• Title/Summary/Keyword: biological removal

Search Result 1,300, Processing Time 0.029 seconds

Degraded Paddy Soils. I. Theoretical Analysis on the Sultide Formation and the Effect of Iron Hydroxide Upon Removal of Sulfide from Solution

  • Cho, Chai-Moo
    • Applied Biological Chemistry
    • /
    • v.2
    • /
    • pp.9-14
    • /
    • 1961
  • The formation of sulfide from sulfate has been discussed from the thermodynamic principles. No mechanism of the reaction has been presented. From the stoichiometric and Nernst equations for the conversion of sulfate into sulfide, it was concluded that the formation of sulfide from sulfate can take place more readily if pH of a medium is low. The difficulty of this conversion increases with increasing pH. As pH of a medium increases, the degree of dissociation of H₂S into S= increases and this, in turn, renders the chance of precipitation of sulfide as FeS easier. Higher the pH of a soil or medium, greater is the S= concentration. The concentration of ferrous ion required to remove dissolved sulfide in a medium by forming insoluble FeS decreases with increasing pH. From the theory it was pointed out that an application of lime and iron rich foreign substances to a soil may be effective in causing the removal of dissolved sulfide from solution.

  • PDF

Verification of biological nitrogen removal model in anoxic-oxic process (무산소-산소 공정에서 생물학적 질소 제거 모델의 검증)

  • Lee Byung-Dae;Cheong Kung-Hoon
    • Journal of Environmental Science International
    • /
    • v.14 no.12
    • /
    • pp.1155-1161
    • /
    • 2005
  • Anoxic-oxic process were analyzed numerically for the each unit and final TN effluent by Water Quality Management(WQM) model and the results were compared data from these sewage or wastewater treatment plants. No bugs and logic error were occurred during simulation work. All of the simulation results tried to two times were obtained and both results were almost same thus this model has good reappearance. A few of simulation results were deviated with measured data because lack of influent water qualities are reported however simulation results have wholly good relationship with measured data. Also each unit of simulation result was kept good relationship with that of measured data therefore this WQM model has good reliance. Finally, WQM model predicts final TN effluent within ${\pm}4.1\;mg/{\ell}$

A Study on the Characteristics of Adsorption and Biodegradation of Organic Matter for the Media Selection in Biological Activated Carbon (생물활성탄의 여재선정을 위한 유기물의 흡착 및 생물분해 특성에 관한 연구)

  • 우달식
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.156-164
    • /
    • 1998
  • This study was performed to select media for the development of biological activated carbon process. Using activated carbon made by Norit, Calgon, Samchully Co., removal efficiency of humic acid by the isothermal adsorption test and biodegradation of organic matters by microbes attached to BAC and observation and counting of microbes attached to BAC were examined. The removal efficiency of humic acid with dose of activated carbon was influenced by initial concentration. Compared with other activated carbon, Norit was found to be most effective in view of adsorption capacity, biodegradation of organic matter, and attachment characteristics of microorganism. In conclusion, Norit which has high adsorption capacity and good biodegradation of organic matter was recommended for selecting media in BAC process.

  • PDF

Cleanup of Fluorene-Contaminated Soil by Continuous Chemical and Biological Treatment (화학적 및 생물학적 연속 처리에 의한 플루오렌 오염토양의 정화)

  • Lee, Byung-Dae
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.159-164
    • /
    • 2011
  • We describe a method for effectively pretreating soil highly that has been contaminated with fluorene (${\gg}$ 120 mg/kg soil), i.e., we apply Fenton oxidation in which ethanol is added to increase fluorene removal. To obtain maximum fluorene removal efficiency, a minimum of 1.0 ml of ethanol, 0.35 ml of $H_2O_2$, and 0.2 ml of 0.5M $Fe^{2+}$ was needed per 1 g of fluorene-contaminated soil. Under optimal Fenton oxidation conditions, 13% of 9-fluorene was generated during Fenton oxidation of 43% fluorene. The biodegradability of 9-fluorenone was subsequently confirmed to be much more rapid than that of fluorene, i.e., biodegradability of 96% versus 35% over 31 days. These results demonstrate that the proposed treatment method can be effectively applied to remove fluorene prior to disposal at industrial waste sites.

Tertiary Treatment of Municipal Wastewater and Bypassed Rainfall Treatment using by BAF (BAF를 이용한 하수의 3차 처리 및 by-pass된 우수의 처리)

  • Lee, Kwang Je;Park, Jae-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.327-331
    • /
    • 2005
  • The study was conducted with two laboratory biological aerated filter (BAF) reactors: denitrification filter (DF) and nitrification BAF. The influent flow (Q) was fixed to 48 L/d and total empty bed contact time (EBCT) was 1 hr. The flow direction was upflow with NRCY of 1 to 2Q. The secondary effluent was fed to the reactors and the influent concentrations were adjusted with some stock solutions to simulate by-pass concentration during rainfall. The study results indicate that COD and SS removal efficiencies were excellent and not influenced by temperature. Nitrification efficiency was over 90% at the influent loading less than $1.12kg/media\;m^3/d$, but the efficiencies were decreased in low temperature. TN removal efficiencies were 10% to 60%.

A study on the Treatment of Slaughterhouse Wastewater using Curtain Biological Film Contact Process. (커어튼형 생물막 접촉공법에 의한 도축장 폐수 처리에 관한 연구)

  • 이태호;은종극
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.14-19
    • /
    • 2000
  • This study was carried out to get efficient of nutrient removal and wastage sludge production minimized effects on the treatment of slaughterhouse wastewater using aerobic curtain biological film contact process. As a results of biofilm attachment experiment aggravation of water quality due to excessive biofilm showed after every 15 days of operating times. The concentration of BOD and COD in the influent were 2500~3000mg/L and 1700~2100mg/L , respectively. The average BOD and CoD were 9mg/L and 17mg/L , respectively. The result of this experiment was wastage sludge did not almost generated and the removal efficiency of nutrients were kept equilibrium.

  • PDF

A Study on Biological Treatment of Nitrogen and Phosphorus (생물학적 질소 및 인 제거에 관한 연구)

  • 이현동;유형열;김원만
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.1
    • /
    • pp.45-56
    • /
    • 1992
  • The Anaerbic Anoxic/oxic process is one of the biological treatment methods to remove nitrogen and phosphorus effectively which are nutritional elements for eutrophication. Supernatant of primary sediment of Anaerobic digester is used as a carbon source instead of methanol methanol supply in usual A$_{2}$/O process. The efficiency of the following treatment processes are as follow : 1) Changing recycle ratio in the usual A$_{2}$/O process without the stage of Anaerobic digester. 2) Changing recycle ratio in the usual A$_{2}$/O process with the supernatant supply of the Anaerobic digester. In the result of comparison, changing recycle ratio is almost no effect in the removal of phosphorus, however the effect of removal in nitrogenous substance are remarkable, and the effect of Anaerobic digester is not as effective as expected because the BOD removed in the digester partly, the rate of phosphorus to the BOD exceed pertinent range.

  • PDF

Design of Passive Treatment Systems for Mine Drainage Waters

  • Jeen, Sung-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.2
    • /
    • pp.1-9
    • /
    • 2017
  • Passive treatment systems are commonly used for remediation of mine drainage waters because they do not require continuous chemical inputs and operation. In this study, the selection and design criteria for such systems were evaluated, particularly the two most commonly used ones, i.e., permeable reactive barriers (PRBs) and vertical flow biological reactors (VFBRs). PRBs and VFBRs are operated on the same principles in terms of biochemical reaction mechanisms, whereas differences relate to configuration, engineering, and water management. In this study, each of these systems were described with respect to key design variables, such as metal removal mechanisms and removal rates, effectiveness and longevity, general design and construction, flow capacity, and cost. The information provided from this study could be used as a design guideline when a passive treatment option is considered for potential remediation of a mine site.

Studies on the Biological Treatment of Dye Waste Water and Degration of Polyvinyl Alcohol (염색공장 폐수중 PVA 분해세균의 분리 및 생물학적 처리효과)

  • 강선태;서승교;권오억
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.1
    • /
    • pp.21-28
    • /
    • 1990
  • As a research for treatment of waste water by biological method, we investigated general characteristics of waste water and isolated some useful bacteria which effectively treated waste water. Compositions of waste water were analyzed to give COD 2060 ppm, PVA 560 ppm, T-N 50 ppm, T-P 3.3 ppm and PH 12. Also, we inverstigated optimum nutrients requirement and growth conditions by mixed culture as well as the effect of coagulants. The COD removal rate reached maximum state for 48 hrs culture at pH 7.0 and 30$^{\circ}$C. Alum as the coagulated was the most effective. The COD removal rate was also increased by supplementing 10 ppm phosphorous sources as additional nutrients. The COD of waste water was reduced to 10% of its initial value by the continuous culture. As a result of overall experiments the COD of effluents became about 100 ppm and final pH 7.

  • PDF

Treatment of Dyeing Wastewater by Magnetic-Biological Treatment System (자화-생물처리 시스템에 의한 염색폐수의 처리)

  • Lee, Seon-Ha
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.371-377
    • /
    • 2010
  • The purpose of this study is to investigate treatment efficiency in dyeing wastewater treatment by the high rate aeration system(HRA) and a combination of the HRA with magnetized wastewater treatment system(MWS). At the hydraulic retention time of 16hr, 24hr, 30hr, BOD removal efficiencies of HRA system were 93%, 96% and 98%, combination of the HRA with MWS system were 94%, 96.8% and 98.2%, respectively. In ease of COD, at the hydraulic retention time of 16hr, 24hr, 30hr, COD removal efficiencies of HRA system were 66%, 77.1% and 83.1%, combination of the HRA with MWS system were 70.2%, 80.1% and 86.6%, respectively. The comparison of the HRA and combination of the HRA with MWS, effluent BOD of the former was 22.7mg/${\ell}$ and the latter was 19.4mg/${\ell}$, theretore biological treatment efficiency identified to increase by the MWS.