• 제목/요약/키워드: axial magnetization

검색결과 20건 처리시간 0.025초

Thrust Hybrid Magnetic Bearing using Axially Magnetized Ring Magnet

  • Park, Cheol Hoon;Choi, Sang Kyu;Ahn, Ji Hoon;Ham, Sang Yong;Kim, Soohyun
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.302-307
    • /
    • 2013
  • Hybrid-type magnetic bearings using both permanent magnets and electromagnets have been used for rotating machinery. In the case of conventional thrust hybrid magnetic bearings supporting axial loads, radially magnetized permanent ring magnets, which have several demerits such as difficult magnetization and assembly, have been used to generate bias flux. In this study, a novel thrust hybrid magnetic bearing using an axially magnetized permanent ring magnet is presented. Because it is easy to magnetize a ring magnet in the axial direction, the segmentation of the ring magnet for magnetization is not required and the assembly process can be simplified. For verifying the performance of the proposed method, a test rig that consists of a proposed thrust magnetic bearing and variable loads is constructed. This paper presents the detailed design procedures and the obtained experimental results. The results show that the developed thrust magnetic bearing has the potential to replace conventional thrust magnetic bearings.

Comparative Study of Flux Regulation Methods for Hybrid Permanent Magnet Axial Field Flux-switching Memory Machines

  • Yang, Gongde;Fu, Xinghe;Lin, Mingyao;Li, Nian;Li, Hao
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.158-167
    • /
    • 2019
  • This research comparatively studies three kinds of flux regulation methods, namely, stored capacitor discharge pulse (SCDP), constant current source pulse (CCSP), and quantitative flux regulation pulse (QFRP), which are used for hybrid permanent magnet (PM) axial field flux-switching memory machines (HPM-AFFSMMs). Through an analysis of the operation principle and the series hybrid PM flux regulation mechanism of the objective machine, the circuit topologies and flux regulation process of these flux regulation methods are addressed in detail. On the basis of a simulation, the flux regulation characteristics of the researched machine during the magnetization and demagnetization processes are comparatively evaluated. Then, machine performance, including back EMF, direct and quadrature axis inductances, and magnetization and demagnetization characteristics, is quantitatively investigated. Results show that the QFRP enables the HPM-AFFSMM to achieve a less harmonic component of back EMF by approximately 7.28% and 7.97% at the magnetization and demagnetization states, respectively, and a more complete magnetization process than the SCDP and CCSP.

Postcontrast T1-weighted Brain MR Imaging in Children: Comparison of Fat-suppressed Imaging with Conventional or Magnetization Transfer Imaging

  • 이충욱;구현우;최충곤
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.37-37
    • /
    • 2003
  • To assess the merits and demerits of postcontrast fat-suppressed (FS) brain MR imaging in children in the evaluation of various enhancing lesions, compared with postcontrast conventional or Magnetization Transfer (MT) imaging. 대상 및 방법: We reviewed patients with enhancing lesion on brain MR imaging who underwent both FS imaging and one of conventional or MT imaging as a postcontrast T1-weighted brain MR imaging. Inclusion criteria of our study were as follows: MR studies should be peformed within one-year interval and showed no significant interval change of imaging findings. Thirty-four patients (21 male, 13 female; mean age, 8 years) with 43 enhancing lesions (19 intra-axial, 19 extra-axial, and 5 orbital location) were included in this study, Twenty-one pairs of FS and conventional imaging, and 15 pairs of FS and MT imaging were available. Two radiologists visually assessed the lesion conspicuity and the presence of flow or susceptibility artifacts in a total of 36 pairs of MR imaging by consensus. For 21 measurable lesions (19 pairs of FS and conventional imaging, 5 pairs of FS and MR imaging), contrast ratio between the lesion and the normal brain( [SIlesion-SIwater]/[SInormal brain-SIwater]) were calculated and compared.

  • PDF

Disk형 단상 SRM의 기본 특성 해석을 위한 자화곡선 측정 (Magnetization Curves Measurement for Fundamental Characteristics Analysis of Disk-type Single Phase SRM)

  • 이충원;이종한;이은웅;오영웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.91-93
    • /
    • 2003
  • Disk type Single Phase SRM(Switched Reluctance Motor) can be used axial direction magnetic flux and radial direction magnetic flux. In this paper, the flux linkage was measured according as rotor positions of disk-tyre single phase SRM, which is designed and manufactured in previous research. From the measured data, we got the magnetization curves, inductance profile and Co-energy.

  • PDF

YBCO Bulk 초전도체 교류손실의 주파수 의존성 (Frequency dependence of AC loss in YBCO Bulk superconductor)

  • 예정희;나완수;김찬중;홍계원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 1999
  • In this paper, we investigated the frequency dependences of AC loss and the magnetic properties of a superconductor using magnetization method. We used the YBCO bulk superconductor sample which has a square-shaped cross sectional area of $6mm{\times}6mm$. and 43mm-long in axial direction. The applied AC magnetic field was parallel to the direction of sample axis. It is observed that YBCO bulk has the diamagnetic properties. AC loss calculation of YBCO bulk superconductor was performed by evaluating the total area of magnetization traces. We performed two cases of experiments, one for $B_m<B_p$ and the other for $B_m<B_p$. The experiments showed that the AC loss dependences on frequency were different in each mode, as was indicated in other publications.

  • PDF

심장 내 이식형 축류 혈액 펌프용 자성 유체 축봉의 내압 특성 (Characteristics of the Sealing Pressure of a Magnetic Fluid Shaft Seal for Intra-Cardiac Axial Flow Blood Pumps)

  • 김동욱
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권10호
    • /
    • pp.477-482
    • /
    • 2002
  • One of the key technologic requirements for rotary blood pumps is the sealing of the motor shaft. A mechanical seal, a journal bearing, magnetic coupling, and magnetic suspension have been developed, but they have drawbacks such as wear, thrombus formation, and power consumption. A magnetic fluid seal is durable, simple, and non power consumptive. Long-term experiments confirmed these advantages. The seal body was composed of a Nd-Fe-B magnet and two pole pieces; the seal was formed by injecting magnetic fluid into the gap (50${\mu}m$) between the pole pieces and the motor shaft. To contain the ferro-fluid in the seal and to minimize the possibility of magnetic fluid making contact with blood, a shield with a small cavity was attached to the pole piece. While submerged in blood, the sealing pressure of the seal was measured and found to be 31kPa with magnetic fluid LS-40 (saturated magnetization, 24.3 KA/m) at a motor speed of 10,000 rpm and 53kPa under static conditions(0mmHg). The specially designed magnetic fluid seal for keeping liquids out is useful for axial flow blood pumps. The magnetic fluid seal was incorporated into an intra-cardiac axial flow blood pump.

Carotid Intraplaque Hemorrhage Imaging: Diagnostic Value of High Signal Intensity Time-of-Flight MR Angiography Compared with Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequencing

  • Ahn, Ji-eun;Kwak, Hyo Sung;Chung, Gyung Ho;Hwang, Seung Bae
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권2호
    • /
    • pp.94-101
    • /
    • 2018
  • Purpose: To determine the value of the appearance of the high signal intensity halo sign for detecting carotid intraplaque hemorrhage (IPH) on maximum intensity projection (MIP) of time-of-flight (TOF) MR angiography (MRA), based on high signal intensity on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequencing. Materials and Methods: A total of 78 carotid arteries in 65 patients with magnetization-prepared rapid acquisition gradient-echo (MPRAGE) positive on carotid plaque MR imaging were included in this study. High-resolution MR imaging was performed on a 3.0-T scanner prior to carotid endarterectomy or carotid artery stenting. Fast spin-echo T1- and T2-weighted axial imaging, TOF, and MPRAGE sequences were obtained. Carotid plaques with high signal intensity on MPRAGE > 200% that of adjacent muscle on at least two consecutive slices were defined as showing IPH. Halo sign of high signal intensity around the carotid artery was found on MIP from TOF MRA. Continuous and categorical variables were compared among groups using the Mann-Whitney test and Fisher's exact tests. Results: Of these 78 carotid arteries, 53 appeared as a halo sign on the TOF MRA. The total IPH volume of patients with a positive halo sign was significantly higher than that of patients without a halo sign ($75.0{\pm}86.8$ vs. $16.3{\pm}18.2$, P = 0.001). The maximum IPH axial wall area in patients with a positive halo sign was significantly higher than that of patients without a halo sign ($11.3{\pm}9.9$ vs. $3.7{\pm}3.6$, P = 0.000). Conclusion: High signal intensity halo of IPH on MIP of TOF MRA is associated with total volume and maximal axial wall area of IPH.

Dependence of Harmonics Profiles on Domain Dynamics in Current-Carrying Iron Whisker

  • KIm, C.G.;Kim, D.Y.;Ryu, K.S.;Yang, Y.S.;Lee, J.G.
    • Journal of Magnetics
    • /
    • 제1권2호
    • /
    • pp.60-63
    • /
    • 1996
  • The first and second harmonics have been measured in the iron whisker with the axial current that produces a circular field. The observed harmonics profiles have been discussed in terms of theoretical analysis based on the nonlinear, asymmetric magnetization that are related to the nucleation, transformation and annihilation of domains. The change of second harmonics profile is more sensitive to the domain variation than that of first harmonics.

  • PDF

Back EMF Design of an AFPM Motor using PCB Winding by Quasi 3D Space Harmonic Analysis Method

  • Jang, Dae-Kyu;Chang, Jung-Hwan;Jang, Gun-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.730-735
    • /
    • 2012
  • This paper presents a method to design the waveform of a back electromotive force (back EMF) of an axial flux permanent magnet (AFPM) motor using printed circuit board (PCB) windings. When the magnetization distribution of permanent magnet (PM) is given, the magnetic field in the air gap region is calculated by the quasi three dimensional (3D) space harmonic analysis (SHA) method. Once the flux density distribution in the winding region is determined, the required shape of the back EMF can be obtained by adjusting the winding distribution. This can be done by modifying the distance between patterns of PCB to control the harmonics in the winding distribution. The proposed method is verified by finite element analysis (FEA) results and it shows the usefulness of the method in eliminating a specific harmonic component in the back EMF waveform of a motor.