• Title/Summary/Keyword: bioimpedance

Search Result 50, Processing Time 0.026 seconds

Early Detection of Peripheral Intravenous Infiltration Using Segmental Bioelectrical Impedance: Preliminary Study

  • Kim, Jaehyung;Jeong, Ihnsook;Baik, Seungwan;Jeon, Gyerok
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.3
    • /
    • pp.482-490
    • /
    • 2017
  • Early detection of infiltration is one of the most important tasks of nurses to minimize skin damage due to infiltration. For subjects receiving invasive intravenous treatment, the bioelectrical impedance (impedance) were measured in the frequency range of 5 to 500 kHz using bioelectrical impedance spectroscopy (BIS). After attaching electrodes at both ends of a transparent dressing mounted on the skin in which IV solution was infused into the vein, the change in impedance was measured as a function of time and frequency before and after infiltration. The experimental results are described as follows. When IV solution was properly infused into the vein, the impedance was nearly constant over time and decreased with increasing frequency. However, when infiltration occurred, the impedance decreased significantly and thereafter gradually decreased with time. In addition, impedance decreased with time for all applied frequencies. In this study, when IV solution penetrated into the surrounding skin and subcutaneous tissue by infiltration, impedance was quantitatively analyzed for as a function of time and frequency. This suggests a method for early detection of infiltration using BIS.

A Human Arm Movement Detection System Using Electrical Bioimpedance Measurement (생체 임픽던스 측정에 의한 상지 운동 감지 시스템)

  • Kim, Jong-Chan;Kim, Su-Chan;Nam, Gi-Chang;Park, Min-Yong;Kim, Gyeong-Hwan;Kim, Deok-Won
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.8
    • /
    • pp.374-379
    • /
    • 2002
  • In this study, we developed a new human arm movement detection system using electrical bio-impedance method with several skin-electrodes. The correlation coefficients of the joint angle and the impedance change from human arm movement was obtained using a goniometer and impedance measurement system developed in this study. The correlation coefficients of the wrist and the elbow movements were 0.94 and -0.99, respectively. This system was applied to control a robotic arm by converting the measured impedance to joint angle to confirm the validity of the proposed system. In conclusion, we confirmed that this system can control the robotic arm according to arm movement without any limitation of movement. This system showed possibility that upper arm movement could be easily measured by impedance measurement system with a few skin-electrodes.

Radial Electrical Impedance: A Potential Indicator for Noninvasive Cuffless Blood Pressure Measurement

  • Huynh, Toan Huu;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.239-244
    • /
    • 2017
  • Noninvasive, cuffless, and continuous blood pressure (BP) monitoring is essential to prevent and control hypertension. A well-known existing method for this measurement is pulse transit time (PTT), which has been investigated by many researchers as a promising approach. However, the fundamental principle of the PTT method is based on the time interval taken by a pulse wave to propagate between the proximal and distal arterial sites. Consequently, this method needs an independent system with two devices placed at two different sites, which is a problem. Even though some studies attempted to synchronize the system, it is bulky and inconvenient by contemporary standards. To find a more sensitive method to be used in a BP measurement device, this study used radial electrical bioimpedance (REB) as a potential indicator for BP determination. Only one impedance plethysmography channel at the wrist is performed for demonstrating a ubiquitous BP wearable device. The experiment was evaluated on eight healthy subjects with the ambulatory BP monitor on the upper arm as a reference. The results demonstrated the potential of the proposed method by the correlation of estimated systolic (SBP) and diastolic (DBP) BP against the reference at $0.84{\pm}0.05$ and $0.83{\pm}0.05$, respectively. REB also tracked the DBP well with a root-mean-squared-error of $7.5{\pm}1.35mmHg$.

SPECTROSCOPIC ADMITTIVITY IMAGING OF BIOLOGICAL TISSUES: CHALLENGES AND FUTURE DIRECTIONS

  • Zhang, Tingting;Bera, Tushar Kanti;Woo, Eung Je;Seo, Jin Keun
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.18 no.2
    • /
    • pp.77-105
    • /
    • 2014
  • Medical imaging techniques have evolved to expand our ability to visualize new contrast information of electrical, optical, and mechanical properties of tissues in the human body using noninvasive measurement methods. In particular, electrical tissue property imaging techniques have received considerable attention for the last few decades since electrical properties of biological tissues and organs change with their physiological functions and pathological states. We can express the electrical tissue properties as the frequency-dependent admittivity, which can be measured in a macroscopic scale by assessing the relation between the time-harmonic electric field and current density. The main issue is to reconstruct spectroscopic admittivity images from 10 Hz to 1 MHz, for example, with reasonably high spatial and temporal resolutions. It requires a solution of a nonlinear inverse problem involving Maxwell's equations. To solve the inverse problem with practical significance, we need deep knowledge on its mathematical formulation of underlying physical phenomena, implementation of image reconstruction algorithms, and practical limitations associated with the measurement sensitivity, specificity, noise, and data acquisition time. This paper discusses a number of issues in electrical tissue property imaging modalities and their future directions.

Study on Consequent Nutrient Intake Status , Body Mass Index , and Fat Distribution after Silk Amino Peptide and Dietary Fiber Supplementation (식이 섬유소 및 실크 펩타이드 보충이 영양소 섭취상태 , 체적지수 및 복부 비만에 미치는 영향에 관한 연구)

  • Lee, Seong-Hui;Choe, Ae-Jin;Song, Su-Jin;Ryu, Jeong-Min;No, Suk-Ryeong;Hwang, Yeong-Hui
    • Journal of the Korean Dietetic Association
    • /
    • v.8 no.2
    • /
    • pp.175-184
    • /
    • 2002
  • This study is to investigate consequent nutrient intake status, influence of body mass index(BMI), and fat distribution on the silk amino peptide(SAP) and dietary fiber supplementation. During 2 months of this research (January to March, 2002), 45 women aged 20yr – 30yr (average age 24.6yr) were selected as subjects. Nutrient intake was investigated by questionnaire, 24-hr recall method. Antropometric assessments of the subjects were investigated by SBIA method(Segmental bioimpedance assay, In body 3.0). The results are as follows: mean body weight 57.7kg, mean body height 161.9cm mean BMI 22.0, and mean food habit score was 8.47. Defecation frequency was increased by dietary fiber supplementation. Frequency of pain during defecation was significantly decreased by dietary fiber supplementation (p<0.01). Feeling of residual feces was significantly improved by dietary fiber supplementation(p<0.001). Status of energy and carbohydrate intakes significantly decreased after dietary fiber supplementation(P<0.05). Body fat and WHR(waist hip ratio) significantly decreased after dietary fiber supplementation(P<0.001), and percent body fat was decreased by dietary fiber supplementation, significantly(P<0.05). Above results of this study show that dietary fiber-added routine diet improves defecation condition, and lessens body fat, percent body fat without losing body muscle. Especially, declination of abdominal fat and WHR were notable. That meant decreased risk factor.

  • PDF

Factors influencing the bio-impedance data in tissue segments along the three arm meridians: a pilot study

  • Lim, Chi Eung Danforn;Wong, Felix Wu Shun;Smith, Warren
    • CELLMED
    • /
    • v.1 no.1
    • /
    • pp.7.1-7.9
    • /
    • 2011
  • Bioelectric impedance measurements have been reported to show significant variation between individuals. Different physiological conditions like thickened skin, obesity, and fluid retention can affect the impedance measurement. Therefore, it is important to learn what other factors can affect the measurements of impedance even in healthy individuals. Such information is a prerequisite for understanding the changes in impedance associated with acupuncture treatment. This study investigated the bio-impedance properties of tissue segments in the arms of a number of healthy subjects, so as to define the factors that might influence the variation of the bio-impedance data in acupuncture meridians studies. 51 healthy subjects were recruited through Liverpool Hospital, Sydney. Demographic data was collected from each subject including the age, sex, BMI, and time since most recent meal. Electrodes were applied to the forearms of each test subject. Measurements were done by a purpose-built Bio-Impedance Research Device (BIRD-I) which allowed the determination of core resistance (Rc) and core reactance (Xc) of each of the three meridian tissue segments on the anterior surface of the forearm. No significant difference was found in the core resistance attributable to age group, gender, BMI or meal intake. However, a statistically significant trend in increasing resistance from the radial to ulnar aspect of the forearm (p < 0.001) was found. No significant difference was found in the core resistance of test tissue segments among the 51 healthy subjects measured in this study. However, the trend of increasing core resistance from the radial to ulnar aspects of the arm deserves further investigation.

Comparisons of obesity assessments in over-weight elementary students using anthropometry, BIA, CT and DEXA

  • Yu, Ok-Kyeong;Rhee, Yang-Keun;Park, Tae-Sun;Cha, Youn-Soo
    • Nutrition Research and Practice
    • /
    • v.4 no.2
    • /
    • pp.128-135
    • /
    • 2010
  • Obesity was characterized in Korean elementary students using different obesity assessment tests on 103 overweight elementary students from three schools of Jeonbuk Province. The body mass index (BMI) and obesity index (OI) were compared, and the data using DEXA and CT were compared with the data using BIA and a tape measure. The results of this study are as follows: first, 27 students who were classified as obese by OI were classified as overweight by BMI, and 3 students who were classified as standard weight by BMI were classified as overweight by OI. Secondly, by DEXA and BIA measurements, there was 1.51% difference in body fat percentage (boys 1.66%, girls 1.17%) and the difference in body fat mass between boys and girls was 0.77 kg (boys 0.85 kg, girls 0.59 kg), but those differences in body fat percentage and mass were not statistically significant. Thirdly, the average total abdominal fat (TAF) measured by CT scans of obese children was more significantly related with subcutaneous fat (r = 0.983, P < 0.01) than visceral fat (r = 0.640, P < 0.01). Also, TAF were highest significant with waist circumference by a tape measure (r = 0.744, P < 0.01). In summary, as there are some differences of assessment results between two obesity test methods (BMI, OI), we need more definite standards to determine the degree of obesity. The BIA seems to be the most simple and effective way to measure body fat mass, whereas waist/hip ratio (WHR) using a tape measurer is considered to be the most effective method for assessing abdominal fat in elementary students.

Onion peel extract reduces the percentage of body fat in overweight and obese subjects: a 12-week, randomized, double-blind, placebo-controlled study

  • Lee, Ji-Sook;Cha, Yong-Jun;Lee, Kyung-Hea;Yim, Jung-Eun
    • Nutrition Research and Practice
    • /
    • v.10 no.2
    • /
    • pp.175-181
    • /
    • 2016
  • BACKGROUND/OBJECTIVES: The anti-obesity effect of quercetin-rich onion peel extract (OPE) was suggested in rats, but information from human studies is limited. This study aimed to investigate the effects of OPE on the body composition of overweight and obese subjects. MATERIALS/METHODS: In this 12-week, randomized, double-blind, placebo-controlled study, parallel clinical trials were performed in overweight and obese Korean subjects. Randomly assigned subjects were instructed to take daily either the placebo (male, 6 and female, 30) or OPE capsules containing 100 mg of quercetin (male, 5 and female, 31). Body composition was measured by using bioimpedance and dual-energy X-ray absorptiometry (DXA). Resting energy expenditure (REE) and respiratory quotient (RQ) were evaluated by using indirect calorie measurement methods. Fasting blood levels of glucose, insulin, lipids, and leptin were determined. RESULTS: Quercetin-rich OPE supplementation significantly reduced the weight and percentage of body fat as measured by DXA (P = 0.02). These effects were not shown in the control group. Levels of blood glucose (P = 0.04) and leptin (P = 0.001 for placebo, P = 0.002 for OPE) decreased in both groups. Significant increases in REE and RQ were observed in both groups (P = 0.003 for placebo, P = 0.006 for OPE) and in the OPE group alone (P = 0.02), respectively. CONCLUSIONS: Quercetin-rich OPE supplementation changed the body composition of the overweight and obese subjects. This result suggests a beneficial role of the anti-obesity effect of OPE human subjects.

Factors Associated with Changes in Bone Mineral Content among Girls in Early Pubertal Age (사춘기 초기 여자 어린이의 골질량 변화와 이에 영향을 미치는 요인 분석)

  • Yun, So-Yoon;Park, Min-Kyoung;Paik, Hee-Young;Joung, Hyo-Jee
    • Journal of Nutrition and Health
    • /
    • v.40 no.1
    • /
    • pp.69-77
    • /
    • 2007
  • The study was conducted to investigate the factors associated with bone mineral content (BMC) changes among early pubertal aged girls. Two hundred and thirty girls between 9 to 11 years of age participated in (our surveys over 2 year period. During each survey, dietary intakes were collected with 3-day food records, BMC of left leg's calcaneus were measured by PIXI (Lunar Ltd.) and body composition was measured by bioimpedance method (Inbody 3.0 Biospace Co. Ltd, Seoul, Korea). Mean values of BMC increased in consecutive measurements -1.48 g, 1.54 g, 1.61 g and 1.66 g. The change of BMC between the first and last measurements was significantly positively correlated with % body fat, negatively correlated with BMC at the baseline (p < 0.05). Change of BMC was also significantly positively correlated with % change of lean mass and mineral mass between the first and last measurements. Nutrient intakes during the study period were calculated as mean daily intakes from all surveys. Mean daily intakes of Vit. C and Vit. $B_6$ were positively and isoflavone intake was negatively correlated with changes of BMC (p < 0.05). In stepwise regression of BMC change with body composition and nutrient intakes, baseline values of BMC, weight, BMI and age, % change of mineral mass during the study period, mean intakes of isoflavone, Vit. $B_6$, protein, carotene and zinc were significant explanatory variables ($R^2=0.38$, p <.001, F = 32.39). The results imply that the change of BMC among early pubertal aged girls are associated with some body composition and intakes of certain nutrients.

A Study on the Characteristics of Four Electrode Bioimpedance Model using Dry Electrode (건식전극을 이용한 4 전극형 생체임피던스 모델 특성 연구)

  • Cho, Young Chang;Jeong, Jong Hyeong;Yun, Jeong-oh;Kim, Min Soo
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1122-1127
    • /
    • 2019
  • In this study, the bio-impedance of the human body is able to obtain a lot of information by monitoring the pathological and physiological conditions of clinical and biological tissues. The four electrode method system for biometrics measured the potential difference between two electrodes and the other two electrodes were used as electrodes for current flow. The newly developed dry gold electrode measured impedance from 1 Hz to 50 kHz and produced reproducible results. To verify the impedance measurement of the dry electrode, the pitting was performed using an equivalent circuit model of the bioelectrode skin, and the effectiveness was demonstrated through modeling. Fixed electrode types have a constant position of the electrodes attached during the measurement, so that a stable measurement can be obtained, thereby minimizing the error.