• Title/Summary/Keyword: bag

Search Result 1,614, Processing Time 0.025 seconds

Characteristics of Cyclone-Bag Filter with Bottom Inlet (하부유입식 원심 여과집진장치의 특성)

  • Yoa, Seok-Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.639-650
    • /
    • 2000
  • The main object of this study was to investigate experimentally the characteristics of cyclone-bag filter with bottom inlet to decrease the high pressure drop which was one of main problems of fabric bag filter. The experiment was executed for the analysis of collection efficiency and pressure drop(specially, pressure drop of fabric filter) characteristics of the cyclone-bag filter in comparison with those of general fabric bag filter with various experimental parameters such as the inlet velocity, dust loading and variation of vortex region, etc. In the results, the tangential inlet type showed higher collection efficiency for submicron particles below $1{\mu}m$ in diameter than of center inlet, and over 99% for overall collection efficiency. For the inlet particle concentration $100mg/m^3$, pressure drop reduction ratios were shown as 15~38% with the inlet velocity in case of large bag, while 30~48% for small bag due to the increase of vortex region.

  • PDF

On the Hydrodynamic Forces acting on a Partially Submerged Bag (부분적으로 물에 잠긴 백에 작용하는 유체역학적 힘)

  • G.J. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.4
    • /
    • pp.104-113
    • /
    • 1992
  • The hydrodynamic problem is treated here when a pressurized bag is submerged partially into water and the end points of it oscillate. SES(Surface Effect Ship)has a bag filled with pressurized air at the stern in order to prevent the air leakage, and the pitch motion of SES is largely affected by the hydrodynamic force of the bag. The shape of a bag can be determined with the pressure difference between inside and outside. Once the hydrodynamic pressure is given, the shape of a bag can be obtained, however in order to calculate the hydrodynamic pressure we should know the shape change of the bag, and vice versa. Therefore the type of boundary condition on the surface of a bag is a moving boundary like a free surface boundary. In this paper, the formulation of this problem was done and linearized. The calculation scheme for the radiation problem of an oscillating bag is shown in comparison with the case that the bag is treated as rigid body. The hydrodynamic forces are calculated for various values of the pressure inside the bag and the submerged depth.

  • PDF

Hip Protector against the Impact by Fall Using Air-bag (에어백을 이용한 신체충격완화장치)

  • Park, Ji-Soo;Kim, Choong-Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.639-643
    • /
    • 2012
  • The hip protector has been developed using the air-bag which has the capability of attenuating an impact. The impact force using the PVC air-bag was decreased by values of 27.5% on average, compared to the impact force without the air-bag. In the experiment, the standard deviation of the impact force attenuation rate was 0.78%. It means that the dimensions of the air-bag have no significant effects to reduce the impact. We believe that it is possible to design light and cheap hip protectors with air-bag to prevent the femur fracture.

Characteristics of Electrostatic Cyclone-Bag Filter with Upper Inlet (상부유입식 전기 Cyclone-Bag Filter의 특성)

  • 여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.179-190
    • /
    • 2000
  • The main object of this study was to investigate experimentally the characteristics of electrostatic cyclone-bag filter with upper tangential inlet in order to overcome the low collection efficiency for the submicron particle and high pressure drop which were main problems of general fabric bag filters. The experiment was carried out for the analysis of collection efficiency and pressure drop of electrostatic cyclone-bag filter comparing to those of fabric bag filter with various experimental parameters such as the inlet velocity(filtration velocity) and applied voltage etc. In the results the upper tangential inlet type showed higher collection efficiency for submicron particles below 2 ${\mu}{\textrm}{m}$ in diameter than that of center inlet and over 99.9% for overall collection efficiency. Pressure drop reduction ratios were shown as 40-50% for the applied voltage 0kV by centrifugal force and 70-90% for 20k V by the centrifuga and electrostatic force with the tangential inlet velocity (12-21m/s)

  • PDF

Storage Period of Milled Rice by Packaging Materials and Storage Temperature (온도와 포장재에 따른 백미의 저장가능기간)

  • Choi Yoon-Hee;Choung Jin-Il;Cheong Young-Keun;Kim Young-Doo;Ha Ki-Yong;Ko Jae-Kwon;Kim Chung-Kon
    • Food Science and Preservation
    • /
    • v.12 no.4
    • /
    • pp.310-316
    • /
    • 2005
  • This study was carried out to investigate the quality characteristics by packaging materials and storage temperature to predict safe storage period for milled rice. Mechanical taste value and whiteness of milled rices stored at room temperature were severely decreased than those of the stored at low temperature, but fat acidity and b value of those at room temperature was rapidly increased than those of stored at low temperature. Milled rice packed in LDPE film bag were smelled stale flavor after 4 months storage at room temperature, Hojinbyeo was not produced flour in the rice grain surface but Dongjinbyeo was showed production of flour. pH of milled rice of Dongjinbyeo and Hojinbyeo packed in LDPE film bag were the lowest showing 5.3 and 5.6, respectively after 6 months at mom temperature. Safe storage period of Dongjinbyeo and Hojinbyeo packed in craft paper bag were 1 month at room temperature, those of packed in LDPE film bag were 2 months. At low temperature safe storage period of Dongjinbyeo and Hojinbyeo packed in craft paper bag were 2 months, those of packed in LDPE film bag were 5 and 4 months, respectively.

Measurements of Trimethylamine (TMA) in air by Tedlar bag sampling and SPME analysis (환경대기 중 Trimethylamine (TMA)의 측정: Tedlar bag 방식의 채취와 SPME 분석법의 특성 연구)

  • Kim, K.H.;Hyum, S.H.;Im, M.S.
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.96-102
    • /
    • 2006
  • Trimethylamine (TMA) is one of the difficult odorous compounds for the collection and analysis. Although sulfuric acid absorption and/or sulfuric acid impregnated filter method are commonly recommended for its sampling, these methods also suffer from difficulties involved in sample treatment and operational procedures. Hence, as an ancillary approach to measure TMA, we investigated the combination of bag sampling and SPME analysis for TMA measurements. For the purpose of our study, we investigated the following three subjects: 1) temporal variability of standard storage, 2) bag loss effect of TMS, and 3) TMA loss due to repetitive analysis of an identical bag sample. According to our storage test up to 7 or 20 dyas, TMA loss were found to occur up to 40 to 50% within relatively short period of up to 48 hrs depending on its concentration ranges. When the tests were made for bag loss by transferring TMA standards across different size bags, we were able to find that the extent of bag loss are not significant with 5 to 20% loss rate. Finally, the TMA sorptive loss via its exposure to SPME fiber was generally estimated to run from 2 to 3%.

Filtration Performance Characteristics according to Filter Bag Structure for Application of Industries (산업용 필터백의 구조에 따른 여과성능 특성)

  • Jeon, Seong-Min;Hasolli, Naim;Lee, Kang-San;Lee, Jea-Rang;Kim, Kwang-Deuk;Park, Young-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.4
    • /
    • pp.384-393
    • /
    • 2016
  • In this study, two kinds of industrial filter bags were tested for their filtration performance to apply the existing bag filter systems. Experimental variables were examined for pressure drop, cleaning interval, residual pressure drop, cleaning efficiency, fractional grade efficiency, total collection efficiency according to the filter bag structure. According to these results, the filter bags tested in this study demonstrated good performance in dust collection. This was also true for the double surface filter bag. The lifetime was longer than the round type filter bag because the filtration area was more than 1.6 times wider and the filter quality factor was much higher. Therefore, double surface filter bags are suggested to be used in order to increase filtration performance of the bag filter systems.

Silk Reelability of the Cocoon Stored in a Pelyethylene Bag (Polyethylene대 저견이 조사에 미치는 영향)

  • 최병희;송기언
    • Journal of Sericultural and Entomological Science
    • /
    • v.6
    • /
    • pp.31-33
    • /
    • 1966
  • This work has been carried out for many months to check whether polyethylene bag cocoon storging method bring better reeling result against the normal cotton bag storing method. The obtained results were as followings. 1. The pupa killed cocoons could be stored on the ground in case of packing in polyethylene-bag until the secondary dry process. 2. The raw silk percentage of cocoon stored in polyethylene bag, increased 0.5% than the cotton bag storing method, not because of its reelability, but because of the better yield of cocoon bave. 3. Musty cocoon was not shown during the polyethylene hag storage, but the cocoons were attacked by rats as usually. 4. Polyethylene bag storing method invited more insects attack than the normal method, but the attack was able to cease by enclosing two naphthalene tablets in each bag.

  • PDF

Analysis of Contact Pressure for a 300mm Wafer Polishing Table with Air-Bag Head (Air-Bag Head 가압식 300mm 웨이퍼 폴리싱 테이블의 가압 분포 해석)

  • Ro, Seung-Kook
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.310-317
    • /
    • 2013
  • In this paper, the contact pressure of the wafer and polishing pad for final polishing process for 300 mm-wafer were investigated through numerical analysis using FEM tool, ANSYS. The distribution of the contact pressure is one of main parameters which affects on the flatness and surface roughness of polished wafers. Two types of polishing head, a hard type head with ceramic disk and a soft type head with air bag were considered. The effects of the deformation and initial shape of table on the contact pressure were also examined. Both heads and tables were modeled as 3D finite element model from solid model, and the material properties of polishing pads and rubber plate for the air-bag head were obtained from tensile tests. The contact pressure deviation on wafer surface was smaller with air bag head than hard type head even when the table had form errors such as convex or concave. From this 3D analysis, it could be concluded that the air-bag head has better uniformity of the contact pressure on wafer. Also, the effects of inner diameter of air bag and radial clearance between wafer and retainer were investigated as view point of contact pressure concentration on the edge of wafer.

Comparison of tidal volume of two different bag squeezing techniques in endotracheal intubation settings (기관내 삽관 후 백 압착법에 따른 호흡량 비교)

  • Kang, Min-Ju;Tak, Yang-Ju
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.1
    • /
    • pp.99-109
    • /
    • 2017
  • Purpose: There is no recommended bag-squeezing technique for emergency medical providers to maintain correct tidal volume during mechanical ventilation. This study compared the tidal volume of two different bag-squeezing techniques during mechanical ventilation. Methods: The subjects were 38 paramedic students who were trained in airway management techniques. Two different bag-squeezing techniques were used with a bag valve mask on an intubated manikin: a conventional technique and a finger-marked, in which the bag is squeezed until the thumb and the middle finger come into contact. Hand size and grip strength were measured and analyzed statistically. Results: The mean tidal volumes for the finger-marked were significantly higher than those for the conventional technique ($542.6{\pm}35.92mL$ versus $338.0{\pm}111.15 mL$, p<.001). There was a correlation between the two techniques (Pearson $x^2=1.160$, p<.001). The subject's characteristics, including sex, hand size, and grip strength, showed no correlation with tidal volume. Conclusion: A finger-marked bag-squeezing technique provides adequate and correct tidal volumes during mechanical ventilation.