• Title/Summary/Keyword: back-off

Search Result 471, Processing Time 0.026 seconds

Compensation of Nonlinear Distortion Using a Predistorter Based on Real-Valued Fixed Point Iterations in MC-CDMA Systems (MC-CDMA 시스템에서 실수 고정점 반복 기반의 전치왜곡기를 이용한 비선형 왜곡 보상)

  • Jeon, Jae-Hyun;Shin, Yoan-Shin;Im, Sung-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • We propose a predistorter to compensate for nolinear distortion induced by a high power amplifier employed in multi carrier-code division multiple access (MC-CDMA) systems. The proposed scheme rests upon the fixed point iteration (FPI) associated with the contraction mapping theorem. Unlike the predistorter based on the FPI already presented by the authors in other literatures which operates on complex-valued modulation signals, the proposed predistorter in this paper deals with real-valued FPI on modulation signal amplitudes, resulting in less complexity. Simulation results on a BPSK-modulated, 64-subcarrier synchronous MC-CDMA baseband system with a traveling wave tube amplifier in the transmitter, indicate that the proposed predistorter achieves significant improvement in terms of bit error rate and total degradation over those without the predistorter. Moreover, the proposed predistorter outperforms the complex-valued counterpart, in particular, for small output back-off levels.

  • PDF

High Power and High Efficiency Unbalanced Doherty Amplifier used to Extend the Output Power Back-off (출력전력 백-오프 구간을 확장시킨 고출력 고효율 불균형 도허티 전력증폭기)

  • Jang, Dong-Hee;Kim, Ji-Yeon;Kim, Jong-Heon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.5
    • /
    • pp.99-104
    • /
    • 2011
  • This paper presents a high power and high efficiency unbalanced Doherty power amplifier used to extend the output power back-off (OPBO). The proposed unbalanced amplifier uses the same type of transistors in both the main amplifier and the peaking amplifier, similar to a conventional symmetric Doherty amplifier. The unbalanced amplifier can have the impedance of a ${\lambda}/4$ transformer located at the output of the main amplifier modified. This enables the OPBO to exceed 6 dB, the maximum OPBO for a conventional symmetric Doherty amplifier. The efficiency and linearity performance of the unbalanced Doherty amplifier are almost same as those found for the asymmetric Doherty amplifier, even though the unbalanced Doherty amplifier structure is simpler than the asymmetric Doherty structure. In order to verify the proposed amplifier performance, a 46 W Doherty amplifier has been both simulated and measured using a CDMA2000 1FA signal. From the measured results, the proposed unbalanced Doherty amplifier achieved an added power efficiency of 38 % and an adjacent channel power ratio of -34 dBc at a 885 kHz offset frequency and -35.6 dBc at a 1.98 MHz offset frequency.

Performance Analysis of Nonlinear Satellite Communication System in the CCI And ACI Interference Channel (간섭채널에서 비선형 위성 통신 시스템의 특성 분석)

  • 박주석;유흥균;김기근;이대일;김도선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2A
    • /
    • pp.166-173
    • /
    • 2004
  • Satellite communication system uses a high non-linear HPA(high power amplifiers) in the earth station and satellite transponder. Therefore, it is important to consider the nonlinear effect of HPA on the communication system. In this paper, we find the variation of power spectrum density by nonlinearity HPA and the change of harmonic component according to IBO (input back-off). When the BPSK is used for satellite communication system, we analyze BER performance including the external co-channel interference (CCI) and the adjacent channel interference (ACI) resulting from the HPA nonlinearity. BER degrades as ACI magnitude grows up when the uplink SNR, uplink SIR (signal to co-channel interference power ratio) and downlink SIR are constant at some level. In case there is only non-linear HPA in the satellite, it is shown that BER considerably depends on the ACI magnitude ACI. When there are two non-linear HPAs in the both earth station and satellite, much BER degradation results from the CCI and ACI.

Compensation of RF Impairment and Performance Improvement of Digital on Channel Repeater in the T-DMB (T-DMB 동일 채널 중계기의 RF 불균형 보상 및 성능 개선)

  • Kim, Gi-Young;Ryu, Sang-Burm;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.4
    • /
    • pp.453-461
    • /
    • 2011
  • In order to use more efficiently limited frequency resources at the broadcasting band and to eliminate blanket area of the terrestrial broadcasting and to improve broadcasting quality. The importance of repeaters has increasing continuously. However, in case of T-DMB digital on channel repeater in OFDM systems, some of the signal radiated feedback again at the receiver antenna. So it generates feedback signal interference in repeater system. Also phase noise increases ICI(Inter Carrier Interference). It affects seriously the frequency domain equalizer. In this paper, we remove the feedback signal interference by LMS with correlation. Also we propose an effective equalizer algorithm that can remove ICI caused by phase noise and the power amplifier's back-off. In this simulation results, this system is satisfied the performance of BER=$10^{-4}$ at less than SNR=14 dB after compensation of phase noise.

Design of an Effecient Local Area Computer Communication Network Controller for Office Automation (Contention Resolution Algorithm Based on CSMA/CD) (사무자동화를 위한 근거리 컴퓨터 통신망 콘트롤러 개발에 관한 연구)

  • 이명수;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.11 no.2
    • /
    • pp.137-145
    • /
    • 1986
  • The contention resolution algorithm with the limited packet delay time as well stable distribution as the packet delay time is proposed and implementes for improving the mean packet delay time in the network employing CSMA/CD as the access method. The implementation of node controller is based on IEEE 802.2 standard logical link control(LLC) and IEEE 802.3 standard medium access control(MAC). Some portion of IEEE 802.3 Standard MAC, and the Binary Exponential Back-off(BEB) algorithm is replaced by the proposed algorithm. From the view of normalized mean packet transmission delay time, the controller implemented here can be applicable to the office-automation system, and the factory-and laboratory-automation environment where the limited time criterion is very significant.

  • PDF

Evaluation of Muscle Load and Fatigue According to the Shape of Severe Dementia Patients' Clothing (중증 치매환자복 형태에 따른 근육 부하 및 피로도 평가)

  • Kwang Ae Park;Chung Eun Yang;Hayoung Jung
    • Fashion & Textile Research Journal
    • /
    • v.25 no.2
    • /
    • pp.185-198
    • /
    • 2023
  • The purpose of this study is to obtain information necessary for the development of patient clothes that can reduce physical fatigue of caregivers by quantitatively measuring the muscle load and fatigue. The patient clothes used in this study can be broken down into three types: A type (back center zipper open suit), B type (top-to bottom separated patient clothes), and C type (front zipper open suit). The EMG measurement sites are as follows: hand muscle (brachioradialis), upper arm (biceps, triceps), shoulder (anterior deltoid, medial deltoid, posterior deltoid, upper trapezius), and waist (erector spinae); additionally, the EMG signals were measured. Through this experiment, muscle load, muscle energy consumption, and muscle fatigue generation tendency were analyzed. The results of the study revealed that the C type patient clothes required the most strength in the muscles of the shoulders, upper arms, hands, and back when being put on and taken off compared to other patient clothes. The A type clothes required a relatively large force in opening the zipper. In terms of muscle energy consumption, B type generally called for more strength when it came to the zip-up and putarmsup motions. With regard to the cover the body and put legs/hips up motions, C type used the highest amount of muscle energy, whereas A type used relatively little energy. In terms of the occurrence of muscle fatigue during the putting on and taking off of the patient's clothing, there was a difference in the area and degree of muscle fatigue in the A, B, and C types, and there was also a tendency for muscle fatigue to occur when performing repetitive movements.

Comparison of quality of 30:2 vs. 2:30 CPR in manikins (심폐소생술 방법 변화에 따른 quality 비교 - 30:2와 2:30 비교분석실험 -)

  • Uhm, Tai-Hwan;Yoou, Soon-Kyu;Choi, Hea-Kyung;Jung, Ji-Yeon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.14 no.3
    • /
    • pp.71-81
    • /
    • 2010
  • Purpose: To minimize an interruption in chest compression, reduce the hands-off time, the American Heart Association has recommended the ratio of chest compression to ventilation ratio to 30:2 from 2005 CPR guideline to 2010 CPR guideline. However, current studies have shown that the hands-off time was > 10 seconds with that method. For this reason, we devised new CPR method that a ventilation to chest compression ratio of 2:30 to reduce pt assessment time and skipped the assessment step of carotid artery pulse would be a more effective way to reduce the hands-off time & the time to set the CPR. According to the more detailed purpose are listed below. 1) We would like to confirm efficiency of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 to reduce the hands-off time & the time to set the CPR. 2) We would like to evaluate possibility of increasing for chest compression accuracy of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 3) We would like to evaluate possibility of increasing for ventilation accuracy of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 Methods: According to 2005 American Heart Association Guidelines, 60 paramedic students(20 students X freshmen, sophomore, junior) performed 5 cycles of 3~ chest compressions : 2 ventilations after A, B, C evaluation with Laerdal Resusci R Anne SkillReporters. After 5 minutes rest, the 60 students performed 5 cycles of 2 ventilations : 30 chest compressions after A, B evaluation with the manikins between 13 and 17 September 2010. The short reports including speed & accuracy of chest compression, respiratory, CPR cycle were gained from the manikins. Hands-off times were measured by assistants. Results: Recently, the importance of high quality CPR was emphasized in order to perform the CPR faster and more accurate. To find out improving the conventional CPR method, we switch the procedure of the compression and the ventilation. By switching the procedure back and forth, we are able to compare the effectiveness of CPR between two type of CPR method which are 2:30 and 30:2 methods. 2:30 is that the breaths is delivered twice, first and perform 30 compressions while 30:2 perform 30 compressions first and give 2 breaths followed by the ABC method. Also, we verify the effectiveness of the hands off time, compression accuracy of the compression through the comparison of the two procedure as mentioned earlier. Consequently research verified that 2:30 is the efficient by providing faster set up delivering more accurate chest compression. Conclusion: 2:30 can minimize a time delay from cardiac standstill until starting the chest compression. In addition, hands-off time which is an interruption in chest compression can be shortened by 2:30 method, which result to effective oxygenation of coronary artery & maintenance of the bloodstream. Once again, performing the 2:30 method provide lessen hands off time and increase the accuracy of the chest compression.

  • PDF

The Influence of Physical Functions on Clothing Behavior of Elderly People (고령자의 신체 기능이 의복 착용 행동에 미치는 영향)

  • Lee, Eun-Suk;Jeong, Su-Jin;Chu, Mi-Seon
    • Fashion & Textile Research Journal
    • /
    • v.14 no.1
    • /
    • pp.136-143
    • /
    • 2012
  • The purpose of this study was to investigate the influence of physical functions of elderly people on their clothing behavior and to provide basic information about manufacturing comfortable apparels for the elderly. A total of 219 people, with ages between 60s and 70s, participated in the survey and in the experiment to correlate their tendency of wearing clothes with the state of their physical functions. About 78.5% of the elderly showed eyesight deterioration in the subjective evaluation. Elders in their 60s raised their arms higher up in overhead reach, and showed shorter distance between middle fingertips in behind back stretch and in back scratch than elders in their 70s. Also, the former stretched farther to the floor in standing trunk flexion, and maintained more steady in one leg stand and in tandem stance than the latter. The narrower the movement range of the upper limb joints was, the more the elderly preferred upper garments with full front opening to those with half or no opening. The more inflexible the upper limbs and waist and the more unbalanced the body was, the more likely the elderly put on pants while sitting on the floor. The time taken to button up the shirt and to put on and take off pants showed a positive correlation with the overhead reach, the behind back stretch, the back scratch and the standing trunk flexion, whereas the former showed a negative correlation with the one leg stand and the tandem stance.

DESIGN OF A HIGH-THROUGHPUT VITERBI DECODER (고속 전송을 위한 비터비 디코더 설계)

  • Kim, Tae-Jin;Lee, Chan-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.2A
    • /
    • pp.20-25
    • /
    • 2005
  • A high performance Viterbi decoder is designed using modified register exchange scheme and block decoding method. The elimination of the trace-back operation reduces the operation cycles to determine the merging state and the amount of memory. The Viterbi decoder has low latency, efficient memory organization, and low hardware complexity compared with other Viterbi decoding methods in block decoding architectures. The elimination of trace-back also reduces the power consumption for finding the merging state and the access to the memory. The proposed decoder can be designed with emphasis on either efficient memory or low latency. Also, it has a scalable structure so that the complexity of the hardware and the throughput are adjusted by changing a few design parameters before synthesis.

Inactivation of Ralstonia Solanacearum Using Aquatic Plasma Process (수중 Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Back, Sang-Eun;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.797-804
    • /
    • 2012
  • A dielectric barrier discharge (DBD) plasma reactor was investigated for the inactivation of Ralstonia Solanacearum which causes bacterial wilt in aquiculture. The DBD plasma reactor of this study was divided into power supply unit, gas supply unit and plasma reactor. The plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the optimum 1st voltage, 2nd voltage, air flow rate and pH were for 100 V (1st voltage), 15 kV (2nd voltage), 4 L/min, and pH 3, respectively. At a low 1st voltage, shoulder and tailing off phenomena was observed. The shoulder phenomenon was decreased as the increase of 1st voltage. R. Solanacearum disinfection in the lower air flow rate was showed shoulder and tailing off phenomenon because the active species generated less. Under optimum condition, shoulder and tailing off phenomenon was reduced. When the 2nd voltage was less than 7.5 kV, tailing off phenomenon was observed and this was not vanishes even though the increase of the disinfection time. The inactivation efficiency increased as the increase of air flow rate, however, the efficiency decreased when the air flow rate was above 4 L/min. R. Solanacearum disinfection at pH 3 showed somewhat higher than in pH 11. The pH effect of R. Solanacearum deactivation is less than the impact on other factor.