-Young;Moon, Ji-Hea;Hahm, Bung-Kwon;Morgan, Mark;Bhunia, Arun;Om, Ae-Son
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.89-94
    • /
    • 2009
  • Frequent outbreaks of foodborne illness have been increasing the awareness of food safety. Conventional methods for pathogen detection and identification are labor-intensive and take days to complete. Some immunological, rapid assays are developed, but these assays still require prolonged enrichment steps. Recently developed biosensors have shown potential for the rapid detection of foodborne pathogens. In this study, an impedimetric biosensor was developed for rapid detection of Salmonella entritidis in food sample. To develop the biosensor, an interdigitated microelectrode (IME) was fabricated by using a semiconductor fabrication process. Anti-Salmonella antibodies were immobilized based on neutravidin-biotin binding on the surface of the IME to form an active sensing layer. To evaluate the effect of electrode gap on sensitivity of the sensor, 3 types of sensors with different electrode gap sizes (2, 5, and $10{\mu}m$) were fabricated and tested. The impedimetric biosensor could detect $10^3\;CFU/mL$ of Salmonella in pork meat extract with an incubation time of 5 min. This method may provide a simple, rapid, and sensitive method to detect foodborne pathogens.

Development of an Immunosensor to Detect Rat IgG Using Impedance Analyser

  • No D. H.;Kang S.;Kim G. Y.;Chung S. H.;Park Y. H.;Om A. S.;Cho S. I.
    • Agricultural and Biosystems Engineering
    • /
    • v.5 no.1
    • /
    • pp.21-24
    • /
    • 2004
  • Antibody based biosensors are very selective and ultra-sensitive. Antigen-antibody reactions have been used in immunoassays. In this research, a biosensor which uses antigen-antibody reaction was developed to measure and detect rat IgG. Because the antigen-antibody reaction is a physical bounding between antigen and antibody, there are several ways to measure an antigen-antibody reaction. Among the methods, impedance analysis has short measuring time and possibilities of analyzing various properties of the reaction using frequency analysis. Rat IgG could be detected with developed biosensor and impedance analyzer. The biosensor showed good repeatability and availability of detecting concentration changes of rat IgG.

  • PDF

Simultaneous Determination of Glucose and Ethanol of Takju by Biosensor using Dual Cathode Electrode (Dual Cathode Electrode를 이용한 바이오센서로 탁주 중의 포도당 및 에탄올의 동시 측정)

  • Park, In-Seon;Kim, Jung-Ho;Kim, Tae-Jin;Kim, Nam-Soo;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.974-980
    • /
    • 1996
  • A biosensor was prepared with dual cathode electrode and immobilized enzyme membrane. A nylon net was used for the immobilization of glucose oxidase and alcohol oxidase. The immobilized enzymes were placed on the surface of the electrode which was prepared with one anode and two cathodes as an oxygen electrode. The determination of components by the biosensor was based on the consumption of dissolved oxygen. The optimum condition of this system was 0.1 M potassium phosphate buffer solution, pH 7.5 at $35^{\circ}C$. Glucose and ethanol in takju were simultaneously determined by the biosensor. Comparing with UV-spectrophotometer and gas chromatograph for cross checking, there was a good correlation between the biosensor and the conventional methods. Biosensor with dual cathode electrode required no clarification or pretreatments. It was used for simultaneous determination of glucose and ethanol during the fermentation of takju.

  • PDF