• Title/Summary/Keyword: bar mats

Search Result 5, Processing Time 0.02 seconds

Finite element study the seismic behavior of connection to replace the continuity plates in (NFT/CFT) steel columns

  • Rezaifar, Omid;Younesi, Adel
    • Steel and Composite Structures
    • /
    • v.21 no.1
    • /
    • pp.73-91
    • /
    • 2016
  • The use of box columns has been increased due to the rigidity in rigid orthogonal moment resisting frames. On the other hand, the installation and welding of necessary horizontal continuity plates inside the columns are both labor-consuming and costly tasks. Accordingly, in this paper, a new beam-to-box column connection by trapezoidal external stiffeners and horizontal bar mats is presented to provide seismic parameters. The proposed connection consists of eight external stiffeners in the level of beam flanges and five horizontal bar mats in Concrete Filled Tube (CFT) columns. The new connection effectively alleviates the stress concentration and moves the plastic hinge away from the column face by horizontal external stiffeners. In addition, the result shows that proposed connection has provided the required strength and rigidity of connection, so that the increased strength, 8.08% and rigidity, 3.01% are compared to connection with internal continuity plates, also the results indicate that this connection can offer appropriate ductility and energy dissipation capacity for its potential application in moment resisting frames in seismic region. As a result, the proposed connection can be a good alternative for connection with continuity plates.

Structural Performance of RC Slab-Wall Joints Reinforced by Welded Deformed Steel Bar Mats (철근격자망을 사용한 슬래브-벽체 접합부의 구조성능)

  • Park, Seong-Sik;Yoon, Young-Ho;Lee, Bum-Sik
    • Land and Housing Review
    • /
    • v.2 no.1
    • /
    • pp.61-68
    • /
    • 2011
  • In order to clarify the structural performances of Welded Deformed Steel Bar Mats (WDSBM), the research stated includes the tests for standard hook of top bars of slab in concrete slab-wall joints, the tests for embedment length of top bar of slab, and the development strength tests for standard hook. The test results are as follows; (1) For slab-wall joints using WDSBM as reinforcement in slab, if the top bars of WDSBM are spliced by ordinary bars with sufficient development length and size, it is enough for the strength and crack control. (2) When WDSBM of slab is spliced in joint, the strength is increased with the embedment of bars of this WDSBM into wall. Beyond peak strength, however, ductility is diminished to that as no splice due to pull-out failure. (3) For slab-wall system, ultimate strain of concrete for flexural compression zone in lower surface of slab seems much greater than that of normal concrete beam. The reason is that normal concrete beam has the joint with $180^{\circ}$, however slab-wall joint has the $90^{\circ}$ of which concrete can be confined.

Home Environmental Hazards of Falling Accident in the Elderly (노인가정의 낙상사고 위험 환경요인)

  • Park, Young-Hae;Moon, Jung-Soon
    • Korean Journal of Health Education and Promotion
    • /
    • v.22 no.4
    • /
    • pp.203-213
    • /
    • 2005
  • Purpose: To assess the environmental hazards of falling accident in the homes of the elderly. Method: 222 homes of the elderly were assessed by the home environmental Checklist from May to July in 2003. Results: The mean score of home environmental hazards for fall were 13.19 with the highest score being 49, ranging from 4 to 24. The bathroom was the most hazardous place in the home, porch came next bedroom, kitchen, living room and stair followed them. The floor surface such as finishes and non-skid mats was the most hazardous interior factor in the home, using bathroom came next furniture and illumination followed them. The floor surface such as finishes and non-skid mats in the bathroom, kitchen, living room and porch, illumination of bedroom and stair were the most prevalent hazards in the home of interior. Of the 49 potential hazards, bathroom grab bar was the most prevalent one with 89.9%, and non-skid rugs in the porch, bathroom and kitchen, safety of dinner table, the threshold and furniture of porch, and illumination of bedroom were prevalent more than half of the home under assessing. Men, living in the separate house or villa with stairs were in more hazardous environments. Conclusion: To reduce the potential hazards of fall accident in the home, improving hazards relating to floor surface such as slip resistance surface and mats is important specially those of the separate house or villa with stairs.

A Fundamental Study on the Effect to Build up a Vegetation Strip at Stream Confluence by Using Reed Mat (하천합류부에서 갈대매트를 이용한 하천식생대 조성에 대한 기초적 연구)

  • Chung, Kyung-Jin;Kim, Mi-Kyeong;An, Won-Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.4
    • /
    • pp.62-73
    • /
    • 2003
  • The study was to apply a mat style reed planting method at confluence to improve plants growth conditions by relaxing disturbed topographical base due to water flow and was intended to review the effect to build up a vegetation strip by monitoring process after the construction. First off, We've attempted to construct reed mats on selected sites as confluences of Tan and Gaehwa stream and then examined and analyzed characteristics of soil and vegetation community. As the results of the examination, the soil texture was proven to be a mix of sand and loamy sand and be 6.3 ~ 7.0 soil pH. In addition, it contained 1.0 ~ 4.6% of organic matter, 0.04 ~ 0.22% of T-N and 27.8 ~ 41.2% of water content. For its vegetation structure, the Tan stream confluence was first actually a point bar without plants prior to the construction but 8 kinds of hygrophytes including Persicaria hydropiper and 9 kinds of terrestrial plants such as Potentilla supina, Artemisia annua, and Alopecurus aequalis var. amurensis. On the other hand, the Gaehwa stream confluence contained 6 kinds of hygrophytes such as Bidens frondosa and other 11 kinds of terrestrial plants prior to the construction while it produced 7 kinds of hygrophytes including Ranunculus ternatus as well as Phragmites australis and 9 kinds of terrestrial plants such as Potentilla supina after the construction. For the Phragmites australis, almost of them was weathered away in early days just after planting because of development period passed, but on May, six months later from planting, it was investigated that its length was approximated as 65 ~ 85cm with 75% coverage and that the number of it was 437 ~ 633/$m^2$. The study was shown that reed mats can improve environmental conditions of disturbed topographical base, enabling natural growth of various riparian vegetation including the introduced plant, reed. In the meantime, it was supposedly judged that to recover or build up a vegetarian strip, supplementary materials should be prepared to help produce and grow plants because it is not probable to expect river drift by water flow at confluence and that corrosion, burying or inundation owing to changes of water lever should be considered.

Tensile Strength-Strain Relationship of Various Geogrids (다양한 지오그리드의 인장강도-인장변형 관계 특성)

  • Han, Sang-Hyun;Yea, Geu-Guwen;Lee, Kwang-Wu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.2
    • /
    • pp.83-93
    • /
    • 2012
  • Since reinforced soil walls were introduced in domestic civil engineering society in early 1980's, various reinforcing materials including metal strips, bar mats, and sheet-type reinforcement using geotextile, geogrid, and etc. have been developed for construction purpose. Especially, the geogrid has been mostly used as a reinforcement for reinforced earth structures. This paper describes the tensile behaviors of four types of domestic geogrids. Also, a series of the wide-width tensile tests on three types of geogrids were conducted to assess the reliability of the tensile strains in geogrid measured by strain gauge. The tensile strain by strain gauge is larger than real strain of the geogrid and a difference between strain gauge reading and real strain non-linearly increase with increasing the tensile strain. However, when the tensile strain is smaller than 3%, a difference between strain gauge reading and real strain is negligible.