• Title/Summary/Keyword: background noise

Search Result 965, Processing Time 0.028 seconds

Color Space Mapping and Medium Access Control Techniques in Visible Light Communication (가시광통신을 위한 색채공간매핑과 MAC 기법 연구)

  • Rahman, Mohammad Shaifur;Kim, Byung-Yeon;Bang, Min-Suk;Park, Young-Il;Kim, Ki-Doo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.99-107
    • /
    • 2009
  • Visible Light Communication (VLC) is a promising wireless communication technology. It offers huge, worldwide available and free bandwidth without electro-magnetic interference, which makes it very attractive for RF-sensitive operating environments. We propose colored LED-based VLC system for hospital use which includes voice recognition system for operating the medical equipments. New Mr hlation Scheme based on the Light Color Space is suggested to overcome the effect of noise generated by background light. Different color space constellations for different symbol sizes are also suggested which would give better bit error rate performance. Finally, Slotted ALOHA or TDMA medium access control protocols are suggested for multi-user operations.

  • PDF

Analysis of Sound Signal by Conducting Particle in Coaxial Cylindrical Electrodes (동축원통 전극내의 파티클에 의한 음향신호 분석)

  • 조국희;권동진;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.104-110
    • /
    • 1997
  • In thes paper, the soung signals due to the collisions against the inside wall by conductint particles with in coaxial cylindrical electrodes, and the corresponding frequency spectrum are analyzed and discribed.Thesesound signals were detected and measured using ultrasonic and vibration sensors attached to the exterior of the GIS enclosure. In the case where a particls is bouncing about between these coaxoal electrodes, the sound signal was found to be more than 10[dB] greater than the background noise due to no particlel. Also, in the case where a particle collides and insulation breakdown caesed by the particle made it possible to determine the condition of the insulation inside the sealed GIS. Lastly, the relationship between the peak amplitude and RMS voltage of the measured signal, the diameter and length of the particle was analyzed. Using thes analysis, it is possible to confirm the size of particle.

  • PDF

A Study on Face Recognition using Neural Networks and Characteristics Extraction based on Differential Image and DCT (차영상과 DCT 기반 특징 추출과 신경망을 이용한 얼굴 인식에 관한 연구)

  • 임춘환;고낙용;박종안
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8B
    • /
    • pp.1549-1557
    • /
    • 1999
  • In this paper, we propose a face recognition algorithm based on the differential image method-DCT This algorithm uses neural networks which is flexible for noise. Using the same condition (same luminous intensity and same distance from the fixed CCD camera to human face), we have captured two images. One doesn't contain human face. The other contains human face. Differential image method is used to separate the second image into face region and background region. After that, we have extracted square area from the face region, which is based on the edge distribution. This square region is used as the characteristics region of human face. It contains the eye bows, the eyes, the nose, and the mouth. After executing DCT for this square region, we have extracted the feature vectors. The feature vectors were normalized and used as the input vectors of the neural network. Simulation results show 100% recognition rate when face images were learned and 92.25% recognition rate when face images weren't learned for 30 persons.

  • PDF

Measurements of relative depth dose rates for a brachytherapy Ir-192 sourceusing an organic scintillator fiber-optic radiation sensor (유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의 상대 깊이 선량율 측정)

  • Shin, Sang-Hun;Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Seo, Jeong-Ki;Lee, Bong-Soo;Moon, Joo-Hyun;Kim, Sin;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.462-469
    • /
    • 2008
  • In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator and plastic optical fiber for brachytherapy dosimetry. Also, we have measured relative depth dose rates of Ir-192 source using a fiber-optic sensor and compared them with the results obtained using a conventional EBT film. Cerenkov lights which can be a noise in measuring scintillating light with a fiber-optic sensor are measured and eliminated by using of a background optical fiber. It is expected that a fiber-optic radiation sensor can be used in brachytherapy dosimetry due to its advantages such as a low cost, simple usage and a small volume.

Speech Enhancement Based on Feature Compensation for Independently Applying to Different Types of Speech Recognition Systems (이기종 음성 인식 시스템에 독립적으로 적용 가능한 특징 보상 기반의 음성 향상 기법)

  • Kim, Wooil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2367-2374
    • /
    • 2014
  • This paper proposes a speech enhancement method which can be independently applied to different types of speech recognition systems. Feature compensation methods are well known to be effective as a front-end algorithm for robust speech recognition in noisy environments. The feature types and speech model employed by the feature compensation methods should be matched with ones of the speech recognition system for their effectiveness. However, they cannot be successfully employed by the speech recognition with "unknown" specification, such as a commercialized speech recognition engine. In this paper, a speech enhancement method is proposed, which is based on the PCGMM-based feature compensation method. The experimental results show that the proposed method significantly outperforms the conventional front-end algorithms for unknown speech recognition over various background noise conditions.

Optimizing Cleaning Period of Oxide Etcher Using Optical Emission Spectroscopy (광방출 분석법을 이용한 산화물 식각 장비의 세정 주기 최적화)

  • Son, Gil-Su;Roh, Yong-Han;Yeom, Geun-Young;Kim, Su-Hong;Kim, Myoung-Woon;Cho, Hyung-Chul
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.416-421
    • /
    • 2011
  • In this paper, the relationship of chamber contamination and the intensity change of specific wavelength was investigated. "diff_CO" formula was introduced to rule out background noise caused by external conditions and to detect when the polymer is removed from the chamber. As RF time increased, diff_CO trend showed the decrease of the maximum peak and increased number of small intensity peaks. From the diff_CO change, it was possible to determine when the chamber needs to be cleaned without opening the chamber.

Quantitative Evaluation of Remote Field Eddy Current Defect Signals (배관 결함부 원거리장 와전류 신호 정량화 연구)

  • Jeong, Jin-Oh;Yi, Jae-Kyung;Kim, Hyoung-Jean
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.555-561
    • /
    • 2000
  • The remote field eddy current (RFEC) inspection was performed on the ductile cast iron pipes with nominal outer diameter of 100mm, which were machined with various shapes and sizes of defects. Ductile cast iron pipes which are used as water supply pipe have the non-uniform thickness and asymmetric cross section due to relatively high degree of allowable errors during the manufacturing processes. These characteristics of ductile cast in pipes cause the long range background noises in RFEC signals along the pipe. In this study, tile machined defects in pipes were effectively classified by the moving window average (MWA) method which eliminated the long-range noise. The voltage plane polar plots (VPPP) method was used to quantitatively evaluate the depth and circumferential degree of defects. The VPPP signatures showed that the angle between defect signature and the normalized in-phase component on the VPPP is linear to the depth of defects. The nondestructive RFEC technique proved to be capable of quantitatively evaluating the machined defects of underground water supply pipe.

  • PDF

585-nm Pulsed Dye Laser Treatment of Vocal Polyp (585-nm Pulsed Dye LASER를 이용한 성대 폴립의 치료)

  • Choi, Hong-Shik;Lee, Kun-Wayn;Kim, Min-Ho;Kwon, Soon-Ho;Jeon, Ju-Hyun;Kim, Kwang-Moon
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.18 no.1
    • /
    • pp.44-50
    • /
    • 2007
  • Background and Objectives: The 585-nm pulsed dye laser (PDL) has recently been adopted by otolaryngologists because of its epithelial-sparing properties. Many authors have reported the use of PDL for treatment of various vocal cord lesions. This purpose of this study is to examine the effectiveness of 585-nm PDL in the treatment of vocal polyp. Materials and Methods: Eight patients with vocal polyp were treated with 585-nm PDL from Sep. 2006 to Nov. 2006 in Yong-dong Sevrance hospital. 5 of them went through local anesthesia and 3 of them went through general anesthesia. In order to control laser fiber, flexible digital transnasal laryngoscope was applied under local anesthesia and general anesthesia using LMA, and micromanipulator was used under general anesthesia using endotracheal tube. The evaluations of vocal function was done at pre-and postoperation. Results: All patients improved in the perceptual evaluation of voice after PDL surgery. The aerodynamic study revealed that 5 of 8 patients showed improvement in maximal phonation time, and 6 of 8 showed improvement in mean airflow rate during phonation. The acoustic analysis revealed that all patients showed improvement in Jitter and Shimmer, and 7 of 8 showed improvement in noise to harmony ratio. Conclusion: This study demonstrates promising results in the efficacy of 585-nm PDL for the treatment of vocal polyps, and it illustrates a new option for vocal polyp treatment as well as the advantage of PDL surgery.

  • PDF

Voice Analysis before and after Radioactive Iodine Ablation in Patients with Total Thyroidectomy (적갑상선 전절제술 환자의 방사성 동위원소치료 전.후 음성의 변화에 대한 연구)

  • Hong, Ki Hwan;Seo, Eun Ji;Lee, Hyun Doo;Yoon, Yun Sub;Lim, Seok Tae
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2013
  • Background and Objectives:This study is to objectively compare and analyze the acoustic changes in the patients with total thyroidectomy before and after RI therapy. Subjects and Methods:For this study, a total of 50 patients with total thyroidectomy were participated as subjects. Voice samples were obtained at the time of post-operation (Post-OP), before high-dose radioactive iodine therapy (Pre-RIT), and after high-dose radioactive iodine therapy (Post-RIT). Acoustic analysis, the maximum phonation time and K-VHI (Korea-Voice handicap index) were used for subjective evaluation. Results:According to the comparison analysis of the three periods, mFo (Hz) was significantly reduced in all of the vowels /a/ and /i/ as the hormone was discontinued. This can be related to the reduction in vocal range. As thyroid hormone was discontinued, Shim (%) and APQ (%) values, which are the parameters related to the degree of aggressiveness, showed a significant increase in the middle vowel /a/. As thyroid hormone was discontinued, emotional index was significantly decreased in VHI (voice handicap index). Conclusion:These results can be assumed that thyroid hormone suspension is related to the increased changes in the vocal intensity, the increase in noise and the reduction in vocal range. Emotionally, these data can be assumed that the responsive factors of one's own voice disorders were significantly decreased in the patients with vocal handicap.

  • PDF

Pixel-level Current Mirroring Injection with 2-step Bias-current Suppression for 2-D Microbolometer FPAs (이차원 마이크로볼로미터 FPA를 위한 이 단계 바이어스 전류 억제 방식을 갖는 픽셀 단위의 전류 미러 신호취득 회로)

  • Hwang, Chi Ho;Woo, Doo Hyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.36-43
    • /
    • 2015
  • A pixel-level readout circuit is studied for 2-dimensional microbolometer focal plane arrays (FPAs). A current mirroring injection (CMI) input circuit with 2-step current-mode bias suppression is proposed for a pixel-level architecture with high responsivity and long integration time. The proposed circuit has been designed using a $0.35-{\mu}m$ 2-poly 4-metal CMOS process for a $320{\times}240$ microbolometer array with a pixel size of $50{\mu}m{\times}50{\mu}m$. The proposed 2-step bias-current suppression has sufficiently low calibration error with wide calibration range, and the calibration range and error can be easily optimized by controlling some design parameters. Due to high responsivity and a long integration time of more than 1 ms, the noise equivalent temperature difference (NETD) of the proposed circuit can be improved to 26 mK, which is much better than that of the conventional circuits, 67 mK.