• 제목/요약/키워드: axis alignment

검색결과 234건 처리시간 0.024초

극초정밀 다축 스테이지를 이용한 광소자 정렬 자동화에 관한 연구 (A Study on the Optical Element Alignment Automation using Multi-Axis Ultra Precision Stage)

  • 정상화;김광호
    • 한국공작기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.64-70
    • /
    • 2006
  • The optical element was usually used in optical devices and optical transfer devices, but it has been recently used in communication, computer and medical equipment. With the development of very high speed optical-communication, the development of the kernel parts of optical communication has also increased. Presently, the alignment of the optical element is time consuming, and an effective alignment algorithm has not yet to be developed. In this paper, the alignment automation of the optical element is studied. The ultra precision stage is applied to an optical element alignment to improve the accuracy of the alignment. The automation program of the optical element alignment is developed by LabVIEW programming to save the alignment time. The alignment algorithms of the optical element consist of field search and peak search algorithms.

단축이방성 배향막이 코팅되어 있는 다층박막시료의 타원식 (Ellipsometric Expressions of Multilayered Substrate Coated with a Uniaxially Anisotropic Alignment Layer)

  • 김상열
    • 한국광학회지
    • /
    • 제24권5호
    • /
    • pp.271-278
    • /
    • 2013
  • 다층박막이 있는 기층에 단축이방성 배향막이 코팅되어 있을 때 비스듬히 입사한 빛의 유효반사계수 표현들을 유도하였다. 유효반사계수들과 타원상수들을 다층박막의 미지상수들은 물론 단축이방성 배향막의 광학이방성의 크기와 광축의 방향 그리고 배향막의 두께로 표현하였다. 이를 바탕으로 배향막의 정상굴절률과 이상굴절률, 배향된 두께 그리고 광축의 방위각과 기울임각을 다층박막의 두께나 조성비 등과 함께 타원법이 가지고 있는 높은 수준의 측정 정밀도를 유지하며 기존의 모델링 분석방법으로 결정할 수 있도록 하였다.

30대 성인의 골반, 척추 및 견갑대 정렬의 패턴 분석 - Full Spine AP X-ray 분석에 따른 - (The Study on Static Alignment Classification based on the Full Spine AP X-ray of Adults aged 30-39)

  • 박지현;홍서영
    • 한방재활의학과학회지
    • /
    • 제20권2호
    • /
    • pp.89-99
    • /
    • 2010
  • Objectives : This study was designed to analyze the pattern of asymmetrical alignment. Methods : This study was carried out with the data from comprehensive medical testing. 91 subjects aged 30-39 were evaluated by full spine AP X-ray. For pelvis, innominate measurement(IM), off centering measurement(OCM), ilium shadow measurement(ISM), major axis of obturator foramen(MaF), minor axis of obturator foramen(MiF) were analyzed. Spinal curvature and height of shoulder girdle were analyzed. Results : 1. In pelvis, It. posterior-inferior and it. inflare combination pattern was 38 cases(42.8%). 2. In spinal curvature, "reverse S" curve was 45 cases(49.4%) and "reverse C" curve was 30 cases(33%). 3. In shoulder girdle, It. superior pattern was 42 cases(46.1 %) and It. superior pattern was 39 cases(42.9%). 4. In whole body analysis, It. posterior-inferior and It. inflare pelvis, "reverse S" spinal curvature and It. superior shoulder girdle combination patten was 11 cases(12.1 %). This pattern is similar to Kendall's right handedness pattern and Zink's common compensatory pattern. Conclusions : Results from this investigation showed asymmetrical alignment in 30-39 years-old adults. This results are expected to contribute to classifying the alignment pattern in clinic and systemic treatment.

A STUDY OF MAGNETIC ALIGNMENT OF DIE-UPSET Pr-Fe-B-Cu MAGNETS

  • Kwon, H.W.;Ma, T.J.;Harris, I.R.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.416-420
    • /
    • 1995
  • An attempt has been made to investigate the mechanism of magnetic alignment in the magnets produced by upset forging the $Pr_{20}Fe_{74}B_{4}Cu_{2}$ cast bulk alloy. Upset forging of the cast alloy was carried out for 20 sec to an 80 % thickness reduction (strain rate : $4{$\times}10^{-2}s^{-1}$) in an open die configuration at varying temperatures in the range $600^{\circ}-900^{\circ}C$. It has been found that the upset forging process at temperatures above $800^{\circ}C$ can achieve a magnetic alignment to a great extent from copper-containing Pr-Fe- B-type cast ingot. The growth manner of the ferromagnetic $Pr_{2}Fe_{14}B$ matrix grain in Pr-Fe-B-type alloys was studied by examining the morphology change of the matrix grain in sintered body, and it was found that the matrix grains grew in anisotropic manner such that the grain grew more rapidly along the a- or b-axis than along the c-axis. This anisotropic grain growth led to the plate-like shape of the matrix grain. The magnetic alignment during the upset forging was attributed to grain boundary gliding of the plate-like grains, and the geometry of the grains in the cast ingot and the presence of a large amount of the praseodymium-rich grain boundary phase were thought to play a key role in the achievement of magnetic alignment.

  • PDF

The effects of increased unilateral and bilateral calcaneal eversion on pelvic and trunk alignment in standing position

  • Yi, Jaehoon
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권2호
    • /
    • pp.84-88
    • /
    • 2016
  • Objective: Generally, it is known that there is a correlation between excessive calcaneus eversion and a patient with low back pain and it also affects pelvic alignment. However, there are not enough studies that show calcaneal eversion having an effect on the alignment of the trunk. Design: Cross-sectional study. Methods: A 3-dimensional motion analysis system was used to assess the lower limbs, pelvic alignment, and trunk alignment with increased unilateral and bilateral calcaneal eversion in twenty-one subjects. All subjects were asked to maintain a static posture for seven seconds on a wedge three times per posture for measurement and analysis purposes. The wedge used in the process was a lateral wedge with a 10-degree tilt to the lateral direction. To unify all of the subjects' foot position, the front and inner side of the wedge were marked. The height of the tilted wedge's inner side and flat wedge were balanced equally in order to be able to maintain the lateral part of the foot to the same height when producing an increased calcaneal eversion. Results: Comparing the changes in trunk and pelvic alignment in accordance to calcaneal eversion for each posture, there was a significant different in the X and Y-axis for each posture, but not in the Z-axis (p<0.05). Thus, it can be confirmed that calcaneal eversion in the sagittal plane and frontal plane may have and effect on the pelvis and the trunk. Conclusions: Postures with increased bilateral and unilateral calcaneal eversion has an effect on pelvic alignment, but does not cause any changes in trunk alignment.

수광각을 자동정렬하는 무선광검출기 (Automatic Angle Alignment of a Wireless Optical Detector)

  • 이성호
    • 한국전자파학회논문지
    • /
    • 제14권5호
    • /
    • pp.466-471
    • /
    • 2003
  • 본 논문에서는 포토다이오드의 방향이 항상 신호광의 입사방향과 일치하도록 수광각을 자동정렬하는 광검출기의 구조를 새로이 소개한다. 이 광검출기에서는 신호광을 수신하기 위한 포토다이오드 1개를 중심으로 $\Phi$-축상에 4개의 포토다이오드와 $\theta$-축상에 2개의 포토다이오드를 추가로 배열하여 각각 $\Phi$-축과 $\theta$-축에 해당하는 모터를 구동한다. 이 광검출기는 임의의 모든 방향으로부터 입사하는 신호광에 대하여 약 1초 이내에 수신방향을 신호광 쪽으로 일치시킨다.

광소자 정렬용 극초정밀 다축 위치 제어장치 개발 (Development of Multi-axis Nano Positioning Stage for Optical Alignment)

  • 정상화;이경형;차경래;김현욱;최석봉;김광호;박준호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.304-307
    • /
    • 2004
  • As optical fiber communication grows, the fiber alignment become the focus of industrial attention. This greatly influence the overall production rates for the opto-electric products. We proposed multi-axis nano positioning stage for optical fiber alignment. This device has 3 DOF translation and sub nanometer resolution. This nano stage consist of 3 PZT-driven flexure stages which are stacked parallel. The displacement of it is measured with capacitance gauge and is controlled by computer-embedded main controller. The design process of flexure stage using FEM is proposed and the performance evaluation of this system is verified with experiments.

  • PDF

광소자 정렬용 초정밀 다축 스테이지 개발 (Development of Multi-Axis Ultra Precision Stage for Optical Alignment)

  • 정상화;이경형;김광호;차경래;김현욱;최석봉;박준호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.213-218
    • /
    • 2004
  • As optical fiber communication grows, the fiber alignment become the focus of industrial attention. This greatly influence the overall production rates for the opto-electric products. We proposed multi-axis nano positioning stage for optical fiber alignment. This device has 3 DOF translation and sub nanometer resolution. This nano stage consist of 3 PZT-driven flexure stages which are stacked parallel. The displacement of it is measured with capacitance gauge and is controlled by computer-embedded main controller. The design process of flexure stage using FEM is proposed and the performance evaluation of this system is verified with experiments.

  • PDF

Ellipsometric Characterization of Rubbed Polyimide Alignment Layer in Relation with Distribution of Liquid Crystal Molecules in Twisted Nematic Cell

  • Cho, Sung Yong;Park, Sang Uk;Yang, Sung Mo;Kim, Sang Youl
    • Current Optics and Photonics
    • /
    • 제2권2호
    • /
    • pp.185-194
    • /
    • 2018
  • Ultra-small optical anisotropy of a rubbed polyimide (PI) alignment layer is quantitatively characterized using the improved reflection ellipsometer. Twisted nematic (TN) cells are fabricated using the rubbed PIs of known surface anisotropy as alignment layers. Distribution of liquid crystal (LC) molecules in the TN cell is characterized using transmission ellipsometry. The retardation of the rubbed PI surface increases as rubbing strength increases. The tilt angle of the optic axis of the rubbed PI surface decreases as rubbing strength especially as the angular speed of the rubbing roller increases. Pretilt angle of LC molecules in the TN cell shows strong correlation with tilt angle of the optic axis of the rubbed PI surface. Both the apparent order parameter and the effective twist angle of the LC molecules in the TN cell decrease as the pretilt angle of LC molecules increases.

Improved Differential Wavefront Sampling algorithm for efficient alignment of Space optical system

  • Kim, Yun-Jong;Yang, Ho-Soon;Lee, Yun-Woo;Kim, Sug-Whan
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.34.4-35
    • /
    • 2008
  • The significant I&T process gain represented by reduction in overall budget expenditure can be obtained from the use of efficient alignment technique for large space optical systems. Such process gain tends to increase rapidly with an increase in aperture and/or in number of optical elements within the system. However, in practice, the alignment of multiple optical components tends to be rather difficult task because of the multiple coupling effects among the elements within the target system. In order to understand and hence identify the complex interplay of the wavefront coupling effects from the alignment process, the original differential wavefront sampling(DWS) method was presented elsewhere in recent years. DWS uses partial differential of the wavefront of optical component and perturbation value of the optical component against a particular alignment factor. The straightforward application of DWS for an off-axis optical system revealed that it tends to give incorrect estimation of the given misalignment state. In this study, we added off-axis correction terms to the original DWS algorithm and investigated its alignment performance. The performance simulation result for a Korsch type space optical system shows that the modified DWS is capable of bringing the misaligned system into the target alignment tolerance only after 3 iterations. It also shows that this new improved algorithm can be used to estimate the source misalignment as well. We are planning to apply this method for the alignment of a 800mm Korsch type telescope in the near future. We discuss the computational technique, simulation results and implications in details.

  • PDF