• 제목/요약/키워드: bending connection

검색결과 240건 처리시간 0.028초

Mechanical splices of reinforcing bars subjected to bending moments

  • Sadegh Hashemi;Ali Kheyroddin;Ghasem Pachideh
    • Structural Engineering and Mechanics
    • /
    • 제90권3호
    • /
    • pp.301-311
    • /
    • 2024
  • Different methods have been proposed in the literature for splicing the reinforcing bars in the construction of concrete structures, which are alternatively used depending on design requirements. The most common approach is the lap splicing which is known as a cost-effective method although, its main disadvantages including congestion of bars at the lap zone and consequently, material wastage has motivated utilization of the other techniques such as mechanical splices (couplers). To better evaluate the performance of the couplers, 6 reinforced concrete (RC) beams whose difference is only the type and location of splices have been experimentally studied in this paper. Based on the results, the mechanical connection of the bars did not markedly affect the load-carrying capacity of the specimens. Moreover, it was observed that after applying the loads and failure of the specimens, none of the bars ruptured at the splice location and all couplers remained undamaged.

2겹 판재 멀티포밍 장치에 관한 연구 (A study of Double Sheet Multi-forming Equipment)

  • 윤재웅;손옥종
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.49-55
    • /
    • 2017
  • 대부분의 모터 케이스는 방수기능과동심도, 직각도 품질 등이 우수한딥드로잉 제품을 채택하고 있으며 그외 방수기능이 필요없는 블로우모터, 시트모터 등 실내에 장착되는 모터 케이스는 멀티포밍 제조방법을 채택하고 있다. 딥드로잉 공정은 드로잉 성형, 트리밍 및 피어싱 등 약 12공정을 소화할수 있는 고가의 트랜스퍼 프레스가 필요하다. 하지만 멀티포밍 공법은 멀티포밍기 1대 또는 멀티포밍기 1대와 프레스 1대의 구성으로 이루어지기 때문에 저렴한 투자로도 완제품 생산이 가능하다. 멀티포밍기는 대부분 수입이 되는 고가설비 이고 국내 중소기업이 개발한 굽힘/전단가공 일체형 멀티포밍기는 생산원가를 줄이는데 부족하여 굽힘/전단 분리형 멀티포밍기를 본 연구를 통해 개발하였다. 일체형 멀티포밍기는 비교적 얇고 작은소형 제품을 제한적인 작업 방법으로 사용된다. 크고 소재가 두꺼운 제품은 전단 하중이 높아 단발 크랭크 프레스를 이용하고 블랭킹 후 멀티포밍기로 이동 작업자가 수작업으로 소재를 공급한다. 멀티포밍기에서 벤딩 작업이 이루어지면 다시 프레스로 이송해 치수를 교정한다. 이러한 작업공정 분산은 생산성 저하, 품질이슈 및 과도한 인원 투입으로 원가경쟁력 저하를 가져왔다 이에 굽힘/전단가공 공정분리와 설비자동화를 통하여 안정되고 원가가 절감되는 생산체계를 갖추고자 하는게 본 연구의 목적이다.

낙엽송 부재의 이중 전단 볼트 접합부 강도 성능 (Strength Property of Double Shear Bolted-Connections of Larch)

  • 박천영;김광모;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제33권1호통권129호
    • /
    • pp.7-16
    • /
    • 2005
  • 본 연구에서는 국산 낙엽송 부재를 이용한 이중 볼트 전단 접합부의 성능을 평가하였다. 주부재로 두께 39 mm, 89 mm, 139 mm, 189 mm로 제재된 국산 낙엽송 제재목과 국산 낙엽송으로 제조된 두께 80 mm, 140 mm, 170 mm 집성재를 사용하였으며, 측면 부재로는 동일 두께의 제재목과 6 mm 철판을 사용하였으며, 접합 철물로는 M12, M16, M20 볼트를 사용하였다. 접합부에 대한 하중 방향은 주부재와 측면 부재의 목리 경사에 대해 수직, 수평한 경우에 대하여 실시하였다. 다우얼 지압 강도 실험을 통해 부재의 다우얼 지압 강도를 산출하고, 볼트 휨 실험을 통해 볼트의 휨 강도를 구한뒤, 최종 볼트 접합부 실험을 통해 접합부 성능을 평가하였으며, 최종 결과는 EYM (European Yield Model)을 사용한 계산값과 비교 평가하였다. 연구 결과 국산 낙엽송 부재의 이중 전단 볼트 접합부 성능은 EYM을 사용하여 얻어진 계산값과 비교하였을 때 그에 상응하거나 그 이상임을 알 수 있었으며, 특히 측면 부재가 제재목인 경우는 거의 일치함을 알 수 있었다. 파괴 모드는 옹이나 건조 결함 등의 영향을 많이 받으며 주부재의 두께가 작을 경우는 mode I, 주부재가 커짐에 따라 mode III으로 옮겨감을 알 수 있었다.

복합긴장방식이 적용된 세그멘탈 U형 거더 정적 거동 연구 (A Study of Statistic Behavior of Segmental U-shaped Prestressed Concrete Girder Applied with Integrated Tensioning Systems)

  • 장현옥;장일영
    • 한국재난정보학회 논문집
    • /
    • 제20권2호
    • /
    • pp.329-338
    • /
    • 2024
  • 연구목적: 본 연구는 긴장방식을 복합적으로 적용한 세그멘탈 PSC U형 거더에 대한 해석적 거동을 기반으로 실대형 실험체의 휨 거동 결과를 평가하여 거동의 안전성을 검증하고자 한다. 연구방법: 도로교설계기준 한계상태설계법의 사용한계 및 극한한계상태 설계 결과를 바탕으로 40m 실대형 실험체의 가력하중을 산정하고 이에 대한 4점재하방식 정적 하중재하 실험을 수행하였다. 연구결과: 설계하중, 균열하중 및 극한하중이 작용할 때 해석적 처짐값 대비 97.1%, 98.5% 그리고 79.0%에 해당하는 실험체 처짐이 발생하였다. 설계하중, 균열하중 및 극한하중이 작용할 때 균열계는 각 연결부에서 0.009~0.035mm, 0.014~0.050mm, 6.383~5.522mm로 계측되었다. 결론: 균열하중 재하시까지 실험체는 탄성적으로 거동하였고 균열발생 후 극한하중까지 변형율-경화현상을 보이며 작용하중에 대하여 휨 저항 거동이 뚜렷이 나타났음을 확인하였다. 실대형 실험체 연결부(Dry Joint) 균열은 시설물 상태평가 B등급 기준 25% 미만의 결과로써 연결부의 탄성적 거동을 확인하였고 극한하중 제거 후 최종적 잔류 변형은 0.114mm로써 세그먼트 연결부의 안정적 거동을 확인하였다.

부모멘트를 받는 합성보의 전단합성 거동에 대한 유한요소해석 (FE Analysis of the Composite Action in the Composite Beam subjected to the Hogging Moment)

  • 신현섭
    • 한국산학기술학회논문지
    • /
    • 제14권8호
    • /
    • pp.4048-4057
    • /
    • 2013
  • 부모멘트를 받는 합성보 슬래브에서 인장균열 발생과 균열의 진행에 따른 슬래브의 강성저하가 전단연결부의 합성거동에 미치는 영향을 실험적으로 분석하기는 매우 어렵다. 본 논문에서는 부모멘트를 받는 합성보에서 콘크리트 슬래브 및 강재 보, 스터드를 포함한 전단연결부 등의 형상과 물성을 최대한 실제와 유사하게 모델링하는 기법을 이용함으로써, 부재 간 합성작용을 해석할 수 있는 3차원 유한요소모델을 개발하였다. 개발된 3차원 유한요소모델을 이용하여 부모멘트 구간에 설치되는 합성보의 전체 휨거동 및 기존의 1차원 또는 2차원 모델로는 해석이 어려운 전단합성작용을 분석할 수 있었다. 해석결과에 따르면 부모멘트를 받는 합성보에서의 전단연결부 거동은 철근콘크리트 슬래브의 철근비 및 인장 균열거동에 지배를 받게 됨을 알 수 있었다. 전단연결부의 하중-슬립 관계를 검토해 본 결과, 전단연결부의 슬립강성은 슬래브의 초기균열 및 철근의 항복이 발생한 시점을 기준으로 변화됨을 알 수 있었다. 또한, 구간별로 합성율이 100% 미만으로 설계되는 부분합성 설계가 합성설계의 효율성 측면에서 더 유리할 수 있다는 기존의 실험적 연구결과를 간접적으로 확인할 수 있었다.

Pipe Bursting 공법의 적용성 검토를 위한 주요 성능평가 항목의 기초실험연구 (A study on the basic experiment of performance criteria for application of pipe bursting method in actual field)

  • 박상봉;김기범;서지원;박상혁;구자용
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.435-443
    • /
    • 2018
  • Most of aged water supply pipes have been replaced by the open cut method. However, this method has some limitations because water pipes, in many cases, are buried together with other underground facilities or are buried in the middle of high-traffic roads or in narrow alleyways where boring machines cannot be used. This research developed a pipe bursting device for small diameter pipes that enables pipe replacement without excavating the ground, by the busting of existing buried pipes followed by the traction and insertion of new pipes. As a results of examining the field applicability of the developed device, PE pipes and PVC pipes required the tractive force of 413.65~665.69 kgf and 457.43~791.35 kgf respectively, plus an additional 30 % tractive force per elbow. The proper number of bursting head was demonstrated that the connection of more than 2 heads could secure a stable bending radius of 15D. The developed device can be improved through field experiments involving various pipe types and pipe diameters, as well as presence/absence of elbow, so as to be utilized regardless of diverse variables according to the conditions of the soils surrounding existing pipes.

휨모멘트를 받는 강판 콘크리트(SC) 벽체에서 스터드의 성능개선을 위한 해석적 연구 (Analytical Study for Performance Improvement of Studs for Steel Plate Concrete(SC) Walls subjected to Bending Moment)

  • 조성국;임진선;정영도;이성태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.74-81
    • /
    • 2014
  • 본 연구에서는 휨모멘트를 받는 SC 벽체 스터드의 성능을 최적화시키기 위해 비선형 유한요소법을 사용한 해석적 연구를 수행하였다. SC 벽체에 대한 유한요소모형에서는 접촉, 연결, 그리고 재료에 대한 비선형성을 고려하였다. 그리고 해석모형의 검증을 위해 선행된 실내 실험을 모사하여 계측결과와 해석결과를 비교하였고, 제안된 해석방법의 타당성을 검증하였다. 문헌조사를 통해 해석 대상물의 크기를 결정하였고, 다양한 스터드의 형식과 배치간격을 고려한 해석을 수행하였다. 또한, KEPIC SNG를 만족하는지에 대한 추가적인 검토를 수행하였다. 최종적으로 수치해석과 기준의 검토를 통하여 개선된 스터드의 최적 형식 및 배치안을 제시하였다.

이상거동 변수 기반 고강도 강관 가시설 시스템의 구조 안정성 (Structural Stability of Temporary Facility System using High-Strength Steel Pipes Based on Abnormal Behavior Parameters)

  • 이진우;노명현;이상열
    • 대한토목학회논문집
    • /
    • 제39권1호
    • /
    • pp.1-12
    • /
    • 2019
  • 본 논문에서는 지반굴착 가시설 일부 현장에서 발생하고 있는 고강도 강관 버팀 보의 휨변형 또는 좌굴변형과 같은 이상 거동을 정의하고 강관 버팀보 구조의 연결부 변화에 따른 실물 휨 성능시험을 수행하였다. 또한, 수치적으로 분석 가능한 유발 인자들에 대한 이상 재현 시나리오 구성 후, 구조 해석 및 단면검토를 통하여 5개 하중조합 Case에 대한 변수 해석을 실시하였다. 5가지 이상거동 유발인자는 과굴착 심도, 충격하중, 추가 상재하중, 버팀 보 지간장 등으로 설정하여 3차원 구조해석을 수행하였으며, 2차원해석과 비교하였다. 수치해석 예제는 이상거동 변수를 고려하여 고강도 강관 버팀 보 가시설 시스템의 구조성능에 미치는 영향 및 이상거동 방지방안을 중심으로 상세 규명하였다.

Analytical, experimental and numerical study of timber-concrete composite beams for bridges

  • Molina, Julio C.;Calil, Carlito Junior;de Oliveira, Diego R.;Gomes, Nadia B.
    • Computers and Concrete
    • /
    • 제24권2호
    • /
    • pp.103-115
    • /
    • 2019
  • In this study, the strength and stiffness (EI) of wood-concrete composite beams for bridges with T-shaped cross section were evaluated. Two types of connectors were used: connectors bonded with epoxy adhesive and connectors attached to the wood just by pre-drilling (without adhesive). The connectors consisted of common steel bars with a diameter of 12.5 mm. Initially, the strength and stiffness (EI) of the beams were analyzed by bending tests with the load applied at the third point of the beam. Subsequently, the composite beams were evaluated by numerical simulation using ANSYS software with focus on the connection system. To make the composite beams, Eucalyptus citriodora wood and medium strength concrete were used. The slip modulus K and the ultimate strength values of each type of connector were obtained by direct shear tests performed on composite specimens. The results showed that the connector glued with epoxy adhesive resulted in better strength and stiffness (EI) for the composite beams when compared to the connector fixed by pre-drilling. The differences observed were up to 10%. The strength and stiffness (EI) values obtained analytically by $M{\ddot{o}}hler^{\prime}$ model were lower than the values obtained experimentally from the bending tests, and the differences were up to 25%. The numerical simulations allowed, with reasonable approximation, the evaluation of stress distributions in the composite beams tested experimentally.

신형상 U형 하이브리드 합성보와 기둥 접합부의 내진성능에 관한 연구 (Study on the Cyclic Seismic Testing of U-shape Hybrid Composite Beam-to-Composite Column Connections)

  • 김성배;김상섭;유덕수
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.47-59
    • /
    • 2013
  • 본 연구는 신형상 U형 합성보의 1차 휨실험에 연이은 2차 연구로 U형 합성보와 기둥 접합부의 내진성능시험이다. 실험 변수는 기둥의 종류와 보 춤, 보 상부 플레이트 연속유무, 보 단부 철근 수 등으로 3개의 실험체를 제작하였다. 기둥의 종류는 철골 철근콘크리트 기둥과 CFT 형상의 ACT기둥이며, 보 춤은 300, 500(mm)이다. 접합부상세는 일반적으로 많이 적용하고 있는 짧은 브라켓을 활용한 볼트 접합부이다. 실험결과 변형능력은 2~4(%)의 층간변위각을 확보하였으며, 최대모멘트는 부휨모멘트의 경우 공칭모멘트 이상의 내력이 나타났다.