• 제목/요약/키워드: belgium

Search Result 180, Processing Time 0.026 seconds

Legislation on Aid in Dying in France (조력사망에 관한 프랑스의 입법 동향)

  • Jieun Lee
    • The Korean Society of Law and Medicine
    • /
    • v.25 no.1
    • /
    • pp.193-222
    • /
    • 2024
  • From a global trend, discussions on the patient's death with dignity are gradually progressing from the issue of withdrawal of life-sustaining treatment to the issue of whether to allow assisted death and its requirements. Several states in the United States and Western European countries such as Canada, Belgium, and the Netherlands have institutionalized treatment to accelerate the time of death through the assistance of doctors. In France, after a long period of raising and reviewing issues, discussions on related legislation are taking place at a slower pace than in other European countries. In France, social discussions and legislative attempts on death with dignity have been actively conducted since the late 20th century. The Leonetti Act of 2005 prohibited the continuation of meaningless treatment against the will of patients, and after the Clay-Leonetti Act of 2016, it was legalized to administer intensive and continuous sedatives to patients until death. However, unlike many neighboring European countries, treatment that speeds up the time of death itself is still prohibited in France, even if the patient wants. As the existential and universal question of whether to allow dying patients to die painlessly with the help of a doctor has recently emerged as an important issue, a number of lawmakers have submitted legislation to legalize assisted death. This paper examines the legislative process developed in relation to patients' rights to dignified death in France, and compares and reviews French legislation that attempts to legalize assisted death with the amendment to the Korean Life-Sustaining Treatment Act.

CT Angiography-Derived RECHARGE Score Predicts Successful Percutaneous Coronary Intervention in Patients with Chronic Total Occlusion

  • Jiahui Li;Rui Wang;Christian Tesche;U. Joseph Schoepf;Jonathan T. Pannell;Yi He;Rongchong Huang;Yalei Chen;Jianan Li;Xiantao Song
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.697-705
    • /
    • 2021
  • Objective: To investigate the feasibility and the accuracy of the coronary CT angiography (CCTA)-derived Registry of Crossboss and Hybrid procedures in France, the Netherlands, Belgium and United Kingdom (RECHARGE) score (RECHARGECCTA) for the prediction of procedural success and 30-minutes guidewire crossing in percutaneous coronary intervention (PCI) for chronic total occlusion (CTO). Materials and Methods: One hundred and twenty-four consecutive patients (mean age, 54 years; 79% male) with 131 CTO lesions who underwent CCTA before catheter angiography (CA) with CTO-PCI were retrospectively enrolled in this study. The RECHARGECCTA scores were calculated and compared with RECHARGECA and other CTA-based prediction scores, including Multicenter CTO Registry of Japan (J-CTO), CT Registry of CTO Revascularisation (CT-RECTOR), and Korean Multicenter CTO CT Registry (KCCT) scores. Results: The procedural success rate of the CTO-PCI procedures was 72%, and 61% of cases achieved the 30-minutes wire crossing. No significant difference was observed between the RECHARGECCTA score and the RECHARGECA score for procedural success (median 2 vs. median 2, p = 0.084). However, the RECHARGECCTA score was higher than the RECHARGECA score for the 30-minutes wire crossing (median 2 vs. median 1.5, p = 0.001). The areas under the curve (AUCs) of the RECHARGECCTA and RECHARGECA scores for predicting procedural success showed no statistical significance (0.718 vs. 0.757, p = 0.655). The sensitivity, specificity, positive predictive value, and the negative predictive value of the RECHARGECCTA scores of ≤ 2 for predictive procedural success were 78%, 60%, 43%, and 87%, respectively. The RECHARGECCTA score showed a discriminative performance that was comparable to those of the other CTA-based prediction scores (AUC = 0.718 vs. 0.665-0.717, all p > 0.05). Conclusion: The non-invasive RECHARGECCTA score performs better than the invasive determination for the prediction of the 30-minutes wire crossing of CTO-PCI. However, the RECHARGECCTA score may not replace other CTA-based prediction scores for predicting CTO-PCI success.

The Comparison of Basic Science Research Capacity of OECD Countries

  • Lim, Yang-Taek;Song, Choong-Han
    • Journal of Technology Innovation
    • /
    • v.11 no.1
    • /
    • pp.147-176
    • /
    • 2003
  • This Paper Presents a new measurement technique to derive the level of BSRC (Basic Science and Research Capacity) index by use of the factor analysis which is extended with the assumption of the standard normal probability distribution of the selected explanatory variables. The new measurement method is used to forecast the gap of Korea's BSRC level compared with those of major OECD countries in terms of time lag and to make their international comparison during the time period of 1981∼1999, based on the assumption that the BSRC progress function of each country takes the form of the logistic curve. The US BSRC index is estimated to be 0.9878 in 1981, 0.9996 in 1990 and 0.99991 in 1999, taking the 1st place. The US BSRC level has been consistently the top among the 16 selected variables, followed by Japan, Germany, France and the United Kingdom, in order. Korea's BSRC is estimated to be 0.2293 in 1981, taking the lowest place among the 16 OECD countries. However, Korea's BSRC indices are estimated to have been increased to 0.3216 (in 1990) and 0.44652 (in 1999) respectively, taking 10th place. Meanwhile, Korea's BSRC level in 1999 (0.44652) is estimated to reach those of the US and Japan in 2233 and 2101, respectively. This means that Korea falls 234 years behind USA and 102 years behind Japan, respectively. Korea is also estimated to lag 34 years behind Germany, 16 years behind France and the UK, 15 years behind Sweden, 11 years behind Canada, 7 years behind Finland, and 5 years behind the Netherlands. For the period of 1981∼1999, the BSRC development speed of the US is estimated to be 0.29700. Its rank is the top among the selected OECD countries, followed by Japan (0.12800), Korea (0.04443), and Germany (0.04029). the US BSRC development speed (0.2970) is estimated to be 2.3 times higher than that of Japan (0.1280), and 6.7 times higher than that of Korea. German BSRC development speed (0.04029) is estimated to be fastest in Europe, but it is 7.4 times slower than that of the US. The estimated BSRC development speeds of Belgium, Finland, Italy, Denmark and the UK stand between 0.01 and 0.02, which are very slow. Particularly, the BSRC development speed of Spain is estimated to be minus 0.0065, staying at the almost same level of BSRC over time (1981 ∼ 1999). Since Korea shows BSRC development speed much slower than those of the US and Japan but relative]y faster than those of other countries, the gaps in BSRC level between Korea and the other countries may get considerably narrower or even Korea will surpass possibly several countries in BSRC level, as time goes by. Korea's BSRC level had taken 10th place till 1993. However, it is estimated to be 6th place in 2010 by catching up the UK, Sweden, Finland and Holland, and 4th place in 2020 by catching up France and Canada. The empirical results are consistent with OECD (2001a)'s computation that Korea had the highest R&D expenditures growth during 1991∼1999 among all OECD countries ; and the value-added of ICT industries in total business sectors value added is 12% in Korea, but only 8% in Japan. And OECD (2001b) observed that Korea, together with the US, Sweden, and Finland, are already the four most knowledge-based countries. Hence, the rank of the knowledge-based country was measured by investment in knowledge which is defined as public and private spending on higher education, expenditures on R&D and investment in software.

  • PDF

Economic Value of the Sirolimus Eluting Stent($CYPHER^{TM}$) in Treating Acute Coronary Heart Disease (관상동맥질환 치료를 위한 시롤리무스 방출 스텐트 ($CYPHER^{TM}$)의 경제성 분석)

  • Lee, Hoo-Yeon;Park, Eun-Cheol;Park, Ki-Dong;Park, Ji-Eun;Kim, Young;Lee, Sang-Soo;Kang, Hye-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.4
    • /
    • pp.339-348
    • /
    • 2003
  • Objective : To quantify the economic value of the Sirolimus fluting Stent ($CYPHER^{TM}$) in treating acute coronary heart disease (CMD), and to assist in determining an adequate level of reimbursement for $CYPHER^{TM}$ in Korea. Methods : A decision-analytical model, developed by the Belgium Health Economics Disease Management group, was used to investigate the incremental cost-effectiveness of $CYPHER^{TM}$ versus conventional stenting. The time horizon was five years. The probabilities for clinical events at each node of the decision model were obtained from the results of large, randomized, controlled clinical trials. The initial care and follow-up direct medical costs were analyzed. The initial costs consisted of those for the initial procedure and hospitalization, The follow-vp costs included those for routine follow-up treatments, adverse reactions, revascularization and death. Defending on the perspective of the analysis, the costs were defined as insurance covered or total medical costs (=sum of insurance covered and uncovered medical costs). The cost data were obtained from the administrative data of 449 patients that received conventional stenting from five participating Korean hospitals during June 2002. Sensitivity analyses were peformed for discount rates of 3, 5 and 7%. Since the major clinical advantage of $CYPHER^{TM}$ over conventional stenting was the reduction in the revascularization rates, the economic value of $CYPHER^{TM}$, in relation to the direct medical costs of revascularization, were evaluated. If the incremental cost of $CYPHER^{TM}$ per revascularization avoided, compared to conventional stenting, was no higher than that of a revascularization itself, $CYPHER^{TM}$ would be considered as being cost-effective. Therefore, the maximum acceptable level for the reimbursement price of $CYPHER^{TM}$ making the incremental cost-effectiveness ratio equal to the cost of a revascularization was identified. Results : The average weighted initial insurance covered and total medical costs of conventional stenting were about 6,275,000 and 8,058,000 Won, respectively. The average weighted sum of the initial and 5-year follow-up insurance covered and total medical costs of conventional stenting were about 13,659,000 and 17,353,000 Won, respectively. The estimated maximum level of reimbursement price of $CYPHER^{TM}$ from the perspectives of the insurer and society were $4,126,897{\sim}4,325,161$ and $4,939,939{\sim}5,078,181$ Won, respectively. Conclusion : By evaluating the economic value of $CYPHER^{TM}$, as an alternative to conventional stenting, the results of this study are expected to provide a scientific basis for determining the acceptable level of reimbursement for $CYPHER^{TM}$.

Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography (게이트 심근관류 SPECT를 이용한 심기능 분석: 정량분석 소프트웨어 QGS, 4D-MSPECT 및 심초음파법의 비교)

  • Lee, Seok-Mo;Bae, Sang-Kyun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.435-443
    • /
    • 2008
  • Purpose: Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. Materials and Methods: One hundred fourteen patients (male 51, female 63; 29-85 years old, mean $61.3\;{\pm}\;13.3$ years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using $MedCalc^{(R)}$ (MedCalc software, Mariakerke, Belgium). Results: The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8g to 14.1g (stress/rest), The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. Conclusion: There was a good correlation for LVEF, LVEO, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably.

Effect of Waste Nutrient Solution and Fertigation Nutrient Solution on the Growth and Qualities of Tomato Grown by Fertigation (관비재배시 토마토 생육과 품질에 미치는 폐양액과 기존 비료의 효과)

  • Zhang, Cheng Hao;Xu, Zhihao;Kang, Ho-Min;Kim, Il-Seop
    • Horticultural Science & Technology
    • /
    • v.28 no.4
    • /
    • pp.574-579
    • /
    • 2010
  • Waste nutrient solution (WNS) that was the drained nutrient solution of Horticultural Research Institute of Japan for culture tomato in perlite hydroponics showed $1.9-2.4dS{\cdot}m^{-1}$ of EC and 5.7-7.1 pH from April to July. Although ${NH_4}^+-N$ concentration of WNS decreased remarkably, the other nutrients did not change significantly, as compared with supplied solution. There were no significant differences in plant height, stem diameter, and the other growth characteristics of tomato plants grown by 2 fertigation nutrient solutions; BHF (Bountiful Harvest Fertilizer, 10% of N, 13% of $PO_4$, 13% of K, 0.05% of B, 0.05% of Zn, and 0.0023% of Cu that made in Korea) and Megasol (11% of N, 8% of $PO_4$, 34% of K, 0.032% of Mn, 0.002% of B, 0.048% of Fe, 0.0122% of Zn, and 0.0023% of Cu that made in Belgium.); however, the chlorophyll content of tomato leaf was highest in WNS. The fresh and dry weight of tomato plants were higher in 3 fertigation treatments than irrigation of tap water, while there were no significant differences in fresh and dry weight among the 3 fertigation treatments. The mineral content of tomato leaf also did not show any differences among the 3 fertigation treatments and any regular tendency in all minerals. Total yield, fruit weight and fruit numbers of tomato were higher in WNS, followed by Megasol, BHF and control, although there were not any difference among the 3 fertigation nutrient solution treatments. BER(blossom-end rot)of tomato fruits decreased in fertigation treatments, especially, fruits grown in WNS and BHF showed lower BER. However, the transpiration rate of leaf was higher in control, followed by BHF, WNS and Megasol, The fruit size and soluble solids content was higher in 3 fertigation nutrient treatments than control. These results suggest that WNS can be used for fertigation solution in tomato because yield and quality of tomato fruit grown in WNS fertigation treatment were similar to those in 2 fertigation nutrient solutions treatments(BHF, Megasol).

Effect of Selenium on Internal Quality of Basil (Ocimum basilicum L.) During Storage (Basil 양액재배 시 Selenium 첨가가 저장 중 품질에 미치는 영향)

  • 박권우;김민순;강호민;이문정
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.193-200
    • /
    • 2000
  • The object of this study is to investigate the quality change of sweet basil grown with selenium(Se) in hydroponic culture. Sweet basil was cultured with 1 fold herb nutrient solution as suggested by European vegetable R & D Center in Belgium. Before three weeks harvest, sodium selenate(N $a_2$Se $O_4$) was supplied to 2 and 4 mg. $L^{-1}$ in the nutrient solution. Sweet basil was stored at 1$0^{\circ}C$ using 40um ceramic film and PET (polyethylene terephalate) for 15 days in modified atmosphere(MA) storage condition. The weight loss of sweet basil was higher in non-treatment compared to Se treatments in both of two films but it was decreased over 5% in PET treatment. Se concentrations in leaf tissues increased in the response to the treated levels of N $a_2$Se $O_4$concentrations, and this tendency was appeared similar results after storage. There was no significant effect of packing materials on volatilization of Se in sweet basil. The total chlorophyll and essential oil content was increased with increasing N $a_2$Se $O_4$concentration in nutrient solution. The amount of volatilization flavor was not higher at N $a_2$Se $O_4$4mg. $L^{-1}$ treatment compare to others during storage. Se content was 112.73 ug. $g^{-1}$ dry mass at 2 mg. $L^{-1}$ treatment before storage and the decrease of Se content was observed by 50% at 15 days after storage. The condition, which N $a_2$Se $O_4$2mg. $L^{-1}$$^{plement}$ in nutrient solution during growth stage and stored with 40um ceramic film on 1$0^{\circ}C$are acceptable for maintaining of sweet basil quality. Moreover it can be a proper Se concentration for human health. Overall, Se treatment in nutrient solution has effect on promoting and maintaining quality of herb during storage life. Also, there was not significant change of essential oil compounds by volatilization of Se.mpounds by volatilization of Se.

  • PDF

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

"Legal Study on Boundary between Airspace and Outer Space" (영공(領空)과 우주공간(宇宙空間)의 한계(限界)에 관한 법적(法的) 고찰(考察))

  • Choi, Wan-Sik
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.2
    • /
    • pp.31-67
    • /
    • 1990
  • One of the first issues which arose in the evolution of air law was the determination of the vertical limits of airspace over private property. In 1959 the UN in its Ad Hoc Committee on the Peaceful Uses of Outer Space, started to give attention to the question of the meaning of the term "outer space". Discussions in the United Nations regarding the delimitation issue were often divided between those in favour of a functional approach ("functionalists"), and those seeking the delineation of a boundary ("spatialists"). The functionalists, backed initially by both major space powers, which viewed any boundary as possibly restricting their access to space(Whether for peaceful or military purposes), won the first rounds, starting with the 1959 Report of the Ad Hoc Committee on the Peaceful Uses of Outer Space which did not consider that the topic called for priority consideration. In 1966, however, the spatialists, were able to place the issue on the agenda of the Outer Sapce Committee pursuant to Resolution 2222 (xxx1). However, the spatialists were not able to present a common position since there existed a variety of propositions for delineation of a boundary. Over the years, the funtionalists have seemed to be losing ground. As the element of location is a decisive factor for the choice of the legal regime to be applied, a purely functional approach to the regulation of activities in the space above the Earth does not offer a solution. It is therefore to be welcomed that there is clear evidence of a growing recognition of the defect inherent to such an approach and that a spatial approach to the problem is gaining support both by a growing number of States as well as by publicists. The search for a solution of the problem of demarcating the two different legal regimes governing the space above the Earth has undoubtedly been facilitated, and a number of countries, among them Argentina, Belgium, France, Italy and Mexico have already advocated the acceptance of the lower boundary of outer space at a height of 100km. The adoption of the principle of sovereignty at that height does not mean that States would not be allowed to take protective measures against space activities above that height which constitute a threat to their security. A parallel can be drawn with the defence of the State's security on the high seas. Measures taken by States in their own protection on the high seas outside the territorial waters-provided that they are proportionate to the danger-are not considered to infringe the principle of international law. The most important issue in this context relates to the problem of a right of passage for space craft through foreign air space in order to reach outer space. In the reports to former ILA Conferences an explanation was given of the reasons why no customary rule of freedom of passage for aircraft through foreign territorial air space could as yet be said to exist. It was suggested, however, that though the essential elements for the creation of a rule of customary international law allowing such passage were still lacking, developments apperaed to point to a steady growth of a feeling of necessity for such a rule. A definite treaty solution of the demarcation problem would require further study which should be carried out by the UN Outer Space Committee in close co-operation with other interested international organizations, including ICAO. If a limit between air space and outer space were established, air space would automatically come under the regime of the Chicago Convention alone. The use of the word "recognize" in Art. I of chicago convention is an acknowledgement of sovereignty over airspace existing as a general principle of law, the binding force of which exists independently of the Convention. Further it is important to note that the Aricle recognizes this sovereignty, as existing for every state, holding it immaterial whether the state is or is not a contracting state. The functional criteria having been created by reference to either the nature of activity or the nature of the space object, the next hurdle would be to provide methods of verification. With regard to the question of international verification the establishment of an International Satelite Monitoring Agency is required. The path towards the successful delimitation of outer space from territorial space is doubtless narrow and stony but the establishment of a precise legal framework, consonant with the basic principles of international law, for the future activities of states in outer space will, it is still believed, remove a source of potentially dangerous conflicts between states, and furthermore afford some safeguard of the rights and interests of non-space powers which otherwise are likely to be eroded by incipient customs based on at present almost complete freedom of action of the space powers.

  • PDF

The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA (유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상)

  • Choi, In-Ho;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.213-230
    • /
    • 2008
  • The aim of this study was to analyze the initial movement and the stress distribution of each tooth and periodontal ligament during the lingual lever-arm retraction of 6 maxillary incisors using FEA. Two kinds of finite element models were produced: 2-properties model (simple model) and 24-properties model (multi model) according to the material property assignment. The subject was an adult male of 23 years old. The DICOM images through the CT of the patient were converted into the 3D image model of a skull using the Mimics (version 10.11, Materialise's interactive Medical Image Control System, Materialise, Belgium). After series of calculating, remeshing, exporting, importing process and volume mesh process was performed, FEA models were produced. FEA models are consisted of maxilla, maxillary central incisor, lateral incisor, canine, periodontal ligaments and lingual traction arm. The boundary conditions fixed the movements of posterior, sagittal and upper part of the model to the directions of X, Y, Z axis respectively. The model was set to be symmetrical to X axis. Through the center of resistance of maxilla complex, a retraction force of 200g was applied horizontally to the occlusal plane. Under this conditions, the initial movements and stress distributions were evaluated by 3D FEA. In the result, the amount of posterior movement was larger in the multi model than in the simple model as well as the amount of vertically rotation. The pattern of the posterior movement in the central incisors and lateral incisors was controlled tipping movement, and the amount was larger than in the canine. But the amount of root movement of the canine was larger than others. The incisor rotated downwardly and the canines upwardly around contact points of lateral incisor and canine in the both models. The values of stress are similar in the both simple and multi model.