• Title/Summary/Keyword: beam test

Search Result 2,922, Processing Time 0.025 seconds

An experimental method to determine glass elastic modulus based on the fundamental frequency of the elastic support-free end beam

  • Kun Jiang;Danguang Pan
    • Structural Engineering and Mechanics
    • /
    • v.88 no.2
    • /
    • pp.189-200
    • /
    • 2023
  • Silicate glass is usually a brittle and plate-like material, and it is difficult to measure the elastic modulus by the traditional method. This paper develops a test method for the glass elastic modulus based on the fundamental frequency of the cantilever beam with an elastic support and a free end. The method installs the beam-type specimen on a semi-rigid support to form an elastic support-free end beam. The analytic solution of the stiffness coefficients of the elastic support is developed by the fundamental frequency of the two specimens with known elastic modulus. Then, the glass elastic modulus is measured by the fundamental frequency of the specimens. The method significantly improves the measurement accuracy and is suitable for the elastic modulus with the beam-type specimen whether the glass is homogeneous or not. Several tests on the elastic modulus measurement are conducted to demonstrate the reliability and validity of the test method.

Proposed Test Method for Verification of Survivability Improvement of KASS Augmented Navigation of a Beam-formed GPS Receiver (빔포밍 GPS 위성항법장치의 KASS 보정항법 생존성 향상을 검증하기 위한 시험평가 방법 제안)

  • Junwoo Jung;Hyunhee Won;Daeyoung Park;Seungmin Kang;Jonggyu Go;Seungbok Kwon;Kwi Woo Park;Bongwoo Jo;Woogeun Ahn;Sung Wook Yun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.3
    • /
    • pp.257-268
    • /
    • 2024
  • The Korea Augmentation Satellite System (KASS) satellite was successfully launched and service is being started. By receiving messages transmitted from the KASS satellite, users can employ the messages to improve positioning accuracy or to verify the integrity of Global Positioning System (GPS). In this paper, we propose a test method for a beam-formed GPS receiver developed to improve the survivability of KASS augmented messages that can enhance positioning accuracy even in an environment with jamming or interfering signals. Through the test method proposed in this paper, quantitative verification is performed for a beam-formed GPS receiver aimed at maintaining the augmented navigation solution to which KASS augmented messages are applied by tracking the KASS signal as much as possible under conditions where the jamming signal strength is gradually increasing. In addition, the proposed test method includes three conditions; first, a static lab test method for repeated verification of functions under the same conditions; second, a static outdoor test method for performance verification in an operating environment of a platform equipped with the beam-formed GPS receiver; and finally, a dynamic lab test method for performance verification of a moving platform equipped with the beam-formed GPS receiver toward a jammer. In this paper, we propose a method for simulating the jamming signal incident direction through the phase delay of an RF cable designed to prevent unintentional jamming signal emission in both lab and outdoor tests, and a method of applying test software for injecting a jamming signal to compare the survivability performance consistently according to the presence or absence of beamforming signal processing. Through the proposed test method, it was verified that the augmented navigation solution could be output for a longer time period when the beamforming signal processing was applied to the KASS satellite signal in the beam-formed GPS receiver.

An Analytic Method for the Residual Strength Evaluation of Fire-Damaged Reinforced Concrete Beam

  • Park, Won-jun;Park, Ki-bong;Lee, Han-seung
    • Architectural research
    • /
    • v.10 no.2
    • /
    • pp.37-42
    • /
    • 2008
  • This study is to get the proper evaluation of the residual property of reinforced concrete beam exposed to fire. This study focused on the strength resistance and analytical evaluation of RC members exposed high temperature. And this study is the basis analytical research to conduct the other studies. To analysis by the finite element method, the Total-RC program was used to analysis it and the Total-Temp program was also used to analysis the temperature distributions at the section. All of results were compared with the pre-existing experimental data of simple supported beam. Using it, the parameters influencing the structural capacity of the high temperature-damaged RC members and residual strength estimation are investigated. The temperature distribution and the structural capacity at the section are calculated in this step. An application of this method is compared with the heating test result and residual property test for simple supported beam which is subjected to ISO 834 test fire. The results of this study are as follows; 1) The loads-displacement relationship of RC beam, considering initial thermal stress of cross section and heat transfer analysis are estimated comparing analytical value with pre-existing experimental results. 2) by the heating time (0, 1, 2 hours), the results of analysis with parameters show that the load capacity exposing at fire is affected.

Experimental investigation on the seismic behavior of reinforced concrete column-steel beam subassemblies

  • Xiong, Liquan;Men, Jinjie;Ren, Ruyue;Lei, Mengke
    • Steel and Composite Structures
    • /
    • v.28 no.4
    • /
    • pp.471-482
    • /
    • 2018
  • The composite reinforced concrete and steel (RCS) structural systems have larger structural lateral stiffness, higher inherent structural damping, and faster construction speed than either traditional reinforcement concrete or steel structures. In this paper, four RCS subassemblies with or without the RC slab designed following a strong column-weak beam philosophy were constructed and tested under reversed-cyclic loading. Parameters including the width of slab and composite effect of the RC slab and beam were explored. The test results showed that all specimens performed in a ductile manner with plastic hinges formed in the beam ends near the column faces. The seismic responses of composite connections are influenced significantly by different width of slabs. Compared with that of the steel beam without the RC slab, it was found that the load carrying capacity of composite connections with the RC slab increased by 30% on average, and strength degradation, energy dissipation also had better performance, while the ductility of that were almost the same. Furthermore, the contribution of connection deformation to the overall specimen displacement was analyzed and compared. It decreased approximately 10% due to the coupling effect in the columns and beams with the RC slab. Based on the test result, some suggestions are presented for the design of composite RCS joints.

Strain penetration of high-strength steel bars anchored in reinforced concrete beam-column connections

  • Li, Ling;Zheng, Wenzhong;Wang, Ying
    • Structural Engineering and Mechanics
    • /
    • v.72 no.3
    • /
    • pp.367-382
    • /
    • 2019
  • This paper presents experimental and analytical investigations on additional fixed-end rotations resulting from the strain penetration of high-strength reinforcement in reinforced concrete (RC) beam-column connections under monotonic loading. The experimental part included the test of 18 interior beam-column connections with straight long steel bars and 24 exterior beam-column connections with hooked and headed steel bars. Rebar strains along the anchorage length were recorded at the yielding and ultimate states. Furthermore, a numerical program was developed to study the effect of strain penetration in beam-column connections. The numerical results showed good agreement with the test results. Finally, 87 simulated specimens were designed with various parameters based on the test specimens. The effect of concrete compressive strength ($f_c$), yield strength ($f_y$), diameter ($d_b$), and anchorage length ($l_{ah}$) of the reinforcement in the beam-column connection was examined through a parametric study. The results indicated that additional fixed-end rotations increased with a decrease in $f_c$ and an increase in $f_y$, $d_b$ and $l_{ah}$. Moreover, the growth rate of additional fixed-end rotations at the yielding state was faster than that at the ultimate state when high-strength steel bars were used.

Flexural behavior of reinforced lightweight concrete beams under reversed cyclic loading

  • Chien, Li-Kai;Kuo, Yi-Hao;Huang, Chung-Ho;Chen, How-Ji;Cheng, Ping-Hu
    • Structural Engineering and Mechanics
    • /
    • v.52 no.3
    • /
    • pp.559-572
    • /
    • 2014
  • This paper presents the results of an experimental investigation on the flexural behavior of doubly reinforced lightweight concrete (R.L.C.) beams tested under cyclic loading. A total of 20 beam specimens were tested. Test results are presented in terms of ductility index, the degradation of strength and stiffness, and energy dissipation. The flexural properties of R.L.C. beam were compared to those of normal concrete (R.C.) beams. Test results show that R.L.C. beam with low and medium concrete strength (20, 40MPa) performed displacement ductility similar to the R.C. beam. The ductility can be improved by enhancing the concrete strength or decreasing the tension reinforcement ratio. Using lightweight aggregate in concrete is advantageous to the dynamic stiffness of R.L.C. beam. Enhancement of concrete strength and increase of reinforcement ratio will lead to increase of the stiffness degradation of beam. The energy dissipation of R.L.C beam, similar to R.C. beam, increase with the increase of tension reinforcement ratio. The energy dissipation of unit load cycle for smaller tension reinforcement ratio is relatively less than that of beam with higher reinforcement ratio.

Experimental Evalution of Structural Behavior on SRC type TEC-BEAM to RC Column Connection (SRC형 TEC-BEAM과 RC기둥 접합부 구조적 거동의 실험적 평가)

  • Ju, Young Kyu;Kim, Do Hyun;Chung, Kwang Ryang;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.3
    • /
    • pp.463-470
    • /
    • 2002
  • The TEC-Beam system is a composite beam consisting of structural tee, precast concrete, and cast-in-site reinforced concrete slab. The preliminary test of the proposed system was performed for simple beams, showing good behavior. However, for the field application of the system. TEC-Beam - RC column connection was required to produce a mechanism that transfers the force occurring in the lower part of the TEC-Beam. Thus, this study developed a connection mechanism that transfers the force occurring in the lower part of the TEC-Beam. Thus, this study developed a connection wherein the section of the TEC-Beam was enlarged and the lower part reinforced. Two setups of the proposed system were experimentally investigated. using the anchorage length of reinforcement., i.e., length of the increased section, as test parameter. It could be concluded from the result that the proposed system shows good structural behavior, with potential applicability in the field.

A Study on the Near-Field Simulation Method for AESA RADAR using a Single Beam-Focusing LUT (단일 빔 집속 LUT를 이용한 AESA 레이다의 근전계 시뮬레이션 기법)

  • Ju, Hye Sun
    • Journal of the Korea Society for Simulation
    • /
    • v.28 no.2
    • /
    • pp.81-88
    • /
    • 2019
  • Since the AESA radar scans and tracks a distant targets or ground, it requires a test field which meets far-field condition before flight test. In order to test beam foaming, targeting, and availability from cluttering and jamming, it is general to build a outdoor roof-lab test site at tens of meters high. However, the site is affected by surrounding terrain, weather, and noise wave and is also requires time, space, and a lot of costs. In order to solve this problem, theoretical near-field beam foaming method has proposed. However, it requires modification of associated hardware in order to construct near-field test configuration. In this paper, we propose near-field beam foaming method which use single LUT in order to calibrate the variation of TRM(transmit-receive module) which consists AESA radar without modification of associated hardware and software. It requires less costs than far-field test and multiple LUT based near-field test, nevertheless it can derives similar experimental results.

Analysis on Application of Limit State Design Method for Bridge Evaluation Considering PSC Beam Bridge Experiment Results (PSC Beam교의 실측실험을 반영한 한계상태설계법 기반 교량 평가법 적용 분석)

  • Kim, Kyunghyun;Yoo, Minsun;Paik, Inyeol;Shin, Soobong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.235-244
    • /
    • 2021
  • This study analyzes the applicability of limit state design method on bridge evaluation by considering the experiment of the existing bridge. The test strength of the member is obtained from the PSC beam bridge experiment. The test strength is compared with the calculated strength obtained from the statistical characteristics of material test strength and the two values are almost the same. The response modification factor and dynamic impact factor are obtained from the vehicle loading test. The rating factor is calculated by applying limit state design method as well as current evaluation method and the results are compared. The reliability index of the test bridge is calculated by using the statistical properties of the member strength obtained from material test and simulation. When the statistical properties of the PSC beam tested in this study are applied, the reliability index with a larger value was obtained than the reliability index obtained with the statistical properties of the design code.

Transport of space charge between sub-pixels in AC-plasma cell discharge

  • Lee, S.B.;Park, E.Y.;Han, Y.G.;Moon, M.W.;Oh, P.Y.;Song, K.B.;Lee, H.J.;Son, C.G.;Jeong, S.H.;Yoo, N.L.;Hong, Y.J.;Jeong, S.J.;Kim, J.H.;Park, S.O.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.929-931
    • /
    • 2006
  • In this experiment, we have investigated that the transported space charge between sub-pixels in AC-plasma cell discharge. The test pulse 30 V, $5{\mu}s$ was applied to the address electrodes of neighbor cells of discharge occurred cells. And we have measured the transported space charge between sub-pixels in accordance with the various last sustain pulse widths t(time gap between the rising edges of sustain and test pulses) of 0.2 to $3{\mu}s$. It was observed that the peak value of transported space charge has been shown to be 21.5pC at $1.0{\mu}s$. And the IR peak value have been occured after $0.51{\mu}s$ with respect to sustain voltage.

  • PDF