• Title/Summary/Keyword: biofilter

Search Result 363, Processing Time 0.026 seconds

Application of biofilter for removing malodomus gas generated from compost factory (퇴비화 '공장에서 발생되는악취'를 제거하기 위한 Biofilter의 적용)

  • Kim, Chang-Il;Lee, Jae-Ho;Kim, Dae-Seung;Nam, Sang-Il;Nam, Yi
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.3
    • /
    • pp.45-56
    • /
    • 1999
  • A biofilter was established to remove the ammonia, which is representative nitrogen-contained malodorous gas. in a compost factory. Removal efficiency of ammonia and hydrogen sulfide also was investigated. A quantity of malodor gas produced in a compost factory was affected greatly by the weather. compost states and working condition of a fertilizing mixer, and the produced gas concentrations doubled by above various parameters. By operating a water scrubbing system for removing water-soluble malodorous gases effectively. we could improve the removal efficiency over three times. We investigated long-term stability of biofilter under continuous gas flow(SV=500h-1) for 100 days. The results showed 30 days of microbial retention time. After the days, deodorization efficiency of biofilter was kept steady state. and the removal efficiency was kept over 95% for ammonia and 97% for hydrogen so]fide. respectively. The electric consumption of the biofilter, which could treat malodorous gas of 100$\textrm{m}^3$/min, applied in the compost factory was evaluated about 80u0day and water consumption was 80~100$\ell$/day. These results concluded that the biofilter is a excellent deodorization technology as well as cost-effective for removing malodorous gas produced in a compost factory.

  • PDF

Semi-pilot Scaled Hybrid Process Treatment of Malodorous Waste Air: Performance of Hybrid System Composed of Biofilter Packed with Media Inoculated with Thiobacillus sp. IW and Return-sludge and Photocatalytic Reactor (악취폐가스의 세미파일럿 규모 하이브리드 공정 처리: Thiobacillus sp. IW 및 반송슬러지를 접종한 담체를 충전한 바이오필터와 광촉매반응기로 구성된 하이브리드시스템의 운전)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.191-198
    • /
    • 2014
  • A semi-pilot hybrid system composed of a photocatalytic reactor and a biofilter was operated under various operating conditions in order to treat malodorous waste air containing both hydrogen sulfide and ammonia which are major air pollutants emitted from composting factories and many publicly owned treatment works (POTW). When both hydrogen sulfide and ammonia contained in malodorous waste air were treated simultaneously by a biofilter system, its performance of ammonia removal was much more poor than that by a biofilter system treating waste air containing only ammonia, unlike its performance of hydrogen sulfide removal. For semi-pilot hybrid system, the removal efficiencies of hydrogen sulfide and ammonia turned out to be ca. 83 and 65%, respectively. Therefore, for semi-pilot hybrid system, the removal efficiencies of hydrogen sulfide and ammonia was increased by ca. 4 and 30%, respectively, compared to those of semi-pilot biofilter system (control). In addition, the maximum elimination capacities of hydrogen sulfide and ammonia for semi-pilot hybrid system turned out to be ca. 60 and $37g/m^3/h$, respectively. These maximum elimination capacities of hydrogen sulfide and ammonia were estimated to be ca. 9.1% and ca. 23.3% greater than those for semi-pilot biofilter system (control), respectively. Therefore, the semi-pilot hybrid system contributed the enhancement of removal efficiency and the maximum elimination capacity of ammonia in a higher degree than that of hydrogen sulfide, compared to the semi-pilot biofilter system.

Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle (가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.605-617
    • /
    • 2015
  • The ultimate goal of this research is to develop a botanical biofiltration system that combines a green interior, biofiltering, and automatic irrigation to purify indoor air pollutants according to indoor space and the size of biofilter. This study was performed to compare the stability of air flow characteristics and removal efficiency (RE) of fine dust within a wall-typed (vertical) botanical biofilter depending on humidifying cycle and to investigate RE of volatile organic compounds (VOCs) by the biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be suitable for indoor space utilization. As a result, relative humidity, air temperature, and soil moisture content (SMC) within the biofilter showed stable values regardless of three different humidifying cycles operated by the metering pump. In particular, SMCs were consistently maintained in the range of 27.1-29.7% during all humidifying cycles; moreover, a humidifying cycle of operating for 15 min and pausing for 45 min showed the best horizontal linear regression (y = 0.0008x + 29.09) on SMC ($29.0{\pm}0.2%$) during 120 hour. REs for number of fine dust (PM10) and ultra-fine dust (PM2.5) particles passed through the biofilter were in the range of 82.7-89.7% and 65.4-73.0%, respectively. RE for weight of PM10 passed through the biofilter was in the range of 58.1-78.9%, depending on humidifying cycle. REs of xylene, ethyl benzene, total VOCs (TVOCs), and toluene passed through the biofilter were in the range of 71.3-75.5%, while REs of benzene and formaldehyde (HCHO) passed through the biofilter were 39.7% and 44.9%, respectively. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was very effective for indoor air purification.

Treatment of an Authentic Textile-dyeing Wastewater Utilizing a Fluidized Biofilter and Hybrid Recirculating System Composed of the Fluidized Biofilter and a UV/photocatalytic Reactor (실제 혼합염색폐수의 유동상 시스템을 활용한 미생물처리와 하이브리드 재순환시스템처리)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.53 no.1
    • /
    • pp.71-77
    • /
    • 2015
  • A fluidized biofilter was filled with Pseudomonas sp. and Bacillus cereus/thuringiensis-fixed waste-tire crumb media and was run to treat authentic textile-dyeing wastewater mixed with alkaline polyester-weight-reducing wastewater. As a result, its removal efficiency of $COD_{Cr}$ and color were 75~80% and 67%, respectively. In addition, upon constructing hybrid-recirculating system composed of the fluidized biofilter and a 450 W-UV/photocatalytic reactor, only fluidized biofilter was run bypassing UV/photocatalytic reactor at stage I. Subsequently, the hybrid system was continuously run at stage II-i, ii and iii. At stage II-i, the total removal efficiency of $COD_{Cr}$ was enhanced to be 80~85%, compared to 75% at stage I, owing to 20~30% removal efficiency of the UV/photocatalytic reactor. However, at stage II-i, the total removal efficiency of color was enhanced to be 65~70%, compared to 45~65% at stage I, even though the removal efficiency of the UV/photocatalytic reactor was tantamount to merely 0~5%. As far as the removal efficiency of fluidized biofilter of the hybrid-recirculating system is concerned, its removal efficiency of color was enhanced by the synergy effect of the hybrid-recirculating system unlike $COD_{Cr}$. Besides, despite of the increase of hybrid-recirculating system-recycle ratio, the deactivation of photo-catalytic activity was scarcely observed to eliminate the color while its irreversible deactivation was observed to eliminate $COD_{Cr}$.

Effect of Biofilter Made of Composted Pine Tree Bark and Perils on Reducing Odor from Pig House (부숙수피-펄라이트 혼합충전재의 돈사악취 제거 효과)

  • Lee, Seung-Joo;Chang, Dong-Il;Chang, Hong-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.2
    • /
    • pp.118-123
    • /
    • 2006
  • To remove effectively order component ($NH_3\;and\;H_2S$) from pig house, biofilter was made of composted pine tree bark and polite and odor removal efficiency was evaluated in the lab and pilot scales. The columns were designed with ${\Phi}120mm{\times}450mm$ (H) and ${\Phi}850mm{\times}900mm$ (H) in the size in the lab and pilot scale testes, respectively. Single material of composted pine tree bark and polite and the mixture of two materials with 7:3 ratios (vol/vol) were packed in the column, and, herein air flow was controlled upward direction from column bottom. To enhance the efficiency of biofilter, ammonia (Rhodococcus equi A3) and hydrogen sulfide oxidizing bacteria (Alcaligenes sp. S5-5.2) were inoculated in packing materials before the test Removal effect of ammonia and hydrogen sulfide gases were higher in the mixture$[88.7{\sim}98.2%,\;89.5{\sim}97.9%]$ than that in single packing material (composted pine tree haft$[89.4{\sim}98.7%,\;78.7{\sim}85.6%]$ and petite$[65.3{\sim}73.2%,\;88.7{\sim}98.2%]$ by the lab scale biofilter. In the modeled pig house, about 96 and 91% of ammonia and hydrogen sulfide gases were removed by the pilot scale of biofilter, respectively. Conclusively, composted pine tree bark and polite could be a good candidate of biofilter packing materials to remove the odor components.

Removal of $NH_3$ Gas by a Biofilter Packed with Bio-Carrier Composed of Waste Polyurethane and Wormcast (폐 폴리우레탄과 분변토 미생물담체가 충전된 Biofilter에서의 $NH_3$ 가스의 제거)

  • Lim, Joung-Soo;Lee, Eun-Young
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.122-126
    • /
    • 2007
  • When ammonia ($NH_3$) gas was supplied to a biofilter packed with bio-carrier made of waste polyurthane and worm cast. No odor gases were detected at the outlet of the biofilter when $NH_3$ gas was supplied to the biofilter at the space velocity(SV) of $50\;h^{-1}$ until the inlet $NH_3$ concentration increased to $4\;{\sim}\;454\;ppmv$. The gradual inlet $NH_3$ concentration was set and the removal efficiency of $NH_3$ gas was measured at each condition, while the SV of $NH_3$ increased step by step from 100 to $400\;h^{-1}$. The maximum possible inlet $NH_3$ loading was $11.38\;g-NH_3{\cdot}m^{-3}{\cdot}h^{-1}$ and $34.42\;g-NH_3{\cdot}m^{-3}{\cdot}h^{-1}$ while maintaining the removal efficiency of 100% when the SV was $50\;h^{-1}$ and $100 \;h^{-1}$, respectively. The maximum $NH_3$ loading was $71.28 \;g-NH_3{\cdot}m^{-3}{\cdot}h^{-1}$ with the $NH_3$ removal efficiency of 99.85% at SV $300\;h^{-1}$.

  • PDF

Odor Removal Efficiency of Biofilter Ducting Systems in Indoor Pig House (바이오 필터를 이용한 비육돈사 배기덕트 시설의 악취저감 효과)

  • Song, J.I.;Choi, H.L.;Choi, H.C.;Kwon, D.J.;Yoo, Y.H.;Jeon, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.195-200
    • /
    • 2007
  • Management of odors is essential to swine industry in the Republic of Korea. This study was conducted to evaluate the odor removal efficiency of biofilter ducting systems. Rice straw and auto clave concrete(ALC) were used as filter medium. The ventilation fans(5 units, diameter: 500 mm) at the side wall of a growing pig housing were connected to a biofilter using a duct. The size of a biofilter is $2.5{\times}2{\times}1.2(W{\times}L{\times}H)$. The air velocities at the 300 mm above rice straw and ALC were 0.77 and 0.56 m/s, respectively. Ammonia concentration at the outlet of rice straw and ALC media were 2 and 3 ppm, respectively. Dust concentrations were also measured. The dust concentrations of rice straw and ALC were 93, $32\;mg/m^3$, respectively. There was no significant difference between filter mediums in terms of carbon dioxide concentrations(rice straw: 320, ALC: 270 mg/l). The concentration of hydrogen sulfide was stable over the experimentation. The actual concentrations of hydrogen sulfide were 4, 3 and 3 ppm at the days of 7, 21 and 36, respectively. These results suggest that biofilter ducting systems may remove odors from pig house effectively.

  • PDF

Removal of a High Load of Ammonia by a Marine Bacterium, Vibrio alginolyticus in Biofilter

  • Kim, Nam-Jin;Shoda, Makoto
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.5
    • /
    • pp.316-322
    • /
    • 2002
  • A newly isolated heterotrophic marine bacterium, Vibrio alginolyticus, was used to remove a high load of ammonia gas under non-sterile condition. The cells were inoculated onto an inorganic packing material in a fixed-bed reactor (biofilter), and a high load of ammonia, in the range of ammonia gas concentration of 170 ppm to 880 ppm, was introduced continuously. Sucrose solution and 3% NaCl was supplied intermittently to supplement the carbon source and water to the biofilter. The average percentage of gas removed exceeded 85% for 107-day operation. The maximum removal capacity and the complete removal capacity were$19\;g-N\;kg^{-1}$ dry packing material $day^{-1}$ and $16\;g-N\;kg^{-1}$ dry packing material $day^{-1}$, respectively, which were about three times greater than those obtained in nitrifying sludge inoculated onto the same packing material. On day 82, the enhanced pressure drop was restored to the normal one by NaOH treatment, and efficient removal characteristics were later observed. During this operation, the non-sterile condition had no significantly adverse effect on the removability of ammonia by V. alginolyticus.