• Title/Summary/Keyword: balance measurement system

Search Result 180, Processing Time 0.036 seconds

Evaluation of nuclear material accountability by the probability of detection for loss of Pu (LOPu) scenarios in pyroprocessing

  • Woo, Seung Min;Chirayath, Sunil S.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.198-206
    • /
    • 2019
  • A new methodology to analyze the nuclear material accountability for pyroprocessing system is developed. The $Pu-to-^{244}Cm$ ratio quantification is one of the methods for Pu accountancy in pyroprocessing. However, an uncertainty in the $Pu-to-^{244}Cm$ ratio due to the non-uniform composition in used fuel assemblies can affect the accountancy of Pu. A random variable, LOPu, is developed to analyze the probability of detection for Pu diversion of hypothetical scenarios at a pyroprocessing facility considering the uncertainty in $Pu-to-^{244}Cm$ ratio estimation. The analysis is carried out by the hypothesis testing and the event tree method. The probability of detection for diversion of 8 kg Pu is found to be less than 95% if a large size granule consisting of small size particles gets sampled for measurements. To increase the probability of detection more than 95%, first, a new Material Balance Area (MBA) structure consisting of more number of Key Measurement Points (KMPs) is designed. This multiple KMP-measurement for the MBA shows the probability of detection for 8 kg Pu diversion is greater than 96%. Increasing the granule sample number from one to ten also shows the probability of detection is greater than 95% in the most ranges for granule and powder sizes.

Development of a Somatosensory Stimulation System for the Improvement of Postural Stability (자세 안정성 개선을 위한 체성감각 자극 시스템 개발)

  • Yu, Mi;Eun, Hye-In;Piao, Yong-Jun;Kim, Dong-Wook;Kwon, Tae-Kyu;Kim, Nam-Gyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.9
    • /
    • pp.843-850
    • /
    • 2007
  • This paper proposes a somatosensory stimulation system for the improvement of postural stability using vibration as somatosensory stimulation. This system consists of vibratory stimulation and postural response measurement. To evaluate this system, the center of pressure(COP) was closely observed in turn with simultaneous or separate mechanical vibratory stimulations to flexor ankle muscles (tibialis anterior, triceps surae) and two plantar zones on both feet while standing on a stable and an unstable support. The simultaneous vibratory stimulations cleared influenced postural stability and the effects of vibrations were higher with the unstable support. In separate vibratory stimulations, the extent of the COP sway reduced when the direction of the vibratory stimulations and that of the inclination of body coincided for flexor ankle muscle stimulations. In the contrary, the extent of the COP sway increased when the direction of the stimulations and that of body inclination coincided for plantar zone stimulations. These results can be useful for the development of rehabilitation systems that utilizes somatosensory inputs for postural balance.

The Study on a Real-time Flow-rate Calculation Method by the Measurement of Coolant Pump Power in an Integral Reactor (일체형원자로에서 냉각재펌프의 전력측정을 이용한 실시간 유량산정 방법에 관한 연구)

  • Lee, J.;Yoon, J.H.;Zee, S.Q.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.161-166
    • /
    • 2003
  • It is the common features of the integral reactors that the main components of the RCS are installed within the reactor vessel, and so there are no any flow pipes connecting the coolant pumps or steam generators. Due to no any flow pipes, it is impossible to measure the differential pressure at the RCS of the integral reactors, and it also makes impossible measure the flow-rate of the reactor coolant. As a alternative method, the method by the measurement of coolant pump power has been introduced in this study. Up to now, we did not found out a precedent which the coolant pump power is used for the real-time flow-rate calculation at normal operation of the commercial nuclear power plants. The objective of the study is to embody the real-time flow-rate calculation method by the measurement of coolant pump power in an integral reactor. As a result of the study, we could theoretically reason that the capacity-head curve and capacity-shaft power curve around the rated capacity with the high specific-speeded axial flow pumps have each diagonally steep incline but show the similar shape. Also, we could confirm the above theoretical reasoning from the measured result of the pump motor inputs, So, it has been concluded that it is possible to calculate the real-time flow-rate by the measurement of pump motor inputs. In addition, the compensation for a above new method can be made by HBM being now used in the commercial nuclear power plants.

  • PDF

Comparison of the CO2 Emission Estimation Methods in a LNG Power Plant Based on the Mass Balance Approach (물질수지 방법을 고려한 액화천연가스 발전소에서의 온실기체 배출량 산정 방법 비교)

  • Kim, Hee-Jin;Yeo, Min Ju;Kim, Yong Pyo;Jang, Geon Woo;Shin, Won Geun;Lee, Myung Hwoon;Choi, Hyung Wook
    • Journal of Climate Change Research
    • /
    • v.4 no.3
    • /
    • pp.235-244
    • /
    • 2013
  • Carbon dioxide emission estimation methods consist of four tiers according to the IPCC guideline. In this study, estimated results by tier 3 and tier 4 were compared with the theoretically calculated $CO_2$ emissions based on the mass balance approach for a gas fired power plant between March and May 2011. It was found that the relative differences were upto 17% between the measured emissions by tier 4 and theoretically estimated emissions, while the results of tier 3 were similar to those from theoretically estimated ones. The comparisons suggested the possibility of misestimation due to replacing missing, abnormal, or invalid data in continuous emissions monitoring system. When using only the data without those missing, abnormal, or invalid data, the relative differences decreased somewhat but still showed consistent differences depending on the stack. It is suggested that this differences might be due to the accuracy of the measurement instruments for the tier 4, especially, for the flow rate measurement instrument.

A Study on the Improvement of Amending Process and Depreciation Measurement Method of the Standard Estimating System (건설공사 표준품셈 제.개정 프로세스 개선 및 손율산정방안에 관한 연구)

  • Ahn, Ji-Sung;Lee, Jeong-Ho;Kim, Young-Suk;Han, Seung-Woo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.481-486
    • /
    • 2008
  • Standard Estimating System, which can be used for estimating a construction cost, has been pointed out having some problems such as non-reflecting a variety of construction environments and site conditions, non-adapting new technologies and methods since it was established in 1970. For solving these problems, the Korean Institute of Construction Technology(KICT) has chosen organizations for amending Standard Estimating System. However they have had many mistakes in the process of amending works because of non-establishing amending process and absence of the depreciation measurement method. This research derived the necessity to improve the amending process of the Standard Estimating System, and presented the detailed amending process and the performing method in the each process. Furthermore, this research proposed the depreciation measurement method available for the construction industry by means of analyzing researches that performed in the manufacturing industry and the measurement method for depreciation of general accounts.

  • PDF

The Concept and Clinical Application for the Measurement of Heart Rate Variability (심박동수 변이(Heart Rate Variability) 측정법의 개념과 임상적 활용)

  • Woo, Jong-Min
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.12 no.1
    • /
    • pp.3-14
    • /
    • 2004
  • In this article, the effects of stress on central nerve system and heart function and the concept of heart rate variability were reviewed. HRV(Heart Rate Variability), the periodical change of the heart rate, is indicated larger in the healthier because they respond flexibly to various sorts of facts influencing on HR. HRV analysis is largely composed of the time domain analysis and the frequency analysis. In the former the flexibility of heart function is analysed, while in the latter autonomic nerve function is examined, which is the degree of sympathetic and parasympathetic nerve activity and the state of balance. Furthermore, existence or nonexistence of disease and/or level of stress can be estimated by measuring the variability and normality of heart rate, and balance of autonomic nerve system, and through HRV biofeedback the symptoms of anxiety disorder or asthma can be reduced.

  • PDF

Design and Implementation of Occlusion Force Analysis Software for Malocclusion Diagnosis : A Pilot Study (부정교합 진단을 위한 교합력 분석 소프트웨어의 설계 및 구현 : A Pilot Study)

  • Park, Kyoung-Jong;Kim, Tae-Yun;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.1
    • /
    • pp.147-155
    • /
    • 2009
  • Occlusion force measuring and analysis is a diagnostic method of tooth dynamics through the related force analysis. In this paper, we design and implement a series of occlusion force measuring software and evaluate its utility as a base system for a new occlusion force measure and analysis system development. For the reason, we developed a group of tools to measure the normal and abnormal occlusion force. Firstly, we have visualized the occlusion force distribution with quantitative figures. The center of force (COF) variation was visualized the path of marker according to teeth dynamics and the distribution of occlusion forces in 14 tooth regions. Secondly, we have implemented a left and right tooth force balance measurement ratio tool to estimate a specific tooth region force. Furthermore, the measured occlusion force variation recorded in the software each 0.5 second. As the result of the physical examination by the accessed hardware of sensor sheet method, we confirmed the distribution and balance of forces effectively.

  • PDF

A Clinical Report about Panic Disorder Patient imporved by Stress Reduction Program (SRP(Stress Reduction Program)을 적용하여 호전된 공황장애 48세 남환 치험 1례)

  • Suh, Jin-Woo;Kim, Jong-Woo;Chung, Sun-Yong;Park, So-Jung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.18 no.3
    • /
    • pp.157-164
    • /
    • 2007
  • The SRP program(stress reduction program) is reported has a good effect to patient to escape from anxiety. To reduce several symptoms due to anxiety, we performed some SRP programs to our patient who had suffered anxiety disorder. The measurement tools of patient's improvement we used are Heart Rate Variability and State-Trait Anxiety Inventory. Through this programs, symptoms and feeling of anxiety were decreased than first time and Autonomic nerve system balance was much improved. this is caused by effort of self-control meditation, mindfullness, breathing instruction and muscle relaxation program.

  • PDF

Comparative study of CP(center of pressure) Pattern on pitching sort in Softball (소프트볼 투구 구질에 따른 압력중심 이동패턴의 차이점 분석)

  • Moon, Young-Jin;Kim, Jin-Gyong
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.183-188
    • /
    • 2006
  • This research is to know differentiation of CP(center of pressure) pattern among four pitching sort(straight ball, raise ball, change up ball, drop ball). Subject are three national or junior athletes. We use the one camera, Novel Win pressure measurement system. Conclusions are as follows : 1. When we throw the straight ball, CP of left foot is effective to end movement at middle of foot in body balance on arm angular motion and enhanced speed. 2. When we throw the raise ball, to change CP from middle to post is more effective in order to raise the ball. 3.In drop ball pitching, in order to fall down the ball in front of hitter, CP of left foot move from post foot to interior part of forefoot 4. In change up ball pitching, if CP of left foot move into forefoot, it is a cause of high ball and hitter can recognize the change up ball because of late arm rotation motion.

An experimental study on friction measurement of piston-ring assembly of a SI engine (가솔린 기관의 피스톤-링 결합체 마찰력 측정에 관한 실험적 연구)

  • 이동원;윤정의;김승수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.4
    • /
    • pp.66-74
    • /
    • 1990
  • Friction between piston-ring assembly and cylinder wall of a spark ignition engine was evaluated under various engine operating conditions utilizing a grasshopper linkage system. The friction force was estimated by the force balance relation at the small end of connecting rod. Three forces were chosen to be measured for the objective. They were gas pressure inside the cylinder, inertia force of the piston-ring assembly, and the force exerted by the connecting rod. These forces were measured by a piezo type pressure sensor, an accelerometer and strain gauges, respectively. Comparisons were made with the frictional force evaluated by the conventional method where the assumption of constant rotational speed of engines was adopted. Due to the variation of rotational speed of engines, the conventional method was found to lead to a large error in the evaluation of the frictional force.

  • PDF