• Title/Summary/Keyword: average filter

Search Result 902, Processing Time 0.03 seconds

Culture of Nile Tilapia (Oreochromis niloticus) in Recirculating Aquaculture System (순환여과식 양식 시스템에서 나일 틸라피아(Oreochromis niloticus)의 사육)

  • Seo Kuen Hack;Kim Byong Jin;Jo Jae Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.1
    • /
    • pp.27-34
    • /
    • 2002
  • The performances of fish culture were evaluated in the integrated recirculating aquaculture system consisting of a double drain type rearing tank ($2.5 m^3$), a sedimentation tank, a floating bead filter, a foam separator and a rotating biological contactor. A system was stocked with nile tilapia at an initial rearing densities of $5\%$ (A), $5\%$ (B) and $7\%$ (C) oyer 30 days. Feed coefficient was 1.62, 1,79 and 1.80 and average daily growth rate was $0.452\%$, 0.u5% and $0.423\%$, respectively. The level of TAN was maintained below $1 g/m^3$ for $5\%$ of initial rearing density and $2-4 g/m^3$ for $7\%$. The dissolved oxygen level ($2-4 g/m^3$) was not optimum but should not be inhibitory to fish growth. The total suspended solid was completely removed during overall experimental period.

A Study on the Concentration Distribution of Airborne Heavy Metals in Major Industrial Complexes in Korea (국내 주요 산업단지 대기 중 중금속농도 분포에 관한 연구)

  • Kang, Byung-Wook;Kim, Min-Ji;Baek, Kyung-Min;Seo, Young-Kyo;Lee, Hak Sung;Kim, Jong-Ho;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.269-280
    • /
    • 2018
  • This paper reports the results of field evaluation to determine the levels of heavy metals in major industrial complexes in Korea over a seven year period (2007~2013). The measurement of heavy metal was conducted using quartz fiber filter sampling and ICP-AES analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control(QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of total suspended particulates (TSP) for the nine industrial complexes in Korea were $104{\sim}169{\mu}g/m^3$, which was higher than other industrial complexes and urban areas. The Sihwa and Banwol industrial complexes were shown to be the biggest contributing sources to high TSP emission ($159{\mu}g/m^3$ and $169{\mu}g/m^3$, respectively). The concentrations of heavy metals in TSP were higher in the order of Fe>Cu>Zn, Pb, Mn>Cr, Ni, As and Cd. It was observed that Fe was the highest in the Gwangyang and Pohang steel industrial complexes. The concentrations of Zn and Pb were high in Onsan, Sihwa and Banwol industrial complexes, and this was attributed to the emission from the nonferrous industry. Additionally, Cr and Ni concentrations were high in the Sihwa and Banwol industrial complexes due to plating industry. On the other hand, Ulsan and Onsan industrial complexes showed high Cr and Ni concentrations as a response to the emission of metal industry related to automobile. The correlation analysis revealed the high correlation between Cr and Ni in plating industry from Sihwa and Banwol industrial complexes. Adding to this, components related to coal combustion and road dust showed high correlation in Pohang and Gwangyang industrial complexes. Then Onsan and Ulsan industrial complexes showed high correlation among components related to the nonferrous metals.

A Study on Real-time Implementing of Time-Scale Modification (음성 신호 시간축 변환의 실시간 구현에 관한 연구)

  • Han, Dong-Chul;Lee, Ki-Seung;Cha, Il-Hawan;Youn, Dae-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.50-61
    • /
    • 1995
  • A time scale modification method yielding rate-modified speech while conserving the characteristic of speech was implemented in real-time using a goneral purpose digital signal processor. Time scale modification changed pronunciation speed only, producing a time difference between the input signal and the modified signal, making it impossible to implement it in real-time. In this thesis, a system was implemented to remove the time difference between the input and modified signals. Speech signals slowed down or speeded up by a physical time scale modification method, such as adjusting the motor speed of the cassett tape recorder, was used as the input signal. Physical modification that controled only the inter speed of the cassette tape player distorted the pitch period of the original speech. In this study, a real-time system was implemented so that the pitch-distorted speech was reconstructed back to the original by fractional sampling pitch shifting using an FIR filter, and this signal was time scale modified to match the cassette tape recorder motor speed using SOLA time-scale medification. In experiments using speech signals medifiedby the proposed method, results obtained using a 16-bit resolution ADSP2101 processor and using computer simulations employing floating point operations showed about the same average frame signal-to-noise ratio of about 20 dB.

  • PDF

Smoothed Group-Sparsity Iterative Hard Thresholding Recovery for Compressive Sensing of Color Image (컬러 영상의 압축센싱을 위한 평활 그룹-희소성 기반 반복적 경성 임계 복원)

  • Nguyen, Viet Anh;Dinh, Khanh Quoc;Van Trinh, Chien;Park, Younghyeon;Jeon, Byeungwoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.173-180
    • /
    • 2014
  • Compressive sensing is a new signal acquisition paradigm that enables sparse/compressible signal to be sampled under the Nyquist-rate. To fully benefit from its much simplified acquisition process, huge efforts have been made on improving the performance of compressive sensing recovery. However, concerning color images, compressive sensing recovery lacks in addressing image characteristics like energy distribution or human visual system. In order to overcome the problem, this paper proposes a new group-sparsity hard thresholding process by preserving some RGB-grouped coefficients important in both terms of energy and perceptual sensitivity. Moreover, a smoothed group-sparsity iterative hard thresholding algorithm for compressive sensing of color images is proposed by incorporating a frame-based filter with group-sparsity hard thresholding process. In this way, our proposed method not only pursues sparsity of image in transform domain but also pursues smoothness of image in spatial domain. Experimental results show average PSNR gains up to 2.7dB over the state-of-the-art group-sparsity smoothed recovery method.

Concentration Characteristics of Atmospheric PM2.5, PM10 and TSP during the Asian Dust Storm in Iksan Area (익산지역에서 황사발생시 PM2.5, PM10 TSP의 농도 특성)

  • Kang, Gong-Unn;Kim, Nam-Song;Kim, Kyung-Suk;Kim, Mi-Kyung;Lee, Hyun-Ju
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.5
    • /
    • pp.408-421
    • /
    • 2007
  • The concentration characteristics of atmospheric particle matters (PM) including $PM_{2.5},\;PM_{10}$, and TSP were evaluated through the measurement data of PM_{2.5}$ (fine particulate), PM_{10-2.5}$ (coarse particulate), and PM_{over-10}$ collected using a MCI (multi-nozzle cascade impactor) sampler of a three-stage filter pack in spring of 2006 in Iksan area. During the sampling period of 10-15 March and 24 days from 8 April to 2 May, 32 samples for PM of each size fractions were collected, and then measured for PM mass concentrations and water-soluble inorganic ion species. Average concentrations of $PM_{2.5},\;PM_{10}$, TSP were $57.9{\pm}44.1mg/m^3$, $96.6{\pm}89.1mg/m^3$, and $114.8{\pm}99.7mg/m^3$, respectively. Water-soluble inorganic ion fractions to PM mass were found to be 36.5%, 18.0%, and 11.1% for $PM_{2.5}$, $PM_{10-2.5}$ and $PM_{over-10}$, respectively. By showing the high concentrations of PM samples during Asian dust events, those three fractions of PM were distinguished between the samples of Asian dust event and the samples of no event. However, the increase of PM concentrations observed during Asian dust events showed a different pattern for some Asian dust events. The differences of those three fractions in the size distribution may depend on differences on place of occurrence of Asian dust storm and course of transport from China continent to Iksan area in Korea. However, the extent of PM mass contribution during Asian dust events was generally dominated by the coarse particles rather than the fine fraction of PM. The variations of water-soluble inorganic ion species concentration in those three PM fractions between the samples of Asian dust event and the samples of no event were also discussed in this study.

A Study on the Removal Efficiency of Harmful Pollutants in the Cooking Chamber (조리실내의 유해오염물질 제거율에 관한 연구)

  • Kwon, Woo-Taeg;Lee, Woo-Sik
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.149-156
    • /
    • 2016
  • The purpose of this study is to reduce the contaminants (total volatile organic compounds (TVOCs), fine particle, odor and total airborne bacteria) during cooking process in cooking chamber, and to decrease the health damage in indoor space that has bad work environment. In order to solve the shortcomings of existing air purifiers and remove all kinds of pollutants effectively, this study focused on the development of indoor air purifiers which are made of bar type. Bio-ceramics filter which combines activated carbon and loess. The air cleaners developed with 4 measuring items including TVOCs, particulate matter, complex odor and total airborne bacteria were measured comparing their pre-service test to their post-service test after a period of time. The measured results showed higher removal efficiency of 91.02% as the concentration of TVOCs was reduced from $2,500{\mu}g/m^3$ to $223{\mu}g/m^3$. Second, the particulate matter removal ratio was 97.51% efficient with average concentration of $26.68{\mu}g/m^3$. Third, the odor showed 95.20% reduction as air dilution ratio averaged out at 144. Last, total airborne bacteria was eliminated by over 94% showing the changeable concentration from $787{\sim}814CFU/m^3$ to $47{\sim}40CFU/m^3$. In addition, the removal rate of harmful pollutants is excellent, and it is expected that the environment of the existing poor cooking room will be greatly improved by using the developed air purifier in combination with the ventilation device and the stove hood.

A Study on Work's Exposure to Dust, Crystalline Free Silica and Lead in Ceramic Industry (일부 요업사업장의 분진, 결정형 유리규산 및 납의 폭로에 관한 연구)

  • Oh, Se-Min;Shin, Yong-Chul;Park, Dong-Wook;Lee, Na-Roo;Park, Sueng-Hyun;Yi, Gwang-Yong;Moon, Young-Hahn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.168-179
    • /
    • 1994
  • In some ceramic industries, worker exposure to dust, crystalline free silica and lead were determined and evaluated. The conclusions are as follows. 1. Crystalline silica in bulk samples was 10.5 % in sanitary ware industry, 9.4 % in tile industry, and 2.1 % in ceramic insulator industry respectively. The free silica content of air filter sample was 8.03 % in table ware industry, 5.59 % in sanitary ware industry, and 1.32 % in ceramic insulator industry. Because silica content in ceramic dust is relatively high, it is should be considered silica as important factor in evaluating for ceramic industry. 2. The silica contents in dust from tile, sanitary ware and table ware industries are above 5%, it should be classified as "Type" 2 dust. 3. The airborne concentration of respirable crystalline silica was $27.9{\mu}g/m^3$ in a sanitary ware factory and $5.8{\mu}g/m^3$ in a ceramic insualtor factory. Three of ten samples sampled the above factories were exceeded the occupational exposure levels, $100{\mu}g/m^3$. 4. Geometric mean(GM) of total dust in 11 factories was $1.00mg/m^3$ and GM of respirable dust concentration in 5 factories was $0.33mg/m^3$. Sanitary ware industry had the highest concentration of total dust, $1.62mg/m^3$ and of respirable dust, $0.88mg/m^3$. 5. Average lead concentration in air was $0.05mg/m^3$ in glazing process of 2 factories manufacturing table ware. Five of ten sample(50%) were exceeded $0.05mg/m^3$. Therefore lead exposure in pottery industry should be considered as important problem.

  • PDF

Determination of Preservatives in Pharmaceuticals and Personal Care Products (의약품 및 개인위생·생활용품 중 보존제 함유량 분석)

  • Kim, Boyoung;Lee, Joohee;Kim, Seonyeob;Lee, Eunji;Choi, Chorong;Kho, Younglim
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.1
    • /
    • pp.53-60
    • /
    • 2016
  • Objectives: Preservatives are commonly used in pharmaceuticals, cosmetics and other products to extend the expiration date and prevent the growth of microorganisms. Preservatives are generally effective in controlling mold and inhibiting yeast growth, and against a wide range of bacterial attacks as well. They also adversely affect the quality of sperm and cause precocious puberty in children. This study was performed to analyze seven preservatives used in pharmaceuticals and personal care products. Methods: Five kinds of pharmaceuticals and personal care products (PPCPs) were examined for analysis with a high performance liquid chromatography-diode array detector. Each sample was homogenized and the targeted compounds were extracted with methanol. The suspended particulate was removed by syringe filter. Next, the sample was injected into an HPLC system. The separation of the seven preservatives was achieved with a C18 column and gradient mode. The accuracies were between 73% and 120% and precision was lower than 11.58% (RSD). Results: All of the calibration curves showed good linearity with a coefficient of determination ($r^2$) over 0.999. Among the PPCP samples, the detection rate of preservatives was 32.5% for pharmaceuticals, 44.8% for toothpaste, 76.9% for mouthwash, 40.0% for body lotion and 56.0% for wet tissues. The average concentrations of the preservatives in PPCPs were BA 1141.0 mg/kg, MP 709.8 mg/kg, EP 624.9 mg/kg, PP 216.9 mg/kg, BP 167.8 mg/kg, and TCS 538.2 mg/kg. The most frequently detected preservatives in pharmaceuticals and personal care products were BA, MP and PP. The concentrations of preservatives exceeded Korean regulatory standards in 11 samples of medicines, three of mouthwash and two of body lotion. Conclusion: We found that most of the PPCP samples contained various preservatives. It is necessary to identify which preservatives were used and to determine the level of preservatives in PPCPs and to assess the health risk to susceptible populations such as children.

Development of Magnet Position Device for Outdoor Magnet Guidance Vehicle (실외 자기유도 무인운반차를 위한 자기 위치측정 장치 개발)

  • Cho, Hyunhak;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.3
    • /
    • pp.259-264
    • /
    • 2014
  • This paper is research paper on the MPD(Magnet Position Device) for the outdoor MGV(Magnet /Magnet Gyro Guidance Vehicle). Usually, MGV is used in indoor environment because of a measurement height of the magnet position device. CMPD(Commercial magnet position device) has 30 mm measurement height, so this is suitable structure in indoor environment like to a flat surface. Outdoor environment is an uneven and irregular, So Outdoor MGV must has a suspension. But CMPD is unsuitable for outdoor environment because of a collision with a surface caused by suspension. Thus, measurement height of the outdoor MPD is positively necessary more than 100 mm. So, we suggest the outdoor MPD using analog magnet hall sensor, moving average filter and Characteristic(rate of the magnet hall sensor) function of the localization. Result of the experiments, the proposed Magnet Position Device for the outdoor MGV has localization accuracy 4.31 mm, measurement height 150 mm and width 150 mm and is efficient more than CMPD.

Development of depression diagnosis system using EEG signal (뇌파 측정 신호를 이용한 우울증 진단장치 개발)

  • Kim, Kyu-Sung;Jung, Ju-Hyeon;Lee, Woo-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.452-458
    • /
    • 2017
  • In this study, a device was developed for diagnosing depression using EEG signals from July 2016 to June 2017. For normal people, the left alpha rhythm is more activated than the right alpha rhythm, but for the depressed patients, the right alpha rhythm is more activated than the left one. An analog circuit and digital low pass filter were used for noise removal and amplification of EEG, and the Hamming window function was applied to eliminate the signal leakage generated by the fast Fourier transform. To verify the validity of the developed diagnosis system, the EEG of 20 university students in the 3rd and 4th grade with an average age of 24 years was measured. Calculations of the relative value of the left and right alpha rhythm for the depression diagnosis revealed a minimum, maximum, and mean value of 66.7, 113.3, and 92.2, respectively. In addition, 7 out of 20 subjects were between 90 and 95, and those with a higher mean deviation of approximately 20 tended to have mild depression. These results can provide meaningful data for the development of depression treatment equipment by solving the left and right brain asymmetry problem, and it may be applied usefully to diagnose depression after clinical trials on a large number of depressed patients.