• Title/Summary/Keyword: beam splice

Search Result 66, Processing Time 0.024 seconds

Structural Performance Evaluation of Slab-Beam-Column Subassemblage in R/C Ordinary Moment Frame Building (철근콘크리트 보통모멘트 골조의 슬래브-보-기둥 부재의 구조성능 평가)

  • 유혁상;한상환;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.757-762
    • /
    • 2000
  • The purpose of this study is to investigate the performance of slab-beam-column subassemblage in the Ordinary Moment Frame(OMF). For this purpose, 3-story building was designed according to UBC and ACI building code(ACI 318-99) and the subassemblages of in the first story were constructed. The subassemblages were classified into interior and exterior. Each interior and exterior subassemblage is modeled by the 2/3 scale experimental specimens. All the specimens have the transverse beam and the columns on the slab have the lap splice as the typical exterior and interior slab-beam-column subassemblage. The interior subassemblage was tested under the constant axial force, while the exterior subassemblage was tested under the fluctuating axial force. Based on the results of the experiments, the performance of each subassemblage is evaluated and the failure mode is investigated.

  • PDF

Experimental Study on Effect of Confinement Details for Lap Splice of Headed Deformed Reinforcing Bars in Grade SD400 and SD500 (구속상세가 SD400 및 SD500 확대머리 이형철근의 겹침이음에 미치는 영향에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.62-71
    • /
    • 2015
  • KCI 2012 and ACI318-11 contains development length provisions for the use of headed deformed bars in tension and does not allow their tension lap splices. In ACI318-11, the confinement factor, such as transverse reinforcement factor, is not used to calculate the development length of headed bars. The purpose of this experimental study is to evaluate the effect of confinement details to the lap splice performance of headed deformed reinforcing bars in grade SD400 and SD500. The confinement details are stirrups and tie-down bars in lap zone. Test results showed that specimens with only stirrups had the brittle failure and could not increase lap strengths, and that specimens with composite confinements by stirrups and tie-down bars had the flexural strengths over than nominal flexural strengths. Stirrups with tie-down bars can have an effect on improvement in lap splice of headed bars in grade SD400 and SD500.

A Study on the Structural Methods between Purlin and Beam at Wooden Architecture in Joseon Dynasty (조선시대 목조건축 도리와 보의 결구방법에 관한 연구)

  • Jung, Yun-Sang
    • Journal of architectural history
    • /
    • v.16 no.6
    • /
    • pp.87-100
    • /
    • 2007
  • This study examines on the structural Methods between purlin and beam at Wooden Architecture in Joseon Dynasty($1372{\sim}1910$). Through the investigation, it is verified that the structural methods between purlin and beam is the technique utilizing tenon joint(통장부맞춤), Sungeoteok joint(숭어턱맞춤), dovetailed tenon joint(주먹장맞춤). And the methods of tenon joint is followed by the Sungeoteok joint, which is used in the buildings after middle Joseon dynasty. The method of tenon joint(통장부맞춤) is to connect the beam with the purlin by carving out the head of the beam as '一' shape. And the structural methods between Janghyeo(장혀, timber under purlin) and beam is halved joint(반턱맞춤) and tenon joint (통장부맞춤). The buildings in late Goryeo Dynasty and Joseon Dynasty adopted the method of tenon joint between purlin and beam. The method of Sungeoteok joint is to connect the beam with the purlins by carving out the head of the beams '凸' shape. And the structural methods between Janghyeo and beams is halved joint(반턱맞춤) and tenon joint(통장부맞춤), the method of tenon and step joint(통장부턱맞춤), dovetailed joint between beam and Janghyeo to increase the security of shear force.

  • PDF

Tension Lap Splice Length in High-Strength Concrete Flexural Members (고강도 콘크리트 휨부재의 인장 겹침이음길이에 관한 연구)

  • Lee, Gi-Yeol;Kim, Woo;Lee, Hwa-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.753-761
    • /
    • 2009
  • This paper presents the test results of total 24 beam-end specimens to investigate the effect of high-strength concrete and cover thickness on the development resistance capacity in tensile lap splice length regions. Based on bond characteristics that an increase in concrete strength results in higher bond stress and shortening of the transfer length, cracking behavior that thin cover thickness induced a splitting crack easily and brittle crack propagation, current design code that development length provisions as uniform bond stress assumption was investigated apply as it. The results showed that as higher strength concrete was employed, not only development resistance capacity was influenced by cover thickness, but also more sufficient safety factor reserved shorter than the lap splice length provision in current design code. From experimental research results, high-strength concrete development length was not inverse ratio of $\sqrt{f_{ck}}$ but directly inverse of $f_{ck}$, and it is also said that there is a certain limit length of the embedded steel over which the assumption of uniform bond stress distribution is valid specially for high-strength concrete not having a same embed length such as normal-strength concrete in current design criteria hypothesis.

Shear Behaviour of Precast Concrete Modular Beam Using Connecting Plate (연결 플레이트를 사용한 프리캐스트 콘크리트 모듈러 보의 전단성능)

  • Cho, Chang Geun;Ro, Kyong Min;Lee, Young Hak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.4
    • /
    • pp.65-72
    • /
    • 2021
  • The Precast concrete(PC) modular structures are a method of assembling pre-fabricated unit modules in the construction site. The essential aim of modular structures is to introduce a connection method that can ensure splicing performance and effectively resist shear strength. This study proposed PC module using a connecting plate that can replace splice sleeves and shear keys used in the conventional PC modular structures. To evaluate the splicing performance and shear capacity of the proposed method, the shear test was conducted by fabricating one monolithic reinforced concrete(RC) beam and two PC modular beams with a shear span-to-depth ratio as variables. The experimental results showed that the shear capacity of the PC modular beam was about 89% compared to that of the RC beam, and showed a failure of the RC beam according to the shear span-to-depth ratio. Therefore, it was considered that the connecting plate effectively transferred the stress between each PC module through the joint and ensure integrity. In addition, the applicability of shear strength equation of ACI 318-19 and Zsutty's equation to PC modular beams were evaluated. Results demonstrated that the improved shear strength equations are needed to consider reduction of shear strength in PC modules.

Experimental evaluation of splicing of longitudinal bars with forging welding in flexural reinforced concrete beams

  • Sharbatdar, Mohammad K.;Jafari, Omid Mohammadi;Karimi, Mohammad S.
    • Advances in concrete construction
    • /
    • v.6 no.5
    • /
    • pp.509-525
    • /
    • 2018
  • In this paper the application of forging process as benefit technique in Reinforced Concrete (RC) beam bars and comparison to lap splices was experimentally investigated with four concrete beam specimens with same dimensions and reinforcement details. The reference specimen was with no splices and the other three beams were with different splices (100% forging in the middle, 50% forging, and 100% lap splices in the middle). Beams were tested with the four points load system. Experimental test results indicated that using forging process as new bar splicing method can have high effects on increasing ductility and energy dissipation of concrete structures. It also proved that this method increased the flexural rigidity, energy absorption, and ductility of the RC beams. And also this research results showed that the flexural capacity and ductility of the beam with 50% forging were respectively increased up to 10% and 75% comparing to that of reference specimen, but the energy absorption of this beams was decreased up to 27%. The ductility of beam with 50% forging was increased up to 25% comparing the ductility of beam with 100% forging.

Modeling Parameters for Column-Tree Type Steel Beam-Column Connections (컬럼-트리 형식 철골모멘트 접합부의 모델링 변수제안)

  • An, Heetae;Kim, Taewan;Yu, Eunjong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.59-68
    • /
    • 2023
  • The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.

Lapped Splices in High-Strength Concrete Flexural Members (고강도 콘크리트 휨 부재의 철근 겹이음에 대한 연구)

  • Kim, Woo;Kim, Jun-Seong;Kim, Dae-Joong;Son, Young-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.447-452
    • /
    • 1996
  • An experimental study was conducted to evaluate the bond performance of reinforcing bars embedded in high-strength concrete. Ten beam spice Specimens using concrete with compressive strength of 240kg/$\textrm{cm}^2$ and 640kg/$\textrm{cm}^2$ were tested. The effect of several variables on basic development length is discussed. The test results showed that the current trend in concrete specification of making the splice length longer to compensate for having smaller cover and spacing may not be an effective approach.

  • PDF

Applicability of Current Design Code to Class B Splice of SD600 Re-Bars (SD600 철근의 B급 겹침 이음에 대한 현행설계기준의 적용성)

  • Choi, Won-Seok;Chung, Lan;Kim, Jin-Keun;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.449-459
    • /
    • 2011
  • An experimental study was performed to evaluate the applicability of current design code to the class B splice of SD600 reinforcing bars. Twelve simply supported beam and slab specimens with re-bar splices were tested under monotonic loading. Parameters for this test were re-bar diameter, concrete cover thickness, concrete strength, and stirrup spacing. Concrete strengths ranged 24.7~55.3 MPa. Most of the specimens were designed to satisfy the class B splice length specified by current design code. Average bar stresses resulting from this test were compared with the predictions by the KCI code provisions. Based on the result, the applicability of the current design code to SD600 re-bars were evaluated. The re-bar splices gave satisfactory performance for all D13 re-bar splices and for D22 and D32 splices with transverse reinforcement. On the basis of the test result, for D22 and the greater diameter bars, the use of either transverse reinforcement of the thicker concrete cover was recommended.

Experimental Study on Lap Splice of Headed Deformed Reinforcing Bars in Tension (인장력을 받는 확대머리 이형철근의 겹침이음에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.59-67
    • /
    • 2014
  • In tension lap splices of straight deformed bars, KCI Code (KCI2012) and ACI Code (ACI318-11) requires that the lap lengths for class B splice are 1.3 times as development length. KCI2012 contains development length provisions for the use of headed deformed bars in tension and does not allow their tension lap splices. The purpose of this experimental study is to evaluate that KCI2012 equation for the development length, $l_{dt}$, of headed bars can be used to calculate the lap length, $l_s$, of headed deformed bars in grade SD400 and SD500, having specified yield strength of 400 and 500 MPa. Test results showed that specimens with $l_s$ equal to $1.3l_{dt}$ had maximum flexural strengths as 1.16~1.31 times as the nominal flexural strengths, flexural failure mode, and ductility. These observations indicate that $1.3l_{dt}$ is suitable to the tensile lap length of headed deformed bars in grade SD400 and SD500.