• Title/Summary/Keyword: base leakage

Search Result 161, Processing Time 0.024 seconds

Joint Transmitter and Receiver Design Based on SPPLNR for Multi-user MIMO Channel with Channel Estimation Error (채널 추정 오차가 있는 다중사용자 다중안테나 채널에서 신호 대 포스트-프로세싱 리키지 및 잡음비 기반 송신기와 수신기 결합 설계)

  • Seo, Dong-Joon;Lee, Pan-Hyung;Lee, Jae-Hong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.2
    • /
    • pp.53-59
    • /
    • 2009
  • In multi-user MIMO systems, a base station transmits multiple data to multi-user simultaneously in order to improve performance and bandwidth efficiency. When the base station transmits multiple data to multi-user simultaneously, multi-user interference occurs severely. In this paper, we define a post-processing leakage as the total power leaked from desired user to all other users after combining at the output of each user. Using concept of the post-processing leakage, we also define a performance metric, the so called signal-to-post-processing-leakage-plus-noise ratio (SPPLNR). Assuming that the receiver is the minimum mean square error (MMSE) receiver, we propose an iterative SPPLNR-based beamforming that determines beamforming vectors and combining vectors by using an iterative method. The proposed scheme does not impose a condition on the relation between the number of transmit antennas for the base station and the number of receive antennas for users. Simulation results show that the proposed scheme outperforms a beamforming scheme perfectly eliminating the multi-user interference when channel estimation error exists.

Degradation of the SiGe hetero-junction bipolar transistor in SiGe BiCMOS process (실리콘-게르마늄 바이시모스 공정에서의 실리콘-게르마늄 이종접합 바이폴라 트랜지스터 열화 현상)

  • Kim Sang-Hoon;Lee Seung-Yun;Park Chan-Woo;Kang Jin-Young
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.1
    • /
    • pp.29-34
    • /
    • 2005
  • The degradation of the SiGe hetero-junction bipolar transistor(HBT) properties in SiGe BiCMOS process was investigated in this paper. The SiGe HBT prepaired by SiGe BiCMOS process, unlike the conventional one, showed the degraded DC characteristics such as the decreased Early voltage, the decreased collector-emitter breakdown voltage, and the highly increased base leakage current. Also, the cutoff frequency(f/sub T/) and the maximum oscillation frequency(f/sub max/) representing the AC characteristics are reduced to below 50%. These deteriorations are originated from the change of the locations of emitter-base and collector-base junctions, which is induced by the variation of the doping profile of boron in the SiGe base due to the high-temperature source-drain annealing. In the result, the junctions pushed out of SiGe region caused the parastic barrier formation and the current gain decrease on the SiGe HBT device.

A Study on Measures for Preventing Personal Information Leakage in Financial Corporations (금융사 개인정보 유출 방지 방안에 관한 연구)

  • Jeong, Gi Seog
    • Convergence Security Journal
    • /
    • v.14 no.4
    • /
    • pp.109-116
    • /
    • 2014
  • Personal information leakage in financial corporations including three card corporations has occurred constantly this year. It is due to incomplete encryption system and negligent personal security. Solicitors are known as a cause of information leakage because they operate with leaked information. Information leakage can cause secondary damage with mental demage to person and result in a drop in reliability as well as an operating loss in financial corporations. Also because it can destroy a base of credit society, prevention of recurrence is badly needed. The government finally announced 'general measures for prevention of information leakage in the field of finance' with sanctions reinforcement and restriction to collect, possess, provide personal information as the main agenda. And a related law revision is going in the National Assembly. In this paper, effectiveness of government measures is weighed with the cause analysis of information leakage and countermeasure for prevention of information leakage is found.

Information Network Usage Plan for the Quality Control of Leakage Prevention (누수예방을 위한 품질확보 관련 정보공유시스템의 활용방안의 관한 연구)

  • Kang, Hyo-Jin;An, Ki-Won;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.217-218
    • /
    • 2017
  • Residential apartment underground structures are being utilized for many purposes such as parking lots, community centers, fitness centers, etc. for efficient use of space. However, there are increasing problems of leakage due to various environmental and deterioration conditions. This paper proposes the development of an information network system which can serve as a base to provide solutions, alternatives and technical information for leakage prevention and effective design at the beginning of the construction stage.

  • PDF

AN EXPERIMENTAL STUDY ON THE MEASUREMENT OF MARGINAL LEAKAGE USING A NEUTRON ACTIVATION ANALYSIS (Neutron Activation Analysis를 이용한 Composite Resin의 변연누출 측정에 관한 실험적 연구)

  • Kim, Mi-Ja;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.185-190
    • /
    • 1988
  • The study was designed to establish quantitative method for assessing the marginal leakage of dental restorations. 18 Class V cavities with $45^{\circ}$ bevel joint were prepared and replicas of these teeth were made with polyethylene wax. and classified with three groups. First group was filled with Scotch bond and silux. Second group was filled with glass ionomer cement:scotchbond/silux. Third group was filled with Dentin-Adhesit/Heliosit. After finishing, all specimens were subjected manually to 100 thermal cycles at $0^{\circ}C$ and $100^{\circ}C$ Samarium nitrate solution, irradiated with flux of $6{\times}12^{12}$ neutrons/$cm^2$/sec for 11 hours, woled for 200 hours, counted with the HpGe detector and the tracer uptake was determined by comparison with a standard of samarium ($10{\mu}g$). The following results were obtained. 1) The group filled with glass ionomer cement base showed least marginal leakage. 2) The group filled with Dentin-Adhesit/Heliosit showed less marginal leakage than the group filled with scotchbond/silux.

  • PDF

Gluteus Maximus Muscle Flap in Tongue in Groove and Wrap Around Pattern for Refractory CSF Leakage in Extradural Cyst Patient

  • Park, Kyong Chan;Lee, Jun Ho;Shim, Jae Jun;Lee, Hyun Ju;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.365-368
    • /
    • 2022
  • Spinal extradural arachnoid cyst (SEAC) is a rare disease and has surgical challenges because of the critical surrounding anatomy. We describe the rare case of a 58-year-old woman who underwent extradural cyst total excision with dural repair and presented with refractory cerebrospinal fluid (CSF) leakage even though two consecutive surgeries including dural defect re-repair and lumbar-peritoneal shunt were performed. The authors covered the sacral defect using bilateral gluteus maximus muscle flap in tongue in groove and wrap around pattern for protection of visible sacral nerve roots and blockage of CSF leakage point. With the flap coverage, the disappearance of cyst and fluid collection was confirmed in the postoperative radiological finding, and the clinical symptoms were significantly improved. By protecting the sacral nerve roots and covering the base of sacral defect, we can minimize the risk of complication and resolve the refractory fluid collection. Our results suggest that the gluteus muscle flap can be a safe and effective option for sacral defect and CSF leakage in extradural cyst or other conditions.

Usefulness of Bipedicle Temporalis-pericranial Flap for Closure of Frontoethmoidal Encephalomeningoceles (전두사골 뇌수막류의 폐쇄를 위한 양경 측두근골막피판의 유용성)

  • Yun, Byung Min
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.97-102
    • /
    • 2009
  • Purpose: To close anterior cranial base, various types of pedicle flaps have been developed previously. However, the results of those pedicle flaps were not constant. To solve such problem, the author designed bipedicle temporalis-pericranial (BTP) flap based on various types of existing flaps and this study intends to introduce this flap and present clinical application case. Methods: The pedicle of the proposed temporalis-pericranial flap is temporalis muscle. The point of this BTP flap is that because of both sides of the unilateral temporalis-pericranial flap are connected by midline pericranial tissue connected with dense vascular network communicate one another locally, that BTP flap can be safely elevated. The case is a 14 months old male patient of frontoethmoidal encephalomeningocele. Surgery was done in a way that after elevating BTP flap and removing encephalomeningocele, BTP flap was moved intracranially, and to prevent cerebrospinal fluid leakage, anterior cranial base was closed. Results: During 1 year and 6 month outpatient tracking observation, no particular finding like CSF leakage, meningitis or hydrocephalus was observed. Conclusion: The benchmarked BTP flap, effective in the treatment of frontoethmoidal encephalomeningocele, is one of the methods to close intracranium and extracranium.

Method of Measuring the Occupied Bandwidth of IS-95 Base Station at Remote Site

  • Lim, Jong-Soo;Kim, Sang-Tae
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.7-11
    • /
    • 2003
  • CDMA(code division multiple access) has very large peak to average power ratio(PAR) and behave as noise-like wide band digital signals with 1.2288 Mbps transmission rate. For signals with high PAR like CDMA, it is reasonable to prescribe occupied bandwidth(OBW) as average occupied bandwidth. Bandwidth measurements of CDMA signals at remote site are affected by co-channel and adjacent channel interference from adjacent CDMA base station, distortion of signal by fading effect, spurious emission and environment noises. In this study, we have compared OBW measurements in an on-air environment with those measured in a base station using adjacent channel leakage ratio(ACLR) as a reference measurement factor. As results of analysis, the OBW at ACLR$\geq$35 ㏈ shows nearly same statistical characteristics regardless of the measurement locations and environments.

Breakdown Characteristics of a Punch-through Diode with N+P+P-H+ Structure (N+P+P-N+ 구조를 가진 Punch-through 다이오드의 항복전압 특성)

  • Song, Se-Won;Chung, Sang-Koo;Choi, Yearn-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.3-5
    • /
    • 2002
  • Breakdown characteristics of a punch-through diode with n+p+p-n+ structure are analyzed with two-dimensional device simulation. Effects of base doping concentration and profile on the breakdown are presented. An analytical expression of a maximum base doping level for the punch-through breakdown is derived. The diode with a linearly graded base doping shows superior leakage current and capacitance is satisfactory for applications for low-voltage circuits.

  • PDF

A Case Study of Remediation Grouting for Stopping Leakage of Concrete Dam Base (콘크리트 댐 기초 누수방지 보수그라우팅 사례)

  • 천병식;김진춘;최영철
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.449-456
    • /
    • 2000
  • Remediation grouting has been widely used for the rehabilitation of various civil works like hydraulic and traffic structures. Recently there were some cases of remediation grouting for repairing old dams in korea. So this study will describe the case of remediation grouting of the concrete dam base located east-northern part of Seoul. We use Lugeon Test and Borehole Image Processing System(BIPS) for estimating the effectiveness of remediation grouting of this project. As the results of this study, we could find the lots of joints between the old concrete body and the weathered rock base. So the about 30% quantity of total cement grouts was injected at the boundary surface between concrete and rock base. And Lugeon Test and BIPS could be compared relatively because BIPS results could be presented quantitatively as well as qualitative analysis. Finally, we could find microfine cement was very effectively injected to the fine fissured concrete body compared with ordinary portland cement, but there was little injectability differences beteween microfine cement and ordinary portland cement at the large cracks or cavities were developed rock base.

  • PDF