• Title/Summary/Keyword: bio sensor

Search Result 597, Processing Time 0.025 seconds

A Study on Furrow Autonomous Steering using Furrow Recognition Sensor Module (고랑인식 센서 모듈을 이용한 밭고랑 자율조향에 대한 연구)

  • Cho, Yongjun;Park, Kwanhyung;Yun, Haeyong;Hong, Hyunggil;Oh, Jangseok;Kang, Minsu;Jang, Sunho;Seo, Kabho;Lee, Youngtae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.92-97
    • /
    • 2022
  • In this paper, as a research on autonomous steering for agriculture, a sensor module for furrow recognition was developed through a low-cost distance sensor combination. The developed sensor module was applied to the vehicle, and when driving in a furrow curve, the autonomous steering success rate was 100% at a curvature of 20 m or more, and 70% at a curvature of 15 m or less. The self-steering success rate according to the ground condition showed a 100% success rate regardless of soil, weeds, or mulching film.

Recent Research Trend in Soft Tactile Sensor for Electronic Skin (전자피부(E-Skin)용 유연 촉각센서 연구동향)

  • Jee, Eunsong;Kim, Joo Sung;Kim, Do Hwan
    • Prospectives of Industrial Chemistry
    • /
    • v.21 no.1
    • /
    • pp.3-18
    • /
    • 2018
  • 전자피부(Electronic skin)는 외부 환경과의 상호작용하는 인간 피부의 기능을 대체하여 외부 자극 신호를 전기적 신호로 변환하는 센서들로 이루어진 인공피부로써, 최근 인간과 전자기기 간의 인터페이스에 대한 관심이 급증하면서 이에 대한 많은 연구들이 진행되고 있다. 그중에서도 피부의 주된 기능인 외부 물리적 자극을 인지하는 촉각을 모방하는 촉각센서는 많은 발전을 거쳐 왔으며, 한계를 극복하고자 다양한 연구들이 진행되고 있다. 촉각센서는 압력, 인장, 굽힘과 같은 물리적 자극에 반응하며, 물리적 자극 신호를 아날로그 및 디지털 신호로 변환하여 인지하는 연구들이 폭넓게 개발되고 있다. 또한, 소자의 구조에 따라 물리적 자극을 전달하는 다양한 변환 방식들이 있으며, 최근에는 각 신호 변환 방식의 민감도, 반응속도, 자극 인지 범위 등의 한계점을 극복하고, 소재의 기계적 물성을 향상시키기 위해 소재의 변형을 주거나 생체의 기관 구조 및 외부 자극 인지 원리 등을 모사한 연구들이 많은 관심을 받고 있다. 본 기고에서는 이러한 촉각센서의 물리적 자극 신호 변환 방식과 소재 변형 및 생체 모사를 통한 다양한 연구들을 소개하고자 하며, 이를 통하여 촉각센서의 나아갈 방향을 제시하고자 한다.

Ultra-Low Power MICS RF Transceiver Design for Wireless Sensor Network (WSN 을 위한 초저전력 MICS RF 송수신기 기술 개요 및 설계 기법)

  • Gyu-won Kim;Yu-jung Kim;Junghwan Han
    • Transactions on Semiconductor Engineering
    • /
    • v.2 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • This paper discusses the design of bio-implanted ultra-low-power MICS RF transceivers for wireless sensor networks. The 400 MHz MICS standard was considered for the implementation of the WBAN wireless sensor system, indirectly minimizing radio propagation losses in the human body and the inference with surrounding networks. This paper includes link budget, various transmission and reception architectures for a system design and ultra-low power transceiver circuit techniques for the implementation of RF transceivers that meet MICS standards.

Quantification of Rockwool Substrate Water Content using a Capacitive Water Sensor (정전용량 수분센서의 배지 함수량 정량화)

  • Baek, Jeong-Hyeon;Park, Ju-Sung;Lee, Ho-Jin;An, Jin-Hee;Choi, Eun-Young
    • Journal of Bio-Environment Control
    • /
    • v.30 no.1
    • /
    • pp.27-36
    • /
    • 2021
  • A capacitive water sensor was developed to measure the capacitance over a wide part of a substrate using an insulated electrode plate (30 cm × 10 cm) with copper and Teflon attached on either side of the substrate. This study aimed to convert the capacitance output obtained from the condenser-type capacitance sensor into the substrate water content. The quantification experiment was performed by measuring the changes in substrate water weight and capacitance while providing a nutrient solution and by subsequently comparing these values. The substrate water weight and capacitance were measured every 20 to 30 seconds using the sensor and load cell with a software developed specifically for this study. Using a curve-fitting program, the substrate water content was estimated from the output of the capacitance using the water weight and capacitance of the substrate as variables. When the amount of water supplied was increased, the capacitance tended to increase. Coefficient of variation (CV) in capacitance according to the water weight in substrate was greater with the 1.0 kg of water weight, compared with other weights. Thus, the fitting was performed with higher than 1.0 kg, from 1.7 to 6.0 kg of water weight. The correlation coefficient between the capacitance and water weight in substrate was 0.9696. The calibration equation estimated water content from the capacitance, and it was compared with the substrate water weight measured by the load cell.

Development of a wireless telemetry system based on MICS standard (MICS 표준에 기반한 무선 텔레메트리 시스템 개발)

  • Lee, Seung-Ha;Park, Il-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.

Recognition of Tabacco Ripeness & Grading based on the Neural Network (신경회로망을 이용한 담배 숙도인식 및 등급판정)

  • LEE, S.S.;LEE, C.H.;LEE, D.W.;HWANG, H.
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.17 no.1
    • /
    • pp.5-14
    • /
    • 1995
  • Efficient algorithms for the automatic classification of flue-cured tovacco ripeness and grading have been developed The ripeness of the tobacco was classified into 4 levels vased on the color. The lab-built simple RGB color measuring system was utilized for detecting the light reflectance of the tobacco leaves. The measured data were used far training the artificial neural network The performance of the trained network was also tested far the untrained samples. The spectrophotometer was used to detect the light reflectance and absorption of the graded tobacco leaves in the frequency ranges of the visible light The measured data and the statistical analysis was performed to investigate the light characteristics of the graded samples. The measured data were obtained from samples of 5 different grades directly without considering the leaf positions. Those data were used far training the artificial neural network The performance of the trained network was also tested far the untrained samples. The neural network based sensor information processing showed successful results for grading of tobacco leaves.

  • PDF

BioMEMS-EARLY DISEASE DETECTION (BioMEMS 기반의 조기 질병 진단 기술에 관한 연구)

  • Singh, Kanika;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2781-2784
    • /
    • 2007
  • Early detection of a disease is important to tackle treatment issues in a better manner. Several diagnostic techniques are in use, these days; for such purpose and tremendous research is going on to develop newer and newer methods. However, more work is required to be done to develop cheap and reliable early detection techniques. Micro-fluidic chips are also playing key role to deliver new devices for better health care. The present study focuses on a review of recent developments in the interrogation of different techniques and present state-of-the-art of microfluidic sensor for better, quick, easy, rapid, early, inexpensive and portable POCT (Point of Care testing device) device for a particular study, in this case, bone disease called osteoporosis. Some simulations of the microchip are also made to enable feasibility of the development of a blood-chip-based system. The proposed device will assist in early detection of diseases in an effective and successful manner.

  • PDF

Analysis of reactive species in water activated by plasma and application to seed germination

  • Choi, Ki-Hong;Lee, Han-Ju;Park, Gyungsoon;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.162.1-162.1
    • /
    • 2015
  • The use of plasma has increased in bio-application field in recent years. Particularly, water treated by arc discharge or atmospheric pressure plasma has been actively utilized in bio-industry. In this study, we have developed a plasma activated water generating system. For this system, two kinds of plasma sources; dielectric barrier discharge (DBD) plasma and arc discharge plasma have been used. The discharge energy was calculated using the breakdown voltage and current, and the emission spectrum was measured to investigate the generated reactive species. We also analyzed the amount of reactive oxygen and nitrogen species in water using the chemical methods and nitric oxide sensor. Finally, the influence of plasma generated reactive species on the germination and growth of spinach (Spinacia oleracea) was investigated. Spinach is a green leafy vegetable that contains a large amount of various physiologically active organic compounds. However, it is characterized with a low seed germination rate.

  • PDF

Development of micro-mold for New Injecton Molder to fabricate Micro-Nano system (Micro-Nano 시스템 제조를 위한 소형 차세대 사출기 개발과 이를 위한 Micro meld의 개발)

  • 황교일;류경주;김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.910-913
    • /
    • 2002
  • Recently, the sensor and actuator are developed with EAP(Electro Active Polymer). Common used of they is close at hand, the bio chip and Lab on a chip are researched. For developed bio and micro system, a researcher applies semiconductor fabrication or make it by his hand. But, this method takes long time and a tolerance is large So they are problem of common used. So In this paper we propose the new inject ion molder and micro mold. The micro mold is different from exist ing mold. In this paper, the fabration of micro mold is introduced to inject.

  • PDF

Measurement of Glucose Concentration Using a Bio-Sensor$(\mu{FIAS)}$ (바이오 센서$(\mu{FIAS)}$를 이용한 Glucose 농도 측정)

  • ;Joseph Irudayaraj
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.02a
    • /
    • pp.209-214
    • /
    • 2003
  • 바이오 센서는 생물학적 인식 반응(Biological recognition reaction)이나 생물 촉매 공정(Bio-catalytic process)을 측정 가능한 전기적 신호로 변환시켜주는 적절한 변환기(Transducer)와 같은 생물학적 인식요소로 이루어진 감지 장치를 의미한다. 1962년 효소를 이용한 Glucose 전극봉의 개발이후 이 분야에 대한 수많은 연구와 기기의 개발이 진행되어왔다. 분석도구로써 바이오 센서는 효소, 항체, 수용체, 세포, 조직 등과 같은 생물학적 인식 요소들에 광범위하게 적용 가능하다는 장점이 있는 반면, 위에 열거한 생물학적 인식 요소들의 불안정성으로 인해 신뢰성이 유지되지 못하는 단점을 동시에 지니고 있다. (중략)

  • PDF