• Title/Summary/Keyword: axis body

Search Result 567, Processing Time 0.024 seconds

Evaluation of Setup When Using C-Rad System in Radiotherapy (방사선치료 시 C-Rad system을 이용한 셋업의 평가)

  • Park, Eun-Tae;Ko, Seong-Jin;Choi, Seok-Yoon;Kim, Jung-Hoon;Kim, Chang-Soo;Kim, Dong-Hyun;Kang, Se-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.303-310
    • /
    • 2012
  • In radiotherapy, accurate patient positioning and set up are important factor that treatment can influence success. In generally, the 3-laser system is used when the patient set up. But today the body surface scanning system(C-Rad system) is trying to use. Compare and evaluate the C-Rad system and the 3-laser system to check availability. Head and neck that are no movement of internal organs and easy to apply fixation device are limited. Alderson Rando anthropomorphic phantom and 10 patients who have lesions of head and neck are targeted. C-RAD system's setup error mean and standard deviation are the X axis($0.55{\pm}0.51mm$), Y axis($-0.2mm{\pm}0.523mm$), Z axis($-0.85{\pm}0.587mm$) in the phantom study, and in the patient study X axis($-0.05{\pm}0.621mm$), Y axis($0.075{\pm}0.755mm$) Z axis($-1.025{\pm}0.617mm$). So C-RAD system is better than 3-laser system mostly, but C-RAD system's error rate is a little worse than 3-laser system in the Z axis. When radiation treatment of head and neck, body surface contour scanning system contribute to correct positioning and minimize the set up error.

The Geometrical Mode Analysis of an Elastically Suspended Rigid Body with Planes of Symmetry (대칭면을 갖는 강체 진동계의 진동모드에 대한 기하학적 해석)

  • Dan, Byeong-Ju;Choe, Yong-Je
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.110-117
    • /
    • 2000
  • Vibration modes obtained from a modal analysis can be better explained from a screw theoretical standpoint. A vibration mode can be geometrically interpreted as a pure rotation about the vibration center in a plane and as the twisting motion on a screw in a three dimensional space. This paper, presents the method to diagonalize a spatial stiffness matrix by use of a parallel axis congruence transformation. It also describes that the stiffness matrix diagonalized by a congruence transformation, can have the planes of symmetry depending on the location of the center of elasticity. For a plane of symmetry, any vibration mode can be expressed by the axis of vibration. Analytical solutions for the axis of vibration has been derived.

3D Flow Characteristics of a Free-Horizontal-Axis-Turbine Tidal Power Generation System (자유수평축 조류발전 시스템의 3차원 유동특성)

  • Choi, Jin-Hyung;Doh, Deog-Hee;Jo, Hyo-Je;Lee, Yeon-Won;Suzuki, Kiyomi;Kato, Shinji
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.2
    • /
    • pp.51-55
    • /
    • 2010
  • Flow characteristics of a free-horizontal-axis-turbine (FHAT) current power generation system have been investigated by the use of a volumetric PTV. Three types of FHAT system (S50, SE50, S65) have been tested under the current speed 1.35 knot, 1.5 knot and 2 knot. The width of the blade installed around the body is 50 mm. Based upon the power generation characteristics of the FHAT, the flow features of the blade have been investigated. Among the three models it has been verified that the S65 is the most appropriate for power generations.

Predictive Spacecraft Attitude Control under External Disturbances

  • Sam, Myung-Hyun;Suk, Oh-Choong;Choong, Bang-Hyo;Jea, Tahk-Min
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.62.3-62
    • /
    • 2001
  • The predictive control is one of the nonlinear three-axis rotation methods. The desired trace of a satellite is pre-determined, and the control inputs are designed so that the satellite follows the ´predictive´ trace. The predictive control has been adapted to the research for the three-axis attitude control. In that case, the control variables are the quaternion represented the angular rates and attitude angles of the body about the three-axes. The objective of this paper is to propose to design a predictive controller for the three-axis attitude control under external disturbances. In order to do that, this paper proposes how to construct a predictive control law including disturbances and to discern them. The basic algorithm of the existent predictive control is partially modified, and the presumption and modeling of disturbances are performed ...

  • PDF

Development of an Equilibrium Sensation Measuring System for Human Being (사람의 평형감각 측정시스템 개발)

  • Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.62-69
    • /
    • 2009
  • This paper describes the development of the new type equilibrium sensation measuring system for human with handicap in the equilibrium sensation. The medium and small hospital could not use the developed equilibrium sensation measuring system, because it is very high prices. Therefore, the new type system should be developed to measure the numerical value of the equilibrium sensation in human with handicap. In this paper, First, two 3-axis force/moment sensors which can measure force Fz, moments Mx and My simultaneous were designed and manufactured, second, the high speed measuring device which can acquire the output from two 3-axis force/moment sensors, third, the new type equilibrium sensation measuring system was developed, then the characteristic test of the developed equilibrium sensation measuring system carried out, it is confirmed that the system could measure the swing body of human with handicap.

Development of a Hook-type Finger Force Measuring System with Force Sensors (힘센서를 이용한 후크형 손가락 힘 측정 장치 개발)

  • Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.6
    • /
    • pp.663-668
    • /
    • 2014
  • This paper presents a hook-type finger force measuring system with force sensors. The system is composed of a body, two three-axis force sensors, a hook, and so on. The two three-axis force sensors system was specially designed using FEM(Finite Element Method) and fabricated using strain-gages. The sensors measure the finger forces of both normal people and handicapped people in the system, and the forces are combined. The developed hook-type finger force measuring system can measure the pulling finger force of both normal and handicapped people. The pulling force tests of men and women were performed using the developed the system. It is thought that the developed system can be used to measure the pulling force of fingers.

A Design of an Algorithm for Analysis of Activity Using 3-Axis Accelerometer (3축 가속도 센서를 이용한 동작분석 알고리즘 설계)

  • 이승형;임예택;이경중
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.5
    • /
    • pp.361-367
    • /
    • 2004
  • This paper describes design of an algorithm for analyzing human activity using body-fixed 3-axis accelerometer in the small of the back. In the first step, we distinguish static and dynamic activity period using AC signal analysis. Then five postures were classified by applying the threshold in DC signal corresponding to the static activity period. Also, after comparison of average power and taking negative peak signal in the dynamic activity period, the four dynamic activities were classified by adaptive threshold method. To evaluate the performance of the proposed algorithm, the measured signals obtained from six subjects were applied to the proposed algorithm and the results were compared with the simultaneously measured video data. As a result, the activity classification rate of 95.7% on average was obtained. Overall results show that the proposed classification algorithm has a possibility to be used to analyze the static and dynamic physical activity.

Development of the Off-vertical Rotary Chair and Visual Stimulation system for Evaluation of the Vestibular Function (전정기능 평가를 위한 탈수직축 회전자극 시스템 및 HMD 시스템의 개발)

  • Kim Gyu-Gyeom;Ko Jong-Sun;Park Byung-Rim
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.377-380
    • /
    • 2001
  • The vestibular system located in the inner ear controls reflex body posture and movement. It has the semicircular canals sensing an angular acceleration and the otolith organs sensing a linear acceleration. With this organic signal, medical doctor decide if a person has disease or not. To obtain this data, a precision stimular system is considered. Robust control is needed to obtain eye signals induced by off-vertical axis rotation because of an unbalanced load produced by tilting the axis of the system upto 30 degrees. In this study, off-vertical axis rotatory system with visual stimulation system are developed. This system is consisted of head mounted display for generating horizontal, vertical, and three dimensional stimulus patterns. Furthermore wireless recording system using RF modem is considered for noiseless data transmission.

  • PDF

ON THE CURVATURE THEORY OF A LINE TRAJECTORY IN SPATIAL KINEMATICS

  • Abdel-Baky, Rashad A.
    • Communications of the Korean Mathematical Society
    • /
    • v.34 no.1
    • /
    • pp.333-349
    • /
    • 2019
  • The paper study the curvature theory of a line-trajectory of constant Disteli-axis, according to the invariants of the axodes of moving body in spatial motion. A necessary and sufficient condition for a line-trajectory to be a constant Disteli-axis is derived. From which new proofs of the Disteli's formulae and concise explicit expressions of the inflection line congruence are directly obtained. The obtained explicit equations degenerate into a quadratic form, which can easily give a clear insight into the geometric properties of a line-trajectory of constant Disteli-axis with the theory of line congruence. The degenerated cases of the Burmester lines are discussed according to dual points having specific trajectories.

Effects of Abnormal Neck Posture on Postural Stability (목 자세에 따른 선 자세에서의 신체균형능력 평가)

  • Park, Sung Ha
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.2
    • /
    • pp.16-23
    • /
    • 2018
  • Postural instability can increase the likelihood of hazardous slip and fall accidents in workplaces. The present study intended to extend understanding of the effect of abnormal neck posture on postural control during quiet standing. The effect of body fatigue on the postural control was also of primary concern. Twelve healthy undergraduate students volunteered to participate in the experiment. Standing on a force platform with the neck neutral, flexed, extended, or rotated, subjects' center of pressures (COP) were measured under the two levels of body fatigue. For the fatigue condition, Subjects exercised in a treadmill to meet the predetermined level of body fatigue. Analyzing the position coordinates of COPs, the length of postural sway path was assessed in both medio-lateral (ML) axis and anterior-posterior (AP) axis. Results showed that, in AP direction, neck extension or rotation significantly increased the sway length as compared with neck neutral. Neck extension led to greater sway length compared to neck rotation. Neck flexion did not differ from neck neutral. The sway length in the AP direction also became significantly larger as the body fatigue accumulated after treadmill exercise. In ML direction, as compared to neutral posture, the neck extension, flexion, or rotation did not significantly affect the length of postural sway path. However, the sway length seemed to increase marginally with the neck extended during the fatigued condition. This study demonstrates that abnormal neck posture may interfere with postural control during standing. The ability to maintain postural stability decreases significantly with the neck extended or rotated. Body fatigue leads to postural instability further.