Browse > Article

Radiologic Evaluation of Proper Pedicle Screw Placement after Pedicle Screw Fixation in Degenerative Lumbar Disc Disease  

Ju, Sun-Min (Department of Neurosurgery, Hanyang University College of Medicine)
Kim, Young-Soo (Department of Neurosurgery, Hanyang University College of Medicine)
Kim, Sung-Bum (Department of Neurosurgery, Hanyang University College of Medicine)
Ko, Yong (Department of Neurosurgery, Hanyang University College of Medicine)
Oh, Seong-Hoon (Department of Neurosurgery, Hanyang University College of Medicine)
Publication Information
Journal of Korean Neurosurgical Society / v.38, no.4, 2005 , pp. 265-268 More about this Journal
Abstract
Objective : With the increasing popularity of pedicle screw fixation devices for several indications, the safety and reliability of screw insertion in the small pedicle has become a major issue. Many studies have investigated the accuracy of screw placement after pedicle screw fixation using various method. The reported displacement rates have been very different. The purpose of the study is to investigate the proper placement of pedicle screw insertion in the lumbar spine on 26 consecutive patients. Methods : Between September and December 2003, 26 consecutive patients [16women and 10men] were analyzed after transpedicular screw fixation of the lumbar and lumbosacral spine. After pedicle screw fixation in this study, 2-mm slices of CT scan were performed in all patients to detect caudal and cranial deviation of screw and medial and lateral deviation. Pedcile screw placement related complication was evaluated clinically. Results : A total of 144 inserted pedicle were analyzed in 26patients, and 58pedicle screws [40.3%] were detected to be improper placement. There were 14level [9.0%] of caudal or cranial deviation and 44level [30.6%] of medial or lateral deviation to the pedicle. Extra-pedicle placement was found on 4levels [2.7%] with only lease of neurologic injury. Conclusion : Proper screw placement, though complication rate is low, is important not only for clinical symptom but also for biomechanics. Further study for screw placement related biomechanical changes is needed.
Keywords
Pedicle screw; Accuracy; CT scan;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Acikbas SC, Arslan FY, Tuncer MR : The effect of transpedicular screw misplacement on late spinal stability. Acta Neurochir 145 : 949-955, 2003   DOI   ScienceOn
2 Castro WHW, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S : Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21 : 1320-1324, 1996   DOI   ScienceOn
3 Faraj AA, Akasha K, Mulholland RC : Temporary external fixation for low back pain : Is it worth doing? Eur Spine J 6 : 187-190, 1997   DOI   ScienceOn
4 Jutte PC, Castelein RM : Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 11 : 594-598, 2002   DOI   ScienceOn
5 Kang DS, Jung MH, Ahn CS, Ban SS, Choi SW, Choe IS, et al : Morphometric Study of the Pedicles of Lumbar Vertebrae in Koreans. J Korean Neurosurg Soc 28 : 1692-1698, 1999
6 Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S : Spinal pedicle fixation : reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13 : 1012- 1018, 1988   DOI   ScienceOn
7 Esses SI, Botsford DJ, Kostuik JP : The role of external spinal skeletal fixation in the assessment of low back pain. Spine 14 : 594-601, 1989   DOI   ScienceOn
8 Farber GL, Place HM, Mazur RA, Casey Jones DE, Damiano TR : Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine 20 : 1494-1499, 1995   DOI   PUBMED   ScienceOn
9 Harrington PR, Tullos HS : Reduction of severe spondylolisthesis in children. South Med J 62 : 1-7, 1969   PUBMED
10 Wiesner L, Kothe R, Schulitz KP, Ruther W : Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. Spine 25 : 615-621, 2000   DOI   ScienceOn
11 Schwarzenbach O, Berlemann U, Jost B, Visarius H, Arm E, Langlotz F, et al : Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis. Spine 22 : 452-458, 1997   DOI   ScienceOn
12 Roy-Camille R, Saillant G, Mazel C : Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop 203 : 7-17, 1988
13 Heim SE : Transpedicle instrumentation in the degenerative spine. Clin Orthop 337 : 97-110, 1997   DOI   ScienceOn
14 Gertzbein SD, Robbins SE : Accuracy of pedicular screw placement in vivo. Spine 15 : 11-14, 1990   DOI   ScienceOn
15 Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H : Improved accuracy of pedicle screw insertion with computerassisted surgery : A prospective clinical trial in 30patients. Spine 22 : 1254-1258, 1997   DOI   ScienceOn
16 Roy-Camille R, Saillant G, Berteaux D, Salgado V : Osteosynthesis of thoraco-lumbar Spine fractures with metal plates screwed through the vertebral pedicles. Reconstr Surg Traumatol 15 : 2-16, 1976   PUBMED