• 제목/요약/키워드: bio-reactor

검색결과 229건 처리시간 0.025초

Performance Analysis of a Vacuum Pyrolysis System

  • Ju, Young Min;Oh, Kwang Cheol;Lee, Kang Yol;Kim, Dae Hyun
    • Journal of Biosystems Engineering
    • /
    • 제43권1호
    • /
    • pp.14-20
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the performance of a vacuum pyrolysis system, to analyze bio-oil characteristics, and to examine the applicability for farm-scale capacity. Methods: The biomass was pyrolyzed at 450, 480, and $490^{\circ}C$ on an electric heat plate in a vacuum reactor. The waste heat from the heat exchanger of the reactor was recycled to evaporate water from the bio-oil. The chemical composition of the bio-oil was analyzed by gas chromatography-mass spectrometry (GC-MS). Results: According to the analysis, the moisture content (MC) in the bio-oil was approximately 9%, the high heating value (HHV) was approximately 26 MJ/kg, and 29 compounds were identified. These 29 compounds consisted of six series of carbohydrates, 17 series of lignins, and six series of resins. Conclusions: Owing to low water content and the oxygen content, the HHV of the bio-oil produced from the vacuum reactor was higher by about 6 MJ/kg than that of the bio-oil produced from a fluidized bed reactor.

이상 유동 수치해석을 이용한 기포 구동 생물 반응기 내부 최적 구조에 관한 연구 (Study on optimum structure of air-lift bio-reactor using numerical analysis of two-phase flow)

  • 김산;정지홍;이재원;손동기;고한서
    • 한국가시화정보학회지
    • /
    • 제17권3호
    • /
    • pp.24-31
    • /
    • 2019
  • Recently, an air-lift bio-reactor operated by micro bubbles has been utilized to product hydrogen fuel. To enhance the performance, characteristics of hydrodynamics inside the bio-reactor were analyzed using a numerical simulation for two-phase flow. An Eulerian model was employed for both of liquid and gas phases. The standard k-ε model was used for turbulence induced by micro bubbles. A Population Balance Model was employed to consider size distribution of bubbles. A hollow cylinder was introduced at the center of the reactor to reduce a dead area which disturbs circulation of CO bubbles. An appropriate diameter of the draft tube and hollow cylinder were optimized for better performance of the bio-reactor. The optimum model could be obtained when the cross-sectional area ratio of the hollow cylinder to the reactor, and the width ratio of the riser to the downcomer approached 0.4 and 3.5, respectively. Consequently, it is expected that the optimum model could enhance the performance of the bio-reactor with the homogeneous distribution and higher density of CO, and more effective mixing.

하수슬러지를 이용한 Bio-block의 비점오염물질 제거 가능성 평가 (Evaluation of the Feasibility of Eliminating Non-point Source Pollution Using Waste Sewage Sludge Bio-blocks)

  • 한상무;김도형;정병곤
    • 한국물환경학회지
    • /
    • 제37권5호
    • /
    • pp.363-368
    • /
    • 2021
  • On the assessment results of the non-point source pollutant removability of bio-block using waste sewage sludge, at the reactor's initial operation stage, the removal efficiency of COD was slightly unstable. However, after the reactor was stabilized, the COD removal efficiency was higher in the reactor filled with bio-blocks compared to the reactor filled with broken stones. In terms of nitrogen and phosphorus, their removal efficiency was unstable at the initial stage of the reactor operation. This phenomenon was investigated through the bio-block elution experiments. Results indicated that nitrogen and phosphorus were eluted from the bio-blocks affecting their removal at the initial operation. Furthermore, based on elution tests conducted after the dry ashing of the waste sewage sludge, part of the nitrogen and phosphorus was eluted similar to the bio-block elution test results, although considerable amounts of nitrogen and phosphorus were reduced compared to the sludge cake. Prior to the use of the waste sewage sludge bio-blocks as a filter medium to remove non-point source pollutants, a stabilization period of 10 days was required. After the stabilization process, results showed similar characteristics as general aggregates. Moreover, to use the bio-block as a filter medium for the non-point pollutant removal, the filling ratio of 75% was the most suitable as it resulted in the highest nitrogen removal efficiency after the stabilization. The results of this study suggested that waste sewage sludge can be suitably recycled as a mixed raw material for the bio-blocks, with satisfactory application as a filter medium in artificial wetlands, stormwater runoff problems, stream water pollutants to eliminate non-point source pollutants.

BIO-CLOD를 이용한 소화슬러지의 악취저감에 대한 연구 (The Study on the Odor Removal of Digested sludge using BIO-CLOD)

  • 성일화
    • 한국산학기술학회논문지
    • /
    • 제16권12호
    • /
    • pp.8665-8672
    • /
    • 2015
  • 본 연구에서는 하수처리장의 소화슬러지(digest sludge)를 대상으로 악취제거 및 유기물제거에 대한 타당성을 검토하고자 BIO-CLOD를 넣은 반응조와 넣지 않은 반응조에 대하여 24시간, 48시간, 72시간 후 ammonia, methyl mercaptan(MMC) 및 $H_2S$에 대해서 측정하였다. BIO-CLOD를 침적시킨 반응조(BIO-CLOD)에서 24시간 내에 ammonia는 48%인 것에 비해 $H_2S$와 MMC는 98%이상의 높은 제거율을 보인 반면에 BIO-CLOD를 침적시키지 않은 반응조(Non BIO-CLOD)에서는 24시간 내에 ammonia가 45%, $H_2S$는 71%, MMC는 84%로서 악취제거 가능성을 보였다. 암모니아 농도는 시간이 지남에 따라 감소하면서 질산성질소농도는 증가하는 질산화 현상을 보였으며, 소화슬러지내의 유황계 악취성분들이 호기성 미생물들에 의해 산화 분해되어 용액 중의 황산염농도를 증가시키는 데는 BIO-CLOD효과가 있었음을 알 수 있었으며, 황산염농도증가와 대기중의 $H_2S$ 제거율간에는 상관관계가 있음을 알수 있었다. 반응조 유출수에서 유기물의 감소는 짧은 시간 내에서는 BIO-CLOD가 영향을 주지 않았으며, HRT 12시간과 HRT 24시간으로 운전하였을 때 경제적인 면에서 HRT 12시간을 고려해야 할 것으로 판단되었다.

돈분을 이용한 열분해공정 바이오오일의 특성 (Characteristics of Bio-oil by Pyrolysis with Pig Feces)

  • ;최홍림
    • 유기물자원화
    • /
    • 제16권4호
    • /
    • pp.57-63
    • /
    • 2008
  • 본 연구에서는 돈분을 이용한 열분해공정(pyrolysis)에 의한 바이오오일의 특성을 분석하여 보고하였다. 기본적으로 bio-oil 생산을 위한 pilot auger형 반응기는 $400^{\circ}C{\sim}600^{\circ}C$의 고온을 유지하였다. 바이오오일의 특성은 수질분석, 열량가, 원소분석, GC/MS를 이용한 마이오일의 원소, $^1H$ NMR분광기에 의한 functional group 구명 등을 포함한다. 돈분시료를 이용한 바이오오일 생산량은 pilot auger 반응기의 온도가 $550^{\circ}C$일 때 바이오일 생산율은 질량의 21%로서 최대를 나타내었다. 이 결과는 본 연구에서 연속 auger형 반응기의 이송이 편리하고 bio-oil 생산량이 적지 않아 대체 축분처리기술의 하나로 검토할 수 있음을 보였다. 그러나 auger 반응기의 원료로의 열전도가 유동상 반응조보다 낮아서 향후 이를 개선하기 위한 연구가 성공적으로 수행되면 바이오오일 생산량을 제고시킬 수 있을 것으로 판단된다.

  • PDF

Bio-oil production using residual sewage sludge after lipid and carbohydrate extraction

  • Supaporn, Pansuwan;Ly, Hoang Vu;Kim, Seung-Soo;Yeom, Sung Ho
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.202-210
    • /
    • 2019
  • In order to maximize the utilization of sewage sludge, a waste from wastewater treatment facility, the residual sewage sludge generated after lipid and carbohydrate extraction for biodiesel and bioethanol production was used to produce bio-oil by pyrolysis. Thermogravimetric analysis showed that sludge pyrolysis mainly occurred between 200 and $550^{\circ}C$ (with peaks formed around 337.0 and $379.3^{\circ}C$) with the decomposition of the main components (carbohydrate, lipid, and protein). Bio-oil was produced using a micro-tubing reactor, and its yield (wt%, g-bio-oil/g-residual sewage sludge) increased with an increase in the reaction temperature and time. The maximum bio-oil yield of 33.3% was obtained after pyrolysis at $390^{\circ}C$ for 5 min, where the largest amount of energy was introduced into the reactor to break the bonds of organic compounds in the sludge. The main components of bio-oil were found to be trans-2-pentenoic acid and 2-methyl-2-pentenoic acid with the highest selectivity of 28.4% and 12.3%, respectively. The kinetic rate constants indicated that the predominant reaction pathway was sewage sludge to bio-oil ($0.1054min^{-1}$), and subsequently to gas ($0.0541min^{-1}$), rather than the direct conversion of sewage sludge to gas ($0.0318min^{-1}$).

PFR 공정의 ASBF 구조에 의한 유기물제거와 질산화의 영향에 대한 연구 (A Study on the Removal Characteristics of Dissolved Organic and Ammonia Compounds in PFR of Aerated Submerged Bio-film (ASBF) Reactor)

  • 최영익
    • 한국환경과학회지
    • /
    • 제17권11호
    • /
    • pp.1265-1271
    • /
    • 2008
  • Aerated submerged bio-film (ASBF) pilot plant has been developed. The presented studies optimized an inexpensive method of enhanced wastewater treatment. The objectives of this research were to describe pilot scale experiments for efficient removal of dissolved organic and nitrogen compounds by using ASBF reactor in plug-flow reactor (PFR) and improve understanding of dissolved organic matter and nitrogen compounds removal rates with dynamic relationships between heterotrophs and autotrophs in the fixed-film reactor. This research explores the possibility of enhancing the performance of shallow wastewater treatment lagoons through the addition of specially designed structures. This direct gas-phase contact should increase the oxygen transfer rate into the bio-film, as well as increase the micro-climate mixing of water, nutrients, and waste products into and out of the bio-film. This research also investigated the efficiency of dissolved organic matter and ammonia nitrogen removals in the ASBF. As it was anticipated, nitrification activity was highest during periods when the flow rate was lower, but it seemed to decline during times when the flow rate was highest. And ammonia nitrogen removal rates were more sensitive than dissolved organic matter removal rates when flow rates exceeded 2.2 L/min.

Alum 주입 메쉬 침지 여과분리형 생물반응조의 운전 특성과 인 제거 (Phosphorus Removal and Operating Performance of Mesh Filtration Bio-reactor with the Addition of Alum)

  • 정용준;민경석
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.458-463
    • /
    • 2005
  • Considering the characteristics of a filtration bio-reactor equipped with a mesh filter module which can effectively maintain high concentration of biomass and enhanced solid-liquid separation performance, the hybrid process of filtration bio-reactor combined with coagulation was investigated to get improved filtration characteristics as well as water quality in this work. Two bio-reactors (Run-1 & Run-2) were operated under the following conditions: working volume of 25 L, continuous loading of a synthetic wastewater (BOD: 200 mg/L, T-N: 50 mg/L, T-P: 5 mg/L), where an appropriate amount of alum ($Al_2(SO_4)_3{\cdot}18H_2O$) was added once a day into the reactor (Run-2). In the system without using a alum (Run-1), the clogging of mesh filter module was observed two times through 85 days of whole operation. Meanwhile, the filter module did not clog even at higher MLSS concentration (6,000~12,000 mg/L) and the stable filtration (0.7 mid) was continued in the case of using a alum. Due to the stable formation of cake layers, BOD and SS were shown below 6 and 3 mg/L, respectively. T-P and pH of the effluent were changed because of the intermittent addition of the alum. In the case of Al/P=2.5, the average T-P removal efficiency per day was 85.2% and the average T-P concentration of the effluent was 0.3 mg/L. However, the removal efficiency of phosphate was influenced by pH in the reactor.

산업배열 및 부산물을 활용한 1톤급 바이오수소 생산 시뮬레이터 동적 열설계 (Dynamic thermal Design of a 1-ton Class Bio-Hydrogen Production System Simulator Using Industrial Waste Heat and by-Products)

  • 김혜준;김석연;안준
    • 설비공학논문집
    • /
    • 제29권5호
    • /
    • pp.259-268
    • /
    • 2017
  • This paper proposes a hydrogen-based social economy derived from fuel cells capable of replacing fossil fuels and resolving global warming, It thus provides an entry for developing economically feasible social configurations to make use of bio-hydrogen production systems. Bio-hydrogen production works from the principle that microorganisms decompose water in the process of converting CO to $CO_2$, thereby producing hydrogen. This study parts from an analysis of an existing 157-ton class NA1 bio-hydrogen reactor that identifies the state of feedstock and reactor conditions. Based on this analysis, we designed a 1-ton class bio-hydrogen reactor process simulator. We carried out thermal analyses of biological heat reactions, sensible heat, and heat radiation in order to calculate the thermal load of each system element. The reactor temperature changes were determined by modeling the feed mixing tank capacity, heat exchange, and heat storage tank. An analysis was carried out to confirm the condition of the feed mixing tank, heat exchanger, heat storage tank capacity as well as the operating conditions of the system so as to maintain the target reactor temperature.