• Title/Summary/Keyword: back-to-back sections

Search Result 115, Processing Time 0.028 seconds

An Assessment on the Urban Riverfront in Shincheon, Daegu - Focused on a Universal Design Concept - (대구광역시 신천의 친수공간 평가 연구 - 유니버설디자인 개념을 중심으로 -)

  • Choi, Dong-Sik;Moon, Ji-Won;Kim, Shang-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.2
    • /
    • pp.1-14
    • /
    • 2012
  • The purpose of this study is to derive a desirable riverfront construction plan to me for the activities of citizens through the evaluation and analysis of the urban riverfront space from the perspective of universal design. Therefore, previous studies were examined in order to induce evaluation tools that bhve been grafted from the universal design concept; in addition, a field survey was conducted in Shincheon, Daegu, which was selected as the study target, in order to induce problems and improvement directions from the perspective of universal design. The major results can be summarized as follows. (1) In the 'fairness' aspect, all the items such as installation of integrated functional signage, showing pictures, symbols, foreign language signs, and restroom entrances signage were determined to be 'All Unsuitable' for all sections; and therefore, it is necessary to improve the fairness of usage for everybody. (2) In the 'Functionality(Usability)' aspect, all items such as installation of bicycle paths beside access roads, installation of integrated functional signs, and night light signs were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the functionalities of these facilities. (3) In the 'Convenience' aspect, all items such as the installation of bicycle parking areas, continuous rest facilities, and back and ann support(handles) at resting facilities were determined to be 'All Unsuitable' for many sections; therefore, it is necessary to improve these facilities for the convenience of usage. (4) In the 'Information(Recognizability)' aspect, all items such as showing pictures, symbols, foreign languages and installation of night light signs, and restroom entrances signage were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the recognizability to minimize misunderstandings and confusion. (5) In the 'Safety' aspect, all items such as the installation of safe pedestrian paths in parking areas, using anti-slip and shock absorption materials on restroom floors, and the continuous installation of pedestrian paths that are separate from bicycle paths were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the safety to prevent accidents. (6) In the 'Amenity' aspect, access roads, parking areas, hygiene facilities, convenience facilities, and waterside facilities for many sections were determined to be 'All Unsuitable'; therefore, it is necessary to conduct more concentrated hygiene management. (7) In the 'Accessibility(Mobility)' aspect, all items such as the installation of safe pedestrian paths in parking areas, and continuous pedestrian paths that are separate from bicycle paths were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the accessibility to provide safety and convenience. (8) In the 'Durability' aspect, access roads, parking areas, rest facilities, convenience facilities, fitness facilities, and waterside facilities were determined to be 'All Unsuitable' for many sections, therefore, it is necessary to improve sunken or damaged areas by inspecting facilities by section.

3D Body Scan Data Analysis for the Slim-fit Dress Shirts Pattern Design -Focused on the 40s Male- (슬림 핏(Slim-fit) 드레스 셔츠 패턴 설계를 위한 3D Body Scan Data 활용에 관한 연구 -40대 남성을 중심으로-)

  • Shin, Kyounghee;Suh, Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.1
    • /
    • pp.97-109
    • /
    • 2014
  • This study developed a functional dress shirt for adult males that reflected the body surface variation of a human body section by motion. This study conducted a 3D body scan for 8 subjects in their 40's based on the Size Korea 2010 database. Data recorded the proper posture change value and body surface change value to develop functional dress shirts for adult males. We scanned the subjects with a 3D body scanner for five primarily male wearing dress shirts and operating postures, right standing, arms raised to $90^{\circ}$ horizontal forward position, arms raised $90^{\circ}$ to the horizontal position side, lift up the arm $180^{\circ}$, and arm forward $90^{\circ}$ in a bent posture. We analyzed the 3D scan data from those motions to examine change of length using 3D software Rapidform XOS. The results indicated that the body surface sections with contraction were the front and rear shoulder area, armpit and central length as well the width of arms at more than 10%. The increased body section included the body and armpit back length; in addition, the rear arm vibration girth and under arm girth were more than 10%. In order to reflect the size variation of for each motion, the ease amount of the front and rear shoulder length and width needs to be reduced 20% because it affects the shoulder length during the right standing. The results suggest that the ease amount of the shoulder length should be minimal. The ease amount of the back size needs to be 0.5-2cm bigger and set 0.5-1.5cm longer than the dress shirt length side drooping to compensate for the side length shortage of each motion. The sleeve length needs to be 0-0.5cm shorter, and ease amount of the girth of sleeve bottom needs to be reduced 0-0.7cm due to the size variation of arms. However, the girth of the rear arms is suggested to be 0-0.6cm longer in the ease amount to the rear arm girth as the extension is more than 10% over the width and length of each motion.

Comparative Research of Decalcification Methods for Quick Diagnosis on Bone Tissue (골조직의 신속한 진단을 위한 탈회방법의 비교 연구)

  • Kim, Sung-Chul;Back, Oun-Chul;Kim, Tai-Jeon;Bae, Hyung-Joon;Kang, Hee-Gyoo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.47-55
    • /
    • 2005
  • These studies were done to know decalcification methods to reduce the time of decalcification for quick bone tissue diagnosis. When bone tissue was decalcified with 10 % formic acid at room temperature, decalcification and hematoxylin & eosin (H&E) stains were complete and satisfactory after 12 hours, but some of the tissue sections fell off during staining. In this way, decalcification, H&E stains were complete and satisfactory after 24 hours, 36 hours and 48 hours, tissue sections didn't fall off during staining. When bone tissue was decalcified with 10 % formic acid in a $60^{\circ}C$ paraffin oven, decalcification and H&E stains were complete and satisfactory after 6 hours, but some tissue sections fell off during staining. In this way, decalcification and tissue sections were complete, with no falling off during staining after 8 hours, 10 hours, 12 hours, 14 hours, 24 hours, or H&E stains were satisfactory from 8 hours to 12 hours, but H&E stains appeared to reddish nucleus after 14 hours and 24 hours. Bone tissue was decalcified with 10 % formic acid for 6 hours, 12 hours and 24 hours at DECAL machine frequencies of 15 Hz and 45 Hz, and for 6 hours, 12 hours and 24 hours at a DECAL machine frequency of 90 Hz. Decalcification and H&E stains were complete and satisfactory after 6 hours at the 15 Hz and 45 Hz DECAL settings. Some of the tissue sections fell off during staining at the 15 Hz DECAL machine setting. At the 90 Hz setting, decalcification, H&E stains, and tissue sections were complete and satisfactory with no falling off during staining after 4 hours. In this way, decalcification, H&E stains, and tissue section were complete and satisfactory with no falling off during staining after 12 hours, 24 hours at all machine settings. Bone tissue was decalcified with 10 % formic acid for 6 hours, 12 hours and 24 hours at $37^{\circ}C$ 3 hours, 6 hours and 12 hours at $45^{\circ}C$ and 1 hours, 5 hours and 10 hours at $60^{\circ}C$ with the RHS-1 machine setting at 60Hz. At the temperatures of $37^{\circ}C$, $45^{\circ}C$, and $60^{\circ}C$ decalcification, H&E stains, and tissue sections were complete and satisfactory, with no falling off during staining except for after 6 hours at $37^{\circ}C$. 3 hours, 1 hours, or decalcification, H&E stains, and tissue sections were complete and satisfactory with no falling off during staining after 12 hours and 24 hours at $37^{\circ}C$, 6 hours and 12 hours at $45^{\circ}C$, and 5 hours at $60^{\circ}C$. But H&E stains appeared to reddish nucleus after 10 hours at $60^{\circ}C$. From the above reults, the authors were able to deduce that decalcification is accelerated by heat and frequency. We therefore think that it is necessary for machines which are similar to the RHS-1 machine to be maintained at the temperature evenly with agitation effect for quick decalcification.

  • PDF

Alteration Textures and Mineral Chemistry of Margarite from Miwon Area, Chungcheongbukdo (충북미원지역에서 산출하는 마카라이트의 변질양상 및 광물화학)

  • 이승준;안중호;김현철;조문섭
    • Journal of the Mineralogical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.69-77
    • /
    • 2002
  • Margarite, which occurs in the Unkyori Formation of Miwon area, Chungcheongbukdo, South Korea, was investigated using the petrographic microscope, back-scattered electron images (BSEI), and electron probe microanalyzer (EPMA) to characterize the alteration textures and mineral chemistries. Most margarite crystals are inhomogeneous, and chlorite was commonly observed to occur at the boundaries parallel to the rim of margarite. Cracks occur across the basal plane of the margarite, and margarite is partly replaced by chlorite along the cracks. In additon, muscovite and biotite are intergrown in margarite and chlorite crystals, suggesting that margarite was partially altered to chlorite as well as to muscovite and biotite. Chemical analysis data show that paragonite solid solution in the margarite is approximately 19.6 mol%, but clintonite solid solution is negligible. Margarite crystals in the Unkyori Formation cut or penetrate other metamorphic minerals In the same thin sections and are oriented randomly without any relationship with the foliation of host rocks, indicating that formed as a secondary mineral after peak metamorphism. Furthermore, it seems that hydrothermal fluids associated with the Mesozoic intrusions developed near the sample are closely related to the margarite formation.

A Study on Millimeter Wave Power Amplifiers Using Spatial Combining (공간 결합을 이용한 밀리미터파 전력 증폭기에 관한 연구)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.4
    • /
    • pp.77-82
    • /
    • 2017
  • As frequencies increase to the millimeter wave bands the cross sections of wave guides become smaller than a few millimeters, which cause sapatial problems in realization of spatial combining power amplifiers. In this paper we intented to overcome the problem by widening the width of wave guides using horn antenna principles. We designed a widened rectangular wave guide for using in spatial combining power amplifier in 60GHz ISM band(57-64GHz), and we installed Antipodal transition in the widened wave guide, and then we characterized it as a spatial combining power amplifier. For the compatibility of WR15 standard wave guide, we widened the width of WR15 to 7mm using principle of H-plane sectoral horn antenna and then installed 3 slots of back to back Antipodal transition. The designed spatial combining power amplifier showed good characteristics of return loss less than -22.4dB and insertion loss less than 0.53dB. However, as widening the width of the wave guide, additional modes such as $TE_{20}$, $TE_{30}$ in addition to $TE_{10}$ were accurred in the bandwidth of WR15, which restricted the bandwidth and widening of the width of the wave guide.

Flexural and Buckling Analysis of Laminated Composite Beams with Bi- and Mono-Symmetric Cross-Sections (이축 및 일축 대칭단면 적층복합 보의 휨과 좌굴해석)

  • Hwoang, Jin-Woo;Back, Sung Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.614-621
    • /
    • 2019
  • A generalized laminated composite beam element is presented for the flexural and buckling analysis of laminated composite beams with double and single symmetric cross-sections. Based on shear-deformable beam theory, the present beam model accounts for transverse shear and warping deformations, as well as all coupling terms caused by material anisotropy. The plane stress and plane strain assumptions were used along with the cross-sectional stiffness coefficients obtained from the analytical technique for different cross-sections. Two types of one-dimensional beam elements with seven degrees-of-freedom per node, including warping deformation, i.e., three-node and four-node elements, are proposed to predict the flexural behavior of symmetric or anti-symmetric laminated beams. To alleviate the shear-locking problem, a reduced integration scheme was employed in this study. The buckling load of laminated composite beams under axial compression was then calculated using the derived geometric block stiffness. To demonstrate the accuracy and efficiency of the proposed beam elements, the results based on three-node beam element were compared with those of other researchers and ABAQUS finite elements. The effects of coupling and shear deformation, support conditions, load forms, span-to-height ratio, lamination architecture on the flexural response, and buckling load of composite beams were investigated. The convergence of two different beam elements was also performed.

Effects of Electrical Stimulation on the Mast Cell of Skin in Rats (전기자극이 흰쥐의 피부 비만세포에 미치는 영향)

  • Lee Jae-Hyoung;Jekal Seung-Joo;Park Seung-Teack
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.3
    • /
    • pp.81-87
    • /
    • 1999
  • The purpose of this study was to determine the effect of electrical stimulation on the number of MCs and percent of degranulated MCs in rat skin. Twelve male Sprague-Dawley rats were divided into two group; electrical stimulation group (n=6) and control group (n=6). Each animals hair on the back was removed. The electrical stimulation group received an positive rectangular pulsed electrical stimulation, while the control group was given the same treatment without electricity. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with toluidine blue-nuclear fast red and alcian blue-safranin O. respectively. The MCs were counted using a light microscope and computerized image analysis system and calculated as the density and the percent. A t-test showed a significantly higher density of MCs in the electrical stimulated rats than control rats(p<0.05), and the percent of degranulated MCs in the electrical stimulated rats was higher than in the control rats (p<0.05) in toluidine blue stained sections. The density of MCs was significantly higher in the electrical stimulated rats than the control rats in alcian blue-safranin O Stained sections (P<0.01). An analysis of variance showed that the densities of CTMCs was significantly lower than the densities of MMCs and mixed MCs in electrical stimulated rat in alcian blue-safranin O Stained sections (p<0.05). These results suggest that the electrical stimulation may have potential for increasing the number of MCs and lead to degranulate the MCs in rat skin.

  • PDF

Analysis on Differences in Muscle Activities Depending on Distance Changes and Success or Failure in Connection with Golf Approach Swings (골프 어프로치 스윙 시 거리변화와 성공·실패에 따른 EMG 차이 분석)

  • Lee, Kyung-Ill;You, Moon-Seok;Hong, Wan-Ki
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • Objectives : The purpose of this study was to compare differences in muscle activities according to distance changes, and success or failure in relation to approaches during a round of golf in order to obtain basic data on golf swings. Methods : To achieve our research goal, we asked eight professional golfers playing for the Korea Professional Golfers' Association (height: $1.76{\pm}0.05m$, weight: $73.87{\pm}9.21kg$, career duration: $12.87{\pm}4.48yr$) to perform approach swings at distances of 30, 50, and 70 m. Results : No differences were observed in the muscle activity of the extensor carpi radialis that were caused by the distance changes. In addition, we found that the wrist extensors seemed unaffected by the increase in approach distance. Also, we found that the powers of the approach shots were driven by efficient movements rather than by the strength of the arms. We confirmed that when the distance of the approach increased, the golfers should perform their back-swing tops and follow-through right from the right to the left pelvic limb. To achieve successful approach swings despite distance changes, golfers should first work on the activity of the erector spinae to prepare for rotatory power in the P1 section. Moreover, golfers should increase the activity of the erector spinae on the left when they need to deal with the distance improvements in the P2 and P3 sections. Conclusion : In the light of the discussion above, we may infer that despite approach distance changes during a round of golf, ideal swings can be realized by consistent activities of the wrist extensor muscles and improved performances of the pelvic limb muscles. Furthermore, this study suggests that golfers should improve the consistency of muscle activities in all the other body parts to achieve the ideal swing.

A Study on Boesun -On the Comparison of the Basic Patterns of Boesun- (한복 버선에 관한 연구 -버선 원형의 비교를 중심으로-)

  • Moon Meyng Ok;Kim Ya Ji
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.9 no.2
    • /
    • pp.45-55
    • /
    • 1985
  • The main purpose of this study is to investigate the suitability of Boesun (the Korean Socks) to the foot. In order to find the problem of Boesun, I made up the questionnaire. The suitabltity of Boesun to the foot was experimented by 'the replica method', 'the fuse method' and 'the deform painting method'. The pressure of Boesun to the foot was measured by utilizing a human sensitivity as a sensor. The results were as follows. 1. In the questionnaire, the fore part of Boesum was uncomfortable by the pressure. 2. The surface area of Boesun was generally smaller than the surface area of the foot, but the ratio of two surface area related closely to the individual. 3. At the cross-sections from No. 1 to No. 10, the breadth of the worn Boesun was smaller than the breadth of the foot. Because of the smaller breadth of the worn Boesun, the foot was get the pressure at the fore part of Boesun. This result accorded with the result of the questionnaire. 4. The location of the deformation by 'deform painting method' was almost the fore part of Boesun. 5. The pressure of Kwon's Boesun was 2.57$\~$2.99kg, the pressure of Kim's Boesun was 1.31$\~$1.74 kg and the pressure of Lee's Boesun was 3.42$\~$3.88kg. Compared with the distribution chart of the pressure, Kwon's Boesun was involved the back part of 'slightly pressured' and the fore part of 'pressured', Kim's Boesun was involved the fore part of 'slightly pressured' and Lee's Boesun was involved the middle part of 'pressured'.

  • PDF

The Foot Pressure Change Caused by Functional Leg Length Having an Effect on the Foot Temperature (기능적인 하지길이 차이에 따른 족저압 변화가 족부체열에 미치는 영향)

  • Kim, Minju;Kim, Juyeon;Lee, Hyewon;Yim, Juyeon;Ha, Hyunjin;An, Jinho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.1 no.2
    • /
    • pp.37-46
    • /
    • 2013
  • Purpose : The purpose of the research was to analyze foot pressure, foot temperature, and correlation between foot pressure and foot temperature to grasp impact on foot pressure and body temperature distribution chart depending on functional difference of leg length. Method : After measuring leg length, put 15 students whose functional difference of leg length was over 10mm to difference group and 15 students whose functional difference of leg length was under 5mm to normal group and categorize soles of foot into 6 sections of hallux head, 1st metatarsal head, 2-4 metatarsal head, 5 metatarsal head, lateral heel, and then measure by foot pressure analyzer to analyze characteristic of pressure distribution and classify into front of the lower leg, back of the lower leg, soles of foot and measure by body temperature analyzer to analyze by checking body temperature. Result : Weight difference depending on foot pressure and body temperature was bigger when functional difference of leg length was bigger, and it could be confirmed that foot pressure and body temperature of short leg side were higher than those of short leg side. Thus, if difference exists in leg length, weight load on short leg side increases which results in higher foot pressure and body temperature, therefore enabling an assumption that mechanical problem will occur in short leg. Conclusion : When functional leg length inequality, weight bearing and pressure was getting high as a result, temperature was getting high in short leg.