• Title/Summary/Keyword: balance measurement system

Search Result 180, Processing Time 0.023 seconds

The Effect of Moxibustion at Jeonjung($CV_{17}$) on the Heart Rate Variability in Healthy Adults (膻中穴($CV_{17}$) 간접구요법이 정상 성인의 심박변이도(HRV)에 미치는 영향)

  • Lee, Jeong-Ju;Kim, Seong-Joung;Park, Ok-Ju;Lee, Sang-Mi;Park, Min-Cheol;Jo, Eun-Heui
    • Journal of Acupuncture Research
    • /
    • v.29 no.4
    • /
    • pp.43-53
    • /
    • 2012
  • Objectives : This study was accomplished to investigate the effects of moxibustion at Jeonjung($CV_{17}$) on the heart rate variability(HRV) in healthy adults. And based on that, we tried to find out how moxibustion at Jeonjung($CV_{17}$) effects on the activity and balance of the autonomic nervous system Methods : We investigated on 50 healthy volunteers consisted of 24 subjects in moxibustion group and 24 subjects in control group. On the other hand, two volunteers were ruled out by standard of elimination. The study was established by randomized trial. Moxibustion was applied at Jeonjung($CV_{17}$) and rested during 10 minutes in moxibustion group. No treatment was executed in control group. We measured HRV 3 times : baseline measurement and after treatment in moxibustion group(after rest in control group) twice. The SPSS 12.0 for windows was used to analyze the data by paired t-test, Wilcoxon signed ranks test(in group) and Independent t-test, Mann-Whitney U-test (between the groups). Results : 1. In moxibustion group, mean HRT decreased significantly. Ln(VLF) increased significantly. Ln(TP) decreased significantly at $2^{nd}$ time and increased significantly at $3^{rd}$ time. SDNN, RMSSD, PSI, Ln(LF), Ln(HF), Normalized LF, Normalized HF and LF/HF ratio were not affected. 2. In control group, PSI and normalized HF decreased significantly. SDNN, Ln(TP), Ln(VLF), normalized LF and LF/HF ratio increased significantly. Mean HRT, RMSSD, Ln(LF) and Ln(HF) were not affected. Conclusions : This study suggest that moxibustion at Jeonjung($CV_{17}$) makes no effects on the balance of the autonomic nervous system.

A Dataset from a Test-bed to Develop Soil Moisture Estimation Technology for Upland Fields (농경지 토양수분 추정 기술 개발을 위한 테스트 베드 데이터 세트)

  • Kang, Minseok;Cho, Sungsik;Kim, Jongho;Sohn, Seung-Won;Choi, Sung-Won;Park, Juhan
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.3
    • /
    • pp.107-116
    • /
    • 2020
  • In this data paper, we share the dataset obtained during 2019 from the test-bed to develop soil moisture estimation technology for upland fields, which was built in Seosan and Taean, South Korea on May 3. T his dataset includes various eco-hydro-meteorological variables such as soil moisture, evapotranspiration, precipitation, radiation, temperature, humidity, and vegetation indices from the test-bed nearby the Automated Agricultural Observing System (AAOS) in Seosan operated by the Korea Meteorological Administration. T here are three remarkable points of the dataset: (1) It can be utilized to develop and evaluate spatial scaling technology of soil moisture because the areal measurement with wide spatial representativeness using a COSMIC-ray neutron sensor as well as the point measurement using frequency/time domain reflectometry (FDR/TDR) sensors were conducted simultaneously, (2) it can be used to enhance understanding of how soil moisture and crop growth interact with each other because crop growth was also monitored using the Smart Surface Sensing System (4S), and (3) it is possible to evaluate the surface water balance by measuring evapotranspiration using an eddy covariance system.

Measurement of Nursing Service Quality using SERVQUAL Model (SERVQUAL 모델을 이용한 간호 서비스 질 측정)

  • Lim, Ji-Young;Kim, So-In
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.6 no.2
    • /
    • pp.259-279
    • /
    • 2000
  • This study is a descriptive analytic research measuring nursing service quality, using SERVQUAL model, to make fundamental data and strategies for nursing service improvement. Data were collected by self-reported questionnaire from 202 patients and 142 nurses, from June 7 to 14, 1999. The reliability of instrument were adequate(Cronbach ${\alpha}=.94$). SAS program was utilized for statistical analysis of collected data. The results were as follows; 1. There was a gab between patient's expectation and perception on nursing service(Gap B). Gap D was indicated an affecting factor to decide nursing service quality. Gap C was indicated an indirect affecting factor of nursing service quality. Because it was not statistically significant in total item analysis, but in individual item analysis, 7 items were appeared statistically significant. Gap A was not a gap occurrence factor of nursing service quality. 2. Focuses of nursing service quality improvement strategies were; (1) to direct qualitative improvement of nursing service in order to correspondence patient's nursing service expectation. (2) to make nurse's service activity modified because nurse's practice were not reached patient's expectation level. (3) to need internal, external factor analysis affecting nurse's service activity. 3. Nursing service quality was decided by rather environmental inappropriateness provided nursing service than itself. Therefore, to make nursing service quality improvement, it is required to improve nursing service environment. For this, followings are required; (1) to strengthen nurse's education on lower part of nursing service satisfaction and QI activities. (2) to balance demand and supply of nursing personnel. 3) to fix computerized system for reducing other duties weight except nursing care through analysis of nursing activity. (4) to construct rational cooperating system among related departments. 4. The important parts for nursing service quality improvement were indicated as follows: (1) Gap B: 'prompt reaction', 'examination symptom before patient's complaint', 'hearted nursing service reducing patient's dissatisfaction', 'explanation goals of nursing activities', 'having special Knowledge enough', 'maintenance position comfortably', 'management of patient's physical hygiene'. (2) Gap C: 'maintenance physical safety', 'explanation about hospital rules and facilities'. (3) Gap D: 'tender, safe injection and wound care'. Because above items are mostly improved through nurse's attitude change and quality improvement, it is required to establish nursing standardization and to strengthen nurse's clinical education. As the based on above results, followings are suggested; 1. SERVQUAL model is very useful to make strategies for nursing service quality improvement because it indicates multiple factors affecting hap occurrence. 2. At individual items analysis of Gap C, statistically significant 7 items appeared higher nurse's perception level than patient's perception level on nursing service were trouble perception level on nursing service quality improvement. So. it need further research to analysis about these difference occurring factors. 3. At analysis of Gap D, it is indicated that in nursing service performance process, multiple factors lowing nursing service quality were intruded. So it needs further research to analysis what these factors are and how each factors affect on nursing performance process. 4. nursing service quality measurement is changeable according to sample select time or sampled subject's characteristics. So to develope strategy for nursing service quality improvement is based on the results of periodical analysis.

  • PDF

Derivations of Surface Solar Radiation from Polar Orbiting Satellite Observations (극궤도 위성 관측을 이용한 지표면에서의 태양 복사에너지 도출)

  • Kim, Dong-Cheol;Jeong, Myeong-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.3
    • /
    • pp.201-220
    • /
    • 2016
  • In this study, the net solar radiation fluxes at the surface are retrieved by updating an existing algorithm to be applicable for MODerate resolution Imaging Spectroradiometer (MODIS) observations, in which linear relationships between the solar radiation reflected from the top of atmosphere and the net surface solar radiation are employed. The results of this study have been evaluated through intercomparison with existing Clouds and the Earth's Radiant Energy System (CERES) data products and ground-based data from pyranometers at Gangneung-Wonju National University (GWNU) and the Southern Great Plains (SGP) of observatory of Atmospheric Radiation Measurement (ARM) site. Prior to the comparison of the surface radiation energy in relation to the energy balance of the earth, the radiation energy of the upper part of the atmosphere was compared. As a result, the coefficient of determination was over 0.9, showing considerable similarity, but the Root-Mean-Square-Deviation (RMSD) value was somewhat different, and the downward and net solar-radiation energy also showed similar results. The surface solar radiation data measured from pyranometers at Gangneung-Wonju National University (GWNU) and Atmospheric Radiation Measurement (ARM) observatory are used to validate the solar radiation data produced in this study. When compared to the GWNU, The results of this study show smaller RMSD values than CERES data, showing slightly better agreements with the surface data. On the other hand, when compared with the data from ARM SGP observatory, the results of this study bear slightly larger RMSD values than those for CERES. The downward and net solar radiation estimated by the algorithm of this study at a high spatial resolution are expected to be very useful in the near future after refinements on the identified problems, especially for those area without ground measurements of solar radiation.

Dredging Bottom Sediments of Seoha Weir at the Downstream of Kyongan Stream can be Used as a Feasible Pollutant Load Reduction Option in the Total Pollutant Load Management System of Kwangju City? (경안천 서하보 수저퇴적물 준설이 경기도 광주시 수질오염총량관리에 있어 추가적인 부하량 삭감수단으로써 타당한가?)

  • Yu, Seung-Hoon;Lee, Bum-Yeon;Lee, Kang-Hyun;Park, Shin Jung;Lee, Chang-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.19-29
    • /
    • 2011
  • In order to assess the influences of bottom sediment on water quality, following measurement were made. (1) Estimations of pollutant loads from the bottom sediment based on mass balance concept, (2) measurements of pollutant concentrations in the sediment to assess the pollution level and influence potential, (3) in situ and laboratory measurements of Sediment Oxygen Demants (SOD) and pollutant load (sediment release) from bottom sediment. Analyses of inflow and outflow loadings using simple mass balance show that there are some variations found according to the pollutants. However, there is no consistent evidence that the sediment can be a source of pollutants. Pollutant concentrations in the sediment range 16~724.8 mg/kg (COD), 1.68 ~12.64 mg/kg (T-P), 5.6~76.8 mg/kg (T-N), 0.32~21.6 mg/kg ($NH_3$-N), 0.092~0.544 mg/kg ($NO_2$-N), 4.8~18.4 mg/kg ($NO_3$-N), and 1.59~11.23 mg/kg ($PO_4$-P). Measured SOD ranges $0.190{\sim}0.802g{\cdot}m^{-2}{\cdot}d^{-1}$ and measured release rate ranges $-1618.42{\sim}10mg/m^2{\cdot}d$(COD), $-12{\sim}16mg/m^2{\cdot}d$(T-P), $-197.37{\sim}140mg/m^2{\cdot}d$(T-N), $0.4{\sim}74.32mg/m^2{\cdot}d$($NH_3$-N), $-2.04{\sim}0.8mg/m^2{\cdot}d$ ($NO_2$-N), $-70{\sim}40mg/m^2{\cdot}d$ ($NO_3$-N), and $-26.11{\sim}28.55mg/m^2{\cdot}d$($PO_4$-P). All study results indicate that bottom sediments in the Seoha weir show only limited effects on the water quality. It implies that sediment dredging is not an effective option or management measure to reduce pollutant loading.

Errors in Net Ecosystem Exchanges of CO2, Water Vapor, and Heat Caused by Storage Fluxes Calculated by Single-level Scalar Measurements Over a Rice Paddy (단일 높이에서 관측된 저장 플럭스를 사용할 때 발생하는 논의 이산화탄소, 수증기, 현열의 순생태계교환량 오차)

  • Moon, Minkyu;Kang, Minseok;Thakuri, Bindu Malla;Lee, Jung-Hoon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.3
    • /
    • pp.227-235
    • /
    • 2015
  • Using eddy covariance method, net ecosystem exchange (NEE) of $CO_2$ ($F_{CO_2}$), $H_2O$ (LE), and sensible heat (H) can be approximated as the sum of eddy flux ($F_c$) and storage flux term ($F_s$). Depending on strength and distribution of sink/source of scalars and magnitude of vertical turbulence mixing, the rates of changes in scalars are different with height. In order to calculate $F_s$ accurately, the differences should be considered using scalar profile measurement. However, most of flux sites for agricultural lands in Asia do not operate profile system and estimate $F_s$ using single-level scalars from eddy covariance system under the assumption that the rates of changes in scalars are constant regardless of the height. In this study, we measured $F_c$ and $F_s$ of $CO_2$, $H_2O$, and air temperature ($T_a$) using eddy covariance and profile system (i.e., the multi-level measurement system in scalars from eddy covariance measurement height to the land surface) at the Chengmicheon farmland site in Korea (CFK) in order to quantify the differences between $F_s$ calculated by single-level measurements ($F_s_{-single}$ i.e., $F_s$ from scalars measured by profile system only at eddy covariance system measurement height) and $F_s$ calculated by profile measurements and verify the errors of NEE caused by $F_s_{-single}$. The rate of change in $CO_2$, $H_2O$, and Ta were varied with height depending on the magnitudes and distribution of sink and source and the stability in the atmospheric boundary layer. Thus, $F_s_{-single}$ underestimated or overestimated $F_s$ (especially 21% underestimation in $F_s$ of $CO_2$ around sunrise and sunset (0430-0800 h and 1630-2000 h)). For $F_{CO_2}$, the errors in $F_s_{-single}$ generated 3% and 2% underestimation of $F_{CO_2}$ during nighttime (2030-0400 h) and around sunrise and sunset, respectively. In the process of nighttime correction and partitioning of $F_{CO_2}$, these differences would cause an underestimation in carbon balance at the rice paddy. In contrast, there were little differences at the errors in LE and H caused by the error in $F_s_{-single}$, irrespective of time.

Intercomparison of Chamber Methods for Soil Respiration Measurement in a Phytotron System (식물 환경 조절 시스템에서의 토양 호흡 관측 챔버법의 비교 실험)

  • Chae Namyi;Kim Rae-Hyun;Hwang Taehee;Suh Sang-Uk;Lee Jae-Seok;Son Yowhan;Lee Dowon;Kim Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.107-114
    • /
    • 2005
  • Soil CO₂ emission is one of the primary components in carbon balance of terrestrial ecosystems. In soil CO₂ flux measurements, chamber method is currently the most common technique. Prior to compare or synthesize the data collected from different chamber methods, potential biases must be quantified for each measurement system. We have conducted an intercomparison experiment among four closed dynamic chamber systems and an automatic open-closed chamber system in a temperature-controlled phytotron. Due to the disturbed CO₂ concentrations inside the phytotron during the measurements with closed dynamic chambers and the changes in soil water content, the interpretation of the data was difficult to quantify the biases of individual methods. However, the experiment provided not only valuable information on the performance characteristics of the five instruments to varying soil temperature and CO₂ concentration but also useful insights for better designs and strategy for future intercomparison in a controlled environment.

Activity and Safety Recognition using Smart Work Shoes for Construction Worksite

  • Wang, Changwon;Kim, Young;Lee, Seung Hyun;Sung, Nak-Jun;Min, Se Dong;Choi, Min-Hyung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.654-670
    • /
    • 2020
  • Workers at construction sites are easily exposed to many dangers and accidents involving falls, tripping, and missteps on stairs. However, researches on construction site monitoring system to prevent work-related injuries are still insufficient. The purpose of this study was to develop a wearable textile pressure insole sensor and examine its effectiveness in managing the real-time safety of construction workers. The sensor was designed based on the principles of parallel capacitance measurement using conductive textile and the monitoring system was developed by C# language. Three separate experiments were carried out for performance evaluation of the proposed sensor: (1) varying the distance between two capacitance plates to examine changes in capacitance charges, (2) repeatedly applying 1 N of pressure for 5,000 times to evaluate consistency, and (3) gradually increasing force by 1 N (from 1 N to 46 N) to test the linearity of the sensor value. Five subjects participated in our pilot test, which examined whether ascending and descending the stairs can be distinguished by our sensor and by weka assessment tool using k-NN algorithm. The 10-fold cross-validation method was used for analysis and the results of accuracy in identifying stair ascending and descending were 87.2% and 90.9%, respectively. By applying our sensor, the type of activity, weight-shifting patterns for balance control, and plantar pressure distribution for postural changes of the construction workers can be detected. The results of this study can be the basis for future sensor-based monitoring device development studies and fall prediction researches for construction workers.

A Case Report of Olivopontocerebellar Atrophy (Multiple Systemic Atrophy-Cerebellum) Patient Complicating Sleep Disorders and Gait Disturbance (수면장애와 보행장애를 호소하는 올리브교소뇌위축증 환자 증례보고 1례)

  • Lee, Su-yeong;Kim, Du-ri;Lee, Hyun-seung;Chae, Han-nah;Yun, Jong-min;Moon, Byung-soon
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.802-813
    • /
    • 2018
  • This case report describes a patient with olivopontocerebellar atrophy accompanied by sleep disorder and gait disturbance whose condition was improved by treatment with Korean medicine. The 61-year-old woman, who was diagnosed with olivopontocerebellar atrophy (Multiple Systemic Atrophy-Cerebellum), was admitted to hospital twice and treated with Korean medicine (acupuncture and herbal medicine) and rehabilitation. The Korean medicine was Gwibiondam-tang-gami and Jaeumgeonbi-tang-gami. Clinical symptoms were assessed by the Modified Bathel index, functional independent measurement, Berg balance scale, and Unified Multiple System Atrophy rating scale. A brain MRI at the one-year follow up after onset showed similar progress but clinical symptoms were improved after treatment, and the evaluation index score increased. Multiple system atrophy, a type of degenerative neurological disease, has no targeted treatment. In this situation, although this report describes a single case, Korean medicine treatment could provide a meaningful improvement in the sleep disturbance and gait disorder symptoms of patients with olivopontocerebellar atrophy.

Validation of Energy and Water Fluxes Using Korea Land Data Assimilation and Flux Tower Measurement: Haenam KoFlux Site's Hydro-Environment Analysis (Flux Tower 관측자료와 KLDAS를 이용한 Soil-Vegetation-Atmosphere Transfer 모형의 적용:해남 KoFlux 지점의 수문순환 환경분석에 대하여)

  • Kim, Daeun;Lim, Yoon Jin;Lee, Seung Oh;Choi, Minha
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3B
    • /
    • pp.285-291
    • /
    • 2011
  • Accurate assessment of the water and energy cycles is essential to understand hydrologic, climatologic, and ecological processes. Common Land Model (CLM) is one of the well-developed Soil-Vegetation-Atmosphere Transfer (SVAT) models based on the water and energy balance equation for accurate prediction of hydro-environmental cycles. The CLM can estimate realistic and reliable results using relatively simple parameters. It has been widely used in the world, however in Korea practical applications of the CLM are rare due to lack of information and input data. In this study, the CLM with Korea Flux network (KoFlux) and Kore Land Data Assimilation System (KLDAS) data were individually validated for domestic applications. This study showed that all comparisons between observations and model results from KoFlux and KLDAS had reasonable correlation with determination coefficient of 0.73~1.00 via regression. The results confirmed the applicability of the CLM and the possibility of the KLDAS usage for the region where input data are not existed.