• Title/Summary/Keyword: background leakage

Search Result 156, Processing Time 0.028 seconds

Study on Improving Hyperspectral Target Detection by Target Signal Exclusion in Matched Filtering (초분광 영상의 표적신호 분리에 의한 Matched Filter의 표적물질 탐지 성능 향상 연구)

  • Kim, Kwang-Eun
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.5
    • /
    • pp.433-440
    • /
    • 2015
  • In stochastic hyperspectral target detection algorithms, the target signal components may be included in the background characterization if targets are not rare in the image, causing target leakage. In this paper, the effect of target leakage is analysed and an improved hyperspectral target detection method is proposed by excluding the pixels which have similar reflectance spectrum with the target in the process of background characterization. Experimental results using the AISA airborne hyperspectral data and simulated data with artificial targets show that the proposed method can dramatically improve the target detection performance of matched filter and adaptive cosine estimator. More studies on the various metrics for measuring spectral similarity and adaptive method to decide the appropriate amount of exclusion are expected to increase the performance and usability of this method.

The correlation of the halo mura and off-axis light leakage level in LCDs with 2D dimmable LED backlight system

  • Kwon, Jang-Un;Byun, Min-Chul;Ham, Jung-Hyun;Baek, Heume-Il;Moon, Hong-Man;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.590-593
    • /
    • 2009
  • In the 2D local dimmable LED backlight system, each LED segment can be controlled separately. This can enhance the contrast ratio and reduce overall power consumption of LCDs. However, an artifact such as 'halo mura' can be observed around the bright object in the dark background. This is caused by the light leakage from the bright area into the dark one. Therefore, the 'halo mura' can be more easily observed in the oblique viewing direction. Thus, in this study, the perceivable degree of the halo mura is evaluated according to the level of the off-axis light leakage of LCDs. It is found that an acceptable degree of halo mura can be obtained in 2.0 cd/$m^2$ of the diagonal light leakage. In addition, the halo mura is unperceivable under 0.7 cd/$m^2$ of the diagonal light leakage which can be achieved with optimally compensated polarizers.

  • PDF

Feasibility Study of Beta Detector for Small Leak Detection inside the Reactor Containment

  • Jang, JaeYeong;Schaarschmidt, Thomas;Kim, Yong Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.154-159
    • /
    • 2018
  • Background: To prevent small leakage accidents, a real-time and direct detection system for small leaks with a detection limit below that of existing systems, e.g. $0.5gpm{\cdot}hr^{-1}$, is required. In this study, a small-size beta detector, which can be installed inside the reactor containment (CT) building and detect small leaks directly, was suggested and its feasibility was evaluated using MCNPX simulation. Materials and Methods: A target nuclide was selected through analysis of radiation from radionuclides in the reactor coolant system (RCS) and the spectrum was obtained via a silicon detector simulated in MCNPX. A window was designed to reduce the background signal caused by other nuclides. The sensitivity of the detector was also estimated, and its shielding designed for installation inside the reactor CT. Results and Discussion: The beta and gamma spectrum of the silicon detector showed a negligible gamma signal but it also contained an undesired peak at 0.22 MeV due to other nuclides, not the $^{16}N$ target nuclide. Window to remove the peak was derived as 0.4 mm for beryllium. The sensitivity of silicon beta detector with a beryllium window of 1.7 mm thickness was derived as $5.172{\times}10^{-6}{\mu}Ci{\cdot}cc^{-1}$. In addition, the specification of the shielding was evaluated through simulations, and the results showed that the integrity of the silicon detector can be maintained with lead shielding of 3 cm (<15 kg). This is a very small amount compared to the specifications of the lead shielding (600 kg) required for installation of $^{16}N$ gamma detector in inside reactor CT, it was determined that beta detector would have a distinct advantage in terms of miniaturization. Conclusion: The feasibility of the beta detector was evaluated for installation inside the reactor CT to detect small leaks below $0.5gpm{\cdot}hr^{-1}$. In future, the design will be optimized on specific data.

Feasibility study of β-ray detection system for small leakage from reactor coolant system

  • Jang, Jaeyeong;Jeong, Jae Young;Park, Junesic;Cho, Young-Sik;Pak, Kihong;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2748-2754
    • /
    • 2022
  • Because existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm·hr-1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.

A Study on the Explosive Plugging of A Repair for Defective Tube/Tubeplate on the Nuclear Steam Generator (원자력 증기발생기 결함 세관 보수용 폭발 Plugging에 관한 연구)

  • 이병일;심상한;강정윤;이상래
    • Explosives and Blasting
    • /
    • v.17 no.4
    • /
    • pp.18-31
    • /
    • 1999
  • The explosive forming has been used for many year to expand tubes into tubesheets. this process has demonstrated ability to direct carefully the energy of an explosive to expand tubes into tubesheet holes without damaging the tubesheet and without causing the excessive cold work at the tube I.D. that is normally associated with mechanical expansion. The success of explosive tube expansion provided the background for the development of the explosive tube plug. The main results are as follows : (1) The optimum explosives and explosive qualities are PETN, RDX, HMS and about 18~31gr/ft of explosive plugging in nuclear steam generator. (2) Explosive plugging's thickness is 0.9~1.8mm. If groove of 0.4 mm formed in plug outside, For the hydraulic leakage is go up, explosive plugging of formed groove are applicate tube and tubrplate. (3) Sheath is designed on the polyethylene of low density, In thermal impact test of the $430^\circ{C}$, hydraulic leakage is $300kg/cm^2$. (4) About 10~60mm oxide inclusions are existed on the space of explosive plug and tube protect to the leakage.

  • PDF

Influence of the Thin-Film Ag Electrode Deposition Thickness on the Current Characteristics of a CVD Diamond Radiation Detector

  • Ban, Chae-Min;Lee, Chul-Yong;Jun, Byung-Hyuk
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.131-136
    • /
    • 2018
  • Background: We investigated the current characteristics of a thin-film Ag electrode on a chemical vapor deposition (CVD) diamond. The CVD diamond is widely recognized as a radiation detection material because of its high tolerance against high radiation, stable response to various dose rates, and good sensitivity. Additionally, thin-film Ag has been widely used as an electrode with high electrical conductivity. Materials and Methods: Considering these properties, the thin-film Ag electrode was deposited onto CVD diamonds with varied deposition thicknesses (${\fallingdotseq}50/98/152/257nm$); subsequently, the surface thickness, surface roughness, leakage current, and photo-current were characterized. Results and Discussion: The leakage current was found to be very low, and the photo-current output signal was observed as stable for a deposited film thickness of 98 nm; at this thickness, a uniform and constant surface roughness of the deposited thin-film Ag electrode were obtained. Conclusion: We found that a CVD diamond radiation detector with a thin-film Ag electrode deposition thickness close to 100 nm exhibited minimal leakage current and yielded a highly stable output signal.

Comparison of Had-Sewn and Mechanical Esophagogastric Anastomosis After Esophageal Resection for Cancer (식도암수술시 식도-위연결부 수기봉합과 기계봉합의 비교)

  • Shin, Jae-Seung;Choi, Young-Ho;Kim, Kwang-Taik;Hwang, Jae-Joon
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.2
    • /
    • pp.143-152
    • /
    • 1999
  • Background : the technical modality of esophagogastric anastomosis plays an important part in the factors leading to anastomotic leakage and stricture. Objective : The objective of this study was to compare the leakage and stricture rates between the different anastomosis techniques. Materials and Methods : A retrospective study was undertaken in the patients with esophageal cancer who underwent a esophagectomy. Hand-sewn anastomosis was performed in one layer with interrupted sutures(Manual group). The stapler group was divided into two subgroups, such as PCEEA group and Endo-GIA group. Results : The differences of preoperative patient profiles between the groups were not significant. Overall mortality fates were 5% in manual group, 5% in PCEEA group and 11.5% in Endo-GIA group. Fewer anastomotic leakage occurred in manual group(5%) than in PCEEA group(10%) or in Endo-GIA group(15.4%). The postoperative stricture rate was higher in PCEEA group(35%) than in manual group(5%) or in Endo-GIA group(0%) Conclusion : Statistically, there were no significant differences in the anastomotic leakage and stricture rates between the hand-sewn and mechanical anastomosis. But the stricture rate was lower in the group using the linear stapling device and the leakage rate was lower in the hand-sewn group than the other groups.

  • PDF

Analysis of impact of CATV leakage on CDMA Mobile Communication Systems (CDMA 이동통신시스템에 대한 케이블 방송 전송설비 누설전자파 영향 분석)

  • Park, Seong-Gyoon;Han, Chan-Kyu
    • Journal of IKEEE
    • /
    • v.15 no.3
    • /
    • pp.218-226
    • /
    • 2011
  • In this paper, the leaky electric field intensity of outdoor CATV facilities on CDMA mobile service band defined in technical regulation related with CATV is investigated if appropriate or not. From experimental and theoretical analysis results, Maximum allowable power level of CATV leakage should be -110dBm/1.23MHz. Also, the CATV leakage intensity thresholds, which may not nearly give an impact on the uplink performance of CDMA mobile base station for outdoor background noise of -100~-80dBm/1.23MHz to be measured in outdoor environment, couldn't conform to the current CATV technical regulation. Therefore, the leakage intensity in the current CATV technical regulation is rated as a too much low level in view of an overly worst case.

Ultra shallow $p^{+}$n junction formation using the boron diffusin form epi-co silicide (에피 코발트 실리사이드막으로 부터의 붕소 확산을 이용한 극저층 $p^{+}$n 접합 형성)

  • 변성자;권상직;김기범;백홍구
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.134-142
    • /
    • 1996
  • The epi-CoSi$_{2}$ layer was formed by alloying a Co(120$\AA$)/Ti(50$\AA$) bilayer. In addition, the ultra shallow p$^{+}$n junction of which depth is about not more than 40nm at the background concentration, 10$^{18}$atoms/cm$^{3}$ could be formed by annealing (RTA-II) the ion implanted epi-silicide. When the temperature of RTA-I is as low as possible and that of RTA-II is moderate, the p$^{+}$n junction that has low leakage current and stable epi-silicide layer could be obtained. That is, when th econdition of TRA-I was 900$^{\circ}C$/20sec and that of RTA-II was 900$^{\circ}C$/10sec, the reverse leakage current was as high as 11.3$\mu$A/cm$^{2}$ at -5V. The surface of CoSi$_{2}$ appeared considerably rough. However, when the conditon of RTA-I was 800$^{\circ}C$/20sec or 700$^{\circ}C$/20sec, the leakage currents were as low as 8.3nA/cm$^{2}$ and 9.3nA/cm$^{2}$, respectively and also the surfaces appeared very uniform.

  • PDF

The Abdominal Approach for Epiphrenic Esophageal Diverticulum as an Alternative to the Thoracic Approach

  • Kim, Shin;Cho, Jong Ho
    • Journal of Chest Surgery
    • /
    • v.52 no.4
    • /
    • pp.227-231
    • /
    • 2019
  • Background: There is no established surgical procedure for the treatment of epiphrenic esophageal diverticulum. The aim of this study was to compare the clinical outcomes of esophageal diverticulectomy using abdominal and thoracic approaches. Methods: We retrospectively reviewed 30 patients who underwent esophageal diverticulectomy through the thoracic or abdominal approach for an epiphrenic diverticulum at a single center between 1996 and 2018. We compared clinical outcomes, including the postoperative length of stay, time from the operation to oral feeding, leakage rate, and reoperation rate between the 2 groups. Results: The median age was 56 years. Of the 30 patients, 18 (60%) underwent diverticulectomy via the thoracic approach and 12 (40%) underwent the abdominal approach. The median hospital stay was 10 days (range, 5-211 days) in the thoracic approach group and 9.5 days (range, 5-18 days) in the abdominal approach group. The median time from the operation until oral feeding was 6.5 days (range, 3-299 days) when the thoracic approach was used and 5 days (range, 1-11 days) when the abdominal approach was used. In the thoracic approach group, the leakage rate was 16.67% and the reoperation rate was 27.78%. However, there were no cases of leakage or reoperation in the abdominal approach group. Conclusion: The abdominal approach for esophageal diverticulectomy is a feasible and appropriate alternative to the thoracic approach.