• Title/Summary/Keyword: base cavity

Search Result 149, Processing Time 0.03 seconds

A STUDY FOR THERMAL CONDUCTIVITY OF IRRADIATED CAVITY (와동내에 조사된 열의 전도양상에 관한 연구)

  • Baik, Byeong-Ju;Kim, Jae-Gon;Hur, Sun;Lee, Du-Cheol;Yun, Hyun-Du
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.583-597
    • /
    • 1998
  • The purpose of this study was to evaluate temperature change occurred in enamel, dentin and pulp due to the heat from cavity prepration with laser. We made three models had different cavity depth: cavity depth of model A was 3.52mm, model B was 2.32mm, model C was 1.16mm. We irradiated cavity base with thermal capacity of $30J,100J,300J/cm^2s$ during few seconds and studied the change of temperature in tooth during 10 seconds, and estimated change of thermal capacity by different irradiated site and exposure time. At $300J/cm^2$ irradiation for 2 seconds, the temperature of irradiated surface was elevated fast according to irradiated thermal energy during 1 second. In proportion to continuous exposure time, temperature elevated slowly. The surface temperature was $1370^{\circ}C$. After discontinue of thermal irradiation, the heat of irradiated surface was diffused in dentin and pulp and the greatest temperature was made. The greatest temperature was disappeared within 10 seconds The greatest temperature of the inner part of model brought about very severe change by different depth. Temperature in pulp was raised by the greater irradiated energy density and exposure time.

  • PDF

INTRAPULPAL TEMPERATURE CHANGE OF GLASS IONOMER ACCORDING TO LIGHT CURING INTENSITY AND CURING TIME (광중합기의 광도와 시간에 따른 글래스 아이오노머의 치수내 온도변화)

  • 김희량;이형일;이광원;이세준
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.387-392
    • /
    • 2001
  • When cavity floor is near the pulp, polymerization of light-activated restorations results in temperature increase. This temperature increase cause by both the exothermic reaction process and the energy absorbed during irradiation. Therefore instating base is required. Most frequently used insulating base is glass ionmer. The purpose of this study was to evaluate intrapulpal temperature changes of glass ionomer according to various curing intensity and curing time. Caries and restoration-free mandibular molars extracted within three months were prepared Class I cavity of 3$\times$6mm with high speed handpiece. 1mm depth of dentin was evaluated with micrometer in mesial and distal pulp horns. Pulp chambers were filled with 37.0$\pm$0.1$^{\circ}C$ water to CEJ. Chromium-alumina thermocouple was placed in pulp horn for evaluating of temperature changes. glass ionomer material was placed in 2mm. total curing time was 40s: continuous 40s, intermittent 20s, intermittent 10s. Glass ionomer material was cured with 300mW/$\textrm{cm}^2$, 550mW/$\textrm{cm}^2$ light curing unit. The results were as follows : 1. Temperature in pulp increased as curing unit power is increased. 2. Temperature in pulp more increased continuous emission than intermittent emission.

  • PDF

Relative Growth and Squamation in Larvae and Juvenile of Cultured Larimichthys polyactis (Sciaenidae) (양식산 참조기(Larimichthys polyactis) (민어과) 자치어의 상대성장과 비늘 형성)

  • Soo-Been Kim;Jeong-Hyeon Cho;Jin-Koo Kim
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.3
    • /
    • pp.324-330
    • /
    • 2023
  • We investigated the relative growth and squamation of larvae and juveniles of cultured Larimichthys polyactis. Analysis of the relative growth of larvae and juveniles showed that their preanal length, head length, eye diameter, body depth, and snout length increased with growth. There was no significant chage in the relative growth. The ratio of preanus length to standard length (SL) increased rapidly until SL was approximately 12 mm, and then increased gradually. Cycloid scales first appeared on the lateral line, progressed to the abdominal cavity at 15.13 mm SL, and expanded to the occipital region, base of pectoral fin, and ventral region of the eye at 17.82 mm SL. At 18.03 mm SL, scales formed on the cheek, and those at the base of pectoral fin and in the abdominal cavity were connected to each other. At 19.06 mm SL, major part of the head was covered by scales, except near the lower jaw. Cycloid scales on the lateral line changed to ctenoid scales at the range of 31.71-32.24 mm SL, and those on the nape changed at the range of 69.02-70.84 mm SL. Our results may help to establish conservation and management strategy for Larimichthys polyactis aquaculture.

Optimization of feed system of base mold for washing machine using CAE (사출성형 CAE를 이용한 세탁기용 Base 성형용 금형의 유동 시스템 최적화)

  • Yoo, Min-ji;Kim, Kyung-A;Han, Seong-Ryeol
    • Design & Manufacturing
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • The position of the gate is one of the important factors for optimal injection molding. This is because inappropriate gate positions cannot fill the cavity uniformly, which can lead to defects such as contraction. In this study, CAE was performed on hot runner injection molding of the washing machine base and plasticity was compared by changing gate position from existing gate position. A total of two alternatives have been applied to compare the plasticity of the washing machine base according to its optimal gate position. The gate position of the improved molds and the gate position of the current mold is analyzed by injection molding analysis. The results of the fill time, the pressure at V/P switchover, clamping force, and deflection were compared. In washing machine base injection molding, the deflection was reduced by about 3.76% in the improved mold 2. In improved mold 1, the fill time during injection molding was reduced by 3.32% to enable uniform charging, and the clamping force was reduced by 31.24%. We have confirmed that the position of the gate can change the charging pressure and the clamping force and affect the quality and cost savings of the molded product.

High-Gain Fabry-Pérot Cavity Antenna with Planar Metamaterial Superstrate for Wibro Base Station Antennas (평판형 메타 물질로 구성된 상부 덮개를 갖는 와이브로 기지국용 고 이득 Fabry-Pérot 공진기 안테나)

  • Kim, Dong-Ho;Choi, Jae-Ick
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1367-1374
    • /
    • 2008
  • A new high-gain Fabry-$P{\acute{e}}rot$ cavity antenna for wireless broadband internet(Wibro) base station antennas, which is covered with metamaterial superstrate presenting simultaneous negative values of permittivity and permeability, is proposed. To facilitate the fabrication process using the printed circuit board(PCB) technology of today, a new planar-type metamaterial superstrate is designed, which shows negative and low positive values of a refractive index near the Wibro service frequency band. And the principle of antenna gain enhancement is analyzed from the two different view points of effectively low refractive index and of the Fabry-$P{\acute{e}}rot$ resonance condition. Single square patch antenna is used as a feeder. The separation distance is determined by considering the reflection phases of the metamaterial superstrate and the substrate satisfying Fabry-$P{\acute{e}}rot$ resonance condition, respectively. Comparison between the prediction and the measurement shows good agreement, which verifies the validity of our design approach.

An Experimental Study on Suppression of Cavity Development by Enlargement of Base Plate of Box-Culvert Installed at River Levee (하천제방 배수통문의 저판확폭을 통한 공동발생 억제기법 연구)

  • Kim, Jin-Man;Choi, Bong-Hyuck;Lee, Dae-Young;Jin, Young-Ji
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.3
    • /
    • pp.55-61
    • /
    • 2011
  • Generally, the Box-Culvert in levee is destroyed by various reasons. Especially when Box-Culvert is installed over the pile foundation in soft ground, the failure occurrs for 1) the weakness of compaction in Box-Culvert side by the differential settlement between outer ground and inner soil prism, 2) hydraulic fracturing and disturbance of Box-Culvert side soil by the repeated acting of seepage pressure at flood time. Also the side of Box-Culvert is difficult to compact and the shear resistance is reduced by more than 1/3 for the reduction of friction caused by the difference of material property. In this study, a series of model tests are conducted for the analysis of the development mechanism of outer ground and inner soil prism by the differential settlement using the pile foundation in soft ground, and cavity suppressed technique is suggested by the analysis of base plate enlargement effect.

AN EXPERIMENTAL STUDY FOR THE EFFECT OF SANDWICH TECHNIQUE ON MICROLEAKAGE IN CLASS V CAVITY (Sandwich 술식에 제V급 와동의 미세 변연누출에 미치는 영향에 대한 연구)

  • Shin, Chang-Seung;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.447-462
    • /
    • 1993
  • To evaluate the marginal leakage in Class V cavity this study has been undertaken to compare the sandwich technique with the conventional method, and find out the effect of lining material, lining method, and polishing time on sandwich technique. Ninty extracted teeth were divided into eight test groups and a control group, and were prepared with a buccal Class V cavity. Four test groups were lined with Dentin Cement whereas the other four test groups were lined with Vitrabond. Half of the either group were lined 0.5mm short of the carvosurface margin and the rest were lined completely to the carvosurface margin. The four subgroups were further divided into specimens which were polished immediately and 24 hours after resin filling. The polished specimens were immersed in $37^{\circ}C$, 0.5% methylene blue solution for 24 hous after thermocycling at $5^{\circ}C$ and $55^{\circ}C$, 200 times and buccolingually sectioned. The sectioned specimens were examined dye penetration under the light microscope. The following results were obtained, 1. At the enamel margin, the conventional method showed a lower microleakage than the sandwich technique. The difference between the control and Vitrabond group was statistically significant(P<0.05), but no difference between the control and Dentin Cement group, and between the lining materials was observed. 2. At the dentinal margin, the sandwich technique showed a significant lower amount of microleakage (P<0.05), but there was no significant difference between the lining materials. 3. Regardless of the lining material, lining method, and polishing time used, values of microleakage were significantly higher at the dentinal margin compared to the enamel margin(P<0.05). 4. In specimens till the cavosurface margin, microleakage at the dentinal margin was less with the light-cured base than with the chemically-cured base, but there was no siginificantly difference between the lining materials regarding the lining method and polishing time. 5. The lining material, lining method, and polishing time did not affect the amount of micro leakage in the sandwich technique(P<0.05).

  • PDF

Comparison of Temperatures of the Resin Cement in Polycrystalline Ceramic Brackets Irradiated Using a Diode Laser

  • Son, Young-Tak;Son, KeunBaDa;Kim, Kyung-Min;Lee, Jae-Mok;Kim, Jin-Wook;Yu, Wonjae;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • v.14 no.2
    • /
    • pp.69-78
    • /
    • 2021
  • Purpose: The primary objective of this study was to evaluate the change in the temperature of the adhesive resin in polycrystalline ceramic brackets irradiated using a diode laser at different irradiation energy levels and times. Materials and Methods: For the measurement of the temperature of the adhesive resin, it was applied at the base of the ceramic bracket, a thermocouple was placed at the center of the base surface, the bracket was placed on prepared resin specimens for light curing, and a laser was irradiated to the center of the bracket slot at 5, 7, and 10 W. For the measurement of the temperatures of the enamel under the bracket and pulp cavity, extracted premolar was fixed to a prepared mold and the ceramic bracket was bonded to the buccal surface of the premolar. The Kruskal-Wallis H test and Friedman test were used for statistical analysis. Result: At 5 W, the temperature of the adhesive resin did not reach the resin softening temperature of 200℃ within 30 seconds. At 7 W, it reached 200℃ when the ceramic bracket was irradiated continuously for 28 seconds. At 10 W, it reached 200℃ when the ceramic bracket was irradiated continuously for 15 seconds. During laser irradiation, the temperature of the enamel under the bracket increased by over 5℃ within 15 seconds. Conclusion: The use of diode laser irradiation for bracket debonding should be carefully considered because the pulp cavity temperature increases by over 5℃ within the irradiation time for resin thermal softening.

Two Cases of Choristoma in Base of the Tongue (설기저부에 발생한 골성 분리종 2예)

  • Jung Ki-Nam;Chun Jin-Hyoung;Choi Young-Hee;Park Chan-Hum
    • Korean Journal of Head & Neck Oncology
    • /
    • v.20 no.1
    • /
    • pp.49-51
    • /
    • 2004
  • A choristoma is a tumor like mass of normal tissue in an abnormal location. Lingual osseous choristoma, previously known as osteoma of the tongue base, is rare entity. That is defined as a normal bone mass occuring in the soft tissue of either the skin or the mucosa of oral cavity. The cause of osseous choristoma of the tongue is still unknown, but only several theories have been suggested. Because of the rarity of this entity, our purpose is to add our case to the literature, and to discuss the nature of the disease.

Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature

  • Al Jabbari, Youssef S.
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.138-145
    • /
    • 2014
  • Cobalt-Chromium (Co-Cr) alloys are classified as predominantly base-metal alloys and are widely known for their biomedical applications in the orthopedic and dental fields. In dentistry, Co-Cr alloys are commonly used for the fabrication of metallic frameworks of removable partial dentures and recently have been used as metallic substructures for the fabrication of porcelain-fused-to-metal restorations and implant frameworks. The increased worldwide interest in utilizing Co-Cr alloys for dental applications is related to their low cost and adequate physico-mechanical properties. Additionally, among base-metal alloys, Co-Cr alloys are used more frequently in many countries to replace Nickel-Chromium (Ni-Cr) alloys. This is mainly due to the increased concern regarding the toxic effects of Ni on the human body when alloys containing Ni are exposed to the oral cavity. This review article describes dental applications, metallurgical characterization, and physico-mechanical properties of Co-Cr alloys and also addresses their clinical and laboratory behavior in relation to those properties.