• Title/Summary/Keyword: axial length

Search Result 918, Processing Time 0.028 seconds

Size Effect on Axial Compressive Strength of Concrete (콘크리트의 축압축강도에 대한 크기효과)

  • 이성태;김민욱;김진근
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.153-160
    • /
    • 2001
  • In this study, the size effect on axial compressive strength for concrete members was experimentally investigated. Experiment of mode I failure, which is one of the two representative compressive failure modes, was carried out by using double cantilever beam specimens. By varying the eccentricity of applied loads with respect to the axis on each cantilever and the initial crack length, the size effect of axial compressive strength of concrete was investigated, and new parameters for the modified size effect law (MSEL) were suggested using least square method (LSM). The test results show that size effect appears for axial compressive strength of cracked specimens. For the eccentricity of loads, the influence of tensile and compressive stress at the crack tip are significant and so that the size effect is present. In other words, if the influence of tensile stress at the crack tip grows up, the size effect of concrete increases. And the effect of initial crack length on axial compressive strength is present, however, the differences with crack length are not apparent because the size of fracture process zone (FPZ) of all specimens in the high-strength concrete is similar regardless of differences of specimen slenderness.

Camera Focal Length Measuring Method and 3-Dimension Image Correspondence of the Axial Motion Model on Stereo Computer Vision (3-Dimension 영상을 이용한 카메라 초점측정 및 동일축 이동 모델의 영상 정합)

  • 정기룡
    • Journal of the Korean Institute of Navigation
    • /
    • v.16 no.3
    • /
    • pp.77-85
    • /
    • 1992
  • Camera arrangement for depth and image correspondence is very important to the computer vision. Two conventional comera arrangements for stereo computer vision are lateral model and axial motion model. In this paper, using the axial motion stereo camera model, the algorithm for camera focal length measurement and the surface smoothness with the radiance-irradiance is proposed fro 3-dimensional image correspondence on stereo computer vision. By adapting the above algorithm, camera focal length can be measured precisely and the resolution of 3-dimensional image correspondence has been improved comparing to that of the axial motion model without the radiance-irradiance relation.

  • PDF

Correlation of Refractive Error, Axial Length, Chamber Depth, Lens Thickness and Corneal Thickness of Normal University Students (정상 대학생의 눈 굴절이상, 안축장, 전방깊이, 수정체두께 그리고 각막두께의 연관성)

  • Kim, Chang-Sik;Lee, Hak-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.89-94
    • /
    • 2008
  • Purpose: To make a comparative study of correlation between biometry data of size in eyeball and refractive error. Methods: The subjects were 68 normal university students (male 36, female 32) and the average age was 22.85${\pm}$3.12. We measured the students' eyesight by A-scan ultrasound and refractor. The results were examined it's statistical significance by SPSS 12.0 version. Results: The mean of axial length was 24.31${\pm}$1.24 mm, chamber depth was 3.48${\pm}$0.28 mm, lens thickness was 3.56${\pm}$0.26 mm and corneal thickness was 0.55${\pm}$0.03 mm. Male's Axial length and chamber depth were larger than female's. As reflective error decreases the thickness of lens become thicker. The measurement data between right eye and left eye didn't had difference and there was no correlation with result of T-test. There were statistically significant correlation with length and chamber depth, axial length and corneal thickness, chamber depth and corneal thickness, and refractive error and lens thickness (p<0.01). Refractive error and axial length were minus linear regression (r=-0.56). Conclusions: Eye's refractive error was changed by axial length, chamber depth and lens thickness but it wasn't related with sex and whether it is a right eye or a left eye.

  • PDF

Optimum Design of Axial-Flow Fans Including Noise Parameters (소음파라메터를 고려한 축류송풍기의 최적설계)

  • Son, B.J.;Lee, S.H.;Yoon, S.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.1-12
    • /
    • 1995
  • In order to seek various relationships among many design parameters employed in the design of the axial-flow fans the program which generates acoustic spectrum has been developed and its validity verified. Outputs of the program, with other outputs from a formerly developed performance prediction program, have been used to form a multi-objective function, for which an optimal design process was carried out. The present analysis shows that overall noise level and efficiency has contrasting trends, and the chord length turns out to be the most critical design variable. In the chosen design case of requirements $Q=2000m^2/min$, ${\Delta}P_s=67mmAq$, D=1.4m, the chord length of 0.2059m minimizes the overall noise level, while chord length of 0.1254m maximizes the efficiency. The resulting chord length in the balanced optimization is 0.1809m.

  • PDF

MCST bending formulation of a cylindrical micro-shell based on TSDT

  • Mohammad Arefi
    • Earthquakes and Structures
    • /
    • v.26 no.4
    • /
    • pp.299-309
    • /
    • 2024
  • The present paper develops application of third-order shear deformation theory (TSDT) and modified couple stress theory (MCST) to size-dependent bending analysis of a functionally graded cylindrical micro-shell. The radial and axial displacement components are described based on TSDT for more accurate analysis. The effect of small scales is accounted based on MCST. The principle of virtual work is used for derivation of bending governing equations. The solution is presented for a simply-supported boundary condition to account the influence of various important parameters such as micro length scale parameter, in-homogeneous index and some dimensionless geometric parameters such as length to radius and length to thickness ratios on the bending results. A comparative analysis is presented to examine the effect of order of employed shear deformation theory on the axial and radial displacements.

Effect of Pitch Angle and Blade Length on an Axial Flow Fan Performance (피치각과 날개 길이에 따른 축류팬의 성능)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2013
  • In this study, the performance of an impeller according to blade length and pitch angle was studied experimentally by building a variable pitch impeller while changing blade length to review the effect of blade length and pitch angle on a fan's performance. The pitch angle was changed in six steps from $20^{\circ}{\sim}45^{\circ}$ at intervals of $5^{\circ}$ while the blade lengths were changed to 90 mm, 100 mm, 110 mm and 120 mm with an identical airfoil shape while carrying out the experiment. The results are summarized as follows: The air flow per static pressure of axial fans increased linearly with increase of pitch angle, but the high static pressure showed a decrease at a pitch angle of $35^{\circ}$. The shaft power increased proportionally to the pitch angle at all blade lengths; the larger the pitch angle, the larger the measured increase of shaft power. This is because the drag at the fan's front increases with the pitch angle. In the axial fans considered in this research, the flow and increase of static pressure amount increased up to a pitch angle of $30^{\circ}$ but decreased rapidly above $35^{\circ}$.

The Correlation of Refractive Error and Ocular Dimensions in Older Age (고령의 연령에서 굴절이상과 안광학 성분들의 연관성 분석)

  • Lim, Byung Kwan;Jeon, Soon-Woo;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.293-297
    • /
    • 2011
  • Purpose: This study was to know the correlation among refractive error and the dimensions of ocular components on older adults. Methods: The subjects were 95 older age who had no eye diseases. The refractive error, corneal radius, corneal diopter, axial length, anterior chamber depth and lens thickness were measured and analysed. Results: The axial length(AL)/corneal radius(CR) ratio was positively correlated with the corneal diopter, axial length, the anterior chamber depth. Then it was negatively correlated with corneal radius. It was shown that the highest correlation was between the corneal diopter and axial length (r = -0.545, p = 0.000). The spherical equivalent of the refractive error was negatively correlated with the AL/CR ratio. Conclusions: It was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive error of the old age.

A Study of the One-Stage Axial Turbine Performance with Various Axial Gap Distances between the Stator and Rotor (정.동익 축방향 간격에 따른 단단 축류터빈의 성능시험에 관한 연구)

  • Kim, Dong-Sik;Cho, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.99-105
    • /
    • 2002
  • The performance test of an axial-type turbine is carried out with various axial gap distances between the stator and rotor. The turbine is operated at the low pressure and speed, and the degree of reaction is 0.373 at the mean radius. The axial-type turbine consists of ons-stage and 3-dimensional blades. The chord length of rotor is 28.2mm and mean diameter of turbine is 257.56mm. The power of turbo-blower for input power is 30kW and mass flow rate is $340m^3$/min at 290mmAq static-pressure. The RPM and output power are controlled by a dynamometer connected directly to the turbine shaft. The axial gap distances are changed from a quarter to three times of stator axial chord length, and performance curves are obtained with 9 different axial gaps. The efficiency varies about 8% of its peak value due to the variation of axial gap on the same non-dimensional mass flow rate and RPM, and experimental results show that the optimum axial gap is 1.6-1.9Cx.

Effective length factor for columns in braced frames considering axial forces on restraining members

  • Mahini, M.R.;Seyyedian, H.
    • Structural Engineering and Mechanics
    • /
    • v.22 no.6
    • /
    • pp.685-700
    • /
    • 2006
  • The effective length factor is a familiar concept for practicing engineers and has long been an approach for column stability evaluations. Neglecting the effects of axial force in the restraining members, in the case of sway prevented frames, is one of the simplifying assumptions which the Alignment Charts, the conventional nomographs for K-Factor determination, are based on. A survey on the problem reveals that the K-Factor of the columns may be significantly affected when the differences in axial forces are taken into account. In this paper a new iterative approach, with high convergence rate, based on the general principles of structural mechanics is developed and the patterns for detection of the critical member are presented and discussed in details. Such facilities are not available in the previously presented methods. A constructive methodology is outlined and the usefulness of the proposed algorithm is illustrated by numerical examples.

Plastic hinge length of circular reinforced concrete columns

  • Ou, Yu-Chen;Kurniawan, Raditya Andy;Kurniawan, Dimas Pramudya;Nguyen, Nguyen Dang
    • Computers and Concrete
    • /
    • v.10 no.6
    • /
    • pp.663-681
    • /
    • 2012
  • This paper presents a parametric study of the plastic hinge length of circular reinforced concrete columns using a three-dimensional finite element analysis method, and using the Taguchi robust design method to reduce computational cost. Parameters examined include the longitudinal reinforcing ratio, the shear span-to-depth ratio, the axial force ratio and the concrete compressive strength. The study considers longitudinal reinforcement with yield strengths of 414 MPa and 685 MPa, and proposes simplified formulas for the plastic hinge length of circular reinforced concrete columns, showing that increases in plastic hinge length correlate to increases in the axial load, longitudinal reinforcing and shear span-to-depth ratios. As concrete strength increases, the plastic hinge length decreases for the 414 MPa case but increases for the 685 MPa case.