• Title/Summary/Keyword: baffle block

Search Result 14, Processing Time 0.023 seconds

Experimental Study on the Inflow and Outflow Structures of Hwasun Flood Control Reservoir (화순 홍수조절지의 유입유출 구조물에 대한 수리모형실험 연구)

  • Lee, Sang-Hwa;Jin, Kwang-Ho;Ryu, Jong-Hyun;Kim, Soo-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.7
    • /
    • pp.675-684
    • /
    • 2012
  • Recently, a heavy rainfall under climate change causes the flood exceeded river's conveyance. Flood control methods under the limited river width are the increase of embankment, the construction of storage pockets and diversion channel, the dredging of river bed. Hwasun flood control reservoir of washland is designed as the storage pockets and the regulating gate for the control of water level. In this study, the propriety of design was investigated through hydraulic experiments for the circumstances to exclude the constant flood discharge during operation period. In the results, the over flow rate of side weir exceeded the flow of design and indicated to be able to discharge the designed flow in the regulating gate opened 1.1 m. The high velocity 7.1 m/s behind the gate has investigated to reduce under 3.3 m/s by the baffle block.

Dynamic analysis of water storage tank with rigid block at bottom

  • Adhikary, Ranjan;Mandal, Kalyan Kumar
    • Ocean Systems Engineering
    • /
    • v.8 no.1
    • /
    • pp.57-77
    • /
    • 2018
  • The present paper deals with the finite element analysis of water tanks with rigid baffle. Fluid is discretized by two dimensional eight-node isoparametric elements and the governing equation is simulated by pressure based formulation to reduce the degrees of freedom in the domain. Both free vibration and force vibration analysis are carried out for different sizes and positions of block at tank bottom. The fundamental frequency depends on block height and it reduces with the increase of block height. The variation of hydrodynamic pressure on tank walls not only depends of the exciting frequency but also on the size and position of rigid block at tank bottom. The hydrodynamic pressure has higher value when the exciting frequency is equal and lower than the fundamental frequency of the water in the tank. Similarly, the hydrodynamic pressure increases with the increase of width of the block for all exciting frequencies when the block is at the centre of tank. The left and right walls of tank have experienced different hydrodynamic pressure when the block is placed at off-centre. However, the increase in hydrodynamic pressure on nearest tank wall becomes insignificant after a certain value of the distance between the wall and the rigid block.

Parametric Study of Instability in Obstructed Channel Flow (장애물이 부착된 평판 사이 유동의 불안정성에 관한 파라미터적 연구)

  • Hwang, In-Sang;Yang, Gyeong-Su;Kim, Do-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.546-553
    • /
    • 2001
  • A Parametric study is numerically carried out for flow fields in a two-dimensional plane channel with thin obstacles(“baffles and blocks”) mounted symmetrically in the vertical direction and periodically in the streamwise direction. The aim of this investigation is to understand how various geometric conditions influence the critical characteristics and pressure drop. A range of BR(the ratio of baffle interval to channel height) between 1 and 5 is considered. Especially when BR is equal to 3, for which the critical Reynolds number turned out to be minimal, we add blocks in the center region in order to study their destabilizing effects on the flows. It is revealed that the critical Reynolds number is further decreased by the presence of the block.

Numerical Study on Performance of PEMFC with Block and Sub-channel of Cathode Flow Field (캐소드 유로에서 블록과 서브 채널의 고분자전해질 연료전지의 성능에 관한 전산해석 연구)

  • Jo, Seonghun;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.613-620
    • /
    • 2021
  • A flow channel shape of PEMFC has an influence on the internal flow uniformity. If the reactant distribution in a flow path is not uniform during operation, both catalyst deactivation and mechanical damage of membrane could occur resulting in decreasing the membrane electrode assembly (MEA) durability. Numerous studies concerning flow design have been conducted to make smooth supply and uniform distribution of reactants in fuel cells. The baffle of flow path could improve fuel cell performance through the forced convection effect. A sub-channel, as an additional air flow path, could increase the reactant concentration and reduce the mass transfer loss via a smooth water discharge. In this study, computational fluid dynamics (CFD) was used to analyze the effect of blocks and sub-channels on the current density and oxygen concentration of the fuel cell. As a result, the limit current density and oxygen concentration at a rear block increased when using blocks and sub-channels in a flow channel. In particular, the current density increased significantly when the sub-channel was placed between two blocks. Also, the sub-channel position was optimized by analyzing the oxygen concentration, and the oxygen concentration was recovered at a rear block in the fuel cell.

Corrective surgery of double outlet right ventricle: an analysis of 27 cases (양대동맥 우심실 기시증 [Double Outlet Right Ventricle] 의 전교정술 -27례 분석-)

  • 조재일
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.349-355
    • /
    • 1983
  • Twenty-seven patients with double-outlet right ventricle underwent complete intracardiac repair between 1978 and 1983, June, at Seoul National University Hospital . Although definite aorto-mitral discontinuity was discovered in 20 patients, both great arteries arose wholly or mostly from the right ventricle in all cases. There were 17 cases with subaortic VSD, 6 with subpulmonic, 2 with doubly-committed, and 2 with non-committed VSD. Pulmonary stenosis was present in 21 patients. Intraventricular baffle repair was applied in 23 patients. Three patients required extracardiac conduit to establish continuity between right ventricle and pulmonary artery, and modified Fontan operation was performed in one patient. Over-all mortality rate was 37.0%, but recently 4 of 15 died [26.7%]. One late death occurred from infective endocarditis. Incremental risk factors were small patient size, subpulmonic or non-committed VSD, presence of PS, coronary artery anomalies, associated valvular lesion and other complicated anomalies. However, great artery relationship, restrictive VSD and transannular patch were not risk factors. No instances of complete heart block occurred. Of the survivors, all showed complete or in complete right bundle branch block and in one patient intermittent ventricular tachycardia had developed. The important cause of death was low cardiac output syndrome.

  • PDF

The design study of optics and opto-mechanics for Lyman-a sun camera of scientific satellite

  • Kim, Kil-Seon;Lee, J.G.;Lee, Y.H.;Rim, Cheon-Seog;Jang, Min-Hwan;Oh, Oh;Park, Jung-Sun;Lee, Woo-Yun;Kim, Geon-Hee
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2004.07a
    • /
    • pp.64-67
    • /
    • 2004
  • The optics and opto-mechanics are disigned for imaging the sun at Lyman-${\alpha}$ line for scientific satellite. The optics are composed of conic mirrors. In order to block stary light. the new baffle design method is suggested. And we will present the opto-mechanics for this scientific satellite.

  • PDF

Numerical Analysis for High Pressure Blast Flow Fields of a Silencer with Baffles (배플형 소음기가 적용된 고압 폭발 유동장에 대한 수치 해석)

  • Lee D. S.;Ko S. H.;Kang K. J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.169-172
    • /
    • 2005
  • A numerical analysis was made In investigate the pressure diminution of a silencer with baffles for high pressure blast flow fields. Reynolds-Averaged Navier-Stokes equations were solved for an axisymmetric computational domain constructed by multi block Chimera grids. A blast flow field was calculated for the silencers that are with one and three baffles. The evolution of high pressure blast flow fields was observed by depicting calculated contours of pressure. It was found that the tested silencer could achieve 97.7 percent pressure diminution.

  • PDF

A Numerical Analysis of the Baffled Silencer for the Noise Diminution of Tank Gun (전차포 소음 저감을 위한 배플형 소음기의 수치해석)

  • Ko, Sung-Ho;Lee, Dong-Su;Kang, Kuk-Jeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.3 s.258
    • /
    • pp.217-224
    • /
    • 2007
  • A numerical analysis for a silencer with three baffles of 120mm tank gun has been performed. The Reynolds-Averaged Wavier-Stokes equations with Baldwin-Lomax turbulence model were employed to compute unsteady, compressible flow inside the tank gun and the silencer. An axisymmetric computational domain was constructed by using 12 multi block chimera grids. The resolution of flow field is observed by depicting calculated pressure and muzzle brake force. The peak blast pressure and noise through the silencer reduced approximately 99% and 41dB in comparison to the tank gun without the silencer at near filed.

Determination of the Optimal Location of Baffle Blocks in the Sluice Gate (하단방류형 가동보 감세블록의 최적 위치 선정)

  • Cho, Sung Yoon;Jang, Dong Woo;Park, Hyo Seon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.361-361
    • /
    • 2015
  • 감세블록(baffle block)은 고속의 흐름에서 도수를 유도함으로써 과도한 에너지를 감세시키는 역할을 하는 구조물이며 구조물의 크기, 형태, 위치, 조합 등의 변수로 도수가 형성되는 조건을 조절하여 흐름에 영향을 줄 수 있다. 하단방류형 가동보에서 고속으로 방류되는 흐름의 Froude 수가 2.5에서 4.5 사이일 경우 발생하는 불규칙한 주기의 진동이 중첩 보강되면 감세하기 어려운 파동을 형성하여 수 Km 동안 지속될 수 있어 추가적인 조치가 필요하다(Peterka, 1984). 이 연구에서는 총 연장 11m, 폭 0.5m의 구형수로에 하단방류형 가동보와 감세블럭을 설치하여 감세블록의 위치가 에너지의 감세에 미치는 영향을 분석하고, 감세블록의 최적 위치를 제안하였다. 감세블럭은 높이 2cm, 폭 5cm의 구형단면으로 제작하여 일정한 간격으로 치형 배열하였으며, 가동보로 부터 5.5~8.5cm 지점에서 1cm간격으로 총 5가지 조건으로 수리실험을 수행하였다. 또한, 수문 하단에서의 Froude 수가 3.8~3.9를 만족하는 강한 도수가 발생할 수 있도록 유량을 조절 하였고, 유속과 수심은 3차원 유속계와 피에조미터를 이용하여 가동보로부터 0.2m간격으로 하류단 2m 지점까지 측정하였다. 실험 결과, 가동보로부터 도수가 발생하여 수위가 안정되는 지점까지의 도수길이는 감세블록을 설치한 경우, 설치하기 전의 1.1m와 비교하여 최소 27.3%에서 최대 81.8%만큼 짧아졌으며 감세블록 보에 가깝게 설치될수록 도수길이는 단축되는 것으로 나타났다. 가동보 하류부에서 도수가 발생한 이후 수심이 안정화되는 1m 지점에서, 도수 전후의 비에너지비로 정의되는 도수효율은 감세블록 미설치 시 74.9%이고, 감세블록이 설치된 조건에서는 54.9~60.6%로 감세블록에 의한 에너지 감소효과가 큰 것으로 나타났다. 에너지 감세 효과가 가장 큰 감세블록 위치는 가동보로부터 6.5cm 떨어진 곳으로 하류단 수심의 약 80%에 해당하는 지점이 감세블록의 최적 위치인 것으로 판단된다.

  • PDF

Complications after Senning Operation for TGA with and Wothout VSD (대혈관전위증에서 Senning수술후 합병증에 관한 임상적 고찰)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.595-603
    • /
    • 1993
  • We analysed 60 consecutive patients who got Senning operation for transposition of the great arteries [TGA] with or without ventricular septal defects [VSD]. There were 41 simple TGA [group I] and 19 TGA with VSD [Group II], the operative mortality was 20 % [in group I 4.9 %, group II 52.6 %]. Among the survivors [n=48], the mean follow-up period was 7 years [range, 1 year to 13.5 years] and the actuarial survival rate at 13 years were 95 % in group I and 42 % in group II. Preoperative high left ventricular pressure and high pulmonary arterial pressure affected the surviving [p<0.01]. There occurred various type of arrhythmia like junctional rhythm, first degree atrioventricular [AV] block, sick sinus syndrome and complete AV block, and we inserted 2 permanent pacemakers for these patients. The incidence of arrhythmia were 28.2 % [11/39] in group I and 55.6 % [5/9] in group II, and the actuarial freedom from arrhythmia at 13 years after operation was 66 % [71 % in group I, 44 % in group II]. Increased aortic cross clamping time had affected the development of arrhythmia [p<0.05] which meant the complexity of the operation. The total incidence of left ventricular outflow tract obstruction [LVOTO] was 31.3 % [15/48], but only 3 patients [6.25 %] showed the significant gradient requiring reoperation. The pulmonary venous pathway obstruction [PVO] were found in 3 patients, all in group I, and among them only one required the reoperation. The estimated freedom from PVO was 89 % at 13 years [87 % in group I, 100 % in group II], but we couldn`t find any significant systemic venous obstruction in our series. There occurred 27.1 % [13/48] mild degree tricuspid valve regurgitation without necessary surgical correction. We experienced 14.6 % [7/48] reoperation rate: 3 residual VSD, 3 LVOTO, 1 PVO, 3 atrial baffle leakage. For this high incidence of complication rate after Senning operation and high mortality in TGA with VSD, We do not use this kind of surgical modality any more and do the Jatene operation for all the TGA patients since several years ago.

  • PDF