Extracting Foundation Input Motion Considering Soil-Subterranean Level Kinematic Interaction (지하층-지반 운동학적 상호작용을 고려한 기초저면의 설계지반운동 산정)

  • Sadiq, Shamsher;Yoon, Jinam;Kim, Juhyong;Park, Duhee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.11
    • /
    • pp.31-37
    • /
    • 2018
  • Most of tall building systems are composed of above-ground structure and underground structure used for parking and stores. The underground structure may have a pronounced influence on tall building response, but its influence is still not well understood. In a widely referred report on seismic design of tall buildings, it is recommended to model the underground structure ignoring the surrounding ground and to impose input ground motion calculated considering the underground structure-soil kinematic interaction between at its base. In this study, dynamic analyses are performed on 1B and 5B basements. The motions at the base are calculated to free field responses. The motions are further compared to two procedures outlined in the report to account for the kinematic interaction. It is shown that one of the procedure fits well for the 1B model, whereas both procedures provide poor fit with 5B model analysis result.

Studies on the Hemodilution Perfusion with Rygg-Kyvsgaard Oxygenator (혈액희석 체외순환법에 관한 임상적 관찰 -상온하 Rygg-Kyvsgaard 산화기 및 Sigmamotor pump 사용예를 중심으로-)

  • 손광현
    • Journal of Chest Surgery
    • /
    • v.3 no.2
    • /
    • pp.73-90
    • /
    • 1970
  • Clinical perfusion data on 16 cases of cardiopulmonary bypass using Sigmamotor pump and RyggKyvsgaard Oxygenator which performed at Seoul National University Hospital during the period of Aug. 1968 to Aug. 1970 was analized. AIl cases were hemodiluted and the perfusion was carried out under the normothermic condition. The age of the patients ranged between 6 and 43 years. The b:dy weight varied between 18.3 and 54.0 kg and the body surface area between 0.78 and 1. 59$M^2$. The priming solution was consiste:I with fresh ACD blood. Hartmann solution and Mannitol. The average amount of priming was approximately 2242 ml. The average hemodilution rate was 17%. The flow rate ranged from 1.7L to 3.5L/Min/$M^2$ and averaged 2.4L/Min/$M^2$ or 78mI/Min/kg. The duration of perfusion varied from 22 to 110 min with average of 56.9 minutes. Some hemodynamic responses were observed. The arterial pressure dropped immediately after the initiation of partial perfusion and was more marked after the total perfusion foIlowed by gradual increase to the safety level. The central venous pressure reflected the reduced blood volume especially in the cases of prolonged perfusion which lasted over 60 min. In most of the cases, red blood cell count decreased and white blood ceIl count increased after the perfusion. Hemoglobin level was decreased, averaging of 12.5mg%, Hct 3.3% and platelets count of 18% postoperatively. Plasma hemoglobin increased mildly, from pre-perfusion average value of 4. 06mg% to postperfusion value of 22.5mg%. Serum potassium was 4.4mEq/L pre-operatively and was decreased to 3.7mEq/L postoperatively. Five cases showed definite hypopotassemia immediately after the operation. Sodium and chloride decreased mildly. These electrolyte changes are thought to be related with hemodilution. diuretics and reduced blood volume during and after the perfusion. Arterial blood pH value revealed minimal to moderate elevation from preperfusion average value of 7.376 to 7.461 during perfusion and then 7.365 after perfusion. The pC02 and hicarbonate showed minimal to moderately lowered values. The total CO2 was decreased. Buffer base decreased during perfusion (Av. 42.6mEq/L) and further decreased after the perfusion (Av. 40.8mEq/L). These arterial blood acid base changes suggested that the metabolic acidosis was accompanied by respiratory alkalosis during and immediately after the perfusion. Authors belived that the acidosis could more effectively be corrected with the more additional dose of bicarbonate than we used by this study. The chest tune drainage during the first 24 hours following operation was 1158 ml in average. One case (Case No. 15) showd definite bleeding tendency and it was believed that the cause might be due to the defect of heparin and protamine titration. The average urinary out put during 24 hours post-perfusion was 1291ml. One case (Case No. ]) showed definite post perfusion oliguria. As conclusion hemodilution using fresh ACD blood. Hartmann and Mannitol solution added with Bivon and high flow rate unler normothermia. was thought to amelioratc the severity of mctabolic acidosis during and after perfusion with relatively satisfactory effect on the diuresis and bleeding tendency.

  • PDF

Cognitive-Motor Interaction-Based Instrument Playing for Improving Early Social Skills of Children With Autism Spectrum Disorder (ASD 아동의 초기 사회기술 향상을 위한 인지-운동 통합 기반 악기연주 중재)

  • Yu, Hyun Kyung
    • Journal of Music and Human Behavior
    • /
    • v.20 no.1
    • /
    • pp.75-97
    • /
    • 2023
  • This study aimed to investigate the effect of cognitive-motor interaction-based instrument playing on the early social skills of children with autism spectrum disorder (ASD). Nine children with ASD, averaging 5.6 years of age, participated in twelve individual sessions lasting 30 minutes each. The intervention comprised five stages: self-regulation, motivation to engage in social interaction, acceptance of a partner in co-playing activities, interpersonal coordination with a partner, and engagement in joint music playing. To evaluate changes in early social skills, joint attention and social interaction behaviors were observed, and the Social Responsiveness Scale (SRS-2) was administered pre- and post-intervention. Social synchronization was measured through a dyadic drum task, measuring synchronization accuracy, duration, and timing. Following the intervention, all nine children demonstrated increased early social behaviors, although there were no significant differences in SRS scores. Moreover, synchronized movement improved significantly in accuracy and maintained duration but not in reaction time. This study highlights the significance of recognizing the cognitive-motor interplay as crucial element in facilitating early social skills development in children with ASD.

Effect of the Various Sources of Dietary Additives on Growth, Body Composition and Shell Color of Abalone Haliotis discus hannai (다양한 원료의 사료첨가제가 전복의 성장, 체조성 및 패각 색채에 미치는 영향)

  • Cho, Sung-Hwoan;Park, Jung-Eun;Kim, Chung-Il;Yoo, Jin-Hyung;Lee, Sang-Min;Choi, Cheol-Young
    • Journal of Aquaculture
    • /
    • v.19 no.4
    • /
    • pp.275-280
    • /
    • 2006
  • Effect of the various sources of dietary additives on growth, body composition and shell color of abalone Haliotis discus hannai was investigated for 16 weeks. Forty juvenile abalone averaging 13.5 g were randomly stocked into 21 of 50 L plastic rectangular containers each. Eight kinds of additives were prepared for this study: four commercially available microalgae [Haeatococcus (Hae), Isochrysis galbana (Iso), Shizochytrium (Sch) and Spirulina (Spi)], three crustacean meals [krill meal (KM), shrimp head meal (Shm) and red crab meal (Rcm)], and green tea by-product (Gre). In addition, dry sea tangle (Dst), Laminaria japonica, as a control, was prepared. Casein, dextrin and a mixture corn oil and fish oil was protein, carbohydrate and lipid sources, respectively, in the experimental diets. The 2% each additive was included into the experimental diets. The experimental diets were fed to abalone once a day at the ratio of $1.5{\sim}2.0%$ total biomass of abalone with a little leftover throughout the 16-week feeding trial. Survival of abalone was not significantly (P>0.05) affected by the experimental diets. However, weight gain of abalone fed the all experimental diets containing the various sources of additives was significantly (P<0.05) higher than that of abalone fed the Dst diet. Weight gain of abalone fed the Spi diet was highest and Shi, KM and Iso diets in order. Shell length and the ratio of soft body weight to body weight of abalone was not significantly (P>0.05) affected by the experimental diets. However, shell width of abalone fed the all experimental diets containing the various sources of additives was significantly (P<0.05) higher than that of abalone fed the Dst diet. The shell color of abalone fed the Spi diet was improved the most distinctively and similar to that of natural abalone. Therefore, it can be concluded that the experimental diets with the various sources of additives (microalgae and crustacean meals) was effective to improve growth of abalone and dietary inclusion of Spirulina was most effective to improve shell color of abalone.

Evaluation of Antidepressant Drug Effect in a Depressive Animal Model by Proton MR Spectroscopy (양성자 자기공명분광법을 이용한 우울증 동물모델에서의 항우울제 약물 효능 평가)

  • Kim, Sang-Young;Choi, Chi-Bong;Lee, Sung-Ho;Woo, Dong-Cheol;Yoon, Seong-Ik;Hong, Kwan-Soo;Lee, Hyun-Sung;Cheong, Chae-Joon;Jee, Bo-Keun;Hong, Sung-Tak;Kim, Hwi-Yool;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.95-101
    • /
    • 2008
  • In this study, we observed the alteration of choline signal intensity in hippocampus region of the depressive rat model induced by forced swimming test (FST). The purpose of this study was to evaluate the antidepressant efficacy in the depressive animal model using MR spectroscopy. Fourteen experimentally naive male Sprague-Dawley rats weighting $160{\sim}180\;g$ were used as subjects. Drug injection group was exposed to the FST except for control group. The drugs were administered subcutaneously (SC) in a volume equivalent to 2ml/kg. And three injections were administered 23, 5, and 1h before beginning the given test. 1H MR spectra were obtained with use of a point resolved spectroscopy (PRESS) localization sequence performed according to the following parameters: repetition time, 2500 ms; echo time, 144 ms; 512 average; 2048 complex data points; voxel dimensions, $1.5{\times}2.5{\times}2.5\;mm^3$ ; acquisition time, 25min. There were no differences in NAA/Cr and Cho/Cr ratio between the right and the left hippocampus both normal control rats and antidepressant-injected rats. Also, no differences were observed in NAA/Cr and Cho/Cr ratio between the normal control rats and the antidepressant-injected rats both the right and the left hippocampus. In this study, we found the recovery of choline signals in the depressive animal model similar to normal control groups as injecting desipramine-HCl which was antidepressant causing anti-immobility effects. Thus, we demonstrated that MR spectroscopy was able to aid in evaluating the antidepressant effect of desipramine-HCl.

  • PDF

Study on the Small Fields Dosimetry for High Energy Photon-based Radiation Therapy (고에너지 광자선을 이용한 방사선 치료 시 소조사면에서의 흡수선량평가에 관한 연구)

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.290-297
    • /
    • 2009
  • In case of radiation treatment using small field high-energy photon beams, an accurate dosimetry is a challenging task because of dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons, and non-uniformity between the detector and the phantom materials. In this study, the absorbed dose in the phantom was measured by using an ion chamber and a diode detector widely used in clinics. $GAFCHROMIC^{(R)}$ EBT films composed of water equivalent materials was also evaluated as a small field detector and compared with ionchamber and diode detectors. The output factors at 10 cm depth of a solid phantom located 100 cm from the 6 MV linear accelerator (Varian, 6 EX) source were measured for 6 field sizes ($5{\times}5\;cm^2$, $2{\times}2\;cm^2$, $1.5{\times}1.5\;cm^2$, $1{\times}1\;cm^2$, $0.7{\times}0.7\;cm^2$ and $0.5{\times}0.5\;cm^2$). As a result, from $5{\times}5\;cm^2$ to $1.5{\times}1.5\;cm^2$ field sizes, absorbed doses from three detectors were accurately identified within 1%. Wheres, the ion chamber underestimated dose compared to other detectors in the field sizes less than $1{\times}1\;cm^2$. In order to correct the observed underestimation, a convolution method was employed to eliminate the volume averaging effect of an ion chamber. Finally, in $1{\times}1\;cm^2$ field the absorbed dose with a diode detector was about 3% higher than that with the EBT film while the dose with the ion chamber after volume correction was 1% lower. For $0.5{\times}0.5\;cm^2$ field, the dose with the diode detector was 1% larger than that with the EBT film while dose with volume corrected ionization chamber was 7% lower. In conclusion, the possibility of $GAFCHROMIC^{(R)}$ EBT film as an small field dosimeter was tested and further investigation will be proceed using Monte Calro simulation.

  • PDF

Analysis of Quantization Noise in Magnetic Resonance Imaging Systems (자기공명영상 시스템의 양자화잡음 분석)

  • Ahn C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.42-49
    • /
    • 2004
  • Purpose : The quantization noise in magnetic resonance imaging (MRI) systems is analyzed. The signal-to-quantization noise ratio (SQNR) in the reconstructed image is derived from the level of quantization in the signal in spatial frequency domain. Based on the derived formula, the SQNRs in various main magnetic fields with different receiver systems are evaluated. From the evaluation, the quantization noise could be a major noise source determining overall system signal-to-noise ratio (SNR) in high field MRI system. A few methods to reduce the quantization noise are suggested. Materials and methods : In Fourier imaging methods, spin density distribution is encoded by phase and frequency encoding gradients in such a way that it becomes a distribution in the spatial frequency domain. Thus the quantization noise in the spatial frequency domain is expressed in terms of the SQNR in the reconstructed image. The validity of the derived formula is confirmed by experiments and computer simulation. Results : Using the derived formula, the SQNRs in various main magnetic fields with various receiver systems are evaluated. Since the quantization noise is proportional to the signal amplitude, yet it cannot be reduced by simple signal averaging, it could be a serious problem in high field imaging. In many receiver systems employing analog-to-digital converters (ADC) of 16 bits/sample, the quantization noise could be a major noise source limiting overall system SNR, especially in a high field imaging. Conclusion : The field strength of MRI system keeps going higher for functional imaging and spectroscopy. In high field MRI system, signal amplitude becomes larger with more susceptibility effect and wider spectral separation. Since the quantization noise is proportional to the signal amplitude, if the conversion bits of the ADCs in the receiver system are not large enough, the increase of signal amplitude may not be fully utilized for the SNR enhancement due to the increase of the quantization noise. Evaluation of the SQNR for various systems using the formula shows that the quantization noise could be a major noise source limiting overall system SNR, especially in three dimensional imaging in a high field imaging. Oversampling and off-center sampling would be an alternative solution to reduce the quantization noise without replacement of the receiver system.

  • PDF

Effect of Feeding Frequency of Extruded Diets Containing Different Macro-nutrient Levels on Apparent Nutrient Digestibility in Grower Flounder Paralichthys olivaceus (영양소 함량이 다른 부상 배합사료의 공급횟수가 육성기 넙치의 영양소 소화율에 미치는 영향)

  • Seo, Joo-Young;Choi, Kyoung-Hyun;Choi, Jin;Lee, Sang-Min
    • Journal of Aquaculture
    • /
    • v.18 no.3
    • /
    • pp.160-166
    • /
    • 2005
  • Two feeding trials were carried out to investigate apparent nutrient digestibility of flounder fed experimental diets containing different levels of macro-nutrients by satiation feeding rate (Exp-1) and feeding frequency (Exp-2). Triplicate groups of fish averaging 280 g were fed three experimental diets which contained different levels of carbohydrate, protein and lipid by two feeding regimes (satiation and 80% satiation) and four feeding frequencies (three meals a day, two meals a day, one meal a day and one meal every two days). Feces were collected using a fecal collection column attached to fish rearing tanks for 6 weeks. Apparent digestibilities of dry matter, protein, lipid, energy and carbohydrate were not affected by feeding satiation rate in Exp-1. Apparent protein digestibility was not affected by feeding frequency, whereas affected by dietary composition in Exp-2. Apparent protein digestibility of fish fed a high-protein diet showed a tendency to become higher compared to that of fish fed high-carbohydrate diet and high-lipid diet at the same feeding frequency. Apparent lipid digestibility was not affected by dietary composition, however, affected by feeding frequency. Apparent digestibilities of energy and carbohydrate were affected by both dietary composition and feeding frequency. Apparent digestibities of energy and carbohydrate in fish fed the high-protein diet showed a tendency to become higher compared to that of fish fed the high-carbohydrate diet and high-lipid diet at the same feeding frequency. Apparent digestibities of energy and carbohydrate tended to decrease with increasing of feeding frequency at the same dietary composition.

Classification of Seismic Stations Based on the Simultaneous Inversion Result of the Ground-motion Model Parameters (지진동모델 파라미터 동시역산을 이용한 지진관측소 분류)

  • Yun, Kwan-Hee;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.3
    • /
    • pp.183-190
    • /
    • 2007
  • The site effects of seismic stations were evaluated by conducting a simultaneous inversion of the stochastic point-source ground-motion model (STGM model; Boore, 2003) parameters based on the accumulated dataset of horizontal shear-wave Fourier spectra. A model parameter $K_0$ and frequency-dependent site amplification function A(f) were used to express the site effects. Once after a H/V ratio of the Fourier spectra was used as an initial estimate of A(f) for the inversion, the final A(f) which is considered to be the result of combined effect of the crustal amplification and loca lsite effects was calculated by averaging the log residuals at the site from the inversion and adding the mean log residual to the H/V ratio. The seismic stations were classified into five classes according to $logA_{1-10}^{max}$(f), the maximum level of the site amplification function in the range of 1 Hz < f < 10 Hz, i.e., A: $logA_{1-10}^{max}$(f) < 0.2, B: 0.2 $\leq$ $logA_{1-10}^{max}$(f) < 0.4, C: 0.4 $\leq$ $logA_{1-10}^{max}$(f) < 0.6, D: 0.6 $\leq$ $logA_{1-10}^{max}$(f) < 0.8, E: 0.8 $\leq$ $logA_{1-10}^{max}$(f). Implication of the classified result was supported by observing a shift of the dominant frequency of average A(f) for each classified stations as the class changes. Change of site classes after moving seismic stations to a better site condition was successfully described by the result of the station classification. In addition, the observed PGA (Peak Ground Acceleration)-values for two recent moderate earthquakes were well classified according to the proposed station classes.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.