• Title/Summary/Keyword: biocompatible

Search Result 442, Processing Time 0.028 seconds

Characterization of Biocompatible Polyelectrolyte Complex Multilayer of Hyaluronic Acid and Poly-L-Lysine

  • Hahn, Sei-Kwang;Allan S. Hoffman
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.3
    • /
    • pp.179-183
    • /
    • 2004
  • A biocompatible polyelectrolyte complex multilayer (PECML) film consisting of poly-L-lysine (PLL) as a polycation and hyaluronic acid (HA) as a polyanion was developed to test its use for surface modification to prevent cell attachment and protein drug delivery. The formation of PECML through the electrostatic interaction of HA and PLL was confirmed by contact angle measurement, ESCA analysis, and HA content analysis. HA content increased rapidly up to 8 cycles for HA/PLL deposition and then slightly increased with an increasing number of deposition cycle. In vitro release of PLL in the PECML continued up to 4 days and ca. 25% of HA remained on the chitosan-coated cover glass after in vitro release test for 7 days. From the results, PECML of HA and PLL appeared to be stable for about 4 days. The surface modification of the chitosan-coated cover glass with PECML resulted in drastically reduced peripheral blood mononuclear cell (PBMC) attachment. Concerned with its use for protein drug delivery, we confirmed that bovine serum albumin (BSA) as a model protein could be incorporated into the PECML and its release might be triggered by the degradation of HA with hyaluronidase.

Effects of Mixing Ratio on the Mechanical and Thermal Properties of Polyelectrolyte Complex Film

  • Son Tae-Won;Kim Byung-Giu;Park Young-Mi;Lim Hak-Sang;Kwon Oh-Kyung
    • Macromolecular Research
    • /
    • v.14 no.3
    • /
    • pp.267-271
    • /
    • 2006
  • Polyelectrolyte complex films were prepared with two compounds, chitosan and poly(ethylene glycol)-monosuccinate, using a casting in order to synthesize a polyelectrolyte complex film with various mole ratios of chitosan and poly(ethylene glycol)-monosuccinate. The solution properties of isolated PEC were investigated for the effects of FTIR, pH value, Brookfield viscosity and cell viability assay using MTT staining. The PEC films were evaluated for mechanical properties by typical stress-strain curve, far thermal properties by DSC and TGA and for surface morphology Properties by SEM. Furthermore, the surface resistance, moisture regain and water content of the films were characterized. The solution properties were affected by several factors including the chitosan content in the PEC, the mixing ratio of PEG and chitosan, and pH. Several PEC in acidic conditions exhibited film formation under appropriate conditions of mixing ratio and chitosan concentration in the mixing process. These PEC films were found to have sufficiently flexible and stable properties due to their hydrophilic structure, which was farmed by the oppositely charged interaction between PEG-MS and chitosan matrix. The results showed the potential applicability of chitosan and poly(ethylene glycol)-monosuccinate films as a biocompatible polymer.

Effect of Iron Content on Microstructure and Mechanical Properties of Ti-Mo-Fe P/M Alloys (Fe 함량에 따른 Ti-Mo-Fe 분말합금의 미세조직 및 기계적 특성 변화)

  • Hwang, HyoWoon;Lee, YongJae;Park, JiHwan;Lee, Dong-Geun
    • Journal of Powder Materials
    • /
    • v.29 no.4
    • /
    • pp.325-331
    • /
    • 2022
  • Beta-titanium alloys are used in many industries due to their increased elongation resulting from their BCC structure and low modulus of elasticity. However, there are many limitations to their use due to the high cost of beta-stabilizer elements. In this study, biocompatible Ti-Mo-Fe beta titanium alloys are designed by replacing costly beta-stabilizer elements (e.g., Nb, Zr, or Ta) with inexpensive Mo and Fe elements. Additionally, Ti-Mo-Fe alloys designed with different Fe contents are fabricated using powder metallurgy. Fe is a strong, biocompatible beta-stabilizer element and a low-cost alloying element. The mechanical properties of the Ti-Mo-Fe metastable beta titanium alloys are analyzed in relation to the microstructural changes. When the Fe content increases, the tensile strength and elongation decrease due to brittle fracture despite a decreasing pore fraction. It is confirmed that the hardness and tensile strength of Ti-5Mo-2Fe P/M improve to more than 360 Hv and 900 MPa, respectively.

Development and Characterization of Horse Bone-derived Natural Calcium Phosphate Powders

  • Jang, Kyoung-Je;Cho, Woo Jae;Seonwoo, Hoon;Kim, Jangho;Lim, Ki Taek;Chung, Pill-Hoon;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.122-133
    • /
    • 2014
  • Purpose: This study was to develop an effective process for fabricating biocompatible calcium phosphate powders (CPPs) using horse bones, and to investigate the characteristics of them. Methods: The characteristics of horse bone powders (HBPs) were investigated according to the different osseous tissue types (compact bone and cancellous bone), bone types (spine and tibia), pretreatment methods (cold water, $H_2O_2$, and hot water), sintering time (4, 8 and 12h), and sintering temperature (600, 900, 1100 and $1300^{\circ}C$). In addition, the grinding methods were compared based on the wet grinding (ball mill) and dry grinding (blade grinder) method to make it as powders. Finally, their cytotoxicity and cell viability were checked. Results: Regardless of the types of osseous tissues and bones, HBPs were well fabricated as biocompatible CPPs. It was also found that the pretreatment methods did not influence on the resultants, showing well-fabricated HBPs. Considering the processing time, the hot water method was the most suitable compared to other pretreatment methods. Further, 12h-sintering time was sufficient to remove residual organic compounds. The sintering temperatures greatly affected the properties of bone powders fabricated. The x-ray diffraction (XRD) peak of horse bone sintered at $600^{\circ}C$ was most closed to that of hydroxyapatite (HA). Our bioactivity study demonstrated that the HBPs fabricated by sintering horse bones at $1300^{\circ}C$ showed the best performance in terms of cell viability whereas the HBPs $1100^{\circ}C$ showed the cytotoxicity. Conclusions: Using various types of horse bone tissues, biocompatible CPPs were successfully developed. We conclude that the HBPs may have a great potential as biomaterials for various biological applications including bone tissue engineering.

Surface Chemistry in Biocompatible Nanocolloidal Particles (생체 적합한 나노입자와 계면화학)

  • Kim Jong-Duk;Jung Jae Hyun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.3 s.47
    • /
    • pp.295-305
    • /
    • 2004
  • Colloid and surface chemistry have been focused on surface area and surface energy. Local surface properties such as surface density, interaction, molecular orientation and reactivity have been one of interesting subjects. Systems of such surface energy being important would be listed as association colloid, emulsion, particle dispersion, foam, and 2-D surface and film. Such nanoparticle systems would be applied to drug delivery systems and functional cosmetics with biocompatible and degradable materials, while nanoparticles having its size of several nm to micron, and wide surface area, have been accepted as a possible drug carrier because their preparation, characteristics and drug loading have been inves-tigated. The biocompatible carriers were also used for the solubilization of insoluble drugs, the enhancement of skin absorption, the block out of UV radiation, the chemical stabilization and controlled release. Nano/micro emulstion system is classified into nano/microsphere, nano/microcapsule, nano/microemulsion, polymeric micelle, liposome according to its prep-aration method and size. Specially, the preparation method and industrial applications have been introduced for polymeric micelles self-assembled in aqueous solution, nano/microapsules controlling the concentration and activity of high concen-tration and activity materials, and monolayer or multilayer liposomes carrying bioactive ingredients.

마이크로머시닝 기술의 의학 및 생물학 응용

  • 장준근;김용권
    • The Magazine of the IEIE
    • /
    • v.24 no.10
    • /
    • pp.63-72
    • /
    • 1997
  • Application of MEMS to biologic system mainly categorized into bio-electronics and micro-medical systems, Bio-electronics concerns on the biocompatible electronic device, in-vivo sensors, the sensors based on biological materials, biological materials for electronics and optics, the concepts and materials Inspired by biology and useful for electronics, the algorithm inspired by biology, artificial sense, and the biologic-inorganic hybrids. Micro-medical systems are utilited into the drug delivery systems, micro patient monitoring systems, micro prosthesis and artificial organs, cardiology related prothesis, analysis systems, and the minimal invasive surgery tools based on the m icrom achining technology.

  • PDF

The Development of New Biomaterial for Restoration of Hard Tissue Defects (경조직 결손 수복을 위한 새로운 생체재료의 개발)

  • Kim, Young-Kyun
    • The Journal of the Korean dental association
    • /
    • v.36 no.4 s.347
    • /
    • pp.289-295
    • /
    • 1998
  • Toothash and Plaster of Paris(Calcium sulfate) mixture have been studied for development of new biomaterial since 1992. I have performed the experimental and clinical study for evaluation of biocompatibility and possibility of bony defect reconstruction and clinical application. These materials are biocompatible, osteoconductive and resorbable. Main component of toothash is hydroxylapatite. In the future, I will perform the systematic construction of material and additional research.

  • PDF

Effect of Nitrogen Ion Implantation on Corrosion Resistance of Biocompatible Ti Implant (질소이온의 주입이 생체안전성 티타늄임플란트의 내식성에 미치는 영향)

  • 최종운;손선희
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.134-139
    • /
    • 1999
  • In this study, PSII(plasma source ion implantation) was used to improve the biocompatibility of bone-anchored Ti implant. According to potentiodynamic anodic polarization test in deaerated Hank's solution, open circuit potential of ion implanted specimens were increased compare to that of unimplanted specimen ; besides, passive current density and critical anodic current density of ion implanted specimens were lower than unimplanted specimen.

  • PDF