• 제목/요약/키워드: band-pass amplifier

검색결과 83건 처리시간 0.025초

EOG(Electro-oculogram) 신호를 이용한 Interface 장치 개발 (Development of Interface device with EOG Signal)

  • 김수종;유호선;김영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1821-1823
    • /
    • 2006
  • This paper presents a development of interface device for electro-oculogram(EOG) signal and it's application to the wireless mouse of wearable PC. The interface device is composed of five bio-electrodes for detecting oculomotor motion, several band-pass filters, instrumentation amplifier and a microprocessor. we have first analyzed impedance characteristics between skin and a bio-electrode. since the impedance highly depends on human face, it's magnitude differs from person. this interface device was applied to develop a wireless mouse for wearable PC, as a Bio Machine Interface(BMI). Where in the prompt on PC monitor is controlled by only EOG signals. this system was implemented in a Head Mount Display(HMD) unit. experimental results show the accuracy of above 90%.

  • PDF

모바일용 디지털 오디오 스피커를 위한 고효율 드라이버 설계 (A High-Efficiency Driver Design for Mobile Digital Audio Speakers)

  • 김용석;임민중
    • 전기학회논문지P
    • /
    • 제60권1호
    • /
    • pp.19-26
    • /
    • 2011
  • In this paper, we designed Interpolation FIR(Finite Impulse Response) filter and 1-bit SDM(Sigma- Delta Modulator) for small digital audio speaker, which has low power consumption and high output characteristics. In order to achieve high linearity and low distortion performance of the systems, we adopt Type I Chevychev FIR filter which has equiripple characteristics in the pass band and proposed high efficient FIR filter structure. SDM is the most efficient modulation technique among the noise shaping techniques. In this paper, we implemented SDM using CIFB(Cascade of Intergrators, Feed-Back) which is generally used in DAC of small digital audio speakers. The proposed SDM structure can achieve high SNR, high-efficiency characteristics and low power consumption in mobile devices. Also considering manufacture of SoC(System on Chip), we performed simulation with Matlab and Verilog HDL to obtain optimal number of operational bits and verified a good experimental results.

Detection of the Ultrasonic Signals due to Partial Discharges in a 154kV Transformer

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.297-303
    • /
    • 2002
  • We have developed an on-line ultrasonic detector to monitor partial discharge in an operating transformer. The ultrasonic sensor has 150[KHz] resonance frequency and contains a pre-amplifier with 60[㏈] gain. The on-line ultrasonic detector has 50~300[KHz] frequency band-pass filter to remove electrical and mechanical noises from the transformer. This detector has an ultrasonic signal discrimination algorithm which discriminates ultrasonic signals due to partial discharge in a transformer. A moving average method of ultrasonic signal number was employed to effectively monitor the increasing trend of the partial discharge. This paper describes an experience of partial discharge detection in a 154[㎸] operating transformer using an ultrasonic detector. With regards to gas analysis in oil, C2H2 gas was produced with a warning level in this transformer We detected ultrasonic signals on the transformer steel wall, and estimated the position of partial discharge. With further inspection, we found carbonized marks due to partial discharge on the supporting bolt which fastens the windings.

휴대용 심전도 모니터링 계측 시스템 개발에 관한 연구 (Development of an Ambulatory Wearable System for Continuous Patient Monitoring)

  • 박찬원;전찬민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.920-923
    • /
    • 2003
  • An wearable electrocardiogram (ECG) monitoring system is a widely used non-invasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we have a portable ECG monitoring system with conductive fiber which was characterized by the small-size and the low power consumption. The system consists of conductive fibers, one-chip microcontroller, ECG preprocessing circuit, and monitoring software to be able to record and analyze in PC. ECG preprocessing circuit is made of pre-amplifier with gain of 10, band-pass filter with bandwidth of 0.5-120Hz and 2.5V offset circuit for A/D conversion. ECG signals obtained by sensor are included with corrupted noises such as a baseline wandering, 60 Hz power noise and interference noise by body movement. For cancellation corrupted noises in signals obtained by conductive fiber, we used the wavelet decomposition of wavelet transforms in MATLAB toolbox.

  • PDF

AE Sensor를 적용한 C-GIS내의 PD 특성 (PD Characteristics in C-GIS Using AE Sensor)

  • 이용희;신양섭;장수형;서정민;이용희;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1652-1654
    • /
    • 2002
  • The defects making partial discharge(PD) in a C-GIS(Cubicle Insulated Switchgear) initiate acoustic wave which can be detected using acoustic emission sensor placed outside or inside the C-GIS enclosure. In this paper, partial discharge property for 2 locations for AE sensor and 3 locations for defects in C-GIS are presented and PD waveforms were analyzed by PRPDA(Partial Resolved Partial Discharge Analysis). As a result, using post amplifier having gain of 10,000 and band pass filter having $20kHz{\sim}300kHz$, resolution of waveforms AE sensor signal by detected was good. Noise level was about 80 mV.

  • PDF

기준전극의 형상과 입력전극사이의 간격을 고려한 건식형 표면 근전위 센서 개발 (Development of Dry-type Surface Myoelectric Sensor for the Shape of the Reference Electrode and the Inter-Electrode Distance)

  • 최기원;최규하
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권12호
    • /
    • pp.550-557
    • /
    • 2006
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper is proposed two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value(MAV) circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

CMFF CMOS 인버터 타입 OTA를 이용한 Gm-C 필터 설계 (A Gm-C Filter using CMFF CMOS Inverter-type OTA)

  • 최문호;김영석
    • 한국전기전자재료학회논문지
    • /
    • 제23권4호
    • /
    • pp.267-272
    • /
    • 2010
  • In this paper, a Gm-C LPF utilizing common-mode feedforward (CMFF) CMOS inverter type operational transconductance amplifier (OTA) has been designed and verified by circuit simulations. The CMFF CMOS inverter OTA was optimized for wide input linearity and low current consumption using a standard 0.18 ${\mu}m$ CMOS process; gm of 100 ${\mu}S$ and current of 100 ${\mu}A$ at supplied voltage of 1.3 V. Using this optimized CMFF CMOS inverter type OTA, an elliptic 5th order Gm-C LPF for GPS specifications was designed. Gain and frequency tuning of the LPF was done by changing the internal supply voltages. The designed Gm-C LPF gave pass-band ripple of 1.6 dB, stop-band attenuation of 60.8 dB, current consumption of 0.60 mA at supply voltage of 1.2 V. The gain and frequency characteristics of designed Gm-C LPF was unchanged even though the input common-mode voltage is varied.

국부발진기에서의 누설신호의 새로운 제거방식 (A Novel Method to Reduce Local Oscillator Leakage)

  • 이병제;강기조
    • 한국전자파학회논문지
    • /
    • 제11권2호
    • /
    • pp.294-301
    • /
    • 2000
  • RF(radio frequency) 시스템의 송신탄을 설계할 때 고려해야 할 중요한 요소 중의 하나인 EMI(Electro magnetic interference)의 규격시험에서 항상 문제시되는 것이 송신기의 출력 스펙트럼에서 나타나는 불요 신호(Spurious interference) 이다. 이 불요 성분들 중 특히 문제가 되고 있는 것이 국부발진기(LO; Local oscillator)로부터 누설되는 LOL(Local oscillator leakage) 성분이다. 이 LOL성분은 국부발진기에서 누설(leakage)되어 RF단의 증폭기를 통하여 증폭되어 최종 출력에서 매우 높은 선호의 크기로 나타난다. 일반적으로 LOL을 제거하기 위해 서 너치필터(Notch filter) 또는 대역통과필터 (Band pass filter)를 사용해왔다. 본 논문에서는 국부발진기로부터 누설되는 불요 성분, 즉 LOL성분을 제거하는 방법으로 LOL과 동일한 크기를 가지고 위상 차이가 $180^{\circ}$인 신호를 국부발전기의 출력에서 만들어 믹서( Mixer)의 출력단에 더함으로써 LOL성분을 효과적으로 제거한다. 본 방 식을 무선랜(WLAN; Wireless 1$\infty$al area network) 시스템에 적용한 결과. 기존의 방식보다 30 dB 이상 LO 누설선호플 감쇄시킬 수 있었다 또한 본 방식은 RF 시스댐을 소형화 및 MMIC(Monolithic microwave integrated C circuit)화 할 경우 종전의 방법보다 효과적일 것으로 기대된다.

  • PDF

생체신호 측정을 위한 아날로그 전단 부 회로 설계 (Analog Front-End Circuit Design for Bio-Potential Measurement)

  • 임신일
    • 전자공학회논문지
    • /
    • 제50권11호
    • /
    • pp.130-137
    • /
    • 2013
  • 본 논문은 생체신호 측정을 위한 저전력/저면적 AFE(analog front-end)에 관한 것이다. 제안된 AFE는 계측증폭기(IA), 대역 통과 필터(BPF), 가변 이득 증폭기(VGA), SAR 타입 A/D 변환기로 구성된다. 전류 분할 기법을 이용한 작은 gm (LGM) 회로와 고 이득 증폭기로 구성된 Miller 커패시터 등가 기술을 이용하여, 외부 수동소자를 사용하지 않고 AC-coupling을 구현하였다. 응용에 따른 BPF의 고역 차단 주파수 변화는 전압 조절기(regulator)를 이용한 출력 전압 변화를 이용하여 $g_m$을 변화하여 구현 시켰다. 내장된 ADC는 커패시터 분할 기법을 적용한 이중 배열 커패시터 방식의 D/A변환기와 비동기 제어 방식을 이용하여 저 전력과 저 면적으로 구현하였다. 일반 CMOS 0.18um 공정을 이용하여 칩으로 제작하였고, 전체 칩 면적은 PAD등을 모두 포함하여 $650um{\times}350 um$이다. 제안된 AFE의 전류 소모는 1.8V에서 6.3uA이다.

OTA기반의 차단대역 조정이 가능한 3-입력/1-출력 구조의 다기능 Gm-C 필터 (Stopband Tunable Multifunctional Gm-C Filter based on OTA with Three-Input/Single-Output)

  • 바스넷버룬;방준호;송제호;유인호
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권5호
    • /
    • pp.201-206
    • /
    • 2015
  • 본 논문에서는 연산 트랜스컨덕턴스 증폭기를 기반으로 하여 차단주파수 대역의 조정이 가능한 3-입력와 1-출력단을 갖는 Gm-C필터가 제안되었다. 제안된 필터는 대역통과, 저역통과 및 고역통과의 다기능 필터 특성을 갖는다. 구현된 필터의 중심주파수($f_c$)와 특성요소(Q)값은 다른 필터특성의 변형없이 독립적으로 조정이 가능할 수 있음을 확인하였다. 또한 전체 시스템에 영향을 줄 수 있는 다양한 파라미터들과 기생요소들에 대한 감도특성과 비이상성분석이 수행되었다. 제안된 필터를 CMOS 소자로 구현하기 위하여 1.8V-0.18um 공정파라미터를 사용하였고 HSPICE를 활용하여 특성을 분석한 결과와 기 정리된 이론값들과 비교하여 나타내었다.