• 제목/요약/키워드: biogas

검색결과 474건 처리시간 0.028초

Entomological approach to the impact of ionophore-feed additives on greenhouse gas emissions from pasture land in cattle

  • Takahashi, Junichi;Iwasa, Mitsuhiro
    • Journal of Animal Science and Technology
    • /
    • 제63권1호
    • /
    • pp.16-24
    • /
    • 2021
  • The suppressive effect of monensin as an ionophore-feed additive on enteric methane (CH4) emission and renewable methanogenesis were evaluated. To clarify the suppressive effect of monensin a respiratory trial with head cage was performed using Holstein-Friesian steers. Steers were offered high concentrate diets (80% concentrate and 20% hay) ad libitum with or without monensin, galacto-oligosaccharides (GOS) or L-cysteine. Steers that received monensin containing diet had significantly (p < 0.01) lower enteric CH4 emissions as well as those that received GOS containing diet (p < 0.05) compared to steers fed control diets. Thermophilic digesters at 55℃ that received manure from steers fed on monensin diets had a delay in the initial CH4 production. Monensin is a strong inhibitor of enteric methanogenesis, but has a negative impact on biogas energy production at short retention times. Effects of the activity of coprophagous insects on CH4 and nitrous oxide (N2O) emissions from cattle dung pats were assessed in anaerobic in vitro continuous gas quantification system modified to aerobic quantification device. The CH4 emission from dungs with adults of Caccobius jessoensis Harold (dung beetle) and the larvae of the fly Neomyia cornicina (Fabricius) were compared with that from control dung without insect. The cumulative CH4 emission rate from dung with dung insects decreased at 42.2% in dung beetles and 77.8% in fly larvae compared to that from control dung without insects. However, the cumulative N2O emission rate increased 23.4% in dung beetles even though it reduced 88.6% in fly larvae compared to dung without coprophagous insects. It was suggested that the antibacterial efficacy of ionophores supplemented as a growth promoter still continued even in the digested slurry, consequently, possible environmental contamination with the antibiotics might be active to put the negative impact to land ecosystem involved in greenhouse gas mitigation when the digested slurry was applied to the fields as liquid manure.

소화탈리액 대상 오존 전처리와 Ultra Violet-Advanced Oxidation Process 연계 처리를 통한 유기물질 지표 개선 (Improvement of Organic Substances Indicators by Linked Ultra Violet-Advanced Oxidation Process After Ozonation for Anaerobic Digested Wastewater)

  • 이재엽;제스민아터;김일호
    • 상하수도학회지
    • /
    • 제37권5호
    • /
    • pp.253-259
    • /
    • 2023
  • Bioreactors are devices used by sewage treatment plants to process sewage and which produce active sludge, and sediments separated by solid-liquid are treated in anaerobic digestion tanks. In anaerobic digestion tanks, the volume of active sludge deposits is reduced and biogas is produced. After dehydrating the digestive sludge generated after anaerobic digestion, anaerobic digested wastewater, which features a high concentration of organic matters, is generated. In this study, the decomposition of organic carbon and nitrogen was studied by advanced oxidation process. Ozone-microbubble flotation process was used for oxidation pretreatment. During ozonation, the TOC decreased by 11.6%. After ozone treatment, the TOC decreased and the removal rate reached 80.4% as a result of the Ultra Violet-Advanced Oxidation Process (UV-AOP). The results with regard to organic substances before and after treatment differed depending on the organic carbon index, such as CODMn, CODCr, and TOC. Those indexes did not change significantly in ozone treatment, but decreased significantly after the UV-AOP process as the linkage treatment, and were removed by up to 39.1%, 15.2%, and 80.4%, respectively. It was confirmed that biodegradability was improved according to the ratio of CODMn to TOC. As for the nitrogen component, the ammonia nitrogen component showed a level of 3.2×102 mg/L or more, and the content was maintained at 80% even after treatment. Since most of the contaminants are removed from the treated water and its transparency is high, this water can be utilized as a resource that contains high concentrations of nitrogen.

양돈슬러리를 이용한 혐기소화에서 미생물 첨가가 메탄발생에 미치는 영향 (Effects of Supplementation of Mixed Methanogens and Rumen Cellulolytic Bacteria on Biochemical Methane Potential with Pig Slurry)

  • 김지애;윤영만;정광화;김창현
    • 한국토양비료학회지
    • /
    • 제45권6호
    • /
    • pp.1049-1057
    • /
    • 2012
  • 본 연구는 메탄생성에 직접적으로 관여하는 혼합 메탄균과 셀롤로스 등의 고분자 물질의 가수분해 반응에 활성이 뛰어난 반추위 내 혐기성 섬유소분해균 중에서 대표적인 Fibrobacter succinogenes, Ruminococcus flavefaciens 및 Ruminococcus albus를 biochemical methane potential (BMP) 시험에 첨가하였을 때 메탄 발생에 미치는 영향을 조사하고자 수행되었다. BMP시험은 멸균증류수를 첨가한 control과 각각의 미생물 배양액을 첨가한 혼합 메탄균 첨가구 (M), F. succinogenes 첨가구 (FS) R. flavefaciens 첨가구 (RF), R. albus 첨가구 (RA) 및 RA+FS 혼합첨가구와 M+RA+FS 혼합 첨가구로 총 7개 처리구로 각 처리구별 3반복으로 진행되었다. 미생물 배양액의 첨가량은 식종액과 양돈슬러리에 1% (0.5 mL), 3% (1.5 mL) 및 5% (2.5 mL) 씩 첨가 하였다. BMP 시험을 위해 60일간 배양이 지속되었고 중온소화를 위해 $38^{\circ}C$의 배양기에서 수행되었다. 실험의 결과 총 바이오가스 발생량은 5% RF와 RA+FS가 대조구에 비하여 8.1 및 8.4%로 가스발생량이 유의적으로 높았다(p<0.05). 메탄발생량은 3% 미생물 배양액 첨가구 중 M+RA+FS를 제외하고 대조구에 비하여 증가시키는 경향을 보였으며, 5% 배양액을 첨가하였을 때는 대조구에 대하여 5%의 M, FS, RF, RA, RA+FS, 및 M+RA+FS RF가 각각 12.1, 12.6, 17.3, 13.7, 17.9 및 14.7%로 메탄가스발생량을 증가시켰다 (p<0.05). TS 및 VS 분해율은 가스발생량과는 관계없이 모든 처리구에서 미생물 배양액의 첨가량이 증가하더라도 차이가 없었다. BMP 종료시 배양액내 pH는 모든 처리구가 7.527~7.657의 범위로 메탄발효에 큰 영향을 주지 않았다. 결론적으로, 본 실험에서는 양돈 슬러리의 성분특성으로 인해 가수분해단계와 메탄생성단계 모두에 첨가한 미생물 배양액이 효과가 있었으나, 5% 첨가수준을 제외하고 낮은 첨가수준에서는 첨가효과가 나타나지는 않았다.

생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구 (Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems)

  • 김윤기;고재균
    • 한국농공학회지
    • /
    • 제22권1호
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

막결합형 2상 혐기성 소화 공정을 이용한 음식물 탈리액 처리 (Treatment of Garbage Leachate with Two-phase Anaerobic Digestion Coupled with Ultra Filtration)

  • 이은영;김형국;티투이장;배재호;배영신;원종철;이재훈;박성균;조용완
    • 대한환경공학회지
    • /
    • 제31권11호
    • /
    • pp.997-1006
    • /
    • 2009
  • 본 연구에서는 음폐수를 대상으로 5 톤/일 처리규모의 막결합형 2상 혐기성 소화(TPADUF) 플랜트를 운영하며 유기물 제거효율 및 메탄 발생량을 파악하고, 소화가스를 이용한 발전 가능성 및 분리막 적정 운영방안을 검토하였다. 고온 산발효조, 중온 메탄조 및 UF 막으로 구성된 처리 시스템에서 평균 TCOD가 150 g/L인 음폐수를 유기물 부하 11.1 g COD/L/d까지 증가시키며 처리한 결과 최종 유출수의 TCOD는 6 g/L 이하이었으며, TCOD 및 SCOD 제거효율은 모두 95% 이상이었다. 소화 가스의 메탄 구성비는 65%이었으며, 회수된 메탄량은 시스템에서 일부 가스가 누출되었음에도 39 $m^3/m^3$ 음폐수 주입량, 260 $m^3$/톤 COD유입량, 또는 270 $m^3$/톤 COD제거량 이었다. 소모된 가스량 당 발전량은 0.96 kWh/$m^3$ 가스, 또는 1.49 kWh/$m^3$ 메탄으로 다소 낮았으나 이는 소용량 발전기(15 kW급)의 저효율에 기인한 것이다. 분리막은 평균 flux 10 L/$m^2$/hr에서 운전하였으며, 운전 중 flux가 감소하였을 때는 물 또는 화학적(NaOCl)세정을 실시하여 회복시킬 수 있었다. TPADUF 플랜트에서는 메탄조 내액 또는 분리막 농축액을 산발효조로 반송함으로써 산발효조의 pH를 별도의 약품 주입 없이 적정 수준을 유지할 수 있었으며, 산발효조에서 부분적인 메탄생성을 통해 메탄조의 유기물 부하를 낮추는 효과도 있었다.

폴리설폰 중공사막 모듈을 이용한 자동차 연료용 고순도 바이오메탄 분리공정 연구 (Membrane Process Using Polysulfone Hollow Fiber Membranes for Vehicle Fuel Production from Bio-Methane Mixture)

  • 김지상;공창인;박보령;김정훈
    • 멤브레인
    • /
    • 제24권3호
    • /
    • pp.213-222
    • /
    • 2014
  • 자동차 연료용 바이오가스의 고순도 메탄 분리정제를 위해 2단 재순환 분리막 공정을 연구하였다. 2단 재순환 분리막 공정을 개발하기 위해 폴리설폰(Polysulfone) 중공사 모듈을 채택하여 이산화탄소, 메탄의 순수투과도를 측정하였다. 또한 모델 혼합가스를 대상으로 모듈의 메탄농도와 압력에 대해 투과실험을 수행하여 메탄의 농도와 회수율에 대한 연구를 수행하였다. 그 결과를 토대로 2단 재순환 분리막 파일럿 플랜트를 제작하였으며 현장에서 발생되는 바이오가스를 대상으로 공정변수에 대한 메탄 회수율과 농도에 관한 투과실험을 수행하였다. 제습기와 탈황설비 등의 전처리설비를 거쳐 가스 내의 수분을 500 ppm 이하, 바이오가스내의 황화수소 농도를 20 ppm 이하로 제거하였으며 그 정제된 혼합가스를 대상으로 파일럿 분리막 공정의 막면적비에 따른 운전결과를 알아보기 위하여 1, 2단의 막면적비가 각각 1:1, 1:3, 2:2가 되도록 구성하여 실험을 진행한 결과, 1단의 막면적은 $1m^2$로 동일하고 2단의 면적비가 $1m^2$에서 $3m^2$로 증가하였을 경우 최종 공급유량은 6.6 L/min에서 80.7 L/min로 그리고 메탄 회수율은 메탄순도 95%에서 47.1%에서 92.5%로 증가하였다. 또한, 막 면적비가 1:1로 동일한 경우 전체 면적이 2배로 증가함에 따라서 유량은 6.6 L/min에서 100.8 L/min로 회수율은 47.1에서 88.3%를 나타내었다. 1:3 면적비에서 공급유량이 증가하는 경우, 최종 메탄 순도는 감소하고 메탄 회수율은 증가하는 것을 알 수 있었다. 운전압력이 증가할수록 공급유량은 증가하고 회수율은 다소 감소하는 것으로 나타났다. 실험을 통해 유효막면적, 공급압력과 공급유량의 변화가 공정 성능향상에 중요한 영향을 미친다는 것을 확인하였다.

혐기소화공정에서 항생항균물질이 메탄생성에 미치는 영향 (Effects of Antimicrobials on Methane Production in an Anaerobic Digestion Process)

  • 오승용;박노백;박우균;천만영;권순익
    • 한국환경농학회지
    • /
    • 제30권3호
    • /
    • pp.295-303
    • /
    • 2011
  • 혐기성 소화 반응조에서 항생항균물질의 영향을 평가하기 위해서 회분식 및 연속식 실험을 통하여 biogas 발생량, 유기산 생성, 유기물 제거 거동 등을 관찰하였다. 회분식 조건에서 단일항생항균물질 1~10 mg/L에서는 저해 영향이 관찰되지 않았으며, 50 mg/L에서 일부 VFAs가 축적되었고 16~30%의 유기물 제거효율이 감소되었지만, 일시적 저해 영향 후 점차 안정되었다. 그러나 항생항균물질 100 mg/L에서 바이오가스 발생량이 48~58% 감소하였으며, VFAs가 메탄으로 전환되지 않고 축적되었다. 연속식 반응기에서 4종의 혼합항생항균물질을 1~10 mg/L 주입시 미생물에 대한 저해영향은 없었으며, 50 mg/L 주입시 30~40%의 메탄가스 발생량이 감소하였고, 이는 이론적 메탄발생량의 60~65% 수준이었다. 항생항균물질 100 mg/L 주입시 85% 감소한 약 2.2 L/day의 바이오가스가 발생하였으며, 서서히 회복하여 7.2 L/day까지 바이오가스가 발생하였으나 대조군 대비 52% 수준이상은 회복되지 않았다. 항생항균물질 50 mg/L에서는 독성 저해 후 반응조 체류시간의 3배인 약 30일 정도 후 유기물 제거효율 및 바이오가스 회수가 가능하였으나, 100 mg/L 주입 후 40일 후에도 유기물 제거효율 및 바이오가스 발생량은 낮은 수준이었다. 따라서 혐기성 소화조에 고농도 항생항균물질이 유입되어 저해영향이 관찰되었을 경우 소화슬러지의 일부 또는 전체를 교체해야 할 것으로 판단된다. 혼합항생항균물질을 10~100 mg/L까지 주입하였을 경우 잔류항생항균물질 농도는 주입 6시간 후 CTC 80~90%, OTC 50~70%, SMZ 80~90%, TLS 20~40%가 반응조내에서 독성으로 작용한 후 입자성 유기물이나 EPS 등에 흡착되거나 소화온도에 의하여 감소한 것으로 판단된다. 따라서 혐기성 처리를 이용한 공정에 고농도 항생항균물질이 포함된 유기성폐수가 유입되었을 경우 공정의 유지관리에 어려움을 줄 수 있으며, 혐기소화조 유출수내 잔류항생항 균물질이 자연수계로 유입될 경우 2차 오염을 야기할 수 있기 때문에 항생항균물질의 사용의 적절한 관리가 요구되어 진다.

유기성폐자원에너지 인센티브제도 도입방안 연구(I): 바이오가스화 정밀모니터링 (A study on the introduction of organic waste-to-energy incentive system(I): Precise monitoring of biogasification)

  • 권준화;문희성;이원석;이동진
    • 유기물자원화
    • /
    • 제29권4호
    • /
    • pp.67-76
    • /
    • 2021
  • 바이오가스화는 유기성폐기물을 안정적으로 분해하여 처리하는 과정에서 발생하는 메탄(CH4)가스를 이용해 환경친화적인 연료를 생산하는 기술이다. 바이오가스화는 수분함량이 높은 유기성폐기물의 에너지화에 가장 많이 활용되는 방법이며, 직매립(2005) 및 해양투기(2013) 등의 금지에 따른 유기성폐기물 처리에 유용한 공법이다. 최근 국내에서 발병한 아프리카돼지열병(ASF, African Swine Fever)으로 습식사료화 재활용이 금지되고, 건조 사료화 및 퇴비화 등의 생산제품 수요처가 부정적으로 인식되면서 음식물류폐기물의 처리에 어려움을 겪고 있다. 이에, 음식물류폐기물의 처리 및 자원화를 위해 바이오가스화가 더욱 주목받고 있다. 우리나라 에너지소비 규모는 268.41 106toe에 이르며 세계 9위 수준이다. 하지만 공급에너지의 약 95.8 %를 해외수입에 의존하고 있는 에너지 빈곤 국가이다. 따라서 국내에서는 신·재생에너지 공급의무화제도(RPS, Renewable energy portfolio standard)를 도입하고 있다. 국내의 RPS 제도는 다른 신재생에너지와 비교하여 폐기물에너지의 신·재생에너지 공급인증서(REC, Renewable energy certificate)의 가중치를 낮게 설정하고 있다. 따라서 폐자원에너지의 활성화를 위한 추가적 인센티브 제도가 요구된다. 본 연구에서는 음식물류폐기물, 음폐수 및 다양한 유기성폐기물이 처리되는 혐기소화조의 운영방식을 알아보고, 일정 기간의 정밀모니터링을 통해 폐자원에너지 인센티브제도를 마련하는 기초자료로써 활용하고자 하였다. 유기성 폐기물로 바이오가스를 생산하여 발전과 중질가스로 활용하는 4개소를 대상시설로 선정하였고, 현장조사 및 시료채취를 실시하였다. 채취된 유기성폐기물의 유입물 시료와 처리공정에 따른 유출물 시료의 기초 성상분석을 수행하였다. 성상분석 결과, 소화조 유입물의 총 고형물은 평 균 12.11 %이며, 총 고형물 중 휘발성 고형물은 85.86 %로 확인되었다. BOD와 CODcr 제거율은 소화조의 유입·유출 대비 각각 60.8 %와 64.8 %로 나타났으며, 유입물의 휘발성지방산은 평균 55,716 mg/L로 나타났으며, 혐기소화 후 감소율이 평균 92.3 %로 대부분 분해되어 제거된 것을 확인할 수 있다.

폐기물처리시설의 세부검사방법 마련연구(I): 공정별 주요인자 도출 및 물질·에너지수지 산정 (A study on inspection methods for waste treatment facilities(I): Derivation of impact factor and mass·energy balance in waste treatment facilities)

  • 이풀잎;권은혜;손준익;강준구;전태완;이동진
    • 유기물자원화
    • /
    • 제31권1호
    • /
    • pp.69-84
    • /
    • 2023
  • 폐기물처리시설의 지속적인 설치·정기검사에도 불구하고 현장 처리시설에서는 과다소각, 불법투기 악취 등에 대한 민원이 지속적으로 발생하는 것으로 보아 현재의 폐기물처리시설 설치정기 검사방법의 개선이 필요하다고 판단되었다 이에 현재 운영중인 폐기물처리시설(6개분야)을 대상으로 현장조사를 실시하여 각 분야별 폐기물처리공정을 파악하고 검사에 적용된 주요한 운영인자를 파악하고, 주요공정별 물질·에너지수지를 산정하여 폐기물처리시설의 적정 운영 여부를 확인하였다. 주요 운영인자 조사 결과 소각 및 시멘트 소성로, 소각열회수시설 등의 경우 소각에 필요한 소각로의 온도 유지 및 발생되는 대기오염물질의 처리가 가장 주요한 인자였으며, 매립시설의 경우 옹벽의 안정성, 매립 후 발생되는 침출수 및 배출가스 관리가 주요한 인자로 나타났다. 멸균·분쇄시설의 경우 멸균여부(아포균검사)가 가장 중요한 주요인자 이었으며, 음식물류폐기물처리시설의 경우 발효(소화, 부숙) 시 체류시간 및 악취관리가 주요한 인자로 나타났다. 또한 물질에너지수지 산정 결과 소각시설의 경우 폐기물 투입량 대비 바닥재 발생량은 약 14%, 비산재 발생량은 약 3%로 적정 운영되고 있을을 확인하였다. 또한 음식물류폐기물시설 중 혐기성분해시설의 경우 유입량 대비 바이오가스 발생량은 약 17%, 바이오가스 전환효율은 약 81%로 나타났고, 퇴비화시설의 경우 유입폐기물 대비 약 11%의 퇴비가 생산되어 모두 적정운영 되고있음을 확인하였다. 이에 따라 폐기물처리시설 검사방법의 고도화를 이루기 위해 세부검사방법의 정량적 기준 적립 뿐만 아니라 각 시설의 정기검사 시 1년간의 운영자료 등을 수집하여 폐기물의 흐름을 파악하고 처리시설의 적정운영 여부를 판단한다면, 처리시설의 운영 및 관리효율이 상승할 것으로 판단된다.

종간직접전자전달 전도체로서 Magnetite(Fe3O4)가 음폐수의 메탄생산에 미치는 영향 (Effects of Magnetite(Fe3O4) as Electrical Conductor of Direct Interspecies Electron Transfer on Methane Yield of Food Wastewater)

  • 이준형;김태봉;김창현;윤영만
    • 유기물자원화
    • /
    • 제31권1호
    • /
    • pp.15-26
    • /
    • 2023
  • 혐기소화에 의한 메탄생산은 유기물이 가수분해, 산생성 단계를 거쳐 아세트산생성균과 메탄생성균 간의 영양공생 (syntrophy)에 의해 일어난다. 본 연구에서는 종간 영양공생 기작인 종간직접전자전달 (DIET, Direct Interspecies Electron Transfer) 과정을 촉진시키기 위하여 전도체인 마그네타이트 (Fe3O4) 첨가가 음폐수의 메탄생산에 미치는 영향을 파악하고자 하였다. 이를 위해, 본 연구에서는 회분식 혐기반응기를 이용하여 마그네타이트 투입량에 따른 음폐수의 메탄퍼텐셜 (Bu)과 최대메탄생산속도 [Rm(t0)]를 분석하였다. 마그네타이트 무처리구의 메탄퍼텐셜은 0.496 Nm3/kg-VSadded이었으며, 21.06일에 38.24 mL/day의 최대메탄생산속도를 보였다. 마그네타이트 5, 10, 15, 20, 25, 30, 40, 70, 100mM 처리구의 메탄퍼텐셜은 각각 0.502, 0.498, 0.512, 0.510, 0.518, 0.523, 0.524, 0.540, 0.549 Nm3/kg-VSadded이었으며, 마그네타이트 투입량 증가에 따라 유의성 있는 메탄퍼텐셜의 증가 경향을 보였다. 최대메탄생산속도는 무처리구와 비교하여 마그네타이트 처리구에서 증가하였으며 15mM 처리구에서 36.95%까지 증가하였다. 또한, 마그네타이트 투입농도가 증가함에 따라 최대메탄생산속도에 도달하는 기간(t0)은 무처리 21.06일에서 마그네타이트 100mM 처리 14.67일로 크게 단축되었다. 따라서, 마그네타이트 투입에 따른 음폐수의 메탄퍼텐셜과 최대메탄생산속도가 크게 향상되었다.