• 제목/요약/키워드: average discharge

검색결과 734건 처리시간 0.034초

남해 강진만 담수유입에 따른 체류시간 변화 모델링 (Modeling Variation in Residence Time Response to Freshwater Discharge in Gangjin Bay, Korea)

  • 김진호;박성은;이원찬
    • 한국수산과학회지
    • /
    • 제54권4호
    • /
    • pp.480-488
    • /
    • 2021
  • The term residence time is defined as the time taken for substances in a system to leave the system and is a useful concept to explain the physical environment characteristics of a coastal area. It is important to know the spatial characteristics of the residence time to understand the behavioral properties of pollutants generated in a marine system. In this study, the spatial distribution of average residence time was calculated for Gangjin Bay, Korea, using a hydrodynamic model including a particle tracking module. The results showed that the average residence time was about 10 days at the surface layer and about 20 days at the bottom layer. Spatially, this was the longest residence time in the southwestern sea. There was no significant difference in average residence time at the surface layer due to freshwater discharge, but spatial variation at the bottom layer was larger. The average residence time at the bottom layer decreased in the southwestern area due to freshwater discharge and increased in the northern area. This result suggests that the residence time of anthropogenic pollutants may have a large spatial difference depending on the freshwater discharge, and thus the time taken to influence cultured organisms may also vary.

방사전자파 특성을 이용한 부분방전 검출의 기초연구 (The Fundamental Study About Partial Discharge Detection With The Radiated Electromagnetic Wave Characteristics)

  • 이상훈;박광서;김충년;이현동;송현직;김기채;이광식;이동인
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권7호
    • /
    • pp.412-417
    • /
    • 2000
  • This paper offer fundamental materials about Partial Discharge(PD) detection by electromagnetic waves. All spectrum data-usually used as grape- can be used as numbers. And then the average of background noise spectrum strength was made. Average value subtract from every data. Then average value appeared, graphed. The graph was compared with the magnitude of charge. The shape of changes is similar, and the change of electric field strength could be seen in one sight. When the magnitude of charge is over than 100[pC], antenna can detect partial discharge. So this method will be very useful to diagnosis of insulation. It the performance of the antenna used in this experiment is analyzed, good results can be obtained.

  • PDF

고체절연체의 내부결함에 따른 부분방전 특성과 패턴분류 (Properties of PD and Classification of Defect Patterns in Solid Insulation)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1624-1626
    • /
    • 1999
  • PD in defect of solid insulation system is very harmful since It often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge. PD can indicate incipient failure, so it has been used to determine degradation of insulation. In this paper. we investigated PD in defects of solid insulation by using statical method and classified PD patterns with surface discharge, electrical tree and void discharge by using Kohonen network. we used peak charge, average discharge power, average discharge current, repetition rate, skewness, kurtosis, QN of the max pulse height vs. repetition rate $H_q(n)$ for analysis and classification.

  • PDF

MnO2입자 크기에 따른 아연공기전지의 특성연구 (Size Effects of the Catalyst on Characteristics of Zn/Air Batteries)

  • 김지훈;엄승욱;문성인;윤문수;김주용;박정식;박정후
    • 한국전기전자재료학회논문지
    • /
    • 제16권12호
    • /
    • pp.1150-1154
    • /
    • 2003
  • The voltage profile during discharge of the zinc air battery has very flat pattern until reach to end of discharge voltage. But, when zinc air battery is discharged by high current, the discharge voltage and energy becomes low. Therefore, we focused on effects of catalyst size to solve this problems by increasing active sites of oxygen reduction reaction. The size of catalyst was reduced from 27 to l${\mu}{\textrm}{m}$ and we examined average discharge voltage, capacity, energy, resistance and characteristics during GSM pulse discharge of zinc air battery with change of current density. And we also measured porosity of the cathode according to the ASTM. So we have got improvement of average discharge voltage and energy when catalyst was minimized and we have got optimum size of catalyst at 5${\mu}{\textrm}{m}$.

저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성 (Properties of Partial Discharge accompanying with Electrical Tree in LDPE)

  • 이광우;박영국;강성화;장동욱;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

소하천수계의 단위유량도 유도 및 비교에 관한 수문학적 고찰 (Hydrological Studies on the Comparison and the Derivation of Unit Hydrography in the small River Systems.)

  • 이순혁
    • 한국농공학회지
    • /
    • 제20권3호
    • /
    • pp.4739-4749
    • /
    • 1978
  • This studies were conducted to derive synthetic unitgraphs and triangular unitgraphs correlated with watershed characteristics which can be used to the estimation and control of flood for the rational development of Agricultural water resources. Derived Synthetic unitgraphs and Triangular unitgraphs can be applied to the ungaged watersheds were compared with average unitgraphs by observed data. Seven small watersheds were selected as studying basins Han, Geum, Nakdong, Yeongsan and Inchon river system. The results summarized for these studies are as follows: 1. Average unitgraphs by observed data and dimensionless unitgraphs for synthesis were derived for all river systems. 2. Peak discharge per unit area of the unitgraph, qp, was derived as qp=10-0.389-0.0424Lg with a high significance. 3. Formulas for the base width of unitgraph of 50 and 75 percent for peak flow for each water systems was adopted as Table 5. 4. The base length of the unitgraph, Tb, in hours in connection with time to peak, Tp, in hours was expressed as Tb =4.3Tp. 5. Peak discharge, Qp, were obtained as Table 6 by the Triangular form to all subwatersheds. 6. Relative errors in the peak discharge of the synthetic unitgraphs showed to be 7.3 percent to the peak of observed average unitgraphs except errors of peak discharge for Yeongsan river system. This indicates that Synthetic unitgraphs for the small watersheds of Han, Geum, Nakdong and Inchon river systems can be applied to the ungaged watersheds. On the other hand, It was confirmed that the accuracy of Instantaneous Unit Hydrograph with only 1.6 percent as relative errors was approaching more closely to the observed average unitgraph than that of synthetic unitgraph with relative errors. 23.9 percent for Yeongsan river system. 7. Errors in the peak discharge of the triangular unitgraph to the observed average unitgraph showed to be 0.6 percent to 7.5 percent which can be regarded as a high precision within the range of 200 to 500$\textrm{km}^2$ in area. On the contrary, application of triangular unitgraph within the range of 200$\textrm{km}^2$ in area has defined as a unsuitable method because of high relative errors, 26.4 percent to 61.6 percent.

  • PDF

도서지역 하천의 기저유출량 산정을 위한 유량측정방법 제안 (A Proposal of Baseflow using Discharge Measurement Method in the Streams of Island)

  • 이준호;양성기;정우열
    • 한국환경과학회지
    • /
    • 제23권4호
    • /
    • pp.561-569
    • /
    • 2014
  • The water resources system of Jeju-do Island entirely depends on groundwater. This study is making a precision observation of baseflow, surface water, water shortage that might be vulnerable to climate change and drought in future. The field observation of baseflow discharges in Akgeuncheon stream has regularly been made with ADCP and ADC and Flowmate every two weeks for twenty-two (22) months (July 8, 2011 to April 27, 2013). This paper represent the results of calculating discharge of a number of hydraulic structures (broad-crested weirs) with comparing and has been calculated more accurate discharges with suitability of different observation methods. The average discharge has been observed 0.851 $m^3/s$, whereas the average ADC and Flowmate is 0.709 $m^3/s$. Meanwhile, stream discharge has been calculated 0.709 $m^3/s$ through the broad-crested weir equation. The discharge has calculated with the weir equation greatly changed according to even a small change in the water level. However, it showed a similar trend to one of the observed discharge. Although, in past there were generating errors caused by observers' strides, vertical and horizontal flow velocity distribution when the average flow velocity had been measured, non-prismatic flow, turbulent flow and others in ADC. This study comes up with the weir equation is more suitable for the characteristics of Jeju-do could be presented through an observations of baseflow discharge.

아연-공기 전지용 전해질의 Gelling Agent 분자량에 따른 자가 방전 억제 효과 (Effect of Gelling Agent Molecular Weight on Self-Discharge Behavior for Zinc-Air Batteries)

  • 박정은;조용남
    • 한국재료학회지
    • /
    • 제29권12호
    • /
    • pp.812-817
    • /
    • 2019
  • A zinc-air battery is one of most promising advanced batteries due to its high specific energy density, low cost, and environmental friendliness. However, zinc anodes in zinc-air batteries lead to several issues including self-discharge, corrosion reaction, and hydrogen evolution reaction (HER). In this paper, viscosity of electrolyte has been controlled to suppress the corrosion reaction, HER, and self-discharge behavior. Various viscosity average molecular weights of poly(acrylic acid) (PAA) are adopted to prepare the electrolyte. The evaporation of electrolytes is proportional to the increase in molecular weight. In addition, enhanced self-discharge behavior is obtained when the gelling agent with high molecular weight is used. In addition, the zinc-air cell assembled with lower viscosity average molecular weight of PAA (Mv ~ 450,000) delivers 510.85 mAh/g and 489.30 mAh/g of discharge capacity without storage and with 6 hr storage, respectively. Also, highest capacity retention (95.78 %) is obtained among studied materials.

강우시 포도밭에 대한 초기세척효과 분석 (Analysis of First Flushing Effects for the Vineyard Storm Runoff)

  • 윤영삼;권헌각;이재운;유재정;이재관
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.977-986
    • /
    • 2011
  • This study analyzed the characteristics of stormwater runoff in the orchard areas and quantitatively estimated effluence of nonpoint source pollutants for the volume of runoff. Two target areas under vine cultivation were each $2,000m^2$ and $1,800m^2$, located in Gyeongju City. Since grape was the only crop on the target area, the characteristics of stormwater runoff at vineyard could be evaluated independently. A total of 51 rainfall events in the vineyard area during two years(2008-2009) was surveyed, and 19 of them became stormwater runoff, with rainfall ranging 16.5 - 79.7 mm and antecedent dry period of 1-13 days. The pollutant runoff loads by volume of stormwater runoff showed BOD ranging 19.5 - 45.3% in 30% of runoff volume. The average pollution discharge rate was 32.4%, indicating small first flush effect of BOD. The range of SS concentrations was 5 - 52.0% in 10% of runoff volume, showing the average 28.7% of discharge rate, about 3 times more than rainfall effluent. TOC and TN appeared to be similar to the results of BOD, the average discharge rate of 30.9% and 30.6% for TOC and TN, respectively, for 30% of stormwater runoff volume. Average discharge rate of COD and TP in the same runoff volume was 35.1% and 36%, respectively, showing comparatively high discharge ratio. As the targeted vineyard area was permeable land, the pollution load ratio against rainfall-runoff volume appeared to be 1:1, implying no strong first flush effect for all the survey items.

퇴원에 따른 만성 질환아 어머니의 반응과 환아 돌보기 지지 요구 (The Reaction and the Supporting Need for the Mother in Caring for their Chronicly III Child after Discharge)

  • 채현이
    • 가정간호학회지
    • /
    • 제8권1호
    • /
    • pp.50-61
    • /
    • 2001
  • With the improvement of current medicine, the number of the chronicly ill children are increasing. The illness of the child drives all of the family to despair. especially it is a burden on the mother who takes care of the ill child. She's faced with many emergencies and feels powerless. The home care for a child is for finding a child's problems early and mediating them. The purpose of this study was to investigate the mother's reaction following their chronicly ill child's discharge and to investigate the supporting needs for caring for an ill child. The subjects of this study were mothers with a chronicly ill child being discharged from a general hospital in Seoul and the data was collected from July 20 to September 30. Data was collected by using questionnaires which were developed by the researcher. (The questionnaires were composed of the average 5 points - Likert's method). The Mother's reaction means that the higher the score, the more negative the mother's thoughts about discharge are. Supporting need for caring for ill an child means that the higher the score, the higher the demand of nursing is. The statistical analysis used the SPSS program for t-test. ANOVA, and Pearson Correlation. The results of this study were as follows: 1. The mother's reaction scores following discharge were the lowest. 19 and the highest 72 so that the total average was 43.15. The answer, 'I worry that my baby will be troubled with illness again after discharge gained the high points (3.94 of 5 points). The answer. 'The discharge of my baby makes me gloomy' gained 2.05-it was the lowest points. Their were significant differences according to religion (p=.006). salary (p=.050). the burden of the medical fee (p = .005) and caregiver (p=.027). 2. Supporting Need for caring for ill an child was the lowest 15 and the highest 67. the total average was 47.87. The answer. 'I'd be glad to get a person whom I could always get counsel about the health of my baby with' scored the high point (average 4.04 of 5). The answer. 'Caring for my baby at home makes me exhausted' gained the lowest point. 2.49. Their were significant differences according to religion (p=.019) and diagnosis (p=.019). 3. The relationship between the reaction of the mother and supporting need for caring for an ill child was a positive correlation (r=0.585). In conclusion. this study revealed that mothers weren't positive about their chronicly ill child's discharge and they wanted to get support for caring for an ill child. Through this study. I proposed that the program to support the chronicly ill child at home and home care by continuous counselling after discharge should be develop.

  • PDF