• Title/Summary/Keyword: average jitter

Search Result 66, Processing Time 0.026 seconds

A Study of Acoustic Measurement in Connected Speech with Dysphonia (음성장애 연속구어의 음향학적 분석)

  • Lee, Myoung-Soon
    • Phonetics and Speech Sciences
    • /
    • v.3 no.4
    • /
    • pp.109-115
    • /
    • 2011
  • The purposes of this study were to identify acoustic parameters of connected speech and to contribute to acoustic analysis of dysphonic voice about patient's natural speech voice as well as sustained phonation of vowels. Acoustic parameters of sentences included LTAS (long-term average spectrum) mean and spectral slope over frequence ranges such as 0-4kHz, 0-6kHz, 0-8kHz, 0-12.5kHz as well as HNR. Acoustic parameters of the vowel 'a' included jitter, RAP, shimmer, NHR, and HNR. Based on 'G' of GRBAS for the severity of dysphonia, two experienced raters judged and classified as four groups including controls, mild, moderate and severe dysphonic group. Connected speech was two sentences extracted from 'stroll' passage. Parameters of the vowel and LTAS mean of the sentences were measured by CSL. The spectral slope of the sentences and HNR of the vowel and the sentences were measured by Praat. Data were statistically analyzed by Spearman correlation and Kruskal-Wallis test using SPSS 12.0. The results of this study are as follows: First, jitter, RAP, shimmer and NHR were significantly different between the groups. Second, for several frequencies, LTAS mean and spectral slope of the sentences were significantly different between the groups. Third, the HNR of the sentences were significantly different between the groups. Forth, there was a presence of correlation between HNR and NHR of the vowel and HNR of the sentences. Accordingly, this study concluded that LTAS, spectral slope, and HNR were predictive parameters of connected speech voice for dysphonic voice.

  • PDF

Adaptive OLSR Protocol Based on Average Node Distance in Airdropped Distributed Mobility Model (분산 낙하 이동 모델에서의 평균 노드 거리 기반 적응적 OLSR 프로토콜)

  • Lee, Taekmin;Lee, Jinhae;Wang, Jihyeun;Yoo, Joonhyuk;Yoo, Seong-eun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.2
    • /
    • pp.83-91
    • /
    • 2018
  • With the development of IT (Information Technology) technology, embedded system and network technology are combined and used in various environments such as military environment as well as everyday life. In this paper, we propose a new airdropped distributed mobility model (ADMM) modeling the dispersion falling of the direct shot of a cluster bomb, and we compare and analyze some representative MANET routing protocols in ADMM in ns-3 simulator. As a result of the analysis, we show OLSR routing protocol is promising in ADMM environment in the view points of packet delivery ratio (PDR), end to end delay, and jitter. In addition, we propose a new adaptation scheme for OLSR, AND-OLSR (Average Node Distance based adaptive-OLSR) to improve the original OLSR in ADMM environment. The new protocol calculates the average node distance, adapts the period of the control message based on the average node distance increasing rate. Through the simulation study, we show that the proposed AND-OLSR outperforms the original OLSR in PDR and control message overhead.

On Benchmarking of Real-time Mechanisms in Various Periodic Tasks for Real-time Embedded Linux (실시간 임베디드 리눅스에서 다양한 주기적 타스크의 실시간 메커니즘 성능 분석)

  • Koh, Jae-Hwan;Choi, Byoung-Wook
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.4
    • /
    • pp.292-298
    • /
    • 2012
  • It is a real-time system that the system correctness depends not only on the correctness of the logical result of the computation but also on the result delivery time. Real-time Operating System (RTOS) is a software that manages the time of a microprocessor to ensure that the most important code runs first so that it is a good building block to design the real-time system. The real-time performance is achieved by using real-time mechanisms through data communication and synchronization of inter-task communication (ITC) between tasks. Therefore, test on the response time of real-time mechanisms is a good measure to predict the performance of real-time systems. This paper aims to analysis the response characteristics of real-time mechanisms in kernel space for real-time embedded Linux: RTAI and Xenomai. The performance evaluations of real-time mechanism depending on the changes of task periods are conducted. Test metrics are jitter of periodic tasks and response time of real-time mechanisms including semaphore, real-time FIFO, Mailbox and Message queue. The periodicity of tasks is relatively consistent for Xenomai but RTAI reveals smaller jitter as an average result. As for real-time mechanisms, semaphore and message transfer mechanism of Xenomai has a superior response to estimate deterministic real-time task execution. But real-time FIFO in RTAI shows faster response. The results are promising to estimate deterministic real-time task execution in implementing real-time systems using real-time embedded Linux.

Development of medical/electrical convergence software for classification between normal and pathological voices (장애 음성 판별을 위한 의료/전자 융복합 소프트웨어 개발)

  • Moon, Ji-Hye;Lee, JiYeoun
    • Journal of Digital Convergence
    • /
    • v.13 no.12
    • /
    • pp.187-192
    • /
    • 2015
  • If the software is developed to analyze the speech disorder, the application of various converged areas will be very high. This paper implements the user-friendly program based on CART(Classification and regression trees) analysis to distinguish between normal and pathological voices utilizing combination of the acoustical and HOS(Higher-order statistics) parameters. It means convergence between medical information and signal processing. Then the acoustical parameters are Jitter(%) and Shimmer(%). The proposed HOS parameters are means and variances of skewness(MOS and VOS) and kurtosis(MOK and VOK). Database consist of 53 normal and 173 pathological voices distributed by Kay Elemetrics. When the acoustical and proposed parameters together are used to generate the decision tree, the average accuracy is 83.11%. Finally, we developed a program with more user-friendly interface and frameworks.

A low noise PLL with frequency voltage converter and loop filter voltage detector (주파수 전압 변환기와 루프 필터 전압 변환기를 이용한 저잡음 위상고정루프)

  • Choi, Hyek-Hwan
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.1
    • /
    • pp.37-42
    • /
    • 2021
  • This paper presents a jitter and phase noise characteristic improved phase-locked loop (PLL) with loop filter voltage detector(LFVD) and frequency voltage converter(FVC). Loop filter output voltage variation is determined through a circuit made of resistor and capacitor. The output signal of a small RC time constant circuit is almost the same as to loop filter output voltage. The output signal of a large RC time constant circuit is the average value of loop filter output voltage and becomes a reference voltage to the added LFVD. The LFVD output controls the current magnitude of sub-charge pump. When the loop filter output voltage increases, LFVD decreases the loop filter output voltage. When the loop filter output voltage decreases, LFVD increases the loop filter output voltage. In addition, FVC also improves the phase noise characteristic by reducing the loop filter output voltage variation. The proposed PLL with LFVD and FVC is designed in a 0.18um CMOS process with 1.8V power voltage. Simulation results show 0.854ps jitter and 30㎲ locking time.

Acoustic Characteristics of Patients with Total Laryngectomees via Voice Rehabilitation Techniques (후두적출술 환자의 발성법에 따른 음향학적 특성)

  • Jang, Hyo-Ryung;Shim, Hee-Jeong;Ko, Do-Heung
    • Phonetics and Speech Sciences
    • /
    • v.5 no.4
    • /
    • pp.25-32
    • /
    • 2013
  • This research is aimed at finding the acoustic characteristics of different voice rehabilitation techniques, the electrolaryx (EL), standard esophageal (SE), and tracheoesophageal (TE), used on 17 patients with laryngectomees. The analysis of the voice qualities was achieved using MDVP. In order to compare the acoustic characteristics, patients were asked to produce the vowel /a/ sound. The acoustic analysis included fundamental frequency (f0), jitter, shimmer, and noise-to-harmonic ratio (NHR). The main acoustic results showed no significant statistical differences between the average measurements of SE and TE speakers. It was found that the current study showed the same tendency found in previous studies. There was also a significant difference between SE and EL speakers. On the other hand, there were no significant statistical differences between the average measurements of TE and EL speakers on all acoustic measurements. This research will contribute to establishing a baseline related to speech characteristics in voice rehabilitation for patients with laryngectomees. In future, the present findings and issues should be considered in the context of gender. Specifically, the number of women who are diagnosed with laryngeal cancer continues to rise and their acoustic characteristics may indeed differ from those of men.

CLSR: Cognitive Link State Routing for CR-based Tactical Ad Hoc Networks

  • Ahn, Hyochun;Kim, Jaebeom;Ko, Young-Bae
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.1
    • /
    • pp.50-67
    • /
    • 2015
  • The Cognitive Radio (CR) paradigm in tactical ad hoc networks is an important element of future military communications for network-centric warfare. This paper presents a novel Cognitive Link State Routing protocol for CR-based tactical ad hoc networks. The proposed scheme provides prompt and reliable routes for Primary User (PU) activity through procedures that incorporate two main functions: PU-aware power adaptation and channel switching. For the PU-aware power adaptation, closer multipoint relay nodes are selected to prevent network partition and ensure successful PU communication. The PU-aware channel switching is proactively conducted using control messages to switch to a new available channel based on a common channel list. Our simulation study based on the ns-3 simulator demonstrates that the proposed routing scheme delivers significantly improved performance in terms of average end-to-end delay, jitter, and packet delivery ratio.

Effect of Scan-bias during Reset Period in a Negative Waveform

  • Park, W.H.;Lee, S.J.;Lee, J.Y.;Kang, J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.728-731
    • /
    • 2009
  • A negative waveform having inverted polarity of conventional waveform during reset and sustain periods was proposed to improve the driving characteristics. In order to control the negative wall-charge distribution, a positive bias on the scan electrode was applied during reset period. Compared to 0 V scan-bias condition, at 8 V scan-bias the formative time lag was improved about 23.95 % and the average time lag was improved about 14.91 %. All experiments were performed with the 42-inch PDP module in XGA resolution.

  • PDF

Changes in Acoustic Parameters According to Intensity Increase in Voice Assessment (음성질환자의 음성검사 시 강도 증가에 따른 음향학적 지표의 변화)

  • Nam, Do-Hyun;Rheem, Sung-Sue;Yun, Bo-Ram;Cho, Sun-A;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.2
    • /
    • pp.143-150
    • /
    • 2011
  • Background and Objectives : Clinically, as a tool for voice assessment before and after the operation or the voice treatment, acoustic analysis is widely used. However, in clinical situations, acoustic parameters vary according to how the assessment is made. Thus, with voice disease patients as subjects, we are to investigate what influence intensity increase exerts on acoustic parameters and how to reduce variation according to the way of assessing. Material and Method : At the voice clinic of the department of otorhinolaryngology in Gangnam Severance Hospital, with 30 female voice-disease patients (40.6 years old on the average) and 23 male voice-disease patients (40.1 years old on the average) as subjects, using the Dr Speech vocal-assessment program, we statistically tested the significance of the difference in each of acoustic parameters between when the "Ah" vowel is produced with a normal voice and when the "Ah" vowel is produced with a loud voice. Results : Acoustic parameters that showed a statistically significant difference according to intensity increase were Jitter, SD F0, and NNE for females, and Jitter, SD F0, HNR, SNR, and NNE for males. Voice quality estimates showed a statistically significant difference according to intensity increase in female hoarse voice, female breathy voice, and male breathy voice. Conclusion : In this research, acoustic analysis, which is generally used for voice assessment before and after the operation or the voice treatment, showed a tendency that acoustic parameters became better under the influence of intensity increase except for the cases where a voice disease was severe. Thus, to raise the reliability of voice assessment, the range of intensity needs to be set up. This should be the topic for the future research.

  • PDF

The Effect of the Treatment on the Pre- and Post Respiration and the Oral Motor for Children with Cerebral Palsy by Acoustic Analysis (음향학적 분석을 통한 뇌성마비 아동의 호흡 및 구강 운동 전.후 치료 효과)

  • Kim, Sook-Hee;Kim, Hyun-Gi;Shin, Yong-Il
    • Speech Sciences
    • /
    • v.15 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • The purpose of this study was to find out the acoustic variation on the pre-and post respiration and oral motor for children with cerebral palsy. Five children with spastic CP at the age of 6 in average were practiced by a caregiver at home each for 25 minutes, in total, 45 times. The sustained of vowel /a/ and vowels /a/, /i/, /u/, /e/, /o/ were recorded on CSL and MDVP and analyzed by acoustic parameters. As a result, the maximum phonation time(MPT) was increased from 2.06 to 6.31 and the formant of vowels(F1, F2, F3) had significant differences in F1(/a, i/), F2(/i.u.o/), and F3(/a/) between the controls and the children with CP in pre-treatment. The total average value of vowels had significant differences between the pre-and post-treatment (p< .05). The energy of vowels had significant differences in the vowels /i, u, e, o/ and the total average value between the pre-and post-treatment(p< .001). The jitter percent, shimmer percent, and noise to harmonic ratio had significant differences between the pre-and post-treatment(p< .05). As the respiration and the oral motor improved MPT, voice quality, and articulation of vowel, and the variation of the formant(F1, F2, F3) showed the changes in the shape of lips, the place and the height of the tongue, the various development of therapy programs and the consistent intervention of treatment is needed for the children with cerebral palsy.

  • PDF