Seismic performance of 1/4-scale RC frames subjected to axial and cyclic reversed lateral loads

  • Bechtoula, Hakim;Sakashita, Masanobu;Kono, Susumu;Watanabe, Fumio
    • Computers and Concrete
    • /
    • 제2권2호
    • /
    • pp.147-164
    • /
    • 2005
  • This paper summarizes an experimental study on the seismic behavior of lower stories of a mid-rise reinforced concrete frame building. Two reinforced concrete frames with two stories and one span were tested and each frame represents lower two stories of an 11-story RC frame building. Both frames were designed in accordance with Japanese design guidelines and were identical except in the variation of axial force. The tests demonstrated that the overall load-displacement relations of the two frames were nearly the same and the first-story column shear was closely related to the column axial load. The columns and beams elongated during both of the tests, with the second-floor beam elongation exceeding 1.5% of the beam clear span length. The frame with higher axial loads developed more cracks that the frame under moderate axial load.

변환각 트러스 모델에 의한 철근콘크리트 기둥의 전단거동 예측 (Shear Behavior Prediction of Reinforced Concrete Columns Using Transformation Angle Truss Model)

  • 김상우;채희대;이정윤;이범식
    • 콘크리트학회논문집
    • /
    • 제17권3호
    • /
    • pp.435-444
    • /
    • 2005
  • 본 연구에서는 휨모멘트와 축력의 효과가 고려된 변환각 트러스 모델(TATM)을 이용하여 철근콘크리트 기둥의 전단거동을 예측하였다. TATM의 해석결과를 검증하기 위하여 다양한 전단경간비와 축력비를 가지는 총 9개의 철근콘크리트 기둥을 전단 실험하였다. 철근콘크리트 기둥의 곡률, 축변형 및 전단변형을 측정하기 위하여 기둥 옆면 전단위험단면을 중심으로 5개의 변위변환기(LVDT)를 설치하였다. 하중은 최대하중의 $85\%$ 이하로 떨어질 때까지 가력하였으며, 모든 실험체는 휨 철근의 항복이전에 전단파괴 되었다. 기둥의 전단강도와 강성은 축 하중이 증가할수록 증가하는 반면 전단경간비가 증가할수록 감소하였다. TATM으로부터 얻은 전단응력-전단변형률 관계와 전단응력-전단철근변형률 관계는 본 연구에서 수행된 실험결과와 잘 일치하였으며, 기존의 트러스 모델(MCFT, RA-STM, FA-STM)보다 더 우수하였다.

SM570TMC강을 이용한 콘크리트충전강관 합성기둥의 설계기준 항복강도 (The Specified Minimum Yield Stress of SM570TMC in CFT Composite Columns)

  • 이명재
    • 한국강구조학회 논문집
    • /
    • 제20권1호
    • /
    • pp.205-213
    • /
    • 2008
  • SM570TMC 강재를 합성부재로 사용할 경우, KBC2005 0709에 따라 ${415N/mm^{2}}$를 초과하지 못한다. 이는 일반 강구조의 경우의항복강도 ${440N/mm^{2}}$에 미치지 못한다. 따라서 본 연구는 순수강재 (원형강관, 각형강관) 단주 압축실험과 충전형 합성부재 단주, 장주 압축실험을 통하여 SM570TMC강을 충전형 합성기둥으로 사용할 때, 항복강도를 저감시키지 않고 일반 강구조의 공칭강도를 그대로 사용할 수 있는지를 정량적으로 평가하는데 그 목적이 있다.

A curvature method for beam-column with different materials and arbitrary cross-section shapes

  • Song, Xiaobin
    • Structural Engineering and Mechanics
    • /
    • 제43권2호
    • /
    • pp.147-161
    • /
    • 2012
  • This paper presents a curvature method for analysis of beam-columns with different materials and arbitrary cross-section shapes and subjected to combined biaxial moments and axial load. Both material and geometric nonlinearities (the p-delta effect in this case) were incorporated. The proposed method considers biaxial curvatures and uniform normal strains of discrete cross-sections of beam-columns as basic unknowns, and seeks for a solution of the column deflection curve that satisfies force equilibrium conditions. A piecewise representation of the beam-column deflection curve is constructed based on the curvatures and angles of rotation of the segmented cross-sections. The resulting bending moments were evaluated based on the deformed column shape and the axial load. The moment curvature relationship and the beam-column deflection calculation are presented in matrix form and the Newton-Raphson method is employed to ensure fast and stable convergence. Comparison with results of analytic solutions and eccentric compression tests of wood beam-columns implies that this method is reliable and effective for beam-columns subjected to eccentric compression load, lateral bracings and complex boundary conditions.

철근콘크리트 교량의 단순화된 내진응답해석 (Simplified Seismic Response Analysis of a RC Bridge)

  • 이도형;전종수;박대효
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.949-954
    • /
    • 2003
  • In this paper, simplified modeling approach describing the hysteretic behavior of reinforced concrete columns is discussed. The inelastic response of a reinforced concrete column or pier subjected to cyclic deformation reversals or earthquake ground motion is evaluated by use of lumped hysteretic representation. For this purpose, the hystertic model under axial force variation is developed and implemented into a nonlinear finite element analysis program. The analytical predictions obtained with the new formulation are compared with test results and reveal accuracy and applicability in terms of strength and stiffness. In addition, comparison between results with and without axial force variation stresses the importance of the proposed approach.

  • PDF

다 경간 압축재의 하중-진동수 관계 (Load-Frequency Relationships of Continuous Compression Members)

  • 이수곤;김순철;임동혁
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.335-340
    • /
    • 1998
  • The apparently different physical problems of lateral vibration and elastic stability of a linear member are limiting cases of a single phenomenon, the more general expression being the mode of vibration with end thrust. For a single-span beam-column, it is generally known that the square of the frequency of lateral vibration is approximately linearly related to compressive axial force. In this paper the relationship between the frequency and axial force of multi-span compression members is investigated by means of the finite element method.

  • PDF

Studies on restoring force model of concrete filled steel tubular laced column to composite box-beam connections

  • Huang, Zhi;Jiang, Li-Zhong;Zhou, Wang-Bao;Chen, Shan
    • Steel and Composite Structures
    • /
    • 제22권6호
    • /
    • pp.1217-1238
    • /
    • 2016
  • Mega composite structure systems have been widely used in high rise buildings in China. Compared to other structures, this type of composite structure systems has a larger cross-section with less weight. Concrete filled steel tubular (CFST) laced column to box-beam connections are gaining popularity, in particular for the mega composite structure system in high rise buildings. To enable a better understanding of the destruction characteristics and aseismic performance of these connections, three different connection types of specimens including single-limb bracing, cross bracing and diaphragms for core area of connections were tested under low cyclic and reciprocating loading. Hysteresis curves and skeleton curves were obtained from cyclic loading tests under axial loading. Based on these tested curves, a new trilinear hysteretic restoring force model considering rigidity degradation is proposed for CFST laced column to box-beam connections in a mega composite structure system, including a trilinear skeleton model based on calculation, law of stiffness degradation and hysteresis rules. The trilinear hysteretic restoring force model is compared with the experimental results. The experimental data shows that the new hysteretic restoring force model tallies with the test curves well and can be referenced for elastic-plastic seismic analysis of CFST laced column to composite box-beam connection in a mega composite structure system.

철근이 부식된 철근콘크리트 기둥의 구조성능 평가에 대한 실험적 연구 (An Experimental Study on Evaluation of Structural Performance on Corroded Reinforced Concrete Columns)

  • 원종호;한남희;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.711-717
    • /
    • 2000
  • This paper presents an experimental study on evaluation of structural performance on corroded reinforced concrete columns under only axial load, combined axial load and lateral load. This test was carried on the twenty-six reinforced concrete columns with $150\times150\times800$mm size subjected to combined axial load and lateral load. Effects of key variables such as the corrosion level, the number of hoop, the corrosion of hoop are studied in this program. The results of this study show that the capacity of column axial force was decreased as corrosion level was increased, especially, rapid development was shown after 10% corrosion level and the maximum moment capacity of column was shown at corrosion level 1.2%, while rapid decrease was shown after 4.3% corrosion level. Also we found that influence of corrosion was decreased to number of tie bar was increased.

  • PDF

고강도 콘크리트 기둥단면의 축력-모멘트 강도에 관한 연구 (A Study on Axial Force - Moment Capacity of High-Strength Concrete Tied Column Sections)

  • 박해균;박동규;박영식;손영현;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.300-305
    • /
    • 1996
  • Reinforced concrete column is an effective structural element to take advantage of high strength concrete. This paper presents an experimental and analytical strength of high strength concrete rectangular tied column sections under eccentric loading. The test variables are concrete strength, steel ratios, slenderness and eccentricity. The analytical results of the ACI's rectangular stress block, Zia's modified rectangular stress block, and a trapezoid block are compared with experimentally obtained data. It may be concluded that the trapezoid stress block provided the most reasonable column section capacities for high strength concrete columns.

  • PDF

주상복합구조에서 전이보와 내부기둥 접합부의 반복횡하중 실험 (Cyclic Loading Test of Interior Deep-Beam Lower-Column Joint in Upper-shear Wall Lower-Frame Structure)

  • 이한선;김상연;고동우;권기혁;최성모
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.446-451
    • /
    • 2000
  • In case of strong earthquake, upper-sheat wall lowe-frame structures show the weak-story failure at lower part. Where we should guarantee sufficient strength, energy dissipation capacity and ductility. In this study, a typical structure was selected for a prototype and four 1:2.5 scaled models, representing the subassemblages including the interior column and the deep beam, were constructed. Experimental parameters include transverse reinforcement ratio and axial force. The non- linear behavior of the subassemblages subjected to the cyclic lateral displac-ement were evaluated through investigation of the ultimate strength, ductility, load-deformation characteristics. From the results of the tests on 4 specimens, it is concluded that the strength increased as the axial force increased and the ductility increased as the transverse reinforcement ratio increased.

  • PDF