• Title/Summary/Keyword: bed height

Search Result 373, Processing Time 0.029 seconds

Effect of Bed Height on Ginseng Growth and Soil Physical Properties (인삼포 두둑높이가 인삼의 생육 및 토양물리성에 미치는 영향)

  • 이일호;박찬수
    • Journal of Ginseng Research
    • /
    • v.15 no.3
    • /
    • pp.197-199
    • /
    • 1991
  • Growth of ginseng and physical properties of soil were compared with bed height in experimental plots of sand loam for four year and clay loam soil for three year old ginseng plants, respectively. Field survey was also carried out to compare yield and soil physical properties with bed height in the same fold of six years old ginseng fields. High yield of ginseng root was observed at high bed both in the experimental plots and field survey as well. The rate of rusty root was significantly reduced at high bed. Soil porosity increased but soil hardness decreased at high bed.

  • PDF

The Impact on the accuracy of the basic CPR according to position and foot-board height of the basic CPR provider (심폐소생술 제공자의 발판 높이와 자세가 기본심폐소생술의 정확도에 미치는 영향)

  • Choi, Eun-Sook;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.27-41
    • /
    • 2008
  • Purpose : The purpose of this study was to supply basic data for the impact on the accuracy of basic CPR according to position and foot-board height of basic CPR provider. Methods : Study design was within - group design. Subjects were 25 EMT-P Students in K city. Interventions was basic CPR performed on a resuscitation manikin placed on a hospital bed, kneeling on the bed adjacent to the manikin. Data was analyzed using descriptive statistics and Friedman test. Results : In case of the basic CPR performed on a resuscitation manikin placed on a hospital bed, ventilation accuracy was the highest in less than 160 cm height, foot-board height : $34.2{\pm}1.48cm$, 91.4% and in 161-165 cm height, foot-board height : $26.0{\pm}2.14cm$, 88.4% and in 171-175 cm height, foot-board height : $23.0{\pm}1.41cm$, 91.3% and in the above 176 cm, kneeling on the bed, 95%. Chest compression accuracy was the highest in less than 160 cm height, foot-board height : $30.2{\pm}1.48cm$, 95.6% and in 161-165 cm height, kneeling on the bed, 97.6% and in 171-175 cm height, kneeling on the bed, 98.5% and in the above 176 cm, kneeling on the bed, 98.7% and foot-board height : $20.5{\pm}1.91cm$, 98.7%. Chest compression error was due to too weak : 2.0-35.4 times. There were ststistically significant differences in 191-195 cm group according to chest compression mean depths($x^2=10.824$, p = .013) and chest compression error (p = .040). Conclusion : In contrast to current guidelines, the position and foot-board height of basic CPR provider are very important to the accuracy of the basic CPR. Furthermore, we recommend that a using real time audiovisual feedaback system significantly improve the quality of chest compression and ventilation during resuscitation.

  • PDF

Design of a Height Adjustable Bunker Bed Using a Gas Spring (가스 스프링을 이용한 높이조절 벙커침대 설계)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.19-27
    • /
    • 2021
  • A bunker bed is a type of furniture that efficiently utilizes a narrow indoor space by having a high bed and using the empty space below as a living and storage space. The demand for multi-purpose furniture is increasing due to the recent increase in single-person households and wide-spread shared accommodation. According to the consumer research, one of the major drawbacks of a bunker bed was to get on and off the bed through a ladder or stairs. In order to overcome these problems, it was confirmed that the height adjustment function that can easily adjust the minimum and maximum heights of the bed was necessary. In this study, a height adjustable bunker bed was designed by using a gas spring that generates a repulsive force by the compressed gas inside. The design process consisted of the following three steps: Firstly, the hysteresis characteristics due to a friction and spring constant of a commercial gas spring were confirmed by measuring the repulsive force vs. compressed displacement. Secondly, requirements of the vertical lifting force exerted on the bed against gravity force were derived. Finally, the height-adjustable bed using the four-bar link mechanism was designed with 4 parameters so that the bed weight of 60-70 kgf could be adjusted to 800 mm in height by an affordable initial operation force. The performance was verified through prototype production and the results of vertical displacement and force to move were nearly the same as designed. In addition, an electrically operated height-adjustable bed was also designed with linear actuators and the performance was proved with the prototype.

Uncertainty in the Measurement of Radiative Energy Attenuation through Packed Spheres (구립자층내의 복사에너지 감쇠량계측의 불확정성에 관한 연구)

  • 김춘식;김경근;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.5
    • /
    • pp.23-29
    • /
    • 1991
  • Uncertainty is studied in the measurements of average packing density, thickness of packed spheres and transmittance in the experiments to study the effect of the bed height and the existence of the bed side walls on the transmittance of radiative energy through packed spheres. The packing density of the bed is obtained by counting the number of the spheres packed in three pipes with different heights. The bed height of the packed spheres is estimated from the number of spheres contained in the bed by using the relation between the bed height and the sphere number. The transmittance is obtained by dividing the intensity of the transmitted laser beam by the incoming-beam intensity. From the analysis, the uncertainity in the measurements of transmittance is shown to be less than 10.2%(95% coverage).

  • PDF

Effect of Lower Bed Height on Collapse Velocity in the Two-Stage Bubbling Fluidized-Bed with a Standpipe for Solid Transport (고체 수송관이 있는 2 단 기포 유동층에서 붕괴 속도에 대한 하단 층 높이의 영향)

  • Khurram, Muhammad Shahzad;Choi, Jeong-Hoo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.864-870
    • /
    • 2018
  • The effect of lower bed height on the collapse velocity was investigated for a two-stage bubbling fluidizedbed (0.1 m in diameter, 1.2 m high) connected with a standpipe (0.025 m in diameter) for solid transport. Air was used as fluidizing gas and mixture of coarse (< $1000{\mu}m$ in diameter and $3625kg/m^3$ in apparent density) and fine (< $147{\mu}m$ in diameter and $4079kg/m^3$ in apparent density) particles as solid particles. Mixing ratio of fine particles, height of the lower bed and the distributor of the upper bed were considered as experimental variables. The collapse velocity increased with static height of the lower bed. However, the effect decreased as the mixing ratio of fine particles increased. The effect seemed to be attributed to the increase in height of the dense layer of coarse particles that prevented the gas from flowing into the standpipe, not in pressure drop for the standpipe, as the bed height increased. The collapse velocity decreased a little as the pressure drop of the distributor of the upper bed increased. An improved correlation was proposed for predicting the collapse velocity.

Anthropometric and Standing Action Analysis for Electric Adjustable Bed (전동침대의 인체측정학적 분석과 높이에 따른 기립 동작의 기초 연구)

  • Kang, Byeong-Ki;Jung, Kwang-Tae;Chun, Keyoung-Jin;Won, Byeong-Hee;Hong, Jae-Soo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.125-137
    • /
    • 2009
  • Recently, the frequency in use of electric adjustable bed is going up by an increase in the elderly population. In bad ergonomic design for an electric adjustable bed causes some problems in the aspects of usability and safety. In particular, lots of accidents came from going up or going down an electric adjustable bed. In that case, the height of bed is very important factor for preventing an accident. This problem is related to its anthropometric factors. Therefore we carried out its anthropometric analysis and old people's standing action according the height of electric adjustable bed as an experimental study. As a result, we proposed some anthropometric design criteria and identified the effect of bed height when old people use it.

Influence of an in-vessel debris bed on the heat load to a reactor vessel under an IVR condition

  • Joon-Soo Park;Hae-Kyun Park;Bum-Jin Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.180-189
    • /
    • 2023
  • We measured the heat load to a reactor vessel with and without the in-vessel debris bed under an IVR-ERVC condition. Mass transfer methodology was adopted based on heat and mass transfer analogy to achieve high Ra'H of order ~1015 with compact test rigs. We postulated the in-vessel debris bed has a flat top and particulate debris was simulated as an identical diameter spheres. We conducted experiments varying the height of the debris bed and the results showed that Nusselt numbers decreased in both uppermost and curved surfaces with the increasing bed height. Once the debris bed is formed, it acts as an obstacle to the natural convective flow, which reduces the buoyancy. The reduction of driving force results in the impaired heat transfer in both upward and downward heat transfers.

Study on Flame Height Equation for the Pinus densiflora Surface Fuel Bed (소나무 낙엽층 화염높이 산정식에 관한 연구)

  • Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.10-15
    • /
    • 2009
  • Flame height calculation in a forest fire is a crucial part of predicting horizontal or vertical flame spread flared by radiation heat transfer. Flame height, which is one of the flame characteristics, can be estimated by the average height of luminous flame. This research relied on flame height observation test on P. densiflora surface fuel bed, which are surface combustibles in a forest, and calorimeter to measure Heat Release Rate, thus produced $H_f=0.027(\dot{Q'})^{2/3}$, flame height calculation equation for surface fuel. The research did not take into consideration such conditions as external velocity, slope and other variables that could affect flame height. According to comparison among experiment results, calculation results of the above formula and those of existing Heskestad formula (1998), it was found that standard error in fallen pine needles between experimental results and calculation results of the above formula amounts to 0.08, whereas standard error in same plant between experimental results and calculation results of existing Heskestad formula amounts to 0.23.

Experimental Study on the Stability of Dredged Soil Bed under Cyclic Wave Actions (파랑작용에 의한 준설토 지반의 안정성에 관한 실험적 연구)

  • Kang, Yoon-Koo
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.4 s.71
    • /
    • pp.43-49
    • /
    • 2006
  • Detailed investigations were carried out on the stability of the dredged soil bed against wave actions, aimedat establishing the design method of artificial tidal flats using dredged soil. The soil was dredged at Nagoya port, Japan, and has a mean grain size of 0.013mm. Basic features of artificial dredged soil bed against wave actions were explained from a series of model experiments in a wave flume. The two types of section shapes were employed; one is a horizontal bed and the other is a sloped one. Changes of the bed profile, shear strength, grain size distribution and water content, according to the wave actions, were measured in detail. The cumulative effect of the wave actions, over about one week, was investigated. A dredged soil bed moves withthe wave actions with relatively small wave height. It should be especially. noted that the clay component is dissolved and flown out, away from the surface layer, and consequently the surface layer hardens, as if it is covered with sand. Wren the wave height is gradually increased, the bed is not liquefied and the shear strength of the dredged bed is increased by a wave-induced dissipation of pore pressures in the bed and a decrease of clay component by the wave-induced leakage.

A Study on the Optimal Design in the Indirect Aerated Fluidized Bed (간접 포기식 유동상의 이상적 설계에 관한 연구)

  • 안송엽;김환홍;권희태
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.95-100
    • /
    • 1999
  • Process intensification without any increase in bed requires the exploitation of fluid mechanical phenomena as the basis for elegant solutions to the process engineering problems which result from the need to retain and control the immobilized biomass, and for biomass recovery. The fluidized bed biological reactor provides a solution to these needs. The wastewater treatment characteristics of the fluidized bed was filled with sand media. Indirect aeration were studied experimentally. The researcher was filled with sand particle size(0.60~0.42mm) in three reactors with different section area(A)/height(H), in the state BOD loading 4.5kg-$BOD_5/m^3$ㆍd, and under the fixed state of hydraulic retention time for around 32 minutes.

  • PDF