• 제목/요약/키워드: biomechanical complication

검색결과 15건 처리시간 0.021초

Biomechanical Complications : 파절과 나사풀림 (Biomechanical Complications : Fracture and Screw loosening)

  • 김태인
    • 대한치과의사협회지
    • /
    • 제53권5호
    • /
    • pp.307-317
    • /
    • 2015
  • Although the long-term success of osseointegrated endosseous implants for the support of fixed dental prostheses has been reported, the increasingly widespread use of implant-supported prostheses has led to problems associated with their structural integrity. The most common biomechanical complications observed in dental implant treatment are fracture and screw loosening. The nature of loosening or fracture of dental implant components is complex, since it involves fatigue, fitness, and varied chewing patterns and loads. To assess the service life of the components of the prosthetic system, a knowledge of the loads transmitted through the system is necessary. Design of the final restoration and occlusion in relation to the geometry of a prosthetic restoration has a great influence on the mechanical loading of the implant. It is proposed that control of force in oral cavity may play a larger role in failures than previously believed. Based on theoretic consideration and clinical experiences with dental implant, this article gives simple guidelines for controlling these loads.

Pyrocarbon hemiarthroplasty and the shoulder: biomechanical and clinical results of an emerging treatment option

  • Mohamad Y. Fares;Jaspal Singh;Peter Boufadel;Matthew R. Cohn;Joseph A. Abboud
    • Clinics in Shoulder and Elbow
    • /
    • 제27권1호
    • /
    • pp.117-125
    • /
    • 2024
  • While shoulder hemiarthroplasty is still used to treat young patients with shoulder pathology, the use of this procedure has substantially declined in recent years due to its significant complication profile. Glenoid wear with arthrosis is one of the major postoperative complications following shoulder hemiarthroplasty, and efforts to prevent this complication led many scientists to explore alternative weight-bearing surfaces on arthroplasty implants to decrease joint wear and improve patient outcomes. Pyrolytic carbon, or pyrocarbon, is a material that has better biocompatibility, survivorship, strength, and wear resistance compared to the materials used in traditional shoulder hemiarthroplasty. Pyrocarbon implants have been used in orthopedics for over 50 years; recently, their utility in shoulder hemiarthroplasty has garnered much interest. The purpose behind the use of pyrocarbon in shoulder hemiarthroplasty is to decrease the risk of progressive glenoid wear, especially in young active patients in whom joint preservation is important. Promising survivorship and outcomes have been demonstrated by recent studies, including limited glenoid wear following pyrocarbon hemiarthroplasty. Nevertheless, these clinical studies have been limited to relatively small case series with limited long-term follow-up. Accordingly, additional research and comparative studies need to be conducted in order to properly assess the therapeutic efficacy and value of pyrocarbon hemiarthroplasty.

유한요소법을 이용한 인두의 기능이상에 대한 생체역학적 모델 (A Biomechanical Modeling of Human Pharyngeal Muscular Dysfunction by Using FEM(Finite Element Method))

  • 김성재;배하석;최병철;김성민
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권6호
    • /
    • pp.515-522
    • /
    • 2003
  • 인두는 구강과 식도, 비강과 폐의 중간에서 능동적으로 구강을 통해 섭취되는 음식물과 비강을 통해 흡입되는 공기의 통로역할을 하는 주요한 기관이다. 본 연구는 유한요소기법을 이용한 인두의 3차원 구조의 재구성 과정을 거쳐 인두의 생체역학모델을 구현하였으며, 연하곤란환자의 인두근육의 주요부분에 대한 구조적 변형특성을 3가지로 분류하여 유한요소기법을 이용하여 인두내의 압력에 대한 형상의 변형을 관찰 후 최적화 과정을 거쳐 각 부분에서의 추정 압력 구배를 측정하여 연하과정에서 내부에 생성되는 압력의 연속적인 압력분포를 추정하였다. CT에 의한 인두의 변형 형상을 추정하여 임의 압력에 의한 인두구조의 변형 형상을 유한요소 해석에 의해 계산한 후 비교하여 실제 인두강 내에 형성되는 압력을 추정하였다. 재료적 특성은 인두의 기능이상 시 근조직경화가 발생, 즉 stiffness 가 증가하는 것으로 가정하여 응력-변형률 관계에 있어서 각각 $25\%,\;50\%,\;75\%$씩 증가시켜 분석하였다. 이러한 인두의 생체역학모델은 인두기능장애를 가진 환자의 치료 계획 수립에 도움이 되는 유용한 자료를 제공 할 것으로 생각된다.

Combination of Anterior and Posterior Subcutaneous Internal Fixation for Unstable Pelvic Ring Injuries: The "Hula Hoop Technique"

  • Balbachevsky, Daniel;Pires, Robinson Esteves;Sabongi, Rodrigo Guerra;Lins, Theophilo Asfora;Carvalho, Geiser de Souza;Fernandes, Helio Jorge Alvachian;Reis, Fernando Baldy dos
    • Journal of Trauma and Injury
    • /
    • 제32권1호
    • /
    • pp.51-59
    • /
    • 2019
  • Unstable pelvic ring lesions are usually treated with internal fixation. In patients presenting clinical instability or soft tissue complication risk, external fixation is a safe treatment option. However, pin tract infection, insufficient biomechanical properties, difficulty sitting and changing decubitus are important drawbacks related to the treatment. The present study reports the association of anterior and posterior subcutaneous internal fixation by applying spine-designed implants on the pelvic ring disruption: supra-acetabular pedicle screws with an interconnecting rod (Infix), plus posterior transiliac fixation with the same system, which the authors have named the "Hula Hoop Technique".

역행성 견관절 전치환술: 임상 결과와 합병증 예방 (Reverse Total Shoulder Arthroplasty: Clinical Results and Prevention of Complications)

  • 이용걸;윤승민;이성민
    • 대한정형외과학회지
    • /
    • 제56권5호
    • /
    • pp.367-376
    • /
    • 2021
  • 역행성 견관절 전치환술은 우리나라에 2007년에 도입된 이래로 행해지는 수가 빠르게 증가하고 있다. 이번 종설을 통해서 역행성 견관절 전치환술이 개발된 생역학적 기전과 수술의 결과에 대해 논하고자 한다. 또한 수술 후 발생할 수 있는 합병증을 최소화시킬 수 있는 방법과 발생 시 대처방안에 대해서도 알아보고자 한다.

Load response of the natural tooth and dental implant: A comparative biomechanics study

  • Robinson, Dale;Aguilar, Luis;Gatti, Andrea;Abduo, Jaafar;Lee, Peter Vee Sin;Ackland, David
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권3호
    • /
    • pp.169-178
    • /
    • 2019
  • PURPOSE. While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. MATERIALS AND METHODS. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. RESULTS. For the natural tooth, the maximum vonMises stress (6.4 MPa) and maximal principal strains at the mandible ($1.8m{\varepsilon}$, $-1.7m{\varepsilon}$) were lower than those observed at the prosthetic tooth (12.5 MPa, $3.2m{\varepsilon}$, and $-4.4m{\varepsilon}$, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. CONCLUSION. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.

Radiologic Evaluation of Proper Pedicle Screw Placement after Pedicle Screw Fixation in Degenerative Lumbar Disc Disease

  • Ju, Sun-Min;Kim, Young-Soo;Kim, Sung-Bum;Ko, Yong;Oh, Seong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권4호
    • /
    • pp.265-268
    • /
    • 2005
  • Objective : With the increasing popularity of pedicle screw fixation devices for several indications, the safety and reliability of screw insertion in the small pedicle has become a major issue. Many studies have investigated the accuracy of screw placement after pedicle screw fixation using various method. The reported displacement rates have been very different. The purpose of the study is to investigate the proper placement of pedicle screw insertion in the lumbar spine on 26 consecutive patients. Methods : Between September and December 2003, 26 consecutive patients [16women and 10men] were analyzed after transpedicular screw fixation of the lumbar and lumbosacral spine. After pedicle screw fixation in this study, 2-mm slices of CT scan were performed in all patients to detect caudal and cranial deviation of screw and medial and lateral deviation. Pedcile screw placement related complication was evaluated clinically. Results : A total of 144 inserted pedicle were analyzed in 26patients, and 58pedicle screws [40.3%] were detected to be improper placement. There were 14level [9.0%] of caudal or cranial deviation and 44level [30.6%] of medial or lateral deviation to the pedicle. Extra-pedicle placement was found on 4levels [2.7%] with only lease of neurologic injury. Conclusion : Proper screw placement, though complication rate is low, is important not only for clinical symptom but also for biomechanics. Further study for screw placement related biomechanical changes is needed.

Clinical and scanning electron microscopic analysis of fractured dental implants: a retrospective clinical analysis

  • Kwon, Kyung-Hwan;Sim, Kyu-Bong;Cha, Jae-Won;Kim, Eun-Ja;Lee, Jae-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제38권6호
    • /
    • pp.371-378
    • /
    • 2012
  • Many longitudinal studies have reported the successful osseointegration of dental implants, with survival rates approaching 90-95%. However, implants regarded as a "success" may have also failed to undergo osseointegration. A variety of complications and failures have been observed, including implant fracture - a rare and delayed biomechanical complication with serious clinical outcomes. Given the increasing popularity of dental implants, an increase in the number of failures due to late fractures is expected. This study sought to determine the rate of implant fractures and factors associated with its development. This retrospective evaluation analyzed implants placed at Wonkwang Dental Hospital (from 1996 to the present). In our study we found that the frequency of dental implant fractures was very low (0.23%, 8 implant fractures out of 3,500 implants placed). All observed fractures were associated with hybrid-surface threaded implants (with diameter of 4.0 or 3.75 mm). Prosthetic or abutment screw loosening preceded implant fracture in a majority of these cases.

대퇴골두 무혈성 괴사증의 수술적 기법 적용 후 괴사 망상골 내에서의 응력 변화 해석 (An Analysis of Stress Transfer Behaviors within the Necrotic Cancellous Bone following Surgical Procedures or the Management of the Osteonecrosis of the Femoral Head)

  • 정성;이성재
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.245-248
    • /
    • 1997
  • Operative interventions for the management of osteonecrosis of the femoral head (ONFH) include core drilling, with or without vascularized fibular bone grafting. Nevertheless, their clinical results have not been consistently satisfactory. Recently, a new surgical procedure that incorporates cementation with polymethylmethacrylate (PMMA) after core drilling has been tried clinically. In this study, a biomechanical analysis using a finite element method(FEM) was undertaken to evaluate surgical methods and their underlying surgical parameter. Our finite element models included five types. They were (1) normal model (Type I), (2) necrotic model (Type II), (3) core decompressed model (Type III). (4) fibular bone grafted model (Type IV), and (5) cemented with PMMA model (Type V). The geometric dimensions of the femur were based on digitized CT-scan data of a normal person. Various physiological loading conditions and surgical penetration depths by the core were used as mechanical variables to study their biomechanical contributions in stress transfer within the femoral head region. In addition. the peak von Mises stress(PVMS) within the necrotic cancellous bone of the femoral head was obtained. The fibular bone grafted method and cementation method provided optimal stress transfer behaviors. Here. substantial increase in the low stress level was observed when the penetration depth was extended to 0mm and 5mm from the subchondral region. Moreover, significant decrease in PVMS due to surgery was observed in the fibular bone grafted method and the cementation method when the penetration depths were extended up to 0 and 5mm from the subchondral region. The drop in PVMS was greater during toe-off than during heel-strike (57% vs. 28% in Type IV and 49% vs. 22% in Type V). Both the vascularized fibular bone grafting method (Type IV) and the new PMMA technique (Type V) appear to be very effective in providing good stress transfer and reducing the peak Von-Mises stress within the necrotic region. Overall results show that fibular bone grafting and cementation methods are quite similar. In light of above results, the new cementation method appears to be a promising surgical alternative or the treatment of ONFH. The use of PMMA for the core can be less prone to surgical complication as opposed to preparation of fibular bone graft and can achieve more immediate fixation between the core and the surrounding region.

  • PDF

견관절 역행성 인공관절 치환술의 원칙 (Reverse Total Shoulder Arthroplasty: Where we are? "Principles")

  • 노규철;서일우
    • Clinics in Shoulder and Elbow
    • /
    • 제14권1호
    • /
    • pp.105-110
    • /
    • 2011
  • 목적: 견관절 역행성 인공관절 치환술의 합병증을 이해하고 이에 대한 최신의 예방 및 치료 방법을 고찰하는 것이 본 논문의 목적이다. 대상 및 방법: 기존의 구속형 인공관절 기구 (구-소켓 관절 혹은 역행성 구형 관절 디자인)는 견갑골의 외측에 회전 중심이 유지되어 제한된 관절 운동과 관절와 기구에 발생한 과도한 회전력으로 인해 조기 해리를 유발하여 실패해왔다. Grammont 역행성 인공관절 기구는 삼각근이 작용하는 새로운 생역학적 환경을 도입하여 회전근개 결손을 보상할 수 있도록 해준다. 결과: 임상적 경험이 생역학 개념에 부응하면 역행성 인공관절은 회전근 개 결손 견관절 환자에서 $90^{\circ}$이상의 능동적 거상을 회복하게 한다. 그러나 외회전은 특히 소원근 지방침윤 내지 결손이 있는 환자들에서는 종종 제한이 남는다. 내회전 역시 역행성 인공관절 후에는 거의 회복되지 않는다. 삼각근에 충분한 긴장을 회복하지 못하면 인공관절 불안성이 초래된다. 결론: 인공관절 치환술 후 재수술에서 그 결과는 예측가능성이 떨어지고, 합병증 및 재치환술 비율이 더 높음을 인지해야만 한다. 합병증을 인지하고 예방하기 위해서는 명확한 정의와 평가 지침을 포함한 표준화된 감시 장치가 필요할 것으로 사료된다.